Page 38

Chapter 7 Troubleshooting

7 Troubleshooting

<Display Indicator>

When either the Safety Light Curtain SL-C Series or the Intelligent Safety Relay Unit SL-R11 experiences an error, it is possible to determine the cause of the error by referring to the state of the bar LED display on the SL-C. When the lock-out indicator (orange) is flashing, the device can be returned to normal operation by turning it off and then on again once the cause of the problem has been rectified. The following stickers have been affixed to transmitters and receivers. Verify the on/off status of the LED after checking the orientation of the system's transmitters and receivers. Transmitter Receiver SL-C08H

Transmitter

SL-C08H 24V DC 55mA Class2 See Instruction Manual

RATED VOLTAGE / CURRENT TYPE OF POWER SUPPLY

24V DC 67mA Class2 See Instruction Manual

RESPONSE TIME DETECTION ZONE (PROTECTION ZONE) DETECTION CAPABILITY EAA ENCLOSURE RATING AMBIENT TEMPERATURE

15ms 140mm(185mm) φ 25/ φ 45/ φ 65/ φ 85mm ± 2.5˚ (3m or more) IP65 -10˚C to 55˚C

RESPONSE TIME DETECTION ZONE (PROTECTION ZONE) DETECTION CAPABILITY EAA ENCLOSURE RATING AMBIENT TEMPERATURE

15ms 140mm(185mm) φ 25/ φ 45/ φ 65/ φ 85mm ± 2.5˚ (3m or more) IP65 -10˚C to 55˚C

Transmitter

1 and all lamps alternately light up

2 lights up

7

4 and all lamps alternately light up

English ENGLISH

5 lights up

6 lights up

7-1 7-2

7 6 5 4 3 2 1 ON/OFF FUNCTION

1. Lockout indicator

2. Bar LED

3. Output status indicator 4. Function indicator

Description

Causes and solutions

Transmitter error

1 lights up

• Reconnect the transmitter and cable as described in section 2-3-1 “Connecting Cable Installation” (➮2-7) in the SL-C manual. • Reconnect the SL-R11 and transmitter connectors as described in section 4-1 “Method for Connection to the SL-C Series” (➮4-1) in the SL-R11 manual. • The transmitter is damaged. Replace the sensor. • Remove any extension cable from the transmitter side (Receiver Side). • Remove any series connection heads and retest with only the first set of heads.

Receiver error 2 and all lamps alternately flash

• Reconnect the receiver and cable as described in section 2-3-1 “Connecting Cable Installation” (➮2-7 ) in the SL-C manual. • Reconnect the SL-R11 and receiver connectors as described in section 4-1 “Method for Connection to the SL-C Series” (➮4-1) in the SL-R11 manual. • The receiver is damaged. Replace the sensor. • Remove any extension cable from the transmitter side (Receiver Side). • Remove any series connection heads and retest with only the first set of heads.

Receiver

SL-R11 error

3 lights up

8

Receiver

RATED VOLTAGE / CURRENT TYPE OF POWER SUPPLY

Bar LED display status

LOCKOUT

3 lights up

4 lights up

Inconsistent number of transmitter and receiver beam axes

• Different models of transmitter and receiver are being used so that the number of beam axes does not match. Use a proper combination of models. • If being connected in series, use the same model and number of connected SL-C units on both the transmitter and receiver sides of the system.

Light interference Interfering light received

• The receiver is receiving light that originated in an SL-C transmitter that is not its matched pair. Fix this problem as described in either section 2-3-5 “Light Interference Prevention Method” (➮2-12) in the SL-C manual or section 4-4 “About the Light Interference Prevention Connection” in the SL-R11 manual (➮4-9). • The receiver is receiving light originating from an inverter fluorescent light or another sensor. Prevent this light from entering the receiver by adjusting the location at which the sensor is installed or installing a masking plate.

Communications error

• Reconnect the SL-R11 to the SL-C as described in section 4-1 “Method for Connection to the SL-C Series” (➮4-1) in the SL-R11 manual. • If light interference prevention connections have been made, the main/sub switch is set so that there are multiple mains configured. Always configure the system so that there is only 1 main, as described in section 4-3-4 “Connecting to Main/Sub Select Input Terminal” (➮4-7) in the SL-R11 manual. • If the unit has been configured as a sub with the light interference prevention connection, the power has been cut to the sensor that is configured for either the main or the sub that is connected closer to the main. Be careful not to cut power to only some of the connected sensors.

5 and all lamps alternately light up

6 lights up

• Reconnect the SL-R11 and SL-C connectors as described in section 4-1 “Method for Connection to the SL-C Series” (➮4-1) in the SL-R11 manual. • The wrong cable is being used to connect the SL-R11 and SL-C. Use the correct type of cable as described 4-1 “Method for Connection to the SL-C Series” (➮41) in the SL-R11 manual. • The SL-R11 mode switch has not been set properly. Follow the instructions in section 2-11 “Mode switch setting (➮2-5)” of this manual to set the switch properly. • The short bar attached when shipped from the factory is detached or loose. Attach the short bar according to the function setting to be used. If it is already attached, tighten the screws on the terminal block. • If the MPCE monitor function is being used, the MPCE is damaged or has not been wired properly. Check the MPCE and its wiring as described in section 43-3 “Wiring to the MPCE Monitor Input Terminal” (➮4-6) in the SL-R11 manual. • The SL-R11 is damaged and needs to be replaced.

Page 39

Chapter 7 Troubleshooting Bar LED display status Transmitter Receiver

Description

Causes and solutions • The cable connected to the SL-C has its transmitter and receiver ends reversed. Connect the cable properly as described in section 2-3-1 “Connecting Cable Installation” (➮2-7) in the SL-C manual.

OSSD error 7 lights up

7 and all lamps alternatively flash

• Reconnect the SL-R11 to the SL-C as described in section 4-1 “Method for Connection to the SL-C Series” (➮4-1) in the SL-R11 manual. • The OSSD is damaged. Replace the sensor. • The SL-R11’s FSD has failed due to contact adhesion or a similar cause. Replace the relay board as described in section 4-2-1 “How to replace the relay output terminal block” (➮4-2) in the SL-R11 manual.

FSD error 8 lights up

8 lights up

• Verify that the relay board has been installed properly as described in section 42-1 “How to replace the relay output terminal block” (➮4-2) in the SL-R11 manual and 6-2 “Relay Circuit Board Replacement” (➮6-1) in the SL-R11 manual. • Either the beam axes are completely misaligned, or are being blocked by a shielding object. Readjust the beam axes as described in section 3-9 “Beam Axis Adjustment” (➮3-8) in the SL-C manual. • Verify that the operating distance does not fall outside of the range indicated by the specifications.

No beam is being received 1 flashes

1 flashes

• The test input terminal is open. Short the test input terminal during normal use as described in section 4-3-5 “Wiring to the Test Input Terminal” (➮4-8) in the SL-R11 manual.

Beam is being blocked Multiple lamps light up red

Multiple lamps light up red

Unstable light reception (allowance of 100 to 110%) All lamps flash green

• The switch setting is not correct. Configure the switch properly as described in section 4-3-4 “Connecting to Main/Sub Select Input Terminal” (➮4-7) in the SLR11 manual.

All lamps flash green

• Some of the beam axes are misaligned or are being blocked by an obstacle. Readjust the beam axes as described in section 3-9 “Beam Axis Adjustment” (➮3-8) in the SL-C manual. • Verify that the operating distance does not fall outside of the range indicated by the specifications. • The beam axes are not completely aligned, or are being blocked by an obstacle. Readjust the beam axes as described in section 3-9 “Beam Axis Adjustment” (➮3-8) in the SL-C manual. • Verify that the operating distance does not fall outside of the range indicated by the specifications.

7

• Dirt, oil is building up on the heads. Crean them with wet cloth.

• The power supply voltage drops consecutively or instantaneously. • Replace the power supply or increase the power supply capacity. The power supply voltage drops 1 flashes

• Stop supplying power to other devices, and use the dedicated power supply.

All lamps are off

• Power is not being properly supplied to either the SL-C or the SL-R11. Check the cable connector, the power supply connector, and the power supply voltage. Power has not yet been turned on All lamps are off

• Either the SL-C or the SL-R11 is damaged and needs to be replaced.

All lamps are off

7-2 7-3

ENGLISH

When attempting any of the solutions described above, be sure to follow the appropriate procedures properly, after referring to all necessary manual sections. Contact your nearest Sales Office if the device fails to resume normal operation after the above solutions are implemented, or if your system exhibits problem symptoms other than those described above.

Page 40

Chapter 8 Revision History

8 Revision History First Edition Second Edition Third Edition Fourth Edition Fifth Edition Sixth Edition Seventh Edition Eighth Edition Revised 1st Edition

Feb. 2003 Apr. 2003 Aug. 2003 Sep. 2003 Jan. 2004 Aug. 2005 Oct. 2009 Mar. 2010 Nov. 2014

8

English ENGLISH 8-1 8-2 08_SL-R11E.p65

2

14.9.12, 7:40 PM

Page 41

WARRANTIES AND DISCLAIMERS

(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.

BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples.

ENGLISH E 1101-3

08_SL-R11E.p65

3

14.9.12, 7:40 PM

Page 42 read from a scan by OCR; it may hold reading errors

KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan

PHONE: +81-6-6379-2211 www.keyence.com AUSTRIA HUNGARY SINGAPORE

Ph: +43 22 36-3782 66-0 Ph: +36 1 802 73 60 Ph: +65-6392-1011 BELGIUM INDIA SLOVAKIA

Ph: +32 1 528 1222 Ph: +91-44-4299-4192 Ph: +421 2 5939 6461 BRAZIL ITALY SLOVENIA

Ph: +55-11-3045-4011 Ph: +39-02-6688220 Ph: +386 1-4701-666 CANADA KOREA SWITZERLAND

Ph: +1-905-366-7655 Ph: +82-31-789-4300 Ph: +41 43-45577 30 CHINA MALAYSIA TAIWAN

Ph: +86-21-68757500 Ph: +60-3-2092-2211 Ph: +886-2-2718-8700 CZECH REPUBLIC MEXICO THAILAND

Ph: +420 222 191 483 Ph: +52-81-8220-7900 Ph: +66-2-369-2777 FRANCE NETHERLANDS UK & IRELAND

Ph: +33 1 56 37 78 00 Ph: +31 40 20 66 100 Ph: +44-1908-696900 GERMANY POLAND USA

Ph: +49 6102 36 89-0 Ph: +48 71 36861 60 Ph: +1-201-930-0100 HONG KONG ROMANIA

Ph: +852-3104-1010

Ph: +40 269-232-808

Specifications are subject to change without notice.

ets F-LYA eyUUsRSB 7533-8555 ABR RE) IRAE 1- 3-14 sSHUGhHt