DL305 User Manual: Chapter 11: Instruction Set, pages 290 to 295

Pages 290 to 295 of 357, from DL305 User Manual

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PLC Direct D3-08TD1, PLC Direct D3-16NA, Koyo D3-08TD1 and Koyo D3-16NA

Page 290

Instruction Set Program Control Instructions

11--51

DirectSOFT Display

Handheld Programmer Keystrokes

000 MCS 001

A

160 OUT

002

161 OUT

165

20 OUT

010

C MCS

003

170 OUT

004

171 OUT D

STR MCS STR OUT STR OUT STR OUT STR MCS STR OUT STR OUT MCR STR OUT STR OUT MCR STR OUT

SHF ENT SHF SHF SHF SHF SHF SHF SHF ENT SHF SHF SHF SHF ENT SHF SHF SHF SHF ENT SHF SHF

0

ENT

1 1 2 1 1 2 1

ENT 6 ENT 6 6 0 0

ENT ENT

3 1 4 1

ENT 7

0

ENT

ENT 7

1

ENT

5 1 6 2

ENT 7

2

ENT

ENT 1

ENT

7 2

ENT 2

ENT

0

ENT

1 5

ENT ENT

MCR 005

172 OUT

006

21 OUT B MCR

007

22 OUT

NOTE: When programming the MCS instruction, do not put any parallel coils in the rung with the MCS.

DL305 User Manual, Rev. D

Instruction Set

MCS/MCR Example In the following MCS/MCR example logic between the first MCS (A) and the last MCR (B) will function only if input 000 is on. The logic between the second MCS (C) and the next to last MCR (D) will function only if input 010 is on. The last rung is not controlled by either of the MCS coils.

Page 291

11--52

Instruction Set Network Instructions

Instruction Set

Network Instructions Read from Network The Read from Network instruction is used RX (F952) by the master device on a DirectNET DL340 Only network to read a block of data from another CPU or DirectNET interface module. The function parameters are loaded into the accumulator and the first and second level of the accumulator stack by three additional instructions. Listed below are the steps necessary to program the Read from Network function.

RX (F952) A aaa

Step 1:, Load the slave address (1--90 BCD) into the accumulator with the DSTR instruction. This must always be preceded by 00, so address 20 would be 0020. (Remember, D4--DCM slave device addresses are set with switches that use a hexadecimal format. Make sure you convert this address to the decimal equivalent for use with this instruction.) Step 2:, Load the number of bytes (1 -- 128 BCD) to be transferred from the network slave station. Step 3:, Load the octal address for the data register that will be used to store the data obtained from the slave station. Step 4:, Insert the RX instruction which specifies the starting address in the slave station. If you are getting the data from a DL305 station, just enter the Data Register number. If you are getting the data from a DL205 or DL405 station, enter a constant that corresponds to the memory address. For example, to get the current count for Timer 600 from a DL305 CPU, you would use R600 with the RX instruction. If you wanted to get Counter 0 from a DL405 CPU, you would use a constant of 1000 with the RX instruction. (V1000 stores the current count for Counter 0 in a DL405 CPU.) NOTE: The DirectNET manual provides further information on the use of the RX and WX network instructions. Data Type

D3--330 Range

D3--340 Range

A aaaa aaaa

D3--330P Range aaaa

Inputs / Outputs

R

000--014 070--075

000--014 070--075

000--014 070--075

Control Relays

R

016--036

016--036 100--105

016, 020--027

Shift Registers

R

040--056

040--056

----

Stages

R

----

----

100--116

Timer /Counters (16 bit)

R

600--677

600--677

600--677

Data Registers

R

400--577

400--577 700--777

400--577

*Constant (4--digit BCD)

K

0000--9999

0000--9999

0000--9999

* A constant is used to obtain data from a DL205 or DL405 system. Discrete Bit Flags

Description

777

Parameters are not properly set. Check the slave address, data length, or data address reference.

1074

Communication port busy.

1075

Communication error. Data was not transmitted.

DL305 User Manual, Rev. D

Page 292

Instruction Set Network Instructions

11--53

In the following example, when input 001 is on and the CPU busy relay 1074 (see special relays, p. 8--32) is not on, the RX instruction will access a DL405 CPU that has been assigned station address 20. (Note, the D4--DCM slave station addresses are set with switches that indicate a hexadecimal number. Make sure you determine the decimal equivalent to be used with the first DSTR instruction in the sequence.) Ten consecutive bytes of data (V1400 -- V1404) will be read from the slave station and stored in registers R400 -- R411. (Remember, the DL205 and DL405 V-memory locations are 16 bits. The DL305 registers are only 8 bits, so you have to use two data registers for each V-memory location.) DirectSOFT Display 001

1074

DSTR (F50) K0020 The constant value K0020 specifies station address 20 (hex)

DL305 CPU

Slave CPU

S S

S S

DSTR (F50) K0010 The constant value K10 specifies the number of bytes to be read

DSTR (F50) K0400 Octal address 0400 is used to designate R400 as the starting point for the range of registers that will hold the data

RX (F952) K1400

R401

R400

3

5

4

7

R403

R402

8

3

5

4

R405

R404

1

3

9

6

R407

R406

9

7

5

1

R411

R410

1

2

4

3

3

4

5

7

V1400

8

5

3

4

V1401

1

9

3

6

V1402

9

5

7

1

V1403

1

4

2

3

V1404

K1400 is used to represent V1400, which is the starting location in the for the Slave CPU where the specified data will be read from

Handheld Programmer Keystrokes

STR AND F SHF F SHF F SHF F

SHF NOT 5 0 5 1 5 4 9

1 SHF 0 0 0 0 0 0 5

ENT 1 ENT 2 ENT ENT ENT 0 2

ENT ENT

SHF

1

4

0

0

0

7

0

ENT

4

ENT

ENT

DL305 User Manual, Rev. D

Instruction Set

NOTE: See the DL205 or DL405 User’s Manuals for a listing of V-memory addresses available with these CPUs. Since the DL305 only supports a 4-digit constant, you will not be able to access the entire V-memory ranges of the DL205 and DL405 CPUs. For example, you could not directly access V40400 stored in a DL405 CPU. If you require data from a range outside the area available with a 4-digit constant (from V0 -- V9999) then add a routine to the slave station program that moves this data down into one of the accessible areas.

Page 293

Instruction Set

11--54

Instruction Set Network Instructions

Write to Network WX (F953) DL340 Only

The Write to Network instruction is used by the master device on a DirectNET network to write a block of data to another WX (F953) station. The function parameters are A aaa loaded into the accumulator and the first and second level of the accumulator stack by three additional instructions. Listed below are the steps necessary to program the Write to Network function. Step 1:, Load the slave address (1--90 BCD) into the accumulator with the DSTR instruction. This must always be preceded by 00, so address 20 would be 0020. (Remember, the D4--DCM slave device addresses are set with switches that use a hexadecimal format. Make sure you convert this address to the decimal equivalent for use with this instruction.) Step 2:, Load the number of bytes (1 -- 128 BCD) to be transferred to the network slave station. Step 3:, Load the octal address for the data register that will be used to obtain the data that will be sent to the slave station. Step 4:, Insert the WX instruction which specifies the starting address in the slave station. If you are sending data to a DL305 station, just enter the Data Register number. If you are sending data to a DL205 or DL405 station, enter a constant that corresponds to the memory address. For example, to send data to Register 500 in a DL305 CPU, you would use R500 with the RX instruction. If you wanted to send data to V1400 in a DL405 CPU, you would use a constant of 1400 with the WX instruction. NOTE: The DirectNET manual provides further information on the use of the RX and WX network instructions. Data Type

D3--330 Range

D3--340 Range

D3--330P Range

A aaaa aaaa aaaa

Inputs / Outputs

R

000--014 070--075

000--014 070--075

000--014 070--075

Control Relays

R

016--036

016--036 100--105

016, 020--027

Shift Registers

R

040--056

040--056

----

Stages

R

----

----

100--116

Timer /Counters (16 bit)

R

600--677

600--677

600--677 400--577 0000--9999

Data Registers

R

400--577

400--577 700--777

*Constant (4--digit BCD)

K

0000--9999

0000--9999

* A constant is used to send data to a DL205 or DL405 system. Discrete Bit Flags

Description

777

Parameters are not properly set. Check the slave address, data length, or data address reference.

1074

Communication port busy.

1075

Communication error. Data was not transmitted.

DL305 User Manual, Rev. D

Page 294

Instruction Set Network Instructions

11--55

In the following example, when input 001 is on and the CPU busy relay 1074 (see special relays, p. 8--32) is not on, the WX instruction will access a DL405 CPU that has been assigned station address 20. (Note, the D4--DCM slave station addresses are set with switches that indicate a hexadecimal number. Make sure you determine the decimal equivalent to be used with the first DSTR instruction in the sequence.) Ten consecutive bytes of data (R400 -- R411) will be sent from the DL340 and stored in V-memory locations V1400 -- V1404. (Remember, the DL205 and DL405 V-memory locations are 16 bits. The DL305 registers are only 8 bits, so you have to use two data registers for each V-memory location.) DirectSOFT Display 001

1074

DSTR (F50) K0020 The constant value K0020 specifies station address 20 (hex)

DL305 CPU

Slave CPU

S S

S S

DSTR (F50) K0010 The constant value K10 specifies the number of bytes to be send

DSTR (F50) K0400 Octal address 0400 is used to designate R400 as the starting point for the range of registers that holds the data in the DL340.

WX (F953) K1400

R401

R400

3

5

4

7

R403

R402

8

3

5

4

R405

R404

1

3

9

6

R407

R406

9

7

5

1

R411

R410

1

2

4

3

3

4

5

7

V1400

8

5

3

4

V1401

1

9

3

6

V1402

9

5

7

1

V1403

1

4

2

3

V1404

K1400 is used to represent V1400, which is the starting location in the for the Slave CPU where the specified data will be stored.

Handheld Programmer Keystrokes

STR AND F SHF F SHF F SHF F

SHF NOT 5 0 5 1 5 4 9

1 SHF 0 0 0 0 0 0 5

ENT 1 ENT 2 ENT ENT ENT

0

7

0

ENT

0 3

ENT ENT

SHF

1

4

0

0

4

ENT

ENT

DL305 User Manual, Rev. D

Instruction Set

NOTE: See the DL205 or DL405 User’s Manuals for a listing of V-memory addresses available with these CPUs. Since the DL305 only supports a 4-digit constant, you will not be able to access the entire V-memory ranges of the DL205 and DL405 CPUs. For example, you could not directly access V40400 stored in a DL405 CPU. If you want to send data to a range outside the area available with a 4-digit constant (from V0 -- V9999) then add a routine to the slave station program that moves the data from one of the accessible areas into the unavailable locations.

Page 295

11--56

Instruction Set Message Instructions

Instruction Set

Message Instructions Fault FAULT (F20)

The Fault (F20) instruction is used to display a 4--digit BCD constant, 16--bit register, or two consecutive 8--bit data registers on the handheld programmer or in DirectSOFT. When the fault instruction is executed the number being displayed will also be copied into the registers R574 and R575 and the discrete bit flag 771 will be on.

FAULT (F20)

In the following example, when input 000 is on the number 0206 will be displayed on the programming device. This would typically be a user defined error code. Data Type

D3--330 Range

D3--340 Range

D3--330P Range

A aaaa aaaa aaaa

Inputs / Outputs

R

000--014 070--075

000--014 070--075

000--014 070--075

Control Relays

R

016--036

016--036 100--105

016, 020--27

Shift Registers

R

040--056

040--56

----

Stages

R

----

----

100--116

Timer /Counters (16 bit)

R

600--677

600--677

600--677 400--577 0000--9999

Data Registers

R

400--577

400--577 700--777

Constant (4--digit BCD)

K

0000--9999

0000--9999

DirectSOFT Display

Handheld Programmer Display

000 FAULT (F20) K 0206

0206 ADDRESS/DATA ON/OFF

RUN BATT PWR CPU

DL305 User Manual, Rev. D

0 AND 1 OR 2 STR 3 NOT

4 OUT 5 TMR 6 CNT 7 SR

0 MCS 1 MCR 2 SET 3 RST

Handheld Programmer Keystrokes

4 ADR 5 SHF 6 DATA 7 REG

STR F

SHF 2

0 0

ENT ENT

SHF

2

0

6

ENT