Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DL305 User Manual

Manual · Koyo

DL305 User Manual

Manual357 pagesPDF 3.4 MB

User manual for the DirectLOGIC DL305 PLC system: DL330, DL330P and DL340 CPUs, bases, and I/O modules such as the D3-16NA and D3-08TD1.

Download the PDF3.4 MB

Covers · 4 models

The models it covers

Summary

What is in it

The AutomationDirect user manual for the DL305 PLC family. It covers installation and safety, the DL330, DL330P and DL340 CPUs, bases and I/O configuration, I/O module selection and wiring, and a page per discrete module, including the D3-16NA 110 VAC input module and the D3-08TD1 24 VDC output module. Later chapters explain system operation, programming basics, RLLPLUS stage programming, the instruction sets, and maintenance and troubleshooting, with error codes in an appendix.

Its parts

  1. Getting Started
  2. Installation and Safety Guidelines
  3. DL330/DL330P/DL340 CPU Specifications
  4. Bases, Expansion Bases, and I/O Configuration
  5. I/O Module Selection & Wiring Guidelines
  6. Discrete Input Modules
  7. Discrete Output Modules
  8. System Operation
  9. Programming Basics
  10. RLLPLUS Programming Basics
  11. Instruction Set
  12. RLLPLUS Instruction Set
  13. Maintenance and Troubleshooting

From the manual

Key facts from this manual

Each line names its page in the PDF.

DL305 User Manual (Rev. D) for the DirectLOGIC DL305 PLC family: the DL330, DL330P and DL340 CPUs, bases, and the discrete and other I/O modules. It includes specification sheets and wiring diagrams for the D3-16NA 110 VAC input module and the D3-08TD1 24 VDC output module. It also covers installation, power budgets, programming, maintenance and troubleshooting.

Read for this summary: pages 21 to 23, 93 to 95, 102, 105 to 106, 110 to 111, 113 to 114, 123, 133, 327 to 328 and 353 of 357.

D3-16NA type
D3-16NA: 110 VAC discrete input module for the DL305 p. 123
D3-08TD1 type
D3-08TD1: 24 VDC discrete output module, current sinking, NPN (open collector) p. 133
D3-16NA field supply
D3-16NA: 80-132VAC line and common on the wiring diagram p. 123
D3-08TD1 load supply
D3-08TD1: 5-24VDC; 0.5A per point p. 133
D3-16NA base power
D3-16NA: 9V, 100 mA max; typical 4 mA per ON point, 64 mA total p. 94, 123
D3-08TD1 base power
D3-08TD1: 9V 20 mA max; 24V 3 mA per point (24 mA max) p. 95, 133
D3-08TD1 fuses
D3-08TD1: one 3A fuse per common, non-replaceable p. 133
D3-16NA weight
D3-16NA: 6.4 oz. (180g) p. 353
D3-08TD1 weight
D3-08TD1: 4.2 oz. (120g) p. 353
DL305 CPUs and bases
DL330, DL330P and DL340 CPUs; 5 slot, 8 slot and 10 slot bases p. 23
Maximum wire size
12 AWG on 8 point modules; 16 AWG on 16 point modules p. 110
Module color bar
Blue for input modules, red for output modules, white for others p. 113
Handheld programmers
D3-HPP (RLL PLUS) and D3-HP (RLL only), on the CPU's built-in port p. 23
Status LEDs
I/O module status LEDs are logic side indicators p. 327

What this manual walks you through

  • D3-16NA specifications, derating chart and wiring diagram p. 123
  • D3-08TD1 specifications, derating chart and wiring diagram p. 133
  • Calculating the base power budget for I/O modules p. 93, 94, 95
  • Wiring field devices to the I/O modules p. 110
  • Adding external fuses to I/O wiring p. 111
  • Troubleshooting I/O modules p. 327
  • Reducing electrical noise p. 328

Good to know

  • Output modules cannot detect shorted or open output points; measure the voltage drop from the common to the suspect point. p. 327
  • Leakage current from an output device can create false input signals; a 10K to 20K ohm resistor in parallel usually corrects it. p. 327
  • Field device power may still be on the terminal block when the PLC is off; check it before removing the connector. p. 110
  • Exceeding the power budget may make the system operate unpredictably. p. 93
  • Drawing from the base 24 VDC output terminal should not exceed 100mA. p. 93

Questions this manual answers

How much base power does the D3-16NA draw?

Up to 100 mA from the 9V supply; typically 4 mA per ON point, 64 mA total. p. 94, 123

What current can each D3-08TD1 output switch?

0.5A per point; the outputs are current sinking NPN open collector on 5-24VDC. p. 133

Can the fuses in the D3-08TD1 be replaced?

No; it has one 3A fuse per common, listed as non-replaceable. p. 133

Why does a DL305 input turn on when the field device is off?

Leakage current from the connected output device can be large enough to turn on the input; a 10K to 20K ohm resistor in parallel usually fixes it. p. 327

What wire size fits DL305 I/O modules?

Up to 12 AWG on 8 point modules and up to 16 AWG on 16 point modules. p. 110

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. DL305 User Manual1
  2. Warning3
  3. Manual History5
    1. Chapter 1: Getting Started7
    2. Chapter 2: Installation and Safety Guidelines7
    3. Chapter 3: DL330/DL330P/DL340 CPU Specifications7
    4. Chapter 4: Bases, Expansion Bases, and I/O Configuration9
    5. Chapter 5: I/O Module Selection & Wiring Guidelines10
    6. Chapter 6: Discrete Input Modules10
    7. Chapter 7: Discrete Output Modules11
    8. Chapter 8: System Operation12
    9. Chapter 9: Programming Basics13
    10. Chapter 10: RLLPLUS Programming Basics14
    11. Chapter 11: Instruction Set15
    12. Chapter 12: RLLPLUS Instruction Set16
    13. Chapter 13: Maintenance and Troubleshooting17
    14. Appendix A: Quick Start Example18
    15. Appendix B: DL305 Error Codes18
    16. Appendix C: Instruction Execution Times18
    17. Appendix D: DL305 Product Weight Tables18
    18. Index18
  4. Chapter 1: Getting Started20
    1. Introduction21
    2. DL305 System Components23
    3. DirectLOGIC DL305 Family25
    4. DirectLOGIC Part Numbering System27
    5. A Few Steps to a Successful System29
  5. Chapter 2: Installation and Safety Guidelines32
    1. Safety Guidelines33
    2. Panel Design Specifications36
    3. Component Dimensions39
    4. Base Mounting Dimensions42
    5. Installing Components in the Base42
    6. I/O Wiring44
  6. Chapter 3: DL330/DL330P/DL340 CPU Specifications46
    1. Overview47
    2. CPU Hardware Features47
    3. CPU Specifications48
    4. Selecting CPU Memory Options49
155 more lines, from page 54 on
  1. DL330/DL330P CPU Setup54
    1. DL340 CPU Setup55
    2. DL340 Port Setup57
    3. Battery Backup59
    4. Installing the CPU60
    5. CPU Setup and System Functions61
  2. Chapter 4: Bases, Expansion Bases, and I/O Configuration68
    1. Understanding I/O Numbering and Module Placement Rules69
    2. Base Specifications and Wiring74
    3. Using Bases for Local or Expansion I/O Systems81
    4. Setting the Base Switches83
    5. Example I/O Configurations84
    6. I/O Configurations with a 5 Slot Local CPU Base85
    7. I/O Configurations with an 8 Slot Local CPU Base88
    8. I/O Configurations with a 10 Slot Local CPU Base89
    9. Calculating the Power Budget93
  3. Chapter 5: I/O Module Selection & Wiring Guidelines100
    1. I/O Selection Considerations101
    2. Sinking and Sourcing Circuits101
    3. DL305 Input Module Configuration Chart102
    4. DL305 Output Module Configuration Chart102
    5. Configuration #1: DL305 DC Current Sourcing Input Module103
    6. Configuration #2: DL305 DC Current Sinking/Sourcing Input Module103
    7. Configuration #3: DL305 DC Current Sinking Input Module104
    8. Configuration #4: DL305 AC/DC Input Module104
    9. Configuration #5: DL305 AC Input Module105
    10. Configuration #6: DL305 DC Current Sinking Output Module106
    11. Configuration #7: DL305 DC Current Sourcing Output Module106
    12. Configuration #8: DL305 AC/DC Current Sink/Source (Relay) Output Module107
    13. Configuration #9: DL305 AC Output Module107
    14. Solid State Field Device Wiring to DC Input Modules108
    15. Derating Characteristics109
    16. I/O Wiring Guidelines110
    17. Fuse Protection111
  4. Chapter 6: Discrete Input Modules112
    1. Discrete Input Module Identification and Terminology113
    2. D3-08ND2, 24 VDC Input Module115
    3. D3-16ND2-1, 24 VDC Input Module116
    4. D3-16ND2-2, 24 VDC Input Module Module117
    5. D3-16ND2F, 24 VDC Fast Response Input Module118
    6. F3-16ND3F, TTL/24 VDC Fast Response Input Module119
    7. D3-08NA-1, 110 VAC Input Module121
    8. D3-08NA-2, 220 VAC Input Module122
    9. D3-16NA, 110 VAC Input Module123
    10. D3-08NE3, 24 VAC/DC Input Module124
    11. D3-16NE3, 24 VAC/DC Input Module125
    12. D3-08SIM, Input Simulator126
  5. Chapter 7: Discrete Output Modules128
    1. Discrete Output Module Identification and Terminology129
    2. Relay Arc Suppression - DC and AC Applications131
    3. D3-08TD1, 24 VDC Output Module133
    4. D3-08TD2, 24 VDC Output Module134
    5. D3-16TD1-1, 24 VDC Output Module135
    6. D3-16TD1-2, 24 VDC Output Module136
    7. D3-16TD2, 24 VDC Output Module137
    8. D3-04TAS, 110-220 VAC Output Module138
    9. F3-08TAS, 250 VAC Isolated Output Module139
    10. F3-08TAS-1, 125 VAC Isolated Output Module140
    11. D3-08TA-1, 110-220 VAC Output Module141
    12. D3-08TA-2, 110-220 VAC Output Module142
    13. F3-16TA-2, 20-125 VAC Output Module143
    14. D3-16TA-2, 110-220 VAC Output Module144
    15. D3-08TR, Relay Output Module145
    16. F3-08TRS-1, Relay Output Module146
    17. F3-08TRS-2, Relay Output Module147
    18. D3-16TR, Relay Output Module148
  6. Chapter 8: System Operation150
    1. Introduction151
    2. CPU Operating System152
    3. Initial Mode Setting and Memory Initialization153
    4. Program Mode Operation155
    5. Run Mode Operation156
    6. I/O Response Time163
    7. CPU Scan Time Considerations165
    8. Memory Map168
    9. DL305 Aliases174
    10. I/O Point Bit Map178
    11. Control Relay Bit Map179
    12. Special Relays181
    13. Timer / Counter Registers and Contacts182
    14. Data Registers183
    15. Stage Control / Status Bit Map185
    16. Shift Register Bit Map186
    17. Special Registers187
  7. Chapter 9: Programming Basics188
    1. Introduction189
    2. Using Boolean Instructions190
    3. Using Timers195
    4. Using Counters196
    5. Using the Accumulator197
  8. Chapter 10: RLLPLUS Programming Basics202
    1. Introduction203
    2. An Example Machine204
    3. An RLL Solution205
    4. An RLLPLUS Solution206
    5. Stage Instruction Execution207
    6. Activating Stages209
    7. Using Outputs in Stages213
    8. Using Timers and Counters in Stages216
    9. Using Data Instructions in Stages218
    10. Using Comparative Contacts in Stages219
    11. Parallel Branching Concepts220
    12. Unusual Operations in Stages225
    13. Two Ways to View RLLPLUS Programs227
    14. Designing a Program Using RLLPLUS Instructions228
  9. Chapter 11: Instruction Set240
    1. Introduction241
    2. Boolean Instructions243
    3. Comparative Boolean Instructions258
    4. Timer, Counter, and Shift Register Instructions261
    5. Accumulator Load and Output Instructions264
    6. Accumulator Logic Instructions269
    7. Math Instructions273
    8. Bit Operation Instructions281
    9. Number Conversion Instructions283
    10. Program Control Instructions289
    11. Network Instructions291
    12. Message Instructions295
  10. Chapter 12: RLLPLUS Instruction Set296
    1. Introduction297
    2. Stage Instructions298
    3. Comparative Boolean Instructions307
    4. Timer, Counter, and Shift Register Instructions313
  11. Chapter 13: Maintenance andTroubleshooting318
    1. Maintenance319
    2. CPU Indicators320
    3. Power Indicator321
    4. RUN Indicator323
    5. CPU Indicator323
    6. BATT Indicator323
    7. Expansion Base Power324
    8. Testing Output Points325
    9. I/O Module Troubleshooting327
    10. Noise Troubleshooting328
    11. Machine Startup and Program Troubleshooting329
  12. Appendix A: Quick Start Example332
    1. Step 1: Unpack the DL305 Equipment333
    2. Step 2: Configure the 5-slot Base as the Local CPU Base334
    3. Step 3: Install the CPU and I/O Modules334
    4. Step 4: Wire the I/O Modules to the Field Devices335
    5. Step 5: Remove the Terminal Strip Access Cover335
    6. Step 6: Connect the Power Wiring336
    7. Step 7: Connect the Handheld Programmer337
    8. Step 8: Connect the Power Source338
    9. Step 9: Enter the Example Program338
  13. Appendix B: DL305 Error Codes340
    1. Error Code Table341
  14. Appendix C: Instruction Execution Times342
    1. Introduction343
    2. DL330 Instruction Execution Times345
    3. DL330P Instruction Execution Times347
    4. DL340 Instruction Execution Times349
  15. Appendix D: DL305 Product Weight Tables352
    1. Product Weight Table353
  16. Index354

From the PDF’s own bookmarks.

The whole text · 41 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Pages 5 to 115-11
  3. Pages 12 to 1612-16
  4. Pages 17 to 1917-19
  5. Chapter 1: Getting Started20-31
  6. Chapter 2: Installation and Safety Guidelines32-45
  7. Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 46 to 5346-53
  8. Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 54 to 6154-61
  9. Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 62 to 6762-67
  10. Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 68 to 7568-75
  11. Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 76 to 8376-83
  12. Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 84 to 9184-91
  13. Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 92 to 9992-99
  14. Chapter 5: I/O Module Selection & Wiring Guidelines100-111
  15. Chapter 6: Discrete Input Modules, pages 112 to 119112-119
  16. Chapter 6: Discrete Input Modules, pages 120 to 127120-127
  17. Chapter 7: Discrete Output Modules, pages 128 to 135128-135
  18. Chapter 7: Discrete Output Modules, pages 136 to 143136-143
  19. Chapter 7: Discrete Output Modules, pages 144 to 149144-149
  20. Chapter 8: System Operation, pages 150 to 159150-159
  21. Chapter 8: System Operation, pages 160 to 169160-169
  22. Chapter 8: System Operation, pages 170 to 179170-179
  23. Chapter 8: System Operation, pages 180 to 187180-187
  24. Chapter 9: Programming Basics188-201
  25. Chapter 10: RLLPLUS Programming Basics, pages 202 to 211202-211
  26. Chapter 10: RLLPLUS Programming Basics, pages 212 to 221212-221
  27. Chapter 10: RLLPLUS Programming Basics, pages 222 to 231222-231
  28. Chapter 10: RLLPLUS Programming Basics, pages 232 to 239232-239
  29. Chapter 11: Instruction Set, pages 240 to 249240-249
  30. Chapter 11: Instruction Set, pages 250 to 259250-259
  31. Chapter 11: Instruction Set, pages 260 to 269260-269
  32. Chapter 11: Instruction Set, pages 270 to 279270-279
  33. Chapter 11: Instruction Set, pages 280 to 289280-289
  34. Chapter 11: Instruction Set, pages 290 to 295290-295
  35. Chapter 12: RLLPLUS Instruction Set, pages 296 to 303296-303
  36. Chapter 12: RLLPLUS Instruction Set, pages 304 to 311304-311
  37. Chapter 12: RLLPLUS Instruction Set, pages 312 to 317312-317
  38. Chapter 13: Maintenance andTroubleshooting318-331
  39. Appendix A: Quick Start Example332-339
  40. Pages 340 to 351340-351
  41. Pages 352 to 357352-357

The file

Revision and size

Part no.D3-USER-M
RevisionRev. D, 1/2010
PublisherAutomationDirect
Pages357
PDF3.4 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
D3-USER-M

The first pages · 3 of 357

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 357
Page 2
Page 2of 357
Page 3
Page 3of 357

More documents · 1

For the same models