Manual · Koyo
DL305 User Manual
Manual357 pagesPDF 3.4 MB
User manual for the DirectLOGIC DL305 PLC system: DL330, DL330P and DL340 CPUs, bases, and I/O modules such as the D3-16NA and D3-08TD1.
Covers · 4 models
The models it covers
Summary
What is in it
The AutomationDirect user manual for the DL305 PLC family. It covers installation and safety, the DL330, DL330P and DL340 CPUs, bases and I/O configuration, I/O module selection and wiring, and a page per discrete module, including the D3-16NA 110 VAC input module and the D3-08TD1 24 VDC output module. Later chapters explain system operation, programming basics, RLLPLUS stage programming, the instruction sets, and maintenance and troubleshooting, with error codes in an appendix.
Its parts
- Getting Started
- Installation and Safety Guidelines
- DL330/DL330P/DL340 CPU Specifications
- Bases, Expansion Bases, and I/O Configuration
- I/O Module Selection & Wiring Guidelines
- Discrete Input Modules
- Discrete Output Modules
- System Operation
- Programming Basics
- RLLPLUS Programming Basics
- Instruction Set
- RLLPLUS Instruction Set
- Maintenance and Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
DL305 User Manual (Rev. D) for the DirectLOGIC DL305 PLC family: the DL330, DL330P and DL340 CPUs, bases, and the discrete and other I/O modules. It includes specification sheets and wiring diagrams for the D3-16NA 110 VAC input module and the D3-08TD1 24 VDC output module. It also covers installation, power budgets, programming, maintenance and troubleshooting.
- D3-16NA type
- D3-16NA: 110 VAC discrete input module for the DL305 p. 123
- D3-08TD1 type
- D3-08TD1: 24 VDC discrete output module, current sinking, NPN (open collector) p. 133
- D3-16NA field supply
- D3-16NA: 80-132VAC line and common on the wiring diagram p. 123
- D3-08TD1 load supply
- D3-08TD1: 5-24VDC; 0.5A per point p. 133
- D3-16NA base power
- D3-16NA: 9V, 100 mA max; typical 4 mA per ON point, 64 mA total p. 94, 123
- D3-08TD1 base power
- D3-08TD1: 9V 20 mA max; 24V 3 mA per point (24 mA max) p. 95, 133
- D3-08TD1 fuses
- D3-08TD1: one 3A fuse per common, non-replaceable p. 133
- D3-16NA weight
- D3-16NA: 6.4 oz. (180g) p. 353
- D3-08TD1 weight
- D3-08TD1: 4.2 oz. (120g) p. 353
- DL305 CPUs and bases
- DL330, DL330P and DL340 CPUs; 5 slot, 8 slot and 10 slot bases p. 23
- Maximum wire size
- 12 AWG on 8 point modules; 16 AWG on 16 point modules p. 110
- Module color bar
- Blue for input modules, red for output modules, white for others p. 113
- Handheld programmers
- D3-HPP (RLL PLUS) and D3-HP (RLL only), on the CPU's built-in port p. 23
- Status LEDs
- I/O module status LEDs are logic side indicators p. 327
What this manual walks you through
- D3-16NA specifications, derating chart and wiring diagram p. 123
- D3-08TD1 specifications, derating chart and wiring diagram p. 133
- Calculating the base power budget for I/O modules p. 93, 94, 95
- Wiring field devices to the I/O modules p. 110
- Adding external fuses to I/O wiring p. 111
- Troubleshooting I/O modules p. 327
- Reducing electrical noise p. 328
Good to know
- Output modules cannot detect shorted or open output points; measure the voltage drop from the common to the suspect point. p. 327
- Leakage current from an output device can create false input signals; a 10K to 20K ohm resistor in parallel usually corrects it. p. 327
- Field device power may still be on the terminal block when the PLC is off; check it before removing the connector. p. 110
- Exceeding the power budget may make the system operate unpredictably. p. 93
- Drawing from the base 24 VDC output terminal should not exceed 100mA. p. 93
Questions this manual answers
How much base power does the D3-16NA draw?
Up to 100 mA from the 9V supply; typically 4 mA per ON point, 64 mA total. p. 94, 123
What current can each D3-08TD1 output switch?
0.5A per point; the outputs are current sinking NPN open collector on 5-24VDC. p. 133
Can the fuses in the D3-08TD1 be replaced?
No; it has one 3A fuse per common, listed as non-replaceable. p. 133
Why does a DL305 input turn on when the field device is off?
Leakage current from the connected output device can be large enough to turn on the input; a 10K to 20K ohm resistor in parallel usually fixes it. p. 327
What wire size fits DL305 I/O modules?
Up to 12 AWG on 8 point modules and up to 16 AWG on 16 point modules. p. 110
Contents
Chapters and sections
Each line opens the PDF at its page.
- DL305 User Manual1
- Warning3
- Manual History5
- Chapter 1: Getting Started7
- Chapter 2: Installation and Safety Guidelines7
- Chapter 3: DL330/DL330P/DL340 CPU Specifications7
- Chapter 4: Bases, Expansion Bases, and I/O Configuration9
- Chapter 5: I/O Module Selection & Wiring Guidelines10
- Chapter 6: Discrete Input Modules10
- Chapter 7: Discrete Output Modules11
- Chapter 8: System Operation12
- Chapter 9: Programming Basics13
- Chapter 10: RLLPLUS Programming Basics14
- Chapter 11: Instruction Set15
- Chapter 12: RLLPLUS Instruction Set16
- Chapter 13: Maintenance and Troubleshooting17
- Appendix A: Quick Start Example18
- Appendix B: DL305 Error Codes18
- Appendix C: Instruction Execution Times18
- Appendix D: DL305 Product Weight Tables18
- Index18
- Chapter 1: Getting Started20
- Chapter 2: Installation and Safety Guidelines32
- Chapter 3: DL330/DL330P/DL340 CPU Specifications46
155 more lines, from page 54 on
- DL330/DL330P CPU Setup54
- Chapter 4: Bases, Expansion Bases, and I/O Configuration68
- Understanding I/O Numbering and Module Placement Rules69
- Base Specifications and Wiring74
- Using Bases for Local or Expansion I/O Systems81
- Setting the Base Switches83
- Example I/O Configurations84
- I/O Configurations with a 5 Slot Local CPU Base85
- I/O Configurations with an 8 Slot Local CPU Base88
- I/O Configurations with a 10 Slot Local CPU Base89
- Calculating the Power Budget93
- Chapter 5: I/O Module Selection & Wiring Guidelines100
- I/O Selection Considerations101
- Sinking and Sourcing Circuits101
- DL305 Input Module Configuration Chart102
- DL305 Output Module Configuration Chart102
- Configuration #1: DL305 DC Current Sourcing Input Module103
- Configuration #2: DL305 DC Current Sinking/Sourcing Input Module103
- Configuration #3: DL305 DC Current Sinking Input Module104
- Configuration #4: DL305 AC/DC Input Module104
- Configuration #5: DL305 AC Input Module105
- Configuration #6: DL305 DC Current Sinking Output Module106
- Configuration #7: DL305 DC Current Sourcing Output Module106
- Configuration #8: DL305 AC/DC Current Sink/Source (Relay) Output Module107
- Configuration #9: DL305 AC Output Module107
- Solid State Field Device Wiring to DC Input Modules108
- Derating Characteristics109
- I/O Wiring Guidelines110
- Fuse Protection111
- Chapter 6: Discrete Input Modules112
- Discrete Input Module Identification and Terminology113
- D3-08ND2, 24 VDC Input Module115
- D3-16ND2-1, 24 VDC Input Module116
- D3-16ND2-2, 24 VDC Input Module Module117
- D3-16ND2F, 24 VDC Fast Response Input Module118
- F3-16ND3F, TTL/24 VDC Fast Response Input Module119
- D3-08NA-1, 110 VAC Input Module121
- D3-08NA-2, 220 VAC Input Module122
- D3-16NA, 110 VAC Input Module123
- D3-08NE3, 24 VAC/DC Input Module124
- D3-16NE3, 24 VAC/DC Input Module125
- D3-08SIM, Input Simulator126
- Chapter 7: Discrete Output Modules128
- Discrete Output Module Identification and Terminology129
- Relay Arc Suppression - DC and AC Applications131
- D3-08TD1, 24 VDC Output Module133
- D3-08TD2, 24 VDC Output Module134
- D3-16TD1-1, 24 VDC Output Module135
- D3-16TD1-2, 24 VDC Output Module136
- D3-16TD2, 24 VDC Output Module137
- D3-04TAS, 110-220 VAC Output Module138
- F3-08TAS, 250 VAC Isolated Output Module139
- F3-08TAS-1, 125 VAC Isolated Output Module140
- D3-08TA-1, 110-220 VAC Output Module141
- D3-08TA-2, 110-220 VAC Output Module142
- F3-16TA-2, 20-125 VAC Output Module143
- D3-16TA-2, 110-220 VAC Output Module144
- D3-08TR, Relay Output Module145
- F3-08TRS-1, Relay Output Module146
- F3-08TRS-2, Relay Output Module147
- D3-16TR, Relay Output Module148
- Chapter 8: System Operation150
- Introduction151
- CPU Operating System152
- Initial Mode Setting and Memory Initialization153
- Program Mode Operation155
- Run Mode Operation156
- I/O Response Time163
- CPU Scan Time Considerations165
- Memory Map168
- DL305 Aliases174
- I/O Point Bit Map178
- Control Relay Bit Map179
- Special Relays181
- Timer / Counter Registers and Contacts182
- Data Registers183
- Stage Control / Status Bit Map185
- Shift Register Bit Map186
- Special Registers187
- Chapter 9: Programming Basics188
- Chapter 10: RLLPLUS Programming Basics202
- Introduction203
- An Example Machine204
- An RLL Solution205
- An RLLPLUS Solution206
- Stage Instruction Execution207
- Activating Stages209
- Using Outputs in Stages213
- Using Timers and Counters in Stages216
- Using Data Instructions in Stages218
- Using Comparative Contacts in Stages219
- Parallel Branching Concepts220
- Unusual Operations in Stages225
- Two Ways to View RLLPLUS Programs227
- Designing a Program Using RLLPLUS Instructions228
- Chapter 11: Instruction Set240
- Introduction241
- Boolean Instructions243
- Comparative Boolean Instructions258
- Timer, Counter, and Shift Register Instructions261
- Accumulator Load and Output Instructions264
- Accumulator Logic Instructions269
- Math Instructions273
- Bit Operation Instructions281
- Number Conversion Instructions283
- Program Control Instructions289
- Network Instructions291
- Message Instructions295
- Chapter 12: RLLPLUS Instruction Set296
- Chapter 13: Maintenance andTroubleshooting318
- Appendix A: Quick Start Example332
- Step 1: Unpack the DL305 Equipment333
- Step 2: Configure the 5-slot Base as the Local CPU Base334
- Step 3: Install the CPU and I/O Modules334
- Step 4: Wire the I/O Modules to the Field Devices335
- Step 5: Remove the Terminal Strip Access Cover335
- Step 6: Connect the Power Wiring336
- Step 7: Connect the Handheld Programmer337
- Step 8: Connect the Power Source338
- Step 9: Enter the Example Program338
- Appendix B: DL305 Error Codes340
- Appendix C: Instruction Execution Times342
- Appendix D: DL305 Product Weight Tables352
- Index354
The whole text · 41 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Pages 5 to 115-11
- Pages 12 to 1612-16
- Pages 17 to 1917-19
- Chapter 1: Getting Started20-31
- Chapter 2: Installation and Safety Guidelines32-45
- Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 46 to 5346-53
- Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 54 to 6154-61
- Chapter 3: DL330/DL330P/DL340 CPU Specifications, pages 62 to 6762-67
- Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 68 to 7568-75
- Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 76 to 8376-83
- Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 84 to 9184-91
- Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 92 to 9992-99
- Chapter 5: I/O Module Selection & Wiring Guidelines100-111
- Chapter 6: Discrete Input Modules, pages 112 to 119112-119
- Chapter 6: Discrete Input Modules, pages 120 to 127120-127
- Chapter 7: Discrete Output Modules, pages 128 to 135128-135
- Chapter 7: Discrete Output Modules, pages 136 to 143136-143
- Chapter 7: Discrete Output Modules, pages 144 to 149144-149
- Chapter 8: System Operation, pages 150 to 159150-159
- Chapter 8: System Operation, pages 160 to 169160-169
- Chapter 8: System Operation, pages 170 to 179170-179
- Chapter 8: System Operation, pages 180 to 187180-187
- Chapter 9: Programming Basics188-201
- Chapter 10: RLLPLUS Programming Basics, pages 202 to 211202-211
- Chapter 10: RLLPLUS Programming Basics, pages 212 to 221212-221
- Chapter 10: RLLPLUS Programming Basics, pages 222 to 231222-231
- Chapter 10: RLLPLUS Programming Basics, pages 232 to 239232-239
- Chapter 11: Instruction Set, pages 240 to 249240-249
- Chapter 11: Instruction Set, pages 250 to 259250-259
- Chapter 11: Instruction Set, pages 260 to 269260-269
- Chapter 11: Instruction Set, pages 270 to 279270-279
- Chapter 11: Instruction Set, pages 280 to 289280-289
- Chapter 11: Instruction Set, pages 290 to 295290-295
- Chapter 12: RLLPLUS Instruction Set, pages 296 to 303296-303
- Chapter 12: RLLPLUS Instruction Set, pages 304 to 311304-311
- Chapter 12: RLLPLUS Instruction Set, pages 312 to 317312-317
- Chapter 13: Maintenance andTroubleshooting318-331
- Appendix A: Quick Start Example332-339
- Pages 340 to 351340-351
- Pages 352 to 357352-357
The file


