The text of a manual · part 12 of 41

DL305 User Manual: Chapter 4: Bases, Expansion Bases, and I/O Configuration, pages 84 to 91

Pages 84 to 91 of 357, from DL305 User Manual

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PLC Direct D3-08TD1, PLC Direct D3-16NA, Koyo D3-08TD1 and Koyo D3-16NA

Page 84

Bases, Expansion Bases, and I/O Configuration

4--17

Example A BASE BASE 1,3 2

020 to 027

010 to 017

000 to 007

130 to 137

120 to 127

110 to 117

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 to 167

150 to 157

140 to 147

030 to 037

020 to 027

010 to 017

000 to 007

130 to 137

120 to 127

110 to 117

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 to 167

150 to 157

140 to 147

BASE BASE 1,3 2

Example B

BASE BASE 1,3 2

Examples Show Maximum I/O Points Available

C P U

DL305

Expansion Base DL305

Local CPU Base C P U

DL305

Expansion Base DL305

For the following examples the configurations using 16 point I/O modules are shown with the maximum I/O points supported so you can always reduce the I/O count in one of our examples and the configuration will still be valid. Substitution of 8 point I/O modules can be made in place of any of the 16 point modules without affecting the I/O numbering for any of the other I/O modules. When a 16 point module is replaced with a 8 point I/O module the last 8 I/O addresses of that 16 point module may or may not be useable in another slot location, depending on the system configuration used

DL305 User Manual, Rev. D

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

Local CPU Base

030 to 037

Bases and Expansion Bases

The following system configurations will allow you to quickly configure your system by using examples. These system configurations show the I/O numbering and the base switch settings for every valid base configuration for a DL305 system. When a 16 point I/O module is used the last 8 I/O addresses of each 16 point module 16 Point I/O Allocation Example could have been used in another base slot. In the illustration below Example A shows a 16 point module in the slot next to the CPU using address 000--007 and 100--107. The expansion I/O cannot use the last slot of the expansion base since it is assigned addresses 100--107 and the 16 point module next to the CPU has already used these addresses. Example B shows an 8 point module in the slot next to the CPU and an 8 point module in the last slot of the expansion base. Both examples are valid configurations .

Bases and Expansion Bases

Example I/O Configurations

Page 85

Bases and Expansion Bases

Bases and Expansion Bases

4--18

Bases, Expansion Bases, and I/O Configuration

I/O Configurations with a 5 Slot Local CPU Base The configurations below and on the next few pages show a 5 slot base with 8 point I/O modules, 16 point modules, one expansion base and two expansion bases. Switch settings

The 5 slot base has a toggle switch on the inside of the base between slots 4 and 5 which allows you to select: Type of Base

Switch Position

Local CPU

Base 1,3

First Expansion

Base 2*

Last Expansion

Base 1,3

*used only with a 5 slot local CPU base

5 Slot Base with 8 Point I/O

Total I/O: 32 030 to 037

020 to 027

010 to 017

000 to 007

030 to 037

020 to 027

010 to 017

000 to 007

130 to 137

120 to 127

110 to 117

100 to 107

C P U

DL305

C P U

DL305

BASE BASE 1,3 2

Total I/O: 64

Bases, Expansion Bases and I/O Configuration

5 Slot Base with 16 Point I/O

BASE BASE 1,3 2

DL305 User Manual, Rev. D

Page 86

Bases, Expansion Bases, and I/O Configuration

Total I/O: 72 020 to 027

010 to 017

000 to 007

100 to 107

070 to 077

060 to 067

050 to 057

030 to 037

020 to 027

010 to 017

000 to 007

130 to 137

120 to 127

110 to 117

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 to 167

150 to 157

140 to 147

C P U

DL305

BASE BASE 1,3 2

040 to 047

DL305

BASE BASE 1,3 2

5 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Bases and Expansion Bases

030 to 037

Bases and Expansion Bases

5 Slot Base and 5 Slot Expansion Base with 8 Point I/O

4--19

Total I/O: 128

BASE BASE 1,3 2

DL305

DL305

DL340 only

NOTE: If a 16pt module is used in the last two available slots of the expansion base, 160 through 177 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160--C177 in DirectSOFT.

DL305 User Manual, Rev. D

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

C P U

Page 87

Bases, Expansion Bases, and I/O Configuration

5 Slot Base and Two 5 Slot Expansion Bases with 8 Point I/O

Total I/O: 112 030 to 037

020 to 027

010 to 017

000 to 007

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

DL305

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

DL305

030 to 037

020 to 027

010 to 017

000 to 007

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 150 to to 167 157

140 to 147

120 to 127

110 to 117

C P U

DL305

BASE BASE 1,3 2

Bases and Expansion Bases

Bases and Expansion Bases

4--20

BASE BASE 1,3 2

BASE BASE 1,3 2

5 Slot Base and Two 5 Slot Expansion Bases with 16 and 8 Point I/O

Total I/O: 128

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

130 to 137

100 to 107 BASE BASE 1,3 2

C P U

DL305

DL305

DL340 only DL305

BASE BASE 1,3 2

NOTE: If a 16pt module is used in the last two available slots of the expansion base, 160 through 177 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160--C177 in DirectSOFT.

DL305 User Manual, Rev. D

Page 88

Bases, Expansion Bases, and I/O Configuration

4--21

The configurations below show an 8 slot base with 8 point I/O modules, 16 point modules, one 5 slot expansion base and two 5 slot expansion bases. 8 Slot Base with 8 Point I/O

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6

5

4 3

2

1 0

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

740 to 747

730 to 737

720 to 727

710 to 717

700 to 707

DL305

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6

5

4 3

2

1 0

740 to 747

730 to 737

720 to 727

700 to 707

DL305

C P U

DL305

C P U

DL305

C P U

DL305

Total I/O: 112 *See note below regarding points 160--167

8 Slot Base and 5 Slot Expansion Base with 8 Point I/O

060 to 067

Total I/O: 96 000 to 007

Total I/O: 152 *See note below regarding points 160--167

710 to 717

C P U

DL305

BASE BASE 1,3 2

NOTE: If a 16pt module is used in Slot 6, 160 through 167 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160--C167 in DirectSOFT.

DL305 User Manual, Rev. D

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

8 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Bases and Expansion Bases

8 Slot Base with 16 Point I/O

Total I/O: 56

Bases and Expansion Bases

I/O Configurations with an 8 Slot Local CPU Base

Page 89

Bases, Expansion Bases, and I/O Configuration

I/O Configurations with a 10 Slot Local CPU Base

Switch settings

Bases and Expansion Bases

Bases and Expansion Bases

4--22

The configurations below and on the next few pages show a 10 slot base with 8 point I/O modules, with 16 point modules, with a 5 slot expansion base and with a 10 slot expansion base. The 10 slot base has two jumper switches to select the base type and the address ranges to use. These switches can be found on the base between slots 3 and 4 (SW1) and slots 9 and 10 (SW2). Jumper switch SW1 is used to select if the base is a local CPU base or an expansion base. Jumper switch SW2 determines the I/O address range (100 -- 107 or 700 -- 707) for the 10th slot on the local CPU base. By selecting the address range of 700 to 707 for slot 10, it is possible to use a 16 point module next to the CPU (which uses the ranges of 000 to 007 and 100 to 107), however; the position of this switch will affect the I/O numbering for the expansion I/O if used. NOTE: Jumper switch SW2 must be set to “100 EXP” on the expansion base.

Last Slot Address Range 100 to 107

Total I/O: 72 Jumper SW2 100

700

Jumper SW1

EXP

EXP

Bases, Expansion Bases and I/O Configuration

100 to 107

Last Slot Address Range 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

C P U

CPU

DL305

Total I/O: 72 Jumper SW2 100

700

Jumper SW1

EXP

EXP 700 to 707

DL305 User Manual, Rev. D

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

C P U

DL305

CPU

Page 90

4--23

Bases, Expansion Bases, and I/O Configuration

The next two configurations show a local CPU base using 16 point I/O modules and the two possibilities for how to configure the base to use the maximum number of I/O points.

Configuration 1

Configuration 1 shows an 8 point I/O module the slot next to the CPU and the address range of 100--107 for the last slot. When jumper switch SW2 is set to the “100 EXP” position, the address range for the last slot is set to 100--107, thereby limiting the address range for the first module to 000--007. This means if you use this configuration, the first module must be an 8 point I/O module. You will have more available addresses for an expansion base as you will see in the example using a 10 slot expansion base. Configuration 1

Jumper SW2

Jumper SW1

100 EXP

700

EXP 100 to 107

*See note below regarding points 160--167 and 170--177.

Configuration 2

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

170 to 177

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

6 5

4

3 2

8 7 DL340 only

C P U

DL305

1 0

Configuration 2

Jumper SW2 700

Jumper SW1

100 EXP

EXP 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

170 to 177

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6 5

4

8 7 DL340 only

3 2

C P U

CPU

DL305

1 0

NOTE: If a 16pt module is used in Slot 6 for the DL330 or DL330P CPU, 160 through 167 will not be available for control relay assignments. If a 16pt module is used in Slot 6 and/or Slot 7 for a DL340 CPU, 160--167 and/or 170--177 are not available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160--C167/C170--C177 in DirectSOFT.

DL305 User Manual, Rev. D

Bases, Expansion Bases and I/O Configuration

Configuration 2 shows a 16 point I/O module in the slot next to the CPU and the address range of 700--707 for the last slot. This is the maximum I/O configuration for a 10 slot local CPU base. When jumper switch SW2 is set to the “700” position the address range for the last slot is set to 700--707 making addresses 000--007 and 100--107 available for use in the first slot. The position of jumper switch SW2 can limit the amount of I/O addresses available to the larger expansion bases since expansion I/O numbering would normally start with address 700. Total I/O: 136

*See note below regarding points 160--167 and 170--177.

000 to 007

CPU

Bases and Expansion Bases

Total I/O:128

Bases and Expansion Bases

10 Slot Expansion Base with 16 Point I/O

Page 91

Bases and Expansion Bases

4--24

Bases, Expansion Bases, and I/O Configuration

10 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Total I/O: 176 Jumper SW2 700

Jumper SW1

100 EXP

EXP 700 to 707

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

170 160 to to 177 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6 5

4

070 to 077

Bases and Expansion Bases

8 7 750 to 757

740 to 747

730 to 737

720 to 727

710 to 717

3 2

C P U

CPU

DL305

1 0 DL340 only

DL305

BASE BASE 1,3 2

Bases, Expansion Bases and I/O Configuration

NOTE: If a 16pt module is used in Slot 6 for the DL330 or DL330P CPU, 160 through 167 will not be available for control relay assignments. If a 16pt module is used in Slot 6 and/or Slot 7 for a DL340 CPU, 160--167 and/or 170--177 are not available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160--C167/C170--C177 in DirectSOFT.

DL305 User Manual, Rev. D