The text of a manual · part 6 of 6
DL405 Remote Master/Remote Slave D4-RM, D4-RS, and D4-RSDC, pages 51 to 60
Pages 51 to 60 of 60
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PLC Direct D4-RM and Koyo D4-RM
Page 51
B--2
Reserved Memory Tables for Remote I/O
Remote Input/Output Global (GX) Addresses
Appendix B Reserved Memory Tables
MSB
LSB
Address
17
16
15
14
13
12
11
10
7
6
5
4
3
2
1
0
017
016
015
014
013
012
011
010
007
006
005
004
003
002
001
000
V40000
037
036
035
034
033
032
031
030
027
026
025
024
023
022
021
020
V40001
057
056
055
054
053
052
051
050
047
046
045
044
043
042
041
040
V40002
077
076
075
074
073
072
071
070
067
066
065
064
063
062
061
060
V40003
117
116
115
114
113
112
111
110
107
106
105
104
103
102
101
100
V40004
137
136
135
134
133
132
131
130
127
126
125
124
123
122
121
120
V40005
157
156
155
154
153
152
151
150
147
146
145
144
143
142
141
140
V40006
177
176
175
174
173
172
171
170
167
166
165
164
163
162
161
160
V40007
217
216
215
214
213
212
211
210
207
206
205
204
203
202
201
200
V40010
237
236
235
234
233
232
231
230
227
226
225
224
223
222
221
220
V40011
257
256
255
254
253
252
251
250
247
246
245
244
243
242
241
240
V40012
277
276
275
274
273
272
271
270
267
266
265
264
263
262
261
260
V40013
317
316
315
314
313
312
311
310
307
306
305
304
303
302
301
300
V40014
337
336
335
334
333
332
331
330
327
326
325
324
323
322
321
320
V40015
357
356
355
354
353
352
351
350
347
346
345
344
343
342
341
340
V40016
377
376
375
374
373
372
371
370
367
366
365
364
363
362
361
360
V40017
417
416
415
414
413
412
411
410
407
406
405
404
403
402
401
400
V40020
437
436
435
434
433
432
431
430
427
426
425
424
423
422
421
420
V40021
457
456
455
454
453
452
451
450
447
446
445
444
443
442
441
440
V40022
477
476
475
474
473
472
471
470
467
466
465
464
463
462
461
460
V40023
517
516
515
514
513
512
511
510
507
506
505
504
503
502
501
500
V40024
537
536
535
534
533
532
531
530
527
526
525
524
523
522
521
520
V40025
557
556
555
554
553
552
551
550
547
546
545
544
543
542
541
540
V40026
577
576
575
574
573
572
571
570
567
566
565
564
563
562
561
560
V40027
617
616
615
614
613
612
611
610
607
606
605
604
603
602
601
600
V40030
637
636
635
634
633
632
631
630
627
626
625
624
623
622
621
620
V40031
657
656
655
654
653
652
651
650
647
646
645
644
643
642
641
640
V40032
677
76
675
674
673
672
671
670
667
666
665
664
663
662
661
660
V40033
717
716
715
714
713
712
711
710
707
706
705
704
703
702
701
700
V40034
737
736
735
734
733
732
731
730
727
727
742
724
723
722
721
720
V40035
757
756
755
754
753
752
751
750
747
746
745
744
743
742
741
740
V40036
777
776
775
774
773
772
771
770
767
766
765
764
763
762
761
760
V40037
Page 52
Reserved Memory Tables for Remote I/O
B--3
Standard Input (X) Addresses MSB
LSB
Address
16
15
14
13
12
11
10
7
6
5
4
3
2
1
0
017
016
015
014
013
012
011
010
007
006
005
004
003
002
001
000
V40400
037
036
035
034
033
032
031
030
027
026
025
024
023
022
021
020
V40401
057
056
055
054
053
052
051
050
047
046
045
044
043
042
041
040
V40402
077
076
075
074
073
072
071
070
067
066
065
064
063
062
061
060
V40403
117
116
115
114
113
112
111
110
107
106
105
104
103
102
101
100
V40404
137
136
135
134
133
132
131
130
127
126
125
124
123
122
121
120
V40405
157
156
155
154
153
152
151
150
147
146
145
144
143
142
141
140
V40406
177
176
175
174
173
172
171
170
167
166
165
164
163
162
161
160
V40407
217
216
215
214
213
212
211
210
207
206
205
204
203
202
201
200
V40410
237
236
235
234
233
232
231
230
227
226
225
224
223
222
221
220
V40411
257
256
255
254
253
252
251
250
247
246
245
244
243
242
241
240
V40412
277
276
275
274
273
272
271
270
267
266
265
264
263
262
261
260
V40413
317
316
315
314
313
312
311
310
307
306
305
304
303
302
301
300
V40414
337
336
335
334
333
332
331
330
327
326
325
324
323
322
321
320
V40415
357
356
355
354
353
352
351
350
347
346
345
344
343
342
341
340
V40416
377
376
375
374
373
372
371
370
367
366
365
364
363
362
361
360
V40417
417
416
415
414
413
412
411
410
407
406
405
404
403
402
401
400
V40420
437
436
435
434
433
432
431
430
427
426
425
424
423
422
421
420
V40421
457
456
455
454
453
452
451
450
447
446
445
444
443
442
441
440
V40422
477
476
475
474
473
472
471
470
467
466
465
464
463
462
461
460
V40423
Appendix B Reserved Memory Tables
17
Page 53
B--4
Reserved Memory Tables for Remote I/O
Standard Output (Y) Addresses
Appendix B Reserved Memory Tables
MSB
LSB
Address
17
16
15
14
13
12
11
10
7
6
5
4
3
2
1
0
017
016
015
014
013
012
011
010
007
006
005
004
003
002
001
000
V40500
037
036
035
034
033
032
031
030
027
026
025
024
023
022
021
020
V40501
057
056
055
054
053
052
051
050
047
046
045
044
043
042
041
040
V40502
077
076
075
074
073
072
071
070
067
066
065
064
063
062
061
060
V40503
117
116
115
114
113
112
111
110
107
106
105
104
103
102
101
100
V40504
137
136
135
134
133
132
131
130
127
126
125
124
123
122
121
120
V40505
157
156
155
154
153
152
151
150
147
146
145
144
143
142
141
140
V40506
177
176
175
174
173
172
171
170
167
166
165
164
163
162
161
160
V40507
217
216
215
214
213
212
211
210
207
206
205
204
203
202
201
200
V40510
237
236
235
234
233
232
231
230
227
226
225
224
223
222
221
220
V40511
257
256
255
254
253
252
251
250
247
246
245
244
243
242
241
240
V40512
277
276
275
274
273
272
271
270
267
266
265
264
263
262
261
260
V40513
317
316
315
314
313
312
311
310
307
306
305
304
303
302
301
300
V40514
337
336
335
334
333
332
331
330
327
326
325
324
323
322
321
320
V40515
357
356
355
354
353
352
351
350
347
346
345
344
343
342
341
340
V40516
377
376
375
374
373
372
371
370
367
366
365
364
363
362
361
360
V40517
417
416
415
414
413
412
411
410
407
406
405
404
403
402
401
400
V40520
437
436
435
434
433
432
431
430
427
426
425
424
423
422
421
420
V40521
457
456
455
454
453
452
451
450
447
446
445
444
443
442
441
440
V40522
477
476
475
474
473
472
471
470
467
466
465
464
463
462
461
460
V40523
Page 54
Reserved Memory Tables for Remote I/O
B--5
Control Relay (C) Addresses MSB
LSB
Address
16
15
14
13
12
11
10
7
6
5
4
3
2
1
0
017
016
015
014
013
012
011
010
007
006
005
004
003
002
001
000
V40600
037
036
035
034
033
032
031
030
027
026
025
024
023
022
021
020
V40601
057
056
055
054
053
052
051
050
047
046
045
044
043
042
041
040
V40602
077
076
075
074
073
072
071
070
067
066
065
064
063
062
061
060
V40603
117
116
115
114
113
112
111
110
107
106
105
104
103
102
101
100
V40604
137
136
135
134
133
132
131
130
127
126
125
124
123
122
121
120
V40605
157
156
155
154
153
152
151
150
147
146
145
144
143
142
141
140
V40606
177
176
175
174
173
172
171
170
167
166
165
164
163
162
161
160
V40607
217
216
215
214
213
212
211
210
207
206
205
204
203
202
201
200
V40610
237
236
235
234
233
232
231
230
227
226
225
224
223
222
221
220
V40611
257
256
255
254
253
252
251
250
247
246
245
244
243
242
241
240
V40612
277
276
275
274
273
272
271
270
267
266
265
264
263
262
261
260
V40613
317
316
315
314
313
312
311
310
307
306
305
304
303
302
301
300
V40614
337
336
335
334
333
332
331
330
327
326
325
324
323
322
321
320
V40615
357
356
355
354
353
352
351
350
347
346
345
344
343
342
341
340
V40616
377
376
375
374
373
372
371
370
367
366
365
364
363
362
361
360
V40617
417
416
415
414
413
412
411
410
407
406
405
404
403
402
401
400
V40620
437
436
435
434
433
432
431
430
427
426
425
424
423
422
421
420
V40621
457
456
455
454
453
452
451
450
447
446
445
444
443
442
441
440
V40622
477
476
475
474
473
472
471
470
467
466
465
464
463
462
461
460
V40623
517
516
515
514
513
512
511
510
507
506
505
504
503
502
501
500
V40624
537
536
535
534
533
532
531
530
527
526
525
524
523
522
521
520
V40625
557
556
555
554
553
552
551
550
547
546
545
544
543
542
541
540
V40626
577
576
575
574
573
572
571
570
567
566
565
564
563
562
561
560
V40627
617
616
615
614
613
612
611
610
607
606
605
604
603
602
601
600
V40630
637
636
635
634
633
632
631
630
627
626
625
624
623
622
621
620
V40631
657
656
655
654
653
652
651
650
647
646
645
644
643
642
641
640
V40632
677
76
675
674
673
672
671
670
667
666
665
664
663
662
661
660
V40633
717
716
715
714
713
712
711
710
707
706
705
704
703
702
701
700
V40634
737
736
735
734
733
732
731
730
727
727
742
724
723
722
721
720
V40635
Appendix B Reserved Memory Tables
17
Page 55
Appendix C Determining I/O Update Time
1C
Page 56
C--2
Determining I/O Update Time
Overview Since the Remote Master and the CPU operate asynchronously from one another, it is possible that the remote I/O points may not be updated on every CPU scan. Therefore, in some applications it may helpful to understand the amount of time required to update the remote I/O points. Depending on the number of I/O points used in your remote configuration and the baud rate you have selected for communication, your update time requirements will vary. This Appendix will show you how to estimate the total delay time for your system.
Appendix C Determining I/O Update
NOTE: In most situations, this delay will be so small that either it makes no difference to the particular application or the mechanical speeds of the field devices are slower than the delay itself. If you have an application that requires a thorough understanding of the time delay, you can use the following information in order to calculate the delay: S Baud Rate, this is the communication baud rate that you selected with the dipswitch settings on the remote master and remote slaves. S CPU Scan Time, this is the total CPU scan time. The easiest way is to use AUX53 from a DL405 Handheld Programmer, or use the Diagnostics option under the PLC menu in our DirectSOFT Programming Software. This Use the respective specifications in the User’s Manual. You can also use the DL405 User Manual to calculate the scan time, but this is often very time consuming. If you use the User Manual, you will have to estimate this time, because it is dependent on the main program length, and number of I/O points in the local and expansion bases as well. S Remote Master Scan, this is the time required for the Remote Master to scan the individual Slave stations to update the status of the I/O modules. Use the formula and table shown on the following page. S Module ON to OFF, OFF to ON Response Time, this is the amount of time that the module requires to see a transition in status. For example, when a switch connected to an input module closes, it can take a few milliseconds (1--12 typical) before the module actually makes the transition from OFF to ON. The easiest way to find this information is from the module specifications in the respective User Manuals. This basic information is also available in the specifications of the Sales Catalog. S Total Delay Time, this is the total delay time that takes all of the above factors into consideration. There are several formulas that can be used to calculate this delay time. See the formulas on Page C5 of this Appendix. Once you have selected the formula applicable to your system, you will use the information you have gathered for the above items to calculate the total system delay time. Since each application is different, we cannot possibly show all of the options for the CPU scan time or the possible module response delays. You can easily find this information in other publications. However, the next few pages will show you how to calculate the delay time for the Remote Master Scan. Also, we show the total delay time for our example system that was used earlier in this manual.
Page 57
Determining I/O Update Time
C--3
Remote I/O Update Table The table shown below shows you how much time is required for the Remote Master Module to update its I/O data to its internal buffers. Remember from earlier reading in this chapter that the remote I/O scan and CPU scan are asynchronous. The CPU may be looking at the master module’s internal buffers several times before the master actually has enough time to write new data there. This chart shows the maximum amount of delay based on the number of I/O points being used. No. of Remote I/O Points
Update Time Required 38.4 kBaud
3.64ms
1.82ms
5.72 ms
2.86 ms
9.88 ms
4.94 ms
18.20 ms
9.10 ms
160 192 224 256
22.36 ms
11.18 ms
26.52 ms
13.26 ms
30.68 ms
15.34 ms
34.84 ms
17.42 ms
288 320 352 384
39.00 ms
19.50 ms
43.16 ms
21.58 ms
47.32 ms
23.66 ms
51.48 ms
25.74 ms
416 448 480 512
55.64 ms
27.82 ms
59.80 ms
29.90 ms
63.96 ms
31.98 ms
68.12 ms
34.06 ms
16 32 64 128
Remote Scan Time You can figure out the amount of time required for the remote I/O scan update with Formula the following formula: TRS = Time from Above Table + (2 ms x No. of Slaves) Example: Given a 38.4 kB system with a total of 128 remote points and 3 slaves. TRS = 9.10 ms + (2 ms x 3) = 15.10 ms
Appendix C Determining I/O Update
19.2 kBaud
Page 58
C--4
Determining I/O Update Time
Calculating Total Delay for the System Now that you have calculated the time required for the Remote Master to go through its scan cycle and update its internal buffer area, we need to add this time to other delay times inherent in the overall system. Below is an example where a remote input changes a remote output. Example Where A Remote Input Changes a Remote Output CPU Scan
Inputs from slot 1 of 1st remote slave in CPU Image Area
X60 X61
Part of program that is executed
Appendix C Determining I/O Update
X60
Y43
Inputs from slot 1 of 1st remote slave in Remote Master Buffer read
X60 X61
X62
X62
X63 X64 X65 X66 X67
X63 X64 X65 X66 X67
Outputs for slot 3 of 1st remote slave in CPU Image Area
Outputs for slot 3 of 1st remote slave in Remote Master Buffer write
Y40 Y41
Y40 Y41
Y42
Y42
Y43 Y44 Y45 Y46 Y47
Y43 Y44 Y45 Y46 Y47
Remote Scan read
Remote Slave #1 8 8 8 8
I I OO X60-X67
X60
INPUT write
Remote Slave #1 8 8 8 8
I I OO Y40-Y47
Y43
OUTPUT
The above drawing could be simplified schematically to look like this: Remote Input CPU X60
Remote Output Y43
The table on the adjacent page gives you a table that shows the formula for calculating the overall system delay for this scenario. It also shows you formulae for two other possible scenarios.
Page 59
Determining I/O Update Time Total Delay Time Formulas
C--5
The following table provides delay formulas for three different configuration scenarios. Notice that that there are two sets of formulas for each scenario. The formula chosen depends on whether the CPU scan time is greater than or less than the Remote Master scan time. There are several variables used in the formulas. The following descriptions will help you understand them. S TCS, CPU scan time. You can use DirectSOFT or a Handheld Programmer to determine this time, or you can estimate the time required by using the DL405 User Manual. S TRS, Remote Master scan time. Use the table and formula shown previously to determine this time. S TIN and TOUT, Module response delay time. You can find this information from the module specifications tables which are usually found in the DL405 User Manual.
Remote Input to Remote Output remote Input
CPU
TRS = TCS
TRS > TCS remote output
TIN + 4(TRS)+6(TCS) +TOUT
TIN + 4(TCS) +TOUT
TIN + 2(TRS)+4(TCS) +TOUT
Appendix C Determining I/O Update
TIN + 6(TCS) +TOUT
Local Input to Remote Output local Input
CPU remote output
Remote Input to Local Output remote Input local CPU output
The following page will show you how to use one of the formulas to calculate the delay time for our example system.
Page 60
C--6
Determining I/O Update Time
Delay Time Example
The following example shows you how to calculate the total time it takes for a remote input to be read and later updated by the CPU scan; and then, a remote output taking place at the remote base. We have used the same configuration as shown throughout this text which features 3 remote slaves, 1 master and 128 remote I/O points, communicating at 38.4 kBaud. EXAMPLE: 38.4 kBaud, D4-440, X60 causing a response by Y43. MasterModule
Main Base with Master Can go in any slot
CPU and PS
16
16
16
16
16
I
I
I
O
O
X0-X17 V40400
X20-X37 V40401
X40-X57 Y0-Y17 Y20-Y37 V40402 V40500 V40501
1st Remote 8
I
8
8
8
I
O
O
Appendix C Determining I/O Update
X60-X67 X70-X77 V40403
Slave Module
32 I/O points
Y40-Y47 Y50-Y57 V40502
2nd Remote
16
16
16
16
I
I
O
O
X100-X117 X120-X137 Y60-Y77 V40404 V40405 V40503
Slave Module
64 I/O points
Y100-Y117 V40504
3rd Remote 8
I
8
8
8
I
O
O
X140-X147 X150-X157 Y120-Y127 Y130-Y137 V40406 V40505
Slave Module
32 I/O points Total = 128 I/O points
Given that CPU scan (TCS) is estimated to be 50 ms. TIN = Maximum response input module time (08ND3S) = 12 ms TOUT = Maximum response output module time (08TD1) = 1 ms TRS = 9.10 ms + (2ms x3) = 15.10 ms < TCS Total Delay for Configuration = TIN + 6(TCS) +TOUT = 12 ms + 6(50 ms) + 1 ms = 313 ms