The text of a manual · part 1 of 9
MC1000 Series Installation and Operation Manual, pages 1 to 10
Pages 1 to 10 of 82
The original document is the PDF (297 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the AC Tech M1420B and Lenze M1420B
Page 1
AC Tech member of the Lenze Group
Drive for Global Excellence
MC1000 Series Installation and Operation Manual
Page 2
Manual Number: M101Q-e1
TABLE OF CONTENTS 1.0
GENERAL....................................................................................................... 1 PRODUCTS COVERED IN THIS MANUAL.................................................. 1 PRODUCT CHANGES..................................................................................... 1 WARRANTY.................................................................................................... 1 RECEIVING..................................................................................................... 1 CUSTOMER MODIFICATION....................................................................... 1
2.0
MC1000 SPECIFICATIONS........................….............………...........…...... 2
3.0
MC1000 MODEL DESIGNATION CODE.................................…..…........ 3
4.0
MC1000 DIMENSIONS....................................................................….......... 4
5.0
MC1000 RATINGS...........................................................................….......... 8
6.0
THEORY......................................................................................................... 12 DESCRIPTION OF AC MOTOR OPERATION.............................................. 12 DRIVE FUNCTION DESCRIPTION...............................……........................ 14
7.0
INSTALLATION............................................................................................ 16
8.0
INPUT AC REQUIREMENTS...................................................................... 18
9.0
VOLTAGE SELECTION............................................................................... 19
10.0
POWER WIRING........................................................................................... 20
11.0
MC1000 POWER WIRING DIAGRAM....................................................... 21
12.0
INITIAL POWER UP..................................................................................... 22
13.0
KEYPAD CONTROL..................................................................................... 24 KEYPAD FUNCTIONS......................................................................….......... 24 MC1000 DISPLAY.............................................................................….......... 25
14.0
CONTROL WIRING...................................................................................... 30 GENERAL........................................................................................................ 30 START/STOP AND SPEED CONTROL......................................................... 31
15.0
MC1000 CONTROL WIRING DIAGRAMS................................................ 37 MC1000 TERMINAL STRIP........................................................................... 37 TWO-WIRE START/STOP CONTROL.......................................................... 38 THREE-WIRE START/STOP CONTROL...................................................... 39 SPEED POT AND PRESET SPEED CONTROL............................................. 40
16.0
PROGRAMMING THE MC1000 DRIVE.................................................... 41 PROGRAMMING THE PARAMETERS......................................................... 41 PARAMETER ACCESS USING SPEED DIAL............................................... 43
17.0
PARAMETER MENU.................................................................................... 44
18.0
DESCRIPTION OF PARAMETERS............................................................ 47
19.0
TROUBLESHOOTING.................................................................................. 73
20.0
USER SETTING RECORD............................................................................75
Page 3
1.0
GENERAL
1.1
PRODUCTS COVERED IN THIS MANUAL This manual covers the AC Tech MC1000 Series Variable Frequency Drive.
1.2
PRODUCT CHANGES AC Technology Corporation reserves the right to discontinue or make modifications to the design of its products and manuals without prior notice, and holds no obligation to make modifications to products sold previously. AC Technology Corporation also holds no liability for losses of any kind which may result from this action. Instruction manuals with the most up-to-date information are available for download from the AC Tech website (www.actechdrives.com).
1.3
WARRANTY AC Technology Corporation warrants the MC Series AC motor control to be free of defects in material and workmanship for a period of eighteen months from the date of sale to the user, or two years from the date of shipment, which ever occurs first. An MC Series control, or any component contained therein, which under normal use, becomes defective within the stated warranty time period, shall be returned to AC Technology Corporation, freight prepaid, for examination (contact AC Technology Corporation for authorization prior to returning any product). AC Technology Corporation reserves the right to make the final determination as to the validity of a warranty claim, and sole obligation is to repair or replace only components which have been rendered defective due to faulty material or workmanship. No warranty claim will be accepted for components which have been damaged due to mishandling, improper installation, unauthorized repair and/or alteration of the product, operation in excess of design specifications or other misuse, or improper maintenance. AC Technology Corporation makes no warranty that its products are compatible with any other equipment, or to any specific application, to which they may be applied and shall not be held liable for any other consequential damage or injury arising from the use of its products. This warranty is in lieu of all other warranties, expressed or implied. No other person, firm or corporation is authorized to assume, for AC Technology Corporation, any other liability in connection with the demonstration or sale of its products.
1.4
RECEIVING Inspect all cartons for damage which may have occurred during shipping. Carefully unpack equipment and inspect thoroughly for damage or shortage. Report any damage to carrier and/or shortages to supplier. All major components and connections should be examined for damage and tightness, with special attention given to PC boards, plugs, knobs and switches.
1.5
CUSTOMER MODIFICATION AC Technology Corporation, its sales representatives and distributors, welcome the opportunity to assist our customers in applying our products. Many customizing options are available to aid in this function. AC Technology Corporation cannot assume responsibility for any modifications not authorized by its engineering department.
1
Page 4
2.0
MC1000 SPECIFICATIONS Storage Temperature
-20° to 70° C
Ambient Operating Temperature (With 2.5, 6, and 8 kHz carrier, derate for higher carriers)
Chassis Type 1 (IP 31) Type 4 (IP 65) Type 12 (IP 54)
Ambient Humidity
Less than 95% (non-condensing)
Altitude
3300 feet (1000 m) above sea level without derating
Input Line Voltages
240/120 Vac, 240/200 Vac, 480/400 Vac, and 590/480 Vac
Input Voltage Tolerance
+10%, -15%
Input Frequency Tolerance
48 to 62 Hz
Output Wave Form
Sine Coded PWM
Output Frequency
0-120 Hz, Optional up to 1000 Hz
Carrier Frequency
2.5 kHz to 14 kHz
Frequency Stability
+0.00006% / °C
Service Factor
1.00
Efficiency
> 97% throughout speed range
Power Factor (displacement)
> 0.96
Overload Current Capacity
150% of output rating for 60 seconds 180% of output rating for 30 seconds
Speed Reference Follower
0-10 VDC, 4-20 mA
Control Voltage
15 VDC
Analog Outputs
0 - 10 VDC, or 2 - 10 VDC Proportional to speed and load
Digital Outputs
Form C relay: 2 A at 28 VDC or 120 Vac Open-collector outputs: 40 mA at 30 VDC
2
-10° to 55° C -10° to 50° C -10° to 40° C -10° to 40° C
Page 5
3.0
MC1000 MODEL DESIGNATION CODE The model number of an MC1000 Series drive gives a full description of the basic drive unit (see example below). EXAMPLE: M1450BP (MC1000, 480 Vac, 5 HP, Type 1 Enclosure, with a Remote Keypad Assembly)
M1
4
50
B
Series: M1 = M1000 Series Variable Speed AC Motor Drive Input Voltage: 1 = 240/120 Vac (For 110, 115, 120, 230 and 240 Vac; 50 or 60 Hz) 2 = 240/200 Vac (For 208, 230, and 240 Vac; 50 or 60 Hz) 4 = 480/400 Vac (For 380, 415, 440, 460 and 480 Vac; 50 or 60 Hz) 5 = 590/480 Vac (For 440, 460, 480, 575 and 600 Vac; 50 or 60 Hz) Rating: 03 = ¼ HP (0.18 kW) 50 / 51 = 5 HP (3.7 kW)
300 = 30 HP (22 kW)
05 = ½ HP (0.37 kW)
75 = 7½ HP (5.5 kW)
400 = 40 HP (30 kW)
10 = 1 HP (0.75 kW)
100 = 10 HP (7.5 kW)
500 = 50 HP (37.5 kW)
15 = 1½ HP (1.1 kW)
150 = 15 HP (11 kW)
600 = 60 HP (45 kW)
20 = 2 HP (1.5 kW)
200 = 20 HP (15 kW)
30 = 3 HP (2.2 kW)
250 = 25 HP (18.5 kW)
Input Phase: S = Single phase input only. No character indicates three phase input only Enclosure Type: A = Chassis - Open Enclosure with Cover Removed B = NEMA 1 - General Purpose, vented C = NEMA 4 - Water-tight and Dust-tight D = NEMA 12 - Oil-tight and Dust-tight E = NEMA 4X - Water-tight, Dust-tight, and Corrosion Resistant (Stainless Steel) Standard Options: H = Additional Form C Relay circuit board J = Dynamic Braking circuit board K = Dynamic Braking & Additional Form C Relay board (not available on all HP sizes - consult factory) No character when this type of option is not specified Interface Options: P = Remote keypad assembly No character when this type of option is not specified
3
P
Page 6
4.0
MC1000 DIMENSIONS
4.1
CHASSIS AND TYPE 1 ENCLOSED W
D
R
Q
Q
H
W
Conduit Holes: S Dia. 0.88" Dia.
U V 1.00"
S Dia. P N
IF W = 10.26" T = 0.28" U = 0.44" V = 0.24"
R
T Dia. Slot
IF W < 7.86" T = 0.20" U = 0.34" V = 0.19"
Mounting Tab Detail
HP (kW) 0.25 (0.18)
INPUT VOLTAGE
MODEL
H
W
D
N
P
Q
R
S
240 / 120
M1103S
7.50
4.70
3.33
2.35
1.60
1.37
5.50
0.88
0.5
240 / 120
M1105S
7.50
6.12
3.63
3.77
1.80
1.37
5.50
0.88
(0.37)
240
M1205S
7.50
4.70
3.63
2.35
1.90
1.37
5.50
0.88 0.88
240 / 200
M1205
7.50
4.70
3.63
2.35
1.90
1.37
5.50
1
240 / 120
M1110S
7.50
6.12
4.22
3.77
2.40
1.37
5.50
0.88
(0.75)
240
M1210S
7.50
4.70
4.33
2.35
2.60
1.37
5.50
0.88
240 / 200
M1210
7.50
4.70
4.33
2.35
2.60
1.37
5.50
0.88
480 / 400
M1410
7.50
4.70
3.63
2.35
1.90
1.37
5.50
0.88 0.88
590
M1510
7.50
4.70
3.63
2.35
1.90
1.37
5.50
1.5
240 / 120
M1115S
7.50
6.12
4.22
3.77
2.40
1.37
5.50
0.88
(1.1)
240
M1215S
7.50
6.12
4.22
3.77
2.40
1.37
5.50
0.88
240 / 200
M1215
7.50
4.70
4.33
2.35
2.60
1.37
5.50
0.88
2
240
M1220S
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
(1.5)
240 / 200
M1220
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
480 / 400
M1420
7.50
6.12
4.22
3.77
2.40
1.37
5.50
0.88
590
M1520
7.50
6.12
4.22
3.77
2.40
1.37
5.50
0.88
4
Page 7
DIMENSIONS - CHASSIS AND TYPE 1 ENCLOSED (continued) HP (kW)
INPUT VOLTAGE
MODEL
H
W
D
N
P
Q
R
S
3
240
M1230S
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
(2.2)
240 / 200
M1230
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
480 / 400
M1430
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
590
M1530
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
5
240 / 200
M1250
7.88
7.86
5.94
5.13
3.95
1.50
5.88
1.13
(3.7)
480 / 400
M1450
7.50
6.12
5.12
3.77
3.30
1.37
5.50
0.88
590
M1551
7.88
7.86
5.94
5.13
3.95
1.50
5.88
1.13
7.5
240 / 200
M1275
9.38
7.86
6.84
3.93
4.19
2.00
5.88
1.13
(5.5)
480 / 400
M1475
9.38
7.86
6.25
5.13
3.95
1.50
7.38
1.13
590
M1575
9.38
7.86
6.25
5.13
3.95
1.50
7.38
1.13
10
240 / 200
M12100
11.25
7.86
6.84
3.93
4.19
2.00
7.75
1.38
(7.5)
480 / 400
M14100
9.38
7.86
6.84
3.93
4.19
2.00
5.88
1.13
590
M15100
9.38
7.86
7.40
3.93
4.19
2.00
5.88
1.13
15
240 / 200
M12150
12.75
7.86
6.84
3.93
4.19
2.00
9.25
1.38
(11)
480 / 400
M14150
11.25
7.86
6.84
3.93
4.19
2.00
7.75
1.38
590
M15150
12.75
7.86
6.84
3.93
4.19
2.00
9.25
1.38
20
240 / 200
M12200
12.75 10.26
7.74
5.13
5.00
2.50
9.25
1.38
(15)
480 / 400
M14200
12.75
7.86
6.84
3.93
4.19
2.00
9.25
1.38
590
M15200
12.75
7.86
7.40
3.93
4.19
2.00
9.25
1.38
25
240 / 200
M12250
15.75 10.26
8.35
5.13
5.00
2.50
12.25
1.38
(18.5)
480 / 400
M14250
12.75 10.26
7.74
5.13
5.00
2.50
9.25
1.38
590
M15250
12.75 10.26
7.74
5.13
5.00
2.50
9.25
1.38
30
240 / 200
M12300
15.75 10.26
8.35
5.13
5.00
2.50
12.25
1.38
(22)
480 / 400
M14300
12.75 10.26
7.74
5.13
5.00
2.50
9.25
1.38
590
M15300
12.75 10.26
8.25
5.13
5.00
2.50
9.25
1.38
40
480/400
M14400
15.75 10.26
8.35
5.13
5.00
2.50
12.25
1.38
(30)
590
M15400
15.75 10.26
8.35
5.13
5.00
2.50
12.25
1.38
50
480/400
M14500
19.75 10.26
8.55
5.13
5.75
2.50
16.25
1.75
(37.5)
590
M15500
19.75 10.26
8.55
5.13
5.75
2.50
16.25
1.75
60
480/400
M14600
19.75 10.26
8.55
5.13
5.75
2.50
16.25
1.75
(45)
590
M15600
19.75 10.26
8.55
5.13
5.75
2.50
16.25
1.75
5
Page 8
4.2
TYPE 4, 4X, AND 12 ENCLOSED
W
D
R
H
W
Conduit Holes: Q
Q
S Dia. 0.88" Dia. S Dia.
U V 1.00"
P
IF W > 10.26" T = 0.28" U = 0.44" V = 0.24"
R
T Dia. Slot
IF W < 7.86" T = 0.20" U = 0.34" V = 0.19"
N Mounting Tab Detail
HP (kW) 0.25 (0.18) 0.5 (0.37) 1 (0.75)
1.5 (1.1) 2 (1.5)
INPUT VOLTAGE
MODEL
H
W
D
N
P
Q
R
S
240 / 120
M1103S
7.88
6.12
3.63
3.06
2.00
1.37
5.88
0.88
240 / 120
M1105S
7.88
7.86
3.75
4.80
2.10
1.37
5.88
0.88
240
M1205S
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
240 / 200
M1205
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
240 / 120
M1110S
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
240
M1210S
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
240 / 200
M1210
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
480 / 400
M1410
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
590
M1510
7.88
6.12
4.35
3.06
2.70
1.37
5.88
0.88
240 / 120
M1115S
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88 0.88
240
M1215S
7.88
7.86
4.90
4.80
3.25
1.37
5.88
240 / 200
M1215
7.88
6.12
5.25
3.06
3.60
1.37
5.88
0.88
240
M1220S
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
240 / 200
M1220
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
480 / 400
M1420
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
590
M1520
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
6
Page 9
DIMENSIONS - TYPE 4, 4X, AND 12 ENCLOSED (continued)
HP (kW)
INPUT VOLTAGE
MODEL
H
W
D
N
P
Q
R
S
3
240
M1230S
7.88
7.86
5.90
4.80
4.25
1.37
5.88
0.88
(2.2)
240 / 200
M1230
7.88
7.86
5.90
4.80
4.25
1.37
5.88
0.88
480 / 400
M1430
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
590
M1530
7.88
7.86
4.90
4.80
3.25
1.37
5.88
0.88
5
240 / 200
M1250
9.75
10.26
7.20
5.13
5.25
2.00
7.75
1.13
(3.7)
480 / 400
M1450
7.88
7.86
5.90
4.80
4.25
1.37
5.88
0.88
590
M1550
7.88
7.86
5.90
4.80
4.25
1.37
5.88
0.88
7.5
240 / 200
M1275
11.75 10.26
8.35
5.13
5.75
2.00
9.75
1.13
(5.5)
480 / 400
M1475
9.75
10.26
7.20
5.13
5.25
2.00
7.75
1.13
590
M1575
9.75
10.26
7.20
5.13
5.25
2.00
7.75
1.13
10
240 / 200
M12100
13.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
(7.5)
480 / 400
M14100
11.75 10.26
8.35
5.13
5.75
2.00
9.75
1.13
590
M15100
11.75 10.26
8.35
5.13
5.75
2.00
9.75
1.13
15
240 / 200
M12150
15.75 10.26
8.35
5.13
5.75
2.00
13.75
1.38
(11)
480 / 400
M14150
13.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
M15150
13.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
20
240 / 200
M12200* 15.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
(15)
480 / 400
M14200
15.75 10.26
8.35
5.13
5.75
2.00
13.75
1.38
590
M15200
15.75 10.26
8.35
5.13
5.75
2.00
13.75
1.38
M12250* 20.25 10.26
8.35
5.13
5.75
2.00
16.25
1.38
590
25
240 / 200
(18.5)
480 / 400
M14250* 15.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
590
M15250* 15.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
30
240 / 200
M12300* 20.25 10.26
8.35
5.13
5.75
2.00
16.25
1.38
(22)
480 / 400
M14300* 15.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
590
M15300* 15.75 10.26
8.35
5.13
5.75
2.00
11.75
1.38
40
480 / 400
M14400* 20.25 10.26
8.35
5.13
5.75
2.00
16.25
1.38
(30)
590
M15400* 20.25 10.26
8.35
5.13
5.75
2.00
16.25
1.38
50
480 / 400
M14500* 21.00 13.72
8.35
5.13
6.10
2.00
16.25
1.38
(37.5)
590
M15500* 21.00 13.72
8.35
5.13
6.10
2.00
16.25
1.38
60
480 / 400
M14600* 21.00 13.72
8.35
5.13
6.10
2.00
16.25
1.38
(45)
590
M15600* 21.00 13.72
8.35
5.13
6.10
2.00
16.25
1.38
* MODELS AVAILABLE IN NEMA 12 ONLY.
7
Page 10
5.0
MC1000 RATINGS The following tables indicate the input and output ratings of the MC1000 Series drive. NOTE: The output current ratings are based on operation at carrier frequencies of 8 kHz and below. At full ambient temperature, operation at carrier frequencies above 8 kHz require derating the drive by multiplying the output current rating by the following factors: 0.94 at 10 kHz, 0.89 at 12 kHz, and 0.83 at 14 kHz. Refer to Parameter 23 - CARRIER in Section 18.0 - DESCRIPTION OF PARAMETERS.
M1100 SERIES RATINGS MODEL MODEL
FOR MOTORS
NUMBER
RATED
INPUT
OUTPUT
(120 / 240 Vac, 50 - 60 Hz)
(0 - 230 Vac)
NOMINAL
NOMINAL
INPUT
CURRENT
POWER
CURRENT
POWER
(NOTE 1)
HP kW
PHASE
(AMPS)
(KVA)
(AMPS)
(KVA)
M1103S
0.25
0.18
1
6.0 / 3.0
0.72
1.4 / 1.4
0.56
M1105S
0.5
0.37
1
9.2 / 4.6
1.1
2.2 / 2.2
0.88
M1110S
1
0.75
1
16.2 / 8.1
1.9
4.0 / 4.0
1.6
M1115S
1.5
1.1
1
21 / 10.4
2.5
5.2 / 5.2
2.1
NOTE 1:
See Section 3.0 for model number breakdown.
NOTE 2:
See Section 8.0 for recommended fuse type.
8