Page 11

M1200 SERIES RATINGS MODEL MODEL

FOR MOTORS

NUMBER

RATED

INPUT

OUTPUT

(200 / 240 Vac, 50 - 60 Hz)

(0 - 200 / 230 Vac)

NOMINAL

NOMINAL

INPUT

CURRENT

POWER

CURRENT

POWER

(NOTE 1)

HP kW

PHASE

(AMPS)

(KVA)

(AMPS)

(KVA)

M1205S

0.5

0.37

1

5.8 / 5.0

1.2

2.5 / 2.2

0.9

M1205

0.5

0.37

3

3.1 / 2.7

1.1

2.5 / 2.2

0.9

M1210S

1

0.75

1

10.4 / 9.0

2.2

4.6 / 4.0

1.6

M1210

1

0.75

3

5.5 / 4.8

2.0

4.6 / 4.0

1.6

M1215S

1.5

1.1

1

13.3 / 11.6

2.8

6.0 / 5.2

2.1

M1215

1.5

1.1

3

7.1 / 6.2

2.6

6.0 / 5.2

2.1

M1220S

2

1.5

1

17.1 / 14.9

3.6

7.8 / 6.8

2.7

M1220

2

1.5

3

9.3 / 8.1

3.4

7.8 / 6.8

2.7

M1230S

3

2.2

1

24 / 21

5.0

11.0 / 9.6

3.8

M1230

3

2.2

3

13.0 / 11.3

4.7

11.0 / 9.6

3.8

M1250

5

3.7

3

20 / 17.7

7.4

17.5 / 15.2

6.1

M1275

7.5

5.5

3

30 / 26

10.6

25 / 22

8.8

M12100

10

7.5

3

37 / 32

13.2

32 / 28

11.2

M12150

15

11

3

55 / 48

19.8

48 / 42

16.7

M12200

20

15

3

70 / 61

25.3

62 / 54

21.5

M12250

25

18.5

3

89 / 77

32.0

78 / 68

27.1

M12300

30

22

3

104 / 90

37.6

92 / 80

31.9

NOTE 1:

See Section 3.0 for model number breakdown.

NOTE 2:

See Section 8.0 for recommended fuse type.

9

Page 12

M1400 SERIES RATINGS MODEL MODEL

FOR MOTORS

NUMBER

RATED

INPUT

OUTPUT

(400 / 480 Vac, 50 - 60 Hz)

(0 - 400 / 460 Vac)

NOMINAL

NOMINAL

INPUT

CURRENT

POWER

CURRENT

POWER

(NOTE 1)

HP kW

PHASE

(AMPS)

(KVA)

(AMPS)

(KVA)

M1410

1

0.75

3

2.8 / 2.4

2.0

2.3 / 2.0

1.6

M1420

2

1.5

3

4.7 / 4.1

3.4

3.9 / 3.4

2.7

M1430

3

2.2

3

6.6 / 5.7

4.7

5.5 / 4.8

3.8

M1450

5

3.7

3

10.2 / 8.9

7.3

8.7 / 7.6

6.1

M1475

7.5

5.5

3

14.7 / 12.8

10.6

12.6 / 11.0

8.8

M14100

10

7.5

3

18.3 / 15.9

13.2

16.0 / 14.0

11.2

M14150

15

11

3

28 / 24

19.8

24 / 21

16.7

M14200

20

15

3

36 / 31

25.3

31 / 27

21.5

M14250

25

18.5

3

44 / 38

31.9

39 / 34

27.1

M14300

30

22

3

52 / 45

37.6

46 / 40

31.9

M14400

40

30

3

68 / 59

49.0

60 / 52

41.4

M14500

50

37

3

85 / 74

61.5

75 / 65

51.8

M14600

60

45

3

100 / 87

72.3

88 / 77

61.3

NOTE 1:

See Section 3.0 for model number breakdown.

NOTE 2:

See Section 8.0 for recommended fuse type.

10

Page 13

M1500 SERIES RATINGS MODEL MODEL

FOR MOTORS

NUMBER

RATED

INPUT

OUTPUT

(480 / 590 Vac, 50 - 60 Hz)

(0 - 460 / 575 Vac)

NOMINAL

NOMINAL

INPUT

CURRENT

POWER

CURRENT

POWER

(NOTE 1)

HP kW

PHASE

(AMPS)

(KVA)

(AMPS)

(KVA)

M1510

1

0.75

3

1.9 / 1.9

1.9

1.6 / 1.6

1.6

M1520

2

1.5

3

3.3 / 3.3

3.4

2.7 / 2.7

2.7

M1530

3

2.2

3

4.6 / 4.6

4.7

3.9 / 3.9

3.9

M1551

5

3.7

3

7.1 / 7.1

7.3

6.1 / 6.1

6.1

M1575

7.5

5.5

3

10.5 / 10.5

10.7

9.0 / 9.0

8.8

M15100

10

7.5

3

12.5 / 12.5

12.8

11.0 / 11.0

11.0

M15150

15

11

3

19.3 / 19.3

19.7

17.0 / 17.0

16.9

M15200

20

15

3

25 / 25

25.4

22 / 22

21.5

M15250

25

18.5

3

31 / 31

31.2

27 / 27

26.9

M15300

30

22

3

36 / 36

37.1

32 / 32

31.9

M15400

40

30

3

47 / 47

47.5

41 / 41

40.8

M15500

50

37

3

59 / 59

60.3

52 / 52

51.8

M15600

60

45

3

71 / 71

72.5

62 / 62

61.7

NOTE 1:

See Section 3.0 for model number breakdown.

NOTE 2:

See Section 8.0 for recommended fuse type.

11

Page 14

6.0

THEORY

6.1

DESCRIPTION OF AC MOTOR OPERATION Three phase AC motors are comprised of two major components, the stator and the rotor. The stator is a set of three electrical windings held stationary in the motor housing. The rotor is a metal cylinder, fixed to the motor drive shaft, which rotates within the stator. The arrangement of the stator coils and the presence of three phase AC voltage give rise to a rotating magnetic field which drives the rotor. The speed at which the magnetic field rotates is known as the synchronous speed of the motor. Synchronous speed is a function of the frequency at which the voltage is alternating and the number of poles in the stator windings. The following equation gives the relation between synchronous speed, frequency, and the number of poles: Ss = 120 f/p Where: Ss = Synchronous speed (rpm ), f = frequency (Hz), p = number of poles In three phase induction motors the actual shaft speed differs from the synchronous speed as load is applied. This difference is known as “slip”. Slip is commonly expressed as a percentage of synchronous speed. A typical value is three percent at full load. The strength of the magnetic field in the gap between the rotor and stator is proportional to the amplitude of the voltage at a given frequency. The output torque capability of the motor is, therefore, a function of the applied voltage amplitude at a given frequency. When operated below base (rated) speed, AC motors run in the range of “constant torque”. Constant torque output is obtained by maintaining a constant ratio between voltage amplitude (Volts) and frequency (Hertz). For 60 Hz motors rated at 230, 460, and 575 Vac, common values for this V/Hz ratio are 3.83, 7.66, and 9.58 respectively. Operating with these V/Hz ratios generally yields optimum torque capability. Operating at lower ratio values results in lower torque and power capability. Operating at higher ratio values will cause the motor to overheat. Most standard motors are capable of providing full torque output from 3 to 60 Hz. However, at lower speeds, where motor cooling fans become less effective, supplemental cooling may be needed to operate at full torque output continuously.

12

Page 15

If the frequency applied to the motor is increased while the voltage remains constant, torque capability will decrease as speed increases. This will cause the horsepower capability of the motor to remain approximately constant. Motors run in this mode when operated above base speed, where drive output voltage is limited by the input line voltage. This operating range is known as the “constant horsepower” range. The typical maximum range for constant horsepower is about 2.3 to 1 (60 to 140 Hz). The diagram below depicts the characteristics of a typical AC induction motor with a 60 Hz base speed.

WARNING! Consult motor manufacturer before operating motor and/or driven equipment above base speed.

150

CONSTANT TORQUE

CONSTANT HP

130

TORQUE (%)

110

TORQUE

HORSEPOWER

90 70 50 30

TOR QUE

ER W O EP RS O H

10 20

40

60

80

100

120

FREQUENCY (Hz)

6.1.1

VARIABLE TORQUE VS. CONSTANT TORQUE Variable frequency drives, and the loads they are applied to, can generally be divided into two groups: constant torque and variable torque. Constant torque loads include: vibrating conveyors, punch presses, rock crushers, machine tools, and just about every other application that is not considered variable torque. Variable torque loads include centrifugal pumps and fans, which make up the majority of HVAC applications. Variable torque loads are governed by the affinity laws, which define the relationships between speed, flow, torque and horsepower. The diagram below illustrates these relationships:

13

Page 16

100% 75% 50%

%F

LO

W

OR %T

25%

QU

E

%H

0% 0%

25%

50%

OR

P SE

OW

ER

75%

100%

% SPEED

“Variable torque” refers to the fact that the torque required varies with the square of the speed. Also, the horsepower required varies with the cube of the speed, resulting in a large reduction in horsepower for even a small reduction in speed. It is easily seen that substantial energy savings can be achieved by reducing the speed of a fan or pump. For example, reducing the speed to 50% results in a 50 HP motor having to produce only 12.5% of rated horsepower, or 6.25 HP. Variable torque drives usually have a low overload capacity (110% - 120% for 60 seconds), because variable torque applications rarely experience overload conditions. To optimize efficiency and energy savings, variable torque drives are usually programmed to follow a variable V/Hz ratio. The term “constant torque” is not entirely accurate in terms of the actual torque required for an application. Many constant torque applications have reciprocating loads, such as vibrating conveyors and punch presses, where the rotational motion of the motor is being converted to a linear motion. In such cases, the torque required can vary greatly at different points in the cycle. For constant torque loads, this fluctuation in torque is not a direct function of speed, as it is with a variable torque load. As a result, constant torque drives typically have a high overload rating (150% for 60 seconds) in order to handle the higher peak torque demands. To achieve maximum torque, constant torque drives follow a constant V/Hz ratio. Both MC Series product lines (MC1000 and MC3000) have full overload capacity (150% for 60 seconds, 180% for 30 seconds), so that either one can be used for either type of application. The V/Hz ratio can also be changed to optimize performance for either type of application.

6.2

DRIVE FUNCTION DESCRIPTION The MC Series is a 16 bit microprocessor based, keypad programmable, variable speed AC motor drive. There are four major sections: an input diode bridge and filter, a power board, a control board, and an output intelligent power module.

14

Page 17

6.2.1

DRIVE OPERATION Incoming AC line voltage is converted to a pulsating DC voltage by the input diode bridge. The DC voltage is supplied to the bus filter capacitors through a charge circuit which limits inrush current to the capacitors during power-up. The pulsating DC voltage is filtered by the bus capacitors which reduces the ripple level. The filtered DC voltage enters the inverter section of the drive, composed of six output intelligent insulated gate bi-polar transistors (IGBTs) which make up the three output legs of the drive. Each leg has one intelligent IGBT connected to the positive bus voltage and one connected to the negative bus voltage. Alternately switching on each leg, the intelligent IGBT produces an alternating voltage on each of the corresponding motor windings. By switching each output intelligent IGBT at a very high frequency (known as the carrier frequency) for varying time intervals, the inverter is able to produce a smooth, three phase, sinusoidal output current wave which optimizes motor performance.

6.2.2

CIRCUIT DESCRIPTION The control section consists of a control board with a 16 bit microprocessor, keypad and display. Drive programming is accomplished via the keypad or the serial communications port. During operation the drive can be controlled via the keypad, by control devices wired to the control terminal strip, or by the serial communications port. The Power Board contains the control and protection circuits which govern the six output IGBTs. The Power Board also contains a charging circuit for the bus filter capacitors, a motor current feedback circuit, a voltage feedback circuit, and a fault signal circuit. The drive has several built in protection circuits. These include phase-to-phase and phase-to-ground short circuit protection, high and low line voltage protection, protection against excessive ambient temperature, and protection against continuous excessive output current. Activation of any of these circuits will cause the drive to shut down in a fault condition.

6.2.3

MC1000 INPUTS AND OUTPUTS The drive has two analog inputs (0-10 VDC and 4-20 mA) that can be used for speed reference, PID setpoint reference, or PID feedback. A speed potentiometer (10,000 Ohm) can be used with the 0-10 VDC input. There are also two analog outputs: one is proportional to speed (frequency), and the other is proportional to load. The drive has three programmable outputs for status indication: one Form C relay and two open-collector outputs. Refer to Sections 14.0 - CONTROL WIRING and 15.0 - CONTROL WIRING DIAGRAMS for more information.

15

Page 18

7.0

INSTALLATION WARNING! DRIVES MUST NOT BE INSTALLED WHERE SUBJECTED TO ADVERSE ENVIRONMENTAL CONDITIONS! DRIVES MUST NOT BE INSTALLED WHERE SUBJECTED TO: COMBUSTIBLE, OILY, OR HAZARDOUS VAPORS OR DUST; EXCESSIVE MOISTURE OR DIRT; STRONG VIBRATION; EXCESSIVE AMBIENT TEMPERATURES. CONSULT AC TECHNOLOGY FOR MORE INFORMATION ON THE SUITABILITY OF A DRIVE TO A PARTICULAR ENVIRONMENT. The drive should be mounted on a smooth vertical surface capable of safely supporting the unit without vibrating. The LCD display has an optimum field of view, this should be considered when determining the mounting position. Chassis models must be installed in an electrical enclosure which will provide complete mechanical protection and maintain uniform internal temperature within the drive’s ambient operating temperature rating. All drive models MUST be mounted in a vertical position for proper heatsink cooling. Maintain a minimum spacing around the drive as follows:

SPACING REQUIREMENTS SPACING

HP

INCHES mm

0.25 - 5

2

50

7.5 - 25

4

100

30 - 60

6

150

All drive models MUST be mounted in a vertical position for proper heatsink cooling. Fans or blowers should be used to insure proper cooling in tight quarters. Do not mount drives above other drives or heat producing equipment that would impede the cooling of the drive. Note the ambient operating temperature ratings for each drive model. If it is necessary to drill or cut the drive enclosure or panel, extreme care must be taken to avoid damaging drive components or contaminating the drive with metal fragments (which cause shorting of electrical circuits). Cover drive components with a clean cloth to keep out metal chips and other debris. Use a vacuum cleaner to clean drive components after drilling, even if chips do not appear to be present. Do not attempt to use positive air pressure to blow chips out of drive, as this tends to lodge debris under electronic components. Contaminating the drive with metal chips can cause drive failure and will void the warranty.

16

Page 19

The MC1000 Series is UL approved for solid state motor overload protection. Therefore, a separate thermal overload relay is not required for single motor applications. In applications where one drive is operating more than one motor, a separate thermal overload relay is required for each motor per NEC.

7.1

INSTALLATION AFTER A LONG PERIOD OF STORAGE

WARNING! Severe damage to the drive can result if it is operated after a long period of storage or inactivity without reforming the DC bus capacitors!

If input power has not been applied to the drive for a period of time exceeding three years (due to storage, etc), the electrolytic DC bus capacitors within the drive can change internally, resulting in excessive leakage current. This can result in premature failure of the capacitors if the drive is operated after such a long period of inactivity or storage. In order to reform the capacitors and prepare the drive for operation after a long period of inactivity, apply input power to the drive for 8 hours prior to actually operating the drive/motor system.

7.2

EXPLOSION PROOF APPLICATIONS Explosion proof motors that are not rated for inverter use lose their certification when used for variable speed. Due to the many areas of liability that may be encountered when dealing with these applications, the following statement of policy applies: “AC Technology Corporation inverter products are sold with no warranty of fitness for a particular purpose or warranty of suitability for use with explosion proof motors. AC Technology Corporation accepts no responsibility for any direct, incidental or consequential loss, cost, or damage that may arise through the use of its AC inverter products in these applications. The purchaser expressly agrees to assume all risk of any loss, cost, or damage that may arise from such application."

17

Page 20

8.0

INPUT AC REQUIREMENTS WARNING! Hazard of electrical shock! Disconnect incoming power and wait three minutes before servicing the drive. Capacitors retain charge after power is removed.

8.1

INPUT AC POWER REQUIREMENTS

8.1.1

VOLTAGE The input voltage must match the drive’s nameplate voltage rating. Voltage fluctuation must not vary by greater than 10% overvoltage or 15% undervoltage. NOTE: Drives with dual rated input voltage must be programmed for the proper supply voltage. Refer to Parameter 0 - LINE VOLTS in Section 18.0 DESCRIPTION OF PARAMETERS. The drive is suitable for use on a circuit capable of delivering not more than 200,000 RMS symmetrical amperes, at the drive’s rated voltage. Three phase voltage imbalance must be less than 2.0% phase to phase. Excessive phase to phase imbalance can cause severe damage to the drive’s power components. Motor voltage should match line voltage in normal applications. The drive’s maximum output voltage will equal the input voltage. Use extreme caution when using a motor with a voltage rating which is different from the input line voltage.

8.1.2

SUPPLY TRANSFORMER kVA RATINGS If the kVA rating of the AC supply transformer is greater than ten times the input kVA rating of the drive, a drive isolation transformer, or a 2 - 3% input line reactor (also known as a choke) must be added.

8.2

INPUT FUSING AND DISCONNECT REQUIREMENTS A circuit breaker or a disconnect switch with fuses must be provided in accordance with the National Electric Code (NEC) and all local codes. The MC1000 drive is capable of withstanding up to 150% current overload for 60 seconds. Select a fuse or magnetic trip circuit breaker rated at 1.5 times the input current rating of the drive (the minimum size should be 10 amps, regardless of input current rating). Refer to Section 5.0 - MC1000 RATINGS.