The text of a manual · part 1 of 5
AC Tech Variable Speed AC Motor Drives SCN Series Installation and Operation Manual, pages 1 to 10
Pages 1 to 10 of 47
The original document is the PDF (269 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AC Tech SN103S and Lenze SN103S
Page 1
AC Tech Variable Speed AC Motor Drives
SCN Series Installation and Operation Manual
Page 2
Manual Number: IMSN02
TABLE OF CONTENTS 1.0
GENERAL..................................................................................... 1
2.0
SCN DIMENSIONS....................................................................... 2
3.0
SCN MODEL DESIGNATION CODE........................................ 3
4.0
SCN SPECIFICATIONS............................................................... 3
5.0
SCN RATINGS.............................................................................. 4
6.0
INSTALLATION........................................................................... 5
7.0
INPUT AC POWER REQUIREMENTS..................................... 7
8.0
POWER WIRING......................................................................... 8
9.0
SCN POWER WIRING DIAGRAM............................................ 9
10.0
CONTROL WIRING.................................................................... 10
11.0
SCN CONTROL WIRING DIAGRAMS..................................... 13
12.0
INITIAL POWER UP AND MOTOR ROTATION................... 16
13.0
PROGRAMMING THE SCN DRIVE......................................... 18
14.0
PARAMETER MENU.................................................................. 21
15.0
DESCRIPTION OF PARAMETERS.......................................... 23
16.0
TROUBLESHOOTING................................................................ 37
17.0
SCN DISPLAY MESSAGES........................................................ 39
18.0
USER SETTING RECORD.......................................................... 41
Page 3
THE SCN SUB-MICRO DRIVE
INPUT POWER TERMINALS GROUND LUG ELECTRONIC PROGRAMMING MODULE (EPM)
2-DIGIT LED DISPLAY
PROGRAMMING BUTTONS
CONTROL TERMINAL STRIP
OUTPUT (MOTOR) TERMINALS
Page 4
1.0
GENERAL
1.1
PRODUCTS COVERED IN THIS MANUAL
This manual covers the AC Tech SCN Series Variable Frequency Drive. 1.2
PRODUCT CHANGES
AC Technology Corporation reserves the right to discontinue or make modifications to the design of its products without prior notice, and holds no obligation to make modifications to products sold previously. AC Technology Corporation also holds no liability for losses of any kind which may result from this action. 1.3
WARRANTY
AC Technology Corporation warrants the SCN Series AC motor control to be free of defects in material and workmanship for a period of twelve months from the date of sale to the user, or eighteen months from the date of shipment, which ever occurs first. If an SCN motor control, under normal use, becomes defective within the stated warranty time period, contact AC Technology's Service Department for instructions on obtaining a warranty replacement unit. AC Technology Corporation reserves the right to make the final determination as to the validity of a warranty claim, and sole obligation is to repair or replace only components which have been rendered defective due to faulty material or workmanship. No warranty claim will be accepted for components which have been damaged due to mishandling, improper installation, unauthorized repair and/or alteration of the product, operation in excess of design specifications or other misuse, or improper maintenance. AC Technology Corporation makes no warranty that its products are compatible with any other equipment, or to any specific application, to which they may be applied and shall not be held liable for any other consequential damage or injury arising from the use of its products. This warranty is in lieu of all other warranties, expressed or implied. No other person, firm or corporation is authorized to assume, for AC Technology Corporation, any other liability in connection with the demonstration or sale of its products. 1.4
RECEIVING
Inspect all cartons for damage which may have occurred during shipping. Carefully unpack equipment and inspect thoroughly for damage or shortage. Report any damage to carrier and/or shortages to supplier. All major components and connections should be examined for damage and tightness, with special attention given to PC boards, plugs, knobs and switches. 1.5
CUSTOMER MODIFICATION
AC Technology Corporation, its sales representatives and distributors, welcome the opportunity to assist our customers in applying our products. Many customizing options are available to aid in this function. AC Technology Corporation cannot assume responsibility for any modifications not authorized by its engineering department.
1
Page 5
2.0
SCN DIMENSIONS 0.38"
R
H
W 0.38" 0.18" 0.69"
D P
0.19" Dia. Slot Mounting Tab Detail
HP 0.25
INPUT VOLTAGE 120 / 208 / 240
MODEL SN103S
H 5.75
W 2.88
D 3.76
P 0.80
R 4.37
208 / 240
SN203S
5.75
2.88
3.76
0.80
4.37
0.5
120 / 208 / 240
SN105S
5.75
2.88
3.76
0.80
4.37
208 / 240
SN205S
5.75
2.88
3.76
0.80
4.37
1
1.5
2 3
208 / 240
SN205
5.75
2.88
3.76
0.80
4.37
120 / 208 / 240
SN110S
5.75
3.76
5.24
1.90
4.37
208 / 240
SN210S
5.75
2.88
4.56
1.60
4.37
208 / 240
SN210
5.75
2.88
4.56
1.60
4.37
120 / 208 / 240
SN115S
5.75
3.76
5.24
1.90
4.37
208 / 240
SN215S
5.75
3.76
5.24
1.90
4.37
208 / 240
SN215
5.75
2.88
5.56
2.60
4.37
208 / 240
SN220S
5.75
3.76
5.24
1.90
4.37
208 / 240
SN220
5.75
2.88
5.56
2.60
4.37
208 / 240
SN230S
5.75
3.76
6.74
3.40
4.37
208 / 240
SN230
5.75
3.76
6.74
2.60
4.37
2
Page 6
3.0
SCN MODEL DESIGNATION CODE
The SCN model number gives a full description of the basic drive unit (see example below). EXAMPLE: SN210
(SCN Series, 208/240 Vac, 1 HP, 3 phase input)
SN
2
10
Series: SN = SCN Series Variable Speed AC Motor Drive Input Voltage: 1 = 120/208/240 Vac (For 110 to 120 Vac and 208 to 240 Vac; 50 or 60 Hz) 2 = 208/240 Vac (For 208, 220, 230, and 240 Vac; 50 or 60 Hz) Horsepower: 03 = ¼ Hp 05 = ½ Hp 10 = 1 Hp Input: Phase S
4.0
15 20 30
= Single phase input only. No character indicates three phase input only.
SCN SPECIFICATIONS
Storage Temperature Ambient Operating Temperature Ambient Humidity Altitude Input Line Voltages Input Voltage Tolerance Input Frequency Tolerance Output Wave Form Output Frequency Carrier Frequency Service Factor Efficiency Power Factor (displacement) Overload Current Capacity Speed Reference Follower Power Supply for Auxiliary Relay Digital Output 1
= 1½ Hp = 2 Hp = 3 Hp
-20 to 70 C 0 to 50 C (up to 6 kHz carrier, derate above 6 kHz) < 95% (non-condensing) 3300 ft (1000 m) above sea level (without derating) 120/208/240 Vac single phase, 208/240 Vac three phase +10%, -15% 48 to 62 Hz Sine Coded PWM 0 - 99 Hz 4 kHz to 10 kHz 1.00 (up to 6 kHz carrier, derate above 6 kHz) Up to 98% 0.96 or better 150% for 60 seconds, 180% for 30 seconds Speed Potentiometer, 0-10 VDC (must be isolated)1 50 mA at 12 VDC Circuit rated 50 mA and 30 VDC max (to drive auxiliary relay)1
WARNING: Control terminals are not isolated from line voltage! Do not touch! 3
Page 7
5.0
SCN RATINGS
MODEL
FOR MOTORS
OUTPUT
HEAT LOSS
NUMBER
RATED
INPUT
CURRENT
POWER
CURRENT
(WATTS)
(NOTE 1)
HP
PHASE
(AMPS)
(kVA)
(AMPS)
(NOTE 4)
kW
INPUT (50-60 Hz)
SN100 SERIES (NOTE 2) SN103S SN105S SN110S SN115S
0.25 0.5 1 1.5
0.2 0.37 0.75 1.1
0 - 230 / 200 / 230 Vac
120 / 208 / 240 Vac 1 1 1 1
SN200S SERIES (NOTE 3)
6.0 / 3.5 / 3.0 9.2 / 5.3 / 4.6 16.6 / 9.6 / 8.3 24 / 13.9 / 12.0
0.72 1.1 2.0 2.9
0.25
0.20
1
SN205S
0.5
0.37
SN210S
1
0.75
SN215S
1.5
SN220S SN230S
21 28 48 73
0 - 200 / 230 Vac
208 / 240 Vac
SN203S
1.4 / 1.6 / 1.4 2.2 / 2.5 / 2.2 4.2 / 4.8 / 4.2 6.0 / 6.9 / 6.0
3.6 / 3.2
0.76
1.6 / 1.4
19
1
5.4 / 4.7
1.2
2.5 / 2.2
26
1
10.6 / 9.2
2.2
4.8 / 4.2
49
1.1
1
13.9 / 12.0
2.9
6.9 / 6.0
82
2
1.5
1
14.8 / 12.9
3.2
7.8 / 6.8
86
3
2.2
1
19.7 / 17.1
4.1
11.0 / 9.6
130
SN200 SERIES (NOTE 3)
208 / 240 Vac
0 - 200 / 230 Vac
SN205
0.5
0.37
3
3.1 / 2.7
1.1
2.5 / 2.2
24
SN210
1
0.75
3
5.8 / 5.1
2.1
4.8 / 4.2
41
SN215
1.5
1.1
3
8.0 / 6.9
2.9
6.9 / 6.0
69
SN220
2
1.5
3
9.1 / 7.9
3.3
7.8 / 6.8
78
SN230
3
2.2
3
12.4 / 10.8
4.5
11.0 / 9.6
117
NOTE 1: See Section 3.0 for model number breakdown. NOTE 2: The first current ratings listed are for 120 Vac input, the second current ratings are for 208 Vac input, and the third current ratings are for 240 Vac input. 120 Vac input yields three phase 230 Vac output. NOTE 3: The higher current ratings are for 208 Vac input and the lower current ratings are for 240 Vac input. NOTE 4: Values are worst-case (not typical) for 6kHz carrier frequency at full speed and full load.
4
Page 8
6.0
INSTALLATION
NOTE! SCN drives are intended for inclusion within other equipment, by professional electrical installers. They are not intended for stand-alone operation. WARNING! DRIVES MUST NOT BE INSTALLED WHERE SUBJECTED TO ADVERSE ENVIRONMENTAL CONDITIONS SUCH AS: COMBUSTIBLE, OILY, OR HAZARDOUS VAPORS OR DUST; EXCESSIVE MOISTURE OR DIRT; VIBRATION; EXCESSIVE AMBIENT TEMPERATURES. CONSULT AC TECHNOLOGY FOR MORE INFORMATION ON THE SUITABILITY OF A DRIVE TO A PARTICULAR ENVIRONMENT.
WARNING! Hazard of electrical shock! The SCN control terminals are not isolated from line voltage! Line voltage is present between the control terminals and ground. Do not touch! Disconnect input power and wait three minutes before making connections to the control terminals. Devices (such as switches, pushbuttons, potentiometers, relays, etc) and wiring connected to the control terminals are hot to ground and must have an insulation rating of at least 240 Vac or a dielectric rating of at least 1500 volts to prevent damage to equipment and/or injury to personnel. SCN models are suitable for UL pollution degree 2 environment only, and MUST be installed in an electrical enclosure which will provide complete mechanical protection and will maintain the internal temperature within the drive’s ambient operating temperature rating. All drive models MUST be mounted in a vertical position for proper heatsink cooling. Maintain a minimum spacing around the drive of at least one inch on each side and two inches on the top and bottom. Allow more spacing if the drive is mounted next to other heat-producing equipment. Do not mount drives above other drives or heat producing equipment. Fans or blowers should be used to insure proper cooling in tight quarters. In order to properly size an enclosure, the heat generated by the drive(s) must be known. Refer to the HEAT LOSS column in Section 5.0 - SCN RATINGS. An enclosure manufacturer can then determine the required enclosure size based on the total heat generated inside the enclosure (from the drive(s) and other heat sources), the maximum allowable temperature inside the enclosure, the maximum ambient temperature outside the enclosure, and the enclosure properties. The SCN Series is UL approved for solid state motor overload protection. Therefore, a separate thermal overload relay is not required for single motor applications.
5
Page 9
6.1
INSTALLATION AFTER A LONG PERIOD OF STORAGE
WARNING! Severe damage to the drive can result if it is operated after a long period of storage or inactivity without reforming the DC bus capacitors! If input power has not been applied to the drive for a period of time exceeding three years (due to storage, etc), the electrolytic DC bus capacitors within the drive can change internally, resulting in excessive leakage current. This can result in premature failure of the capacitors if the drive is operated after such a long period of inactivity or storage. In order to reform the capacitors and prepare the drive for operation after a long period of inactivity, apply input power to the drive for 8 hours prior to actually operating the motor. 6.2
EXPLOSION PROOF APPLICATIONS
Explosion proof motors that are not rated for inverter use lose their certification when used for variable speed. Due to the many areas of liability that may be encountered when dealing with these applications, the following statement of policy applies: “AC Technology Corporation inverter products are sold with no warranty of fitness for a particular purpose or warranty of suitability for use with explosion proof motors. AC Technology Corporation accepts no responsibility for any direct, incidental or consequential loss, cost, or damage that may arise through the use of its AC inverter products in these applications. The purchaser expressly agrees to assume all risk of any loss, cost, or damage that may arise from such application. AC Technology Corporation or AC Technology Corporation’s engineering department will not knowingly approve applications involving explosion proof motors.”
6
Page 10
7.0
INPUT AC POWER REQUIREMENTS
WARNING! Hazard of electrical shock! Capacitors retain charge after power is removed. Disconnect incoming power and wait until the voltage between terminals B+ and B- is 0 VDC before servicing the drive. The input voltage must match the nameplate voltage rating of the drive. Voltage fluctuation must not vary by greater than 10% overvoltage or 15% undervoltage. NOTE: Drives with dual input voltage ratings must be programmed for the proper supply voltage (refer to Parameter 01 - LINE VOLTAGE SELECTION in Section 15.0 - DESCRIPTION OF PARAMETERS). The drive is suitable for use on a circuit capable of delivering not more than 5,000 RMS symmetrical amperes at the drive’s rated voltage. Three phase voltage imbalance must be less than 2.0% phase to phase. Excessive phase to phase imbalance can cause severe damage to the drive. Motor voltage should match line voltage in normal applications. The drive’s maximum output voltage will equal the input voltage. Use extreme caution when using a motor with a voltage rating which is different from the input line voltage. 7.1
INPUT VOLTAGE RATINGS
SN100 Series drives are rated for 120/208/240 Vac, single phase, 50-60 Hz input. The drive will function with input voltage of 120 Vac (+10%, -15%), at 48 to 60 Hz, or with input voltage of 208 to 240 Vac (+ 10%, - 15%), at 48 to 62 Hz. SN200S Series drives are rated for 208/240 Vac, single phase, 50-60 Hz input. The drive will function with input voltages of 208 to 240 Vac (+10%, -15%), at 48 to 62 Hz. SN200 Series drives are rated for 208/240 Vac, three phase, 50-60 Hz input. The drive will function with input voltages of 208 to 240 Vac (+ 10%, - 15%), at 48 to 62 Hz. NOTE: Parameter 01 - LINE VOLTAGE SELECTION must be programmed according to the applied input voltage. See Section 15.0 - DESCRIPTION OF PARAMETERS. 7.2
INPUT FUSING AND DISCONNECT REQUIREMENTS
A circuit breaker or a disconnect switch with fuses must be provided in accordance with the National Electric Code (NEC) and all local codes. The SCN drive is capable of withstanding up to 150% current overload for 60 seconds. Select a fuse or magnetic trip circuit breaker rated at 1.5 times the input current rating of the drive (the minimum fuse size should be 10 amps, regardless of input current rating). Refer to Section 5.0 - SCN RATINGS.
7