Page 1 of AC Tech Variable Speed AC Motor Drives SCN Series Installation and Operation Manual

Manual · AC Tech

AC Tech Variable Speed AC Motor Drives SCN Series Installation and Operation Manual

Manual47 pagesPDF 269 KB

Installation and operation manual for the AC Tech SCN Series variable speed AC motor drives, including the SN103S (0.25 HP, 120/208/240 Vac).

Download the PDF269 KB

Covers · 2 models

The models it covers

Summary

What is in it

AC Technology Corporation installation and operation manual for the SCN Series sub-micro variable frequency drives (SN100, SN200S and SN200 models, including the SN103S). It gives dimensions, the model designation code, specifications and ratings, installation and enclosure guidance, input power and fusing requirements, power and control wiring diagrams, initial power-up, programming with the keypad, a full parameter menu and descriptions, troubleshooting and display messages.

Its parts

  1. General
  2. SCN Dimensions
  3. SCN Model Designation Code
  4. SCN Specifications
  5. SCN Ratings
  6. Installation
  7. Input AC Power Requirements
  8. Power Wiring
  9. SCN Power Wiring Diagram
  10. Control Wiring
  11. SCN Control Wiring Diagrams
  12. Initial Power Up and Motor Rotation
  13. Programming the SCN Drive
  14. Parameter Menu
  15. Description of Parameters

From the manual

Key facts from this manual

Each line names its page in the PDF.

An installation and operation manual (IMSN02) for the AC Tech SCN Series sub-micro variable speed AC motor drives, models SN103S to SN230 (1/4 to 3 Hp). It gives the specifications, dimensions, power and control wiring, the parameter menu, fault messages and troubleshooting. It helps a technician install, program and diagnose a drive such as the SN103S.

Read for this summary: pages 1 to 14, 24 and 40 to 44 of 47.

What it is
AC Tech SCN Series sub-micro variable frequency drive with 2-digit LED display and keypad p. 3, 4
SN103S rating
SN103S: 0.25 HP, 120/208/240 Vac, single phase input only p. 5, 6
Overload capacity
150% for 60 seconds, 180% for 30 seconds p. 6
Input tolerance
+10%, -15%; 48 to 62 Hz p. 6
Speed reference
5k to 10k ohm speed pot, or isolated 0-10 VDC signal on TB-5 and TB-3 p. 13
SN103S dimensions
SN103S: H 5.75, W 2.88, D 3.76 (inches) p. 5
Input fusing
1.5 times input current rating, 10 amps minimum; Bussman KTK-R Class CC fuses recommended p. 10, 11
Power terminals
Strip 0.20 to 0.25 inches; tighten to 4.0 to 4.5 lb-in p. 11
Fault codes
AF high temperature, HF high DC bus voltage, LF low DC bus voltage, OF output transistor, SF single-phase, F1 EPM p. 41

What this manual walks you through

  • Mounting the drive in an enclosure with proper spacing p. 8
  • Preparing a drive after a long period of storage p. 9
  • Input power, fusing and disconnect requirements p. 10, 11
  • Wiring single phase or three phase input and the motor p. 11, 12
  • Control wiring, speed pot, preset speeds, jog and MOP control p. 13, 14
  • Parameter menu with ranges and factory defaults p. 24, 44
  • Viewing fault history and motor load for troubleshooting p. 40
  • Reading fault messages and clearing a fault p. 41
  • Speed source, status and warning display messages p. 42, 43

Good to know

  • The control terminals are not isolated from line voltage. p. 6
  • A drive unpowered for over three years needs input power for 8 hours before running the motor. p. 9
  • Incoming AC power must never be connected to output terminals T1, T2 or T3. p. 12
  • Cycling the input disconnect more than once every two minutes may damage the drive. p. 11
  • In JOG mode the STOP signal and auxiliary stop will not stop the drive. p. 14

Questions this manual answers

What does an LF fault mean on an AC Tech SCN drive?

LF is the low DC bus voltage fault: the line voltage is too low. It clears only after the input voltage returns to normal. p. 41

How do I clear a fault on an SCN drive?

Issue a STOP command on the terminal strip. The fault clears only if the condition that caused it has passed. p. 41

How is 120 Vac input wired on an SN100S model?

Wire 120 Vac to terminals L1 and N. For 208/240 Vac, wire to L1 and L2 and leave N unused. p. 11

What speed pot works with the SCN drive?

A 5k to 10k ohm pot, with the wiper on TB-5, the high end on TB-6 and the low end on TB-3. p. 13

What fuse does the SCN drive need?

A fuse or magnetic trip breaker rated 1.5 times the drive input current, at least 10 amps, rated 250 Vac minimum. p. 10, 11

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 4741-47

The file

Revision and size

RevisionIMSN02
PublisherAC Technology Corporation
Pages47
PDF269 KB
TextText from the PDF itself.

The first pages · 3 of 47

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 47
Page 2
Page 2of 47
Page 3
Page 3of 47