Page 37
IMPORTANT: Note correct orientation of each check valve. 5.
!
CAUTION
Install the new spring in the Injection Check Valve.
Depressurize and drain pipeline (or isolate I.C.V. point using valves) so that I.C.V. can safely be disassembled.
10.0 Checking Pump for Proper Zero Position (Stroke Knob)
10.1
`
1.
With pump running, turn stroke knob counter-clockwise toward zero or end of black or red band on dial.
2.
LISTEN to the clicking as the pump is running. The pump should operate quietly at the zero position (no clicking).
3.
If the pump continues to click at zero or stops clicking before zero is reached, the pump zero must be reset (see Section 10.1 or 10.2).
Type I ‑ Push on Knob Re-Zeroing and Stroke Knob Disassembly and Assembly 1.
Remove stroke knob from the pump by grasping the knob firmly and pulling it toward you.
2.
Pry off the yellow cap.
3.
Place the knob on a flat surface.
4.
Using needle-nose pliers, squeeze the inner section together while lifting the outer section up.
5.
Push the inner section back onto the “D” shaped stroke shaft.
6.
With the pump running, zero the pump by turning the inner section of the knob counter-clockwise until the pump stops clicking.
37
Page 38
7.
Position the outer section of the knob so that the pointer aligns with zero on the nameplate or end of the black or red band.
8.
Push down on the outer section (a snap sound indicates parts are locked together).
9.
Replace the yellow cap over the outer section of the knob, aligning the tabs on the cap with the slots inside the knob.
Stroke Knob Assembly (Type I)
38
Page 39
39
Page 40
11.0 Troubleshooting PROBLEM
POSSIBLE CAUSE
Pump Will Not Prime
1.
Pump not turned on or plugged in.
2.
Output dials not set properly.
3.
Foot Valve not in vertical position on bottom of tank.
4.
Pump suction lift too high.
5.
Suction tubing is curved or coiled in tank.
6.
Fittings are over tightened.
7.
Air trap in suction valve tubing.
8.
Too much pressure at discharge. (Pumps without multi-function valve.)
1.
Solution container ran dry.
2.
Foot Valve is not in a vertical position on the bottom of the tank.
3.
Pump suction lift is too high.
4.
Suction tubing is curved or coiled in tank.
5.
Fittings are over tightened.
6.
Air trap in suction valve tubing.
7.
Air leak on suction side.
Pump Loses Prime
40
Page 41
SOLUTION 1.
Turn on pump/plug in pump.
2.
Always prime pump with speed at 80% and stroke at 100%.
3.
Foot Valve must be vertical (see Foot Valve Installation, Section 4.6).
4.
Maximum suction lift is 5 ft (1.5 m). Pumps with High Viscosity Liquid Handling Assemblies require flooded suction.
5.
Suction tubing must be vertical. Use LMI tubing straightener supplied with pump (see Section 4.6).
6.
Do not overtighten fittings. This causes seal rings to distort and not seat properly which causes pump to leak back or lose prime.
7.
Suction tubing should be as vertical as possible. AVOID FALSE FLOODED SUCTION! (see Section 4.2.1).
8.
Shut off valves in pressurized line. Disconnect tubing at injection check valve (see Priming Section 6.0). When pump is primed, reconnect discharge tubing.
1.
Refill container with solution and reprime (see Section 6.0).
2.
Foot Valve must be vertical (see Foot Valve Installation, Section 4.6).
3.
Maximum suction lift is 5 ft (1.5 m). Pumps with High Viscosity Liquid Handling Assemblies require flooded suction.
4. Suction tubing must be vertical. Use LMI tubing straightener supplied with pump (see Section 4.6). 5.
Do not overtighten fittings. This causes seal rings to distort and not seat properly which caused pump to leak back or lose prime.
6.
Suction tubing should be as vertical as possible. AVOID FALSE FLOODED SUCTION! (see Section 4.2.1).
7.
Check for pinholes, cracks. Replace if necessary.
41
Page 42
Troubleshooting (continued)
PROBLEM
POSSIBLE CAUSE
Leakage at tubing
1.
Worn tubing ends.
2.
Loose or cracked fitting.
3.
Worn seal rings.
4.
Solution attacking Liquid Handling Assembly material.
Low Output or Failure 1. to Pump Against Pressure 2.
Failure to Run
Excessive Pump Output
42
Pump’s maximum pressure rating is exceeded by injection pressure. Worn Seal Rings.
3.
Ruptured Liquifram™.
4.
Incorrect stroke length.
5.
Tubing run on discharge may be too long.
6.
Clogged Foot Valve strainer.
1.
Pump not turned on or plugged in.
2.
EPU failure.
3.
Pulser failure.
1.
Syphoning. (Pumping downhill without a multi-function valve).
2.
Little or no pressure at injection point.
3.
Excessive strokes per minute.
Page 43
SOLUTION 1.
Cut about 1 in (25 mm) off tubing and then replace as before.
2. Replace fitting if cracked. Carefully hand tighten fittings. Do not use pipe wrench. Once fitting comes into contact with seal ring, tighten an additional 1/8 or 1/4 turn. 3. Replace balls and seal rings (see Section 8.3) Spare Parts (SP-#). 4. Consult your local distributor for alternate materials. 1.
Injection pressure cannot exceed pump’s maximum pressure. See pump data plate.
2. Worn seal rings or cartridge valves may need replacement (see Section 9.3). Spare Parts (SP- #), or RPM Pro Pac™ kit. 3. Replace Liquifram™ (see Section 9.2). 4. Check zero on pump/Re-zero pump (see Section 10.0). 5. Longer tubing runs may create frictional losses sufficient to reduce pump’s pressure rating. Consult factory for more information. 6. Remove Foot Valve strainer when pumping slurries or when solution particles cause strainer to clog. 1.
Turn on or plug in pump.
2. Disassemble pump and measure the resistance of the EPU across the EPU wires. Resistance reading should be in accordance to the EPU Resistance Chart (see Section 12.0). Also, check EPU leads to ground. Consult supplier or factory. 3. The pulser should be replaced if EPU checks out OK. Consult supplier or factory. 1.
Move injection point to a pressurized location or install an LMI 4-FV (see Section 4.4).
2. If pressure at injection point is less than 25 psi (1.7 Bar), an LMI 4-FV should be installed (see Section 4.4). 3. Replace pulser or resistor. Consult factory.
43
Page 44
12.0 EPU Resistance Chart Pump Series Voltage
PW4, PW5, PW6 P04, P05, P06 P14, P15 P16 P74, P75, P76 (see Note 1) P02, P03 P12, P13 (see Note 2) AA14, AA74, AA94 AA15, AA75, AA95 AA16, AA76, AA96 AA17, AA77, AA97 P02, P03 P12, P13 J54D, J55D, J56D E70, E71, E72, E73, E74
B11, B12, B13, B14 B71, B72, B73, B74, B91, B92, B93, B84 C10, C11, C12, C13, C14 C70, C71, C72, C73, C74 C90, C91, C92, C93, C94 C76, C77, C78
Coil Resistance (Ohms) @ 20o C (68o F)*
115 VAC 230 VAC
76 - 87 307 - 353
115 VAC 230 VAC
152 - 176 583 - 671
115 VAC 230 VAC
76- 87 291- 335
12 VDC 115 VAC 230 VAC 115 VAC 230 VAC
1.1 - 1.3 22.8 - 26.2 91 - 105 43 - 49 167 - 193
115 VAC 230 VAC
22.8 - 26.2 91 - 105
115 VAC 230 VAC
14.4 - 16.6 57.7 - 66.3
* Let pump cool down completely before checking resistance. EPU checked within 10 hours of operation can increase coil resistance reading as much as 20%. NOTES: 1. Pumps with serial numbers lower than: 960113429 2. Pumps with serial numbers higher than: 960113429 201 Ivyland Road Ivyland, PA 18974 TEL: (215) 293-0401 FAX: (215) 293-0445 http://www.lmipumps.com © 2001 Milton Roy Company - All Rights Reserved Printed in USA Specifications subject to change without notice.