7.0

Methods of Externally Triggering

Method of Triggering LMI Pump Through 4-Pin Connector

1. Switch Closure Switch closing triggers pump 2. NPN Transistor Base goes high to trigger pump

3. PNP Transistor Base goes low to trigger pump

+ White

– Black + White

– Black + White

4. Opto Isolator

– Black

Switch or transistors must be capable of switching 15V DC at 2 milliamperes. Minimum time in low impedance state (on) is 50 milliseconds. Minimum time in high impedance state (off) is 100 milliseconds. 28

Page 29 read from a scan by OCR; it may hold reading errors

or Pacing B7, C7 and P7 Pumps

120V Higher Frequency Pulses 220 - 240 V @ciccncccgeccat 50 - 60 Hz Lower Frequency Pulses a 4-20 milliamp DC MICROPACE 4-20 milliamp DC A/D CONVERTER MP-100 MICROPACE” Higher Frequency Pulses 4 DIGIT DIVIDER @rceeccccecvsens MP-400 MICROPACE” Lower Frequency Pulses 40GT MUTPLER|, < - = MP-500M 26006 Pulse

| Transmitter i [2 Programmable © } I | Divider |

Programmable Divider

RFP Flowmeter

: FC Flowmeter/Contactor aN sae

4 ee

Page 30

8.0

Calibration

Once installation is complete and the approximate output has been determined, the pump should be calibrated to adjust speed and stroke for your actual desired output. (Calibration cylinders may be purchased from your local LMI distributor, ref. publication 1798.) .

1.

Be sure the pump is primed, and discharge tubing and Injection Check Valve are installed as they would be in normal service (i.e., including factors such as injection pressure, fluid viscosity, and suction lift).

2.

Place the Foot Valve in a graduated container with a volume of 1000 ml or more.

3.

Plug in and switch pump to Internal Mode. Pump until all the air is exhausted from the suction line and head.

4.

Turn the pump off. Refill graduated container to a level starting point.

If pump is equipped with pressure control, see Section 8.1 before proceeding.

30

5.

Using a stopwatch or timer, turn the pump on for a measured amount of time (50 pump strokes minimum). The longer the time period, the more confident you can be of the results. Be sure to count the number of strokes during the calibration period when making comparisons.

6.

Turn the pump off. Note the time elapsed in relation to volume displaced in the graduate. Now, calculate the output in the time unit you choose (minutes, hours, days, etc.).

7.

If the output is too low or too great, adjust speed and or stroke, estimating required correction and repeat steps 1-7.

Page 31

8.1

Pressure Control Adjust Pressure Control: While unit is running, turn Pressure Control Potentiometer slowly counter-clockwise until unit just begins to stall. From this stall point, now turn Pressure Control Potentiometer clockwise halfway between the stall point and maximum setting. This is the optimum pressure control setting for your application. Increase setting if back pressure is increased. Adjusting pressure control decreases pressure rating of pump.

Adjust pressure control to reduce heat, shock, and pulsations; and to prolong pump life. 31

Page 32

8.2

Calibration Procedure - On-Site Volumetric Calibration in External Mode 1.

Since pump output is governed by an external device such as Flowmeter-Pulser, Liquitron™ Controller, or 4-20 mA DC signal from an instrument with an LMI Analog-toDigital Converter, only the output per stroke may be calibrated.

2.

With pump primed and discharge tubing connected to the injection point as it would be in normal service, place Foot Valve Assembly in a graduated container with a volume of 1000 ml or more.

3.

Switch pump to Internal mode with Speed Knob set at 100 until air is exhausted from suction line and pump head.

4.

Adjust Pressure Control (if desired) - See Section 8.1.

5.

Switch pump OFF and note solution level in graduated container. Refill graduate to a starting point.

6.

Switch pump ON and count the number of strokes for exactly one minute, then switch pump OFF.

7.

Note volume pumped during the calibration period of one minute. Divide into this the number of strokes to determine the volume of solution pumped per stroke. Example: 500 ml in 100 strokes = 5.0 ml per stroke.

Multiply this by your expected stroke rate per minute, per hour or per day and compare with desired output requirements. 8.

Adjust Stroke Length Knob (lower knob) to your best estimate of required correction and repeat calibration procedure.

9.0

Spare Parts Replacement Routine Maintenance

9.1

Depressurizing the Discharge Line (For Pumps Equipped with a 3-FV or a 4-FV only)

!

CAUTION

32

ALWAYS wear protective clothing, face shield, safety glasses and gloves when performing any maintenance or replacement on your pump.

Page 33

!

Read steps 1 and 2 below before proceeding.

!

Be sure your relief tubing is connected to your multi-function valve and runs back to your solution drum or tank.

CAUTION

CAUTION

1.

2.

9.2

!

CAUTION

Be sure the Injection Check Valve is properly installed and is operating. If a shut off valve has been installed downstream of the Injection Valve, it should be closed.

1/4 turn the black knob on the valve. The discharge line is now depressurized. Keep valve open until solution drains back down the discharge tubing into solution drum or tank. Then 1/4 turn knob to normal position.

Liquifram™ (Diaphragm) Replacement ALWAYS wear protective clothing, face shield, safety glasses and gloves when working near or performing any maintenance or replacement on your pump. See MSDS information from solution supplier for additional precautions. LMI metering pumps are designed for trouble-free operation, yet routine maintenance of elastomeric parts is essential for optimum performance. This involves replacing the Liquifram™, cartridge valves or seal rings/valve balls, multi-function valve cap ­assemblies and the injection check valve spring. LMI ­recommends replacing these parts at least once a year; however, frequency will depend on your particular application. When replacing the Liquifram™ and the cartridge valves or seal rings/valve balls, the injection check valve spring should also be replaced (see next Section 9.3). A Spare Parts Kit (SP-#) or RPM Pro Pac™ kit containing these parts may be ­obtained from your local distributor.

Replacing the Liquifram™: 1.

Carefully depressurize, drain, and disconnect the discharge line (see Section 8.1 in this manual). Place the Foot Valve into a container of water or other neutralizing solution. Turn the pump on to flush the head assembly. Once the pump head has been flushed, lift the Foot Valve out of the solution and continue to pump air into the pump head until the pump head is purged of water or neutralizing solution. 33

Page 34

If the liquid cannot be pumped due to Liquifram™ rupture using protective clothing, gloves and face shield, carefully disconnect the suction and discharge tubing. Remove the four screws to the head and immerse the head in water or other neutralizing solution. 2.

Start the pump. While running, set the stroke knob to zero and turn the pump off.

See Section 10.0 for proper zero . 3. With the unit off, unscrew the Liquifram™ by carefully grasping the outer edge and turning it counter-clockwise . Discard old Liquifram™. Remove the Liquifram™ disk if so equipped (located behind the Liquifram™) and check that the size code matches the size code on the replacement Liquifram™ (see illustration). 4.

!

CAUTION

Reinstall the disk so the alignment pin on the disk (if present) seats in the recessed hole in the EPU.

Be careful not to scratch the Teflon® face of the new Liquifram™.

For Series B, C, & E

5.

34

For Series AA, J, & P

Start the pump and turn the stroke knob to the setting indicated on the following Stroke Setting Chart which matches the pump series number located on the pump dataplate. With the pump stroking (running), screw on the new Liquifram™ clockwise until the center begins to buckle inwards. Stop the pump.

Page 35

Liquifram™ Stroke Setting Chart Pump Series

Stroke Knob Setting

All AA, B, J, P Series C10, C11, C12, C70, C71, C72, C76, C90, C91, C92, E70, E71, E72

90%

C78

50%

C13, C14, C73, C74, C77, C93, C94, E73, E74

70%

* Liquifram™ on M Series pumps only, must be bottomed completely (turned all the way in). Do Not Use Straight Edge.

6.

Grasp the outer edge of the Liquifram™ and adjust by screwing it in or out so that the center of the Liquifram™ is flush with the outside of the spacer edge (see illustration below).

7.

Once the Liquifram™ is properly positioned, remount the pump head to the spacer using the four (4) screws. Tighten in a criss-cross pattern. After one week of operation, recheck the screws and tighten if necessary.

35

Page 36

9.3

Cartridge Valves, Seal Rings/Valve Balls and Injection Check Valve Spring Replacement

!

CAUTION

ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or performing any maintenance or replacement on your pump. See MSDS information from solution supplier for additional precautions. 1.

Refer to the LMI Metering Pump Price List for the proper Spare Parts Kit or RPM Pro Pac™ kit number or contact your local LMI stocking distributor.

2.

Carefully depressurize and disconnect the discharge line (see Section 9.1 in this manual). Place the Foot Valve into a container of water or other neutralizing solution. Turn the pump on to flush the head assembly. Once the pump has been flushed, lift the Foot Valve out and continue to pump to let air into the pump head until pump is purged of water or neutralizing solution.

Once the pump has been flushed, lift the Foot Valve out and continue to let air into the pump head until pump is purged of water or neutralizing solution.

If the liquid cannot be pumped due to Liquifram™ rupture, with protective clothing, gloves and face shield, carefully disconnect the tubing and four screws to remove the head. Immerse the head in water or other neutralizing solution.

Spare part replacement kits include specific instructions for valve replacement. Please follow the instructions included with the replacement kit.

!

IMPORTANT: Before disassembling the check valves, note the orientation of the valve.

CAUTION

3.

Carefully disconnect one tubing connection and fitting at a time, then remove and replace the worn valve.

If necessary, carefully loosen stuck valves by prying side to side using a small screwdriver through the center hole of the valve.

4.

36

Install new check valves in each location.