The text of a manual · part 3 of 5
Electronic Metering Pumps Instruction Manual, pages 19 to 27
Pages 19 to 27 of 44
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the LMI AA751
Page 19
4.6
AutoPrime™ Liquid End
Return to Supply
TM
AutoPrime Valve
Discharge Valve
Discharge
Suction Valve Inlet
AutoPrime™ Liquid End
AutoPrime™ Pumps installed with the AutoPrime™ Liquid End are equipped with a valve that allows for constant removal of vapors and gasses inherent with effervescent chemicals such as Sodium Hypochlorite and Hydrogen Peroxide. The valve keeps the pump primed automatically. When installing a pump equipped with an AutoPrime™ Liquid End, connect the 1/2" OD Polyethylene tubing to the top vertical fitting, and route this line back to the supply tank. To ensure priming, this tubing should not be submerged in the solution. The horizontal fitting is the discharge, and the bottom vertical fitting is the suction. 19
Page 20
4.7
Foot Valve/Suction Tubing Installation The Foot Valve acts as a check valve to keep the pump primed in suction lift applications. The foot valve is designed to be submersed in the solution tank or drum and must sit in a vertical position at the bottom. Position approximately 2 inches (50 mm) off the bottom if the tank or drum contains sediment. Pump models equipped with high-viscosity liquid ends are not equipped with foot valves. Flooded suction is recommended. A 1/2" NPT connector is included for flooded suction installations. The ceramic weight, when installed, positions the foot valve in a vertical position. 1.
Attach the foot valve to one end of the suction tubing (see Tubing Connections, Section 4.3).
2.
Slide the ceramic weight over the tubing end until it contacts the top of the foot valve coupling nut.
3.
Place foot valve and tubing into the solution tank. Check that the foot valve is vertical and approximately 2 inches (50 mm) from the bottom of the tank or drum (see illustration). Connect the other end of the tubing to the suction side of the pump head (bottom side) (see Tubing Connections, Section 4.3). LMI Pump
LMI Pump
Use Ceramic Weight Foot Valve Must Remain Vertical Foot Valve Tilted Sideways WILL NOT PRIME
INCORRECT
20
2.0 in. (50 mm) for Sediment Accumulation
CORRECT
Proper Foot Valve Position
Page 21
4.8
Injection Check Valve and Discharge Tubing Installation
A. Installing Injection Check Valve (Figure 1) 1. Injection Check Valve prevents backflow from a treated line. Install the injection check valve at the location where chemical is being injected into the system. 2. size Female NPT fitting or pipe tee with a reducing bushing to ½" Female NPT will accept the injection check valve. PTFE tape should only be used on threads that are connected with pipes. 3. installing the Injection Check Valve, be sure to position it so that the valve enters the bottom of your pipe in a vertical position. Variations 40° left and right are acceptable. B. Discharge Tubing Note: Cut tubing to length needed for discharge line. 1. tubing from the injection check valve to the metering pump, making sure it does not touch hot or sharp surfaces, or is bent so sharply that it kinks. 2. 4.3 Tubing Connections.
FIGURE 1
21
Page 22
5.0
End Parts List
Reference Liquid End Sheets on LMI Online Library at: www.lmipumps.com. 1. Select “Online Literature Library” in the Navigation Bar on left. 2. on Online Literature Library use “Product” drop down to select “Liquid Handling Assemblies.” 3. Select “Gallery” or ”Index” to view Liquid End sheets.
22
Page 23
6.0
Start-up and Adjustment a.) The pump is normally self-priming if suction lift is 5 ft (1.5m) or less and the steps below are followed. b.) Pumps are shipped from the factory with water in the pump head to aid in priming.
6.1
Output Adjustment Controls Manual series pump controls are not equipped with pressure control. 1.
Pressure Control Adjustment (if equipped): Pressure control provides the adjustment of the pump’s pressure capability and power consumption, reducing heat, pipe shock and pulsation while increasing pump life. See Section 7.0 after priming for proper adjustment settings.
2.
Speed Adjustment (Upper Knob) (if equipped): Speed control provides adjustment of the percent of maximum strokes per minute. Turning this knob clockwise increases stroke frequency (speed).
3.
Stroke Adjustment (Lower Knob): Stroke control provides adjustment of the percent maximum of solution discharged during each pump actuation. Turning this knob clockwise increases solution displacement.
A7 and P7 Only: When operating the pump in external mode, the speed control knob should be turned fully counter-clockwise .
23
Page 24
6.2
!
Start-Up/Priming for Pump Supplied with Multi-Function Valve Read this entire section completely before proceeding.
CAUTION
When all precautionary steps have been taken, the pump is mounted, and the tubing is securely attached, you may now start priming the pump. 1.
Plug in or switch the pump on.
2.
While the pump is running, set the speed knob at 80% and the stroke knob at 100%.
If the pump is equipped with pressure control, turn fully clockwise. 3.
1/4 turn open the relief side (black knob) of the multi-function valve.
4.
The suction tubing should begin to fill with solution from the tank.
5.
A small amount of solution will begin to discharge out the return line of the multi-function valve. Once this happens, 1/4 turn or release the knob and SHUT THE PUMP OFF. (If pump is not equipped with an on/off switch, disconnect the power cord.)
6.
The pump is now primed.
7.
Proceed to output adjustment, Section 6.4.
If the pump does not self-prime, remove the multi-function valve on the discharge side of the pump head. Remove the check valve and pour water or solution into the port until the head is filled. Replace valve, then follow start up/priming steps.
24
Page 25
6.3
Start-Up/Priming without Multi-Function Valve
!
Read this entire section completely before proceeding.
CAUTION
When all precautionary steps have been taken, the pump is mounted, and the tubing is securely attached, you may now prime the pump. 1.
Plug in or switch on the pump.
2.
While the pump is running, set the speed knob at 80% and the stroke knob at 100%.
If the pump is equipped with pressure control, turn clockwise . 3.
The suction tubing should begin to fill with solution from the tank.
4.
Once the solution begins to exit the pump head on the discharge side, SHUT THE PUMP OFF. (If pump is not equipped with an on/off switch, disconnect the power cord).
5.
The pump is now primed.
6.
Proceed to output adjustment, Section 6.4.
If the pump does not self-prime, remove the fitting on the discharge side of the pump head. Remove the ball and pour water or solution into the port until the head is filled. Replace valve, then follow start up/priming steps.
Start-Up/Priming for AutoPrime™ Heads Read this entire section completely before proceeding. When all precautionary steps have been taken, the pump is mounted, and the tubing is securely attached, you may prime the pump. 1. Plug in or switch on the pump. 2. While the pump is running, set the speed knob and the stroke knob at 100%. 3. The suction tubing should begin to fill with solution from the tank as the AutoPrime™ valve purges air from the pump head. 4. Once the solution begins to exit the pump head through both the discharge valve and the AutoPrime™ valve, SHUT THE PUMP OFF. 5. The pump is now primed. 6. Proceed to output adjustment, Section 6.4. 25
Page 26
6.4
Output Adjustment Once the pump has been primed, an appropriate output adjustment MUST be made. Pump output should be calculated and adjustments made accordingly.
6.5
Total Pump Output Calculate the total output of the pump as follows:
PUMP OUTPUT = MAX PUMP OUTPUT x % SPEED x % STROKE
Example: P151-392SI Use MAX Output (from dataplate on bottom center of pump control panel) = 24 GPD (24 gallons per day). If the pump is set at 60% speed and 70% stroke length, the approximate pump output is: 24.0 x 0.60 x 0.70 = 10.08 GPD (gallons per day). Divide by 24 (hours in one day) to calculate in gallons per hour. If pump is not equipped with speed adjustment, calculate by Max Pump Output x % Stroke only.
26
Page 27
27