The text of a manual · part 2 of 5

Electronic Metering Pumps Instruction Manual, pages 10 to 18

Pages 10 to 18 of 44

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the LMI AA751

Page 10

Electrical Connections To reduce the risk of electrical shock, install only on a circuit protected by a ground-fault circuit-interrupter (GFCI). The metering pump must be plugged into a grounded outlet with ratings conforming to the data on the pump control panel. The pump must be connected to a good ground. DO NOT USE ADAPTERS! All wiring must conform to local electrical codes.

WARNING: Do not hook a US style pump plug into a non-US (UK, Aust, NZ or Swiss) wired power system. The US style 240VAC power system has two 110VAC hot legs and one neutral. The European style system has one 240VAC hot leg and a neutral. Hooking up a US pump to the European wired system will cause pump failure.

4.0

Installation

4.1

Pump Location and Installation Locate pump in an area convenient to solution tank and electrical supply. The pump should be accessible for routine maintenance, and should not be subjected to ambient temperatures above 122°F (50°C). If the pump will be exposed to direct sunlight, LMI black, UV resistant tubing should be installed.

4.2

Pump Mounting The pump can be mounted in one of two ways: A. FLOODED SUCTION (ideal installation); or B. SUCTION LIFT - when suction lift is less than 5 feet (1.5 m) for solutions having a specific gravity of water. For denser solutions, consult distributor.

10

Your LMI metering pump must be mounted so that the suction and discharge valves are vertical. NEVER position pump head and fittings horizontally.

Page 11

4.2.1

Flooded Suction The pump is mounted at the base of the storage tank. This installation is the most trouble-free , and is recommended for very low outputs, solutions that gasify, and high-viscosity solutions. Since the suction tubing is filled with solution, priming is accomplished quickly and the chance of losing prime is reduced.

!

CAUTION

When pumping downhill or into low or no pressure system, a back pressure/anti-syphon device should be installed to prevent overpumping or syphoning. Although popular for all solutions, LMI recommends flooded suction installations for all high-viscosity fluid applications.

Tee Injection Check Valve

LMI 35 Gallon Solution Tank

CORRECT

INCORRECT Avoid this type of false flooded suction.

Injection Check Valve

Vent

Polymer (Polyelectrolyte) Drum

LMI Pump

Pump Stand 11 Barrel Cradle

CORRECT

Page 12

4.2.2

Suction Lift - Wall Bracket Mount The pump may be mounted using an LMI Wall Mount Bracket Assembly (part no. 34643) directly above the solution tank. A pump mounted in this manner allows for easy changing of solution tanks or drums. Tee

Injection Check Valve

LMI Pump Rear Mount

LMI Pump Front Mount

Solution Tank

2.0 in. (50 mm) Space for Sediment Accumulation 12

Pressure Line

Page 13

4.2.3

Suction Lift - Tank Mount The pump may be mounted on a molded tank provided there is a recess to keep the pump stationary. LMI 10-gallon tank (part no. 27421), 35-gallon tank (part no. 27400), and 50-gallon tank (part no. 26350) have molded recesses for pump mounting.

Pressure Line

Tee Injection Check Valve LMI Pump

LMI Pump

LMI 50 Gallon Solution Tank

LMI 10 Gallon Solution Tank

Ceramic Weight Foot Valve

Foot Valve 2.0 in. (50 mm) Space for Sediment Accumulation

2.0 in. (50 mm) Space for Sediment Accumulation

13

Page 14

4.2.4

Suction Lift - Shelf Mount The pump may be mounted on a shelf (customer supplied) maintaining a suction lift of less than 5 ft (1.5 m). An LMI mounting kit (part number 10461) is available for securing the pump to a shelf. Flow

Flow Injection Check Valve Anti-Syphon Pressure Relief Valve (Optional Accessory)

Solution Drum 2.0 in. (50 mm) Space for Sediment Accumulation

14

LMI Pump

Page 15

4.3

Tubing Connections

1.   tubing through Coupling Nut - Tubing should enter the smaller end of the Coupling Nut first, orienting the larger opening of the Coupling Nut toward the tubing end. 2a.  1/4” OD tubing: Position the Female Ferrule so that 1/4” to 3/8” (5-10 mm) of tubing protrudes from the Female Ferrule. Orient the raised collar of the Ferrule toward the Coupling Nut (reference FIGURE 1). 2b.  3/8” or 1/2” OD tubing: Position a Female Ferrule about one inch (25 mm) from end of tubing. Orient the raised collar of the Female Ferrule toward the Coupling Nut. Then, insert the Male Ferrule onto the end of the tube, pushing the tube into the bottom of the groove in the Male Ferrule. Then slide the Female Ferrule down the tubing and with your fingers, press tightly into the Male Ferrule (reference FIGURE 2). 3.   hand tighten the Coupling Nut onto the fitting. Note: Tightening with pliers may cause the Ferrules to break.

!

A. only LMI Tubing - ALWAYS use LMI supplied

CAUTION tubing with your pump, as the tubing is specifically designed for use with the pump fittings.

B. NOT USE CLEAR VINYL TUBING ON THE DISCHARGE SIDE OF THE PUMP. The pressure created by the pump can rupture vinyl tubing. C. installation, all tubing must be cut with a clean square end. D. and head connections from the factory are capped or plugged to retain pre-prime water. Remove and discard these caps or plugs before connecting tubing. NOT USE PLIERS OR PIPE WRENCH ON COUPLING NUTS OR FITTINGS. DO NOT REUSE FERRULES - USE ONLY NEW FERRULES. Coupling Nut

Coupling Nut

1/2" O.D. or 9x12mm Tubing

3/8" O.D. or 6x8mm Tubing

1/4" O.D. or 3x6mm Tubing

1/4" - 3/8" (5-10 mm)

FerruleFemale

FerruleFemale

FerruleMale

O-Ring

O-Ring

Fitting

Fitting

FIGURE 1

FIGURE 2 15

Page 16

4.4

Multi-Function Valves Your pump may be equipped with one of the following multifunction valves: 3-FV, 4-FV, or standard discharge valve. If your pump is not equipped with a multi-function valve and you feel it is needed in your application, it can be purchased as an accessory. Contact your local LMI stocking distributor.

4.4.1

Three Function Valve (3-FV) 1.

2.

3.

4.4.2

If the discharge line is over pressurized, the valve opens sending solution back to the supply tank. Line Depressurization Opening the relief knob provides line drain back to the supply tank. Priming Aid Opening the relief knob assists in priming the pump by venting the discharge line to the atmosphere.

Four Function Valve (4-FV) 1.

2.

3.

4.

16

Pressure Relief

Pressure Relief If the discharge line is over pressurized, the valve opens sending solution back to the supply tank. Line Depressurization Opening the relief knob provides line drain back to the supply tank. Anti-Syphon Prevents syphoning when pumping solution downhill or into a vacuum. Back Pressure Supplies approximately 25 psi back pressure to prevent overpumping when little or no system back pressure is present.

Page 17

Flow

Flow

DO NOT submerge return line in solution

LMI 4-FV (Accessory) Prevents syphoning when pumping into suction side of recirculating pump (Vacuum)

LMI 4-FV (Accessory) Prevents over pumping and syphoning when pumping downhill into low or no pressure

Tank

Recirculating Pump LMI Pump

Tank

Injection Check Valve To Injection Point

Typical 4-FV Installation

17

Page 18

4.5

4-Function Valve Installation

• mount to a pump, remove the discharge fitting from the pump (if present) leaving the cartridges in the pump head. Position the 4FV coupling nut on pump head over cartridges with threads up, and insert 4FV fitting and thread into pump head over cartridges. Tighten the fitting to 50 in-lbs using a 13/16” or 20 mm socket. Insert the large opening on the 4-Function valve into the 4FV coupling nut and hand tighten. You can position the valve to have the pressure relief port in any convenient location by tightening the 4FV coupling nut with the pressure relief port positioned 90º CCW from desired location, then holding the nut stationery while turning the valve the final 90º to desired position. • 1/4” tubing to the pressure relief port and route to supply container. • discharge line using LMI tubing connection system or 1/2” pipe thread. 4-Function Valve is designed for double¬ballchecks. A second valve cartridge is required when mounting a new 4-Function Valve to an existing pump with a 300, 400 or 700 liquid end.

4-Function Valve Tubing Connection