Page 1 of Electronic Metering Pumps Instruction Manual

Manual · LMI

Electronic Metering Pumps Instruction Manual

Manual44 pagesPDF 2.2 MB

Instruction manual for LMI electronic metering pumps, Series AA, B, C, E, J5 and P: installation, start-up, calibration and repair.

Download the PDF2.2 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The LMI instruction manual for manually and externally controlled electronic metering pumps of Series AA, B, C, E, J5 and P. It covers unpacking, pre-installation precautions, pump location and mounting (flooded suction or suction lift), tubing, multi-function valves, foot and injection check valves, start-up and priming, output adjustment, external triggering, calibration, spare parts replacement including the Liquifram diaphragm, checking the stroke knob zero position, and troubleshooting.

Its parts

  1. Introduction
  2. Unpacking Check List
  3. Pre-Installation Instructions
  4. Installation
  5. Liquid End Parts List
  6. Start-Up and Adjustment
  7. Methods of External Triggering or Pacing B7, C7 and P7 Pumps
  8. Calibration
  9. Spare Parts Replacement/Routine Maintenance
  10. Checking Pump for Proper Zero Position (Stroke Knob)
  11. Troubleshooting
  12. EPU Resistance Chart

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

An LMI instruction manual (1615.R 7/2010) for manually and externally controlled electronic metering pumps of Series AA, B, C, E, J5 and P. It covers installation, priming, output adjustment, external triggering, calibration, routine parts replacement and troubleshooting. The AA751 is not named; the manual covers the Series AA as a whole.

Read for this summary: pages 1 to 12, 23 to 36 and 40 to 44 of 44.

What it is
Installation, maintenance and troubleshooting manual for Series AA, B, C, E, J5 and P pumps p. 4
Suction lift
5 ft (1.5 m) maximum p. 41
Ambient temperature
Not above 122°F (50°C) p. 10
Output formula
Max pump output x % speed x % stroke p. 26
External trigger
Switch or transistor on 4-pin connector, rated 15V DC at 2 mA; on at least 50 ms, off at least 100 ms p. 28
Power
Grounded outlet on a GFCI protected circuit; no adapters p. 10
Wall bracket
LMI Wall Mount Bracket Assembly, part no. 34643 p. 12
Maintenance interval
Replace Liquifram, valves, seal rings and injection check valve spring at least once a year p. 33
Fittings
Hand-tighten plus 1/8 to 1/4 turn; no Teflon tape or pipe dope on machine threads p. 9
Low injection pressure
Below 25 psi (1.7 Bar) at the injection point, install a 4-FV p. 43
EPU check
Measure coil resistance against the EPU Resistance Chart with the pump fully cooled p. 43, 44
Priming settings
Speed knob at 80%, stroke knob at 100% p. 24
Calibration
Graduated container of 1000 ml or more; 50 pump strokes minimum p. 30

What this manual walks you through

  • Pre-installation precautions for chemicals, tubing and fittings p. 8, 9
  • Mounting the pump for flooded suction or suction lift p. 10, 11, 12
  • Priming with or without a multi-function valve, or an AutoPrime head p. 24, 25
  • Calculating and adjusting pump output p. 23, 26
  • Triggering the pump externally through the 4-pin connector p. 28
  • Calibrating output in internal or external mode p. 30, 32
  • Setting the pressure control p. 31
  • Depressurizing the discharge line and replacing the Liquifram p. 32, 33, 34, 35
  • Replacing cartridge valves, seal rings and the injection check valve spring p. 36
  • Troubleshooting priming, leaks, low output and failure to run p. 40, 41, 42, 43

Good to know

  • Vinyl tubing is for the suction side or valve return line only, never pressurized lines. p. 6
  • A US style pump plug must not be connected to a non-US wired power system. p. 10
  • The suction and discharge valves must be vertical; never mount the head horizontally. p. 10
  • Coil resistance read within 10 hours of operation can be up to 20% higher. p. 44

Questions this manual answers

Why won't my LMI metering pump prime?

Common causes are the pump being off, wrong dial settings, a foot valve not vertical, suction lift above 5 ft, coiled suction tubing or overtightened fittings. p. 40, 41

How do I calculate the output of an LMI pump?

Multiply the maximum output on the dataplate by the percent speed and the percent stroke. p. 26

How often should the LMI Liquifram be replaced?

The manual recommends replacing the Liquifram, valves, seal rings and check valve spring at least once a year. p. 33

What should I check if an LMI pump will not run?

Check that it is on and plugged in, then measure the EPU coil resistance; if the EPU checks out, the pulser should be replaced. p. 42, 43

What signal can trigger an LMI pump externally?

A switch closure, NPN or PNP transistor or opto isolator on the 4-pin connector, able to switch 15V DC at 2 mA. p. 28

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18
  3. Pages 19 to 2719-27
  4. Pages 28 to 3628-36
  5. Pages 37 to 4437-44

The file

Revision and size

Revision1615.R 7/2010
PublisherLMI
Pages44
PDF2.2 MB
TextText from the PDF itself; page 29 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 44

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 44
Page 2
Page 2of 44
Page 3
Page 3of 44