Spec sheet · LMI
LMI Series AA Electronic Metering Pumps Specification Sheet
Spec sheet2 pagesPDF 481 KB
Both pages are below, each with its text.
Filed with · 1 model
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
An LMI specification sheet (1977.A 08/03) for Series AA electronic metering pumps, covering the AA1, AA7 and AA9 series in five output sizes. It states the output and pressure of each size, the controls, the drive, the automatic pressure relief, the materials and the tubing and valves supplied. It helps a reader confirm what an AA75 series pump should deliver.
- What it is
- Positive displacement Liquifram type chemical metering pump p. 1
- AA75 output
- AA15, AA75, AA95: adjustable up to 1.0 GPH p. 1
- AA75 pressure
- AA15, AA75, AA95: up to 110 psig (7.6 bar) p. 1
- AA7 control
- Switch on the frequency knob selects internal or external pulsing; stroke length set by dial knob p. 1
- Power consumption
- Not over 22 watts per hour at full speed and maximum pressure p. 1
- Weight
- Not over 14 lbs (6.5 kg) p. 1
- Pressure relief
- Stops pulsing when discharge pressure exceeds the rating by not more than 35% p. 1
- Tubing supplied
- 16 ft (4.8 m) of polyethylene tubing with compression connections p. 1
- Valves supplied
- Foot valve with strainer; injection check valve with 1/2" NPT male connection p. 1
- Standard materials
- Glass fiber reinforced thermoplastic housing, ceramic balls, transparent acrylic head, PVC fittings p. 1
- Pulser terminals
- Quick connect terminals at least 3/16" (4.75 mm) wide p. 1
- AA9 stroke rate
- AA9: 1 stroke per hour to 100 strokes per minute p. 1
What this sheet walks you through
- Output and pressure capacity of each Series AA size p. 1
- Controls of the AA1, AA7 and AA9 series p. 1
- Optional materials for balls, seats, head and fittings p. 1
Good to know
- In external pulsed mode the AA7 needs no electrical or internal timer. p. 1
- Vinyl suction tubing of 6 ft (1.8 m) may replace polyethylene on the suction side only. p. 1
Questions this sheet answers
What pressure can an LMI AA75 pump inject against?
Up to 110 psig (7.6 bar) for the AA15, AA75 and AA95. p. 1
Does an LMI Series AA pump need a pressure relief valve?
The sheet says the Liquifram stops pulsing on its own when discharge pressure exceeds the rating by not more than 35%. p. 1
How do I switch an LMI AA7 pump to external pulsing?
Turn the frequency control knob to its External position, which is below the lowest internal frequency setting. p. 1
What tubing comes with an LMI Series AA pump?
16 ft (4.8 m) of polyethylene tubing with compression connections, plus a foot valve and an injection check valve. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Specification Sheet Series AA Electronic Metering Pumps GENERAL Chemical metering pumps shall be positive displacement, Liquifram“ type pumps that are UL, CUL and CE approved. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity of: AA17, AA77, AA97 - 0.42 GPH AA14, AA74, AA94 - 0.58 GPH AA18, AA78 - 0.75 GPH AA15, AA75, AA95 - 1.0 GPH AA16, AA76, AA96 - 2.0 GPH
(1.6 liters per hour) (2.2 liters per hour) (2.8 liters per hour) (3.8 liters per hour) (7.6 liters per hour)
Chemical metering pumps shall be capable, without a hydraulically backed diaphragm, of injecting solutions against pressures up to: AA14, AA74, AA94 - 250 psig (17.3 bar) AA17, AA77, AA97 - 140 psig (9.7 bar) AA15, AA75, AA95 - 110 psig (7.6 bar) AA18, AA78 - 80 psig (5.5 bar) AA16, AA76, AA96 - 50 psig (3.5 bar) SERIES AA1 Adjustment shall be by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency. Both knobs are to be located opposite the liquid handling end. On-off switch shall be integral with frequency control, "off" position to be below lowest frequency setting. SERIES AA7 Control of Series AA7 metering pumps shall be selectable between internal and external pulsing by means of a switch integral with frequency control knob. "External" position to be below lowest internally paced frequency setting. Stroke length shall be adjustable by means of readily accessible dial knob. When in external pulsed mode, Series AA7 units shall accept signals without the use of electrical timer or internal timer. SERIES AA9 Series AA9 metering pumps shall have a clear liquid crystal display. Control
shall be selectable between internal and external pulsing by means of a tactile keypad. Internal stroke frequency shall be adjustable from 1 stroke per hour to 100 strokes per minute. Pressure capacity shall be keypad adjustable to reduce noise, vibration and wear. Metering pump shall be capable of dividing or multiplying pulse inputs from 1 to 999 or responding directly or inversely to a 4-20mA input signal. DRIVE The pump drive shall be totally enclosed with no exposed moving parts. Solid state electronic pulser shall be fully encapsulated and supplied with quick connect terminals at least 3/16" (4.75 mm) wide. Electronics shall be housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Electrical power consumption shall not exceed 22 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 14 lbs (6.5 kg). AUTOMATIC PRESSURE RELIEF To eliminate need for pressure relief valve, LiquiframTM shall automatically stop pulsating when discharge pressure exceeds pump pressure rating by not more than 35%. MATERIAL Chemical metering pump housing shall be of chemically resistant glass fiber reinforced thermoplastic. All exposed fasteners shall be stainless steel. Chemical metering pump valves shall be ball type, with ceramic balls1. Valve seat and seal ring shall be renewable by replacing the combination seat-seal ring2 or cartridge valve assembly. Pump head shall be of transparent acrylic3 material capable of resisting the pumped chemical. Fittings and connections at pump head shall be PVC4. CHECK VALVES AND TUBING A total of 16 ft (4.8 m) of polyethylene tubing5 shall be provided per pump complete with compression connections. A foot valve with integral one piece strainer shall be provided for the suction line, and an injection check/back pressure6 valve with 1/2" NPT male connection for the injection point. The injection check valve shall incorporate a dilating orifice which prohibits scale formation and accumulation of crystalline deposits.
Notes: 1. Type 316 stainless steel or PTFE may be specified.
2. Hypalon¤ , PTFE or Polyprel¤ may be specified.
3. PVDF, PVC, Polypropylene, or Type 316 stainless steel may be specified.
4. PVDF, Polypropylene, or Type 316 stainless steel may be specified.
5. 6 ft. (1.8 m) of vinyl suction tubing may be specified in place of polyethylene for the suction side only. 1/4" pipe thread may be specified. 201Ivyland Ivyland Road Road 201 PA 18974 Ivyland,Ivyland, PA 18974 USA TEL:(215) (215) 293-0401 293-0401 TEL: FAX: (800) 327-7563 FAX: (800) 327-7563 http://www.Imipumps.com http://www.Imipumps.com
ISO 9001 Certified
1977.A 08/03
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
' 2003 LMI Milton Roy - All Rights Reserved Printed in USA Specifications subject to change without notice.
Polyprel is a registered trademark of Liquid Metronics Incorporated. Liquifram, Liquitron, Micropace are trademarks of Liquid Metronics Incorporated. Hypalon and Viton are registered trademarks of E. I. du Pont de Nemours & Co., Inc.