Page 1 of LMI Series AA Electronic Metering Pumps Data Sheet

Spec sheet · LMI

LMI Series AA Electronic Metering Pumps Data Sheet

Spec sheet2 pagesPDF 2.3 MB

Both pages are below, each with its text.

Download the PDF2.3 MB

Filed with · 1 model

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page LMI data sheet for Series AA electronic metering pumps (AA14 to AA97). It explains how the model number is built from control, output, voltage and liquid end codes, and lists the liquid end materials, tubing and output ranges. It lets a reader decode a model number such as one in the AA75 series.

What it is
Series AA electronic metering pump configuration data p. 1
Control code 7
Manual speed and stroke length control plus switch conversion to external control p. 1
Output code 5
1.00 GPH (3.8 l/h) at up to 110 psi (7.6 Bar) p. 1
Voltage code 1
120 VAC, US plug p. 1
Input power
22 watts average at max speed p. 1
Shipping weight
10 lbs (4.55 kg) p. 1
Model number layout
Series, control code, output code, voltage code, then liquid end code, as in AA 9 4 1 - 358HI p. 1
Other control codes
1 manual control; 9 microprocessor with external 4-20mA or pulse input p. 1
4FV valve
Four Function Valve: anti-syphon and pressure relief, aids priming p. 2
AV valve
Auto Prime Valve for constant removal of vapors and gases p. 2
3FV valve
Three Function Valve: pressure relief, priming aid, line drain p. 2
Fluorofilm
Copolymer of PTFE and PFA p. 2

What this sheet walks you through

  • Decoding the Series AA model number p. 1
  • Choosing a liquid end by materials and tubing p. 2
  • Changing liquid end code letters for fittings, tubing and valves p. 2
  • Output ranges and maximum injection pressure by series p. 2

Good to know

  • Minimum output is based on one stroke per minute. p. 2
  • Only Series 9 pumps can be programmed for strokes per hour. p. 1

Questions this sheet answers

What does output code 5 mean on an LMI Series AA pump?

Output code 5 is 1.00 GPH (3.8 l/h) with a pressure of 110 psi (7.6 Bar). p. 1

What does control code 7 mean on an LMI AA pump?

Manual speed and stroke length adjustment, plus a switch to change over to external control for automatic systems. p. 1

What is a 4FV on an LMI metering pump?

A Four Function Valve on the pump head: a diaphragm anti-syphon and pressure relief valve that also aids priming. p. 2

How do I order a liquid end with 1/4 NPT male connections?

Change the letter I in the liquid end code to P. p. 2

The file

Size and text

Pages2
PDF2.3 MB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of LMI Series AA Electronic Metering Pumps Data Sheet

The text of page 1, from the PDF itself

DataSheet

Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1 - 358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument Responsive/Manual Control: Manual adjustment features of Control Code 1 plus switch conversion to external control for automatic systems. 9 --- Microprocessor/Instrument Responsive: External 4-20mA or pulse or x direct; manual stroke length control. Output/Size Code 4 --- 0.58 GPH (2.2 l/h) --- 250 psi (17.3 Bar) 5 --- 1.00 GPH (3.8 l/h) --- 110 psi (7.6 Bar) 6 --- 2.00 GPH (7.6 l/h) --- 50 psi (3.5 Bar) 7 --- 0.42 GPH (1.6 l/h) --- 140 psi (9.7 Bar) 8 --- 0.75 GPH (2.8 l/h) --- 80 psi (5.5 Bar) Voltage Code 1 --- 120 VAC, US Plug 2 --- 240 VAC, US Plug 3 --- 220-240 VAC, DIN Plug 5 --- 240-250 VAC, UK Plug 6 --- 240-250 VAC, Aust./NZ Plug 7 --- 220-240 VAC, Swiss Plug

Dimensions

Liquid End See next page for complete liquid end specifications and selection.

Specifications Series

Strokes Per Minute (Adjustable) Min Max

AA14, AA74, AA94* AA15, AA75, AA95* 1 AA16, AA76, AA96* AA17, AA77, AA97* AA18, AA78

1

Stroke Length (Adjustable) Recommended Minimum

10020%10030%

Average Input Power @ Max Speed

Shipping Weight22 watts10 lbs (4.55 kg)

*Series 9 pumps may be programmed for strokes per hour for lower outputs.

201 Ivyland Road Ivyland, PA 18974 TEL: (215) 293-0401 FAX: (800) 327-7563 http://www.Imipumps.com

ISO 9001 Certified

Page 2 of LMI Series AA Electronic Metering Pumps Data Sheet

The text of page 2, from the PDF itself

Configuration Data & Materials of Construction Drive Assembly

Li quid End No.Size CodeHead & FittingsBalls

Materials of Construction Liquifram“

Check Valve

Accessory

458HI 450FI 450HI 358HI 353HI 352HI 155HV 155S** 156HV 257

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

PVC / PVC Acrylic / PVC Acrylic / PVC PVC / PVC PVDF / PVDF PVDF / PVDF Polypropylene Polypropylene Acrylic/PP 316 S.S.

Ceramic PTFE Ceramic Ceramic Ceramic Ceramic 316 S.S. Ceramic 316 S.S. 316 S.S.

Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“

PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / PTFE PVDF / Polyprel¤ PTFE PTFE Hypalon¤ 316 S.S.

4FV + AV 4FV 4FV + AV 4FV + AV 4FV + AV 4FV + AV

498HI 490HI 490FI 398HI 392HI 393HI 85HV 86HV 89 95S** 297

0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9

PVC / PVC Acrylic / PVC Acrylic / PVC PVC / PVC PVDF / PVDF PVDF / PVDF Polypropylene Acrylic / PP UHMW PE Polypropylene 316 S.S.

Ceramic Ceramic PTFE Ceramic Ceramic Ceramic 316 S.S. 316 S.S. Ceramic Ceramic 316 S.S.

Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Hypalon¤ Fluorofilm“ Fluorofilm“

PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / PTFE PTFE Hypalon¤ Hypalon¤ PTFE 316 S.S.

4FV + AV 4FV + AV 4FV 4FV + AV 4FV + AV 4FV + AV

468HI 460HI 460FI

  • 368HI
  • 362HI
  • 363HI 65S** 75HV 76HV 79 277

1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8

PVC / PVC Acrylic / PVC Acrylic / PVC PVC / PVC PVDF / PVDF PVDF / PVDF Polypropylene Polypropylene Acrylic / PP UHMW PE 316 S.S.

Ceramic Ceramic PTFE Ceramic Ceramic Ceramic Ceramic 316 S.S. 316 S.S. Ceramic 316 S.S.

Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Fluorofilm“ Hypalon¤ Fluorofilm“

PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / Polyprel¤ PVDF / PTFE PTFE PTFE Hypalon¤ Hypalon¤ 316 S.S.

4FV + AV 4FV + AV 4FV 4FV + AV 4FV + AV 4FV + AV 4FV

AA97 AA94 AA77 AA74 AA17 AA14

-

AA95 AA78 AA75 AA18 AA15

-

AA96 AA76 AA16

See front page for voltage code specifications. **

These Liquid Ends are available without a 4FV, by removing the S from the liquid end code. To specify 1/4 NPT male, change ’I’ to ’P’. To specify black, UV resistant tubing, change ’I’ to ’U’. To specify Bleed 4FV, change ’H’ to ’B’. To specify 3FV, change ’H’ to ’T’. To specify 4FV only, change ’H’ to ’S’. To specify Auto Prime Valve only, change ’H’ to ’A’.

4FV

4FV

Tubing & Connections Discharge Suction

PE .250" O.D. PE .250" O.D. PE .250" O.D. PE .250" O.D. PE .250" O.D. PE .250" O.D. PE .5" O.D. Vinyl .938" O.D. PE .250" O.D. PE .5" O.D. Vinyl .938" O.D. Pipe 1/4" NPT M PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .5" O.D. Vinyl .938" O.D PE .5" O.D. Vinyl .938" O.D.. PE .5" O.D. Vinyl .5" O.D. PE .375" O.D. Pipe 1/4" NPT M PE .375" O.D.. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .375" O.D. PE .5" O.D. Vinyl .938" O.D. PE .5" O.D. Vinyl .938" O.D. PE .5" O.D. Vinyl .5" O.D. Pipe 1/4" NPT M

3FV indicates that the pump is equipped with a Three Function Valve (pressure relief, priming aid, line drain).

Fluorofilm“ is a copolymer of PTFE and PFA. Polyprel¤ is an elastomeric PTFE copolymer.

4FV indicates that the pump is equipped with a Four Function Valve. This diaphragm type, antisyphon/pressure relief valve is installed on the pump head. It provides anti-syphon protection and aids priming, even under pressure.

Hypalon is a registered trademark of E. I. du Pont de Nemours & Co., Inc.

AV indicates that the pump is equipped with an Auto Prime Valve. This valve allows for the constant removal of vapors and gases present in applications such as sodium hypochlorite and hydrogen peroxide.

Output Information Series

AA94*, AA74*, AA14 AA95*, AA75*, AA15 AA96*, AA76*, AA16 AA97*, AA77*, AA17 AA78*, AA18

Gallons per Hour Min Max

0.001 0.002 0.004 0.001 0.002

0.58 1.00 2.00 0.42 0.75

Liters per Hour Min Max

0.004 0.008 0.015 0.005 0.009

2.2 3.8 7.6 1.6 2.8

mL/cc per Minute Min Max

mL/cc per Stroke Min Max

0.07 0.13 0.25 0.08 0.14

0.07 0.13 0.25 0.08 0.14

37 63 126 26 47

0.37 0.63 1.26 0.26 0.47

Maximum Injection Pressure

250 psi (17.3 Bar) 110 psi (7.6 Bar) 50 psi (3.5 Bar) 140 psi (9.7 Bar) 80 psi (5.5 Bar)

  • Minimum output is based on one stroke per minute. Minimum output can be reduced further in external mode. Series AA9 pumps may be programmed for strokes per hour for lower outputs.