Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Series 45: Direct solenoid and solenoid pilot operated valves

Spec sheet · MAC Valves

Series 45: Direct solenoid and solenoid pilot operated valves

Spec sheet18 pagesPDF 636 KB

Catalog pages for MAC Valves Series 45 solenoid valves: inline, sub-base, stacking and manifold models, ordering codes and specs.

Download the PDF636 KB

Covers · 1 model

The models it covers

Summary

What is in it

Catalog pages for the MAC Valves Series 45 direct solenoid and solenoid pilot operated 4/2 valves. They cover inline, sub-base, stacking and manifold mounted versions, including manifolds with pressure regulators and flow controls, with piping options (4-way, 3-way, 2-way, diverter, selector), how-to-order part numbers, solenoid operator voltage and connector codes, technical data, spare parts and metric dimensions for each version.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

MAC Valves catalog pages for the Series 45 direct solenoid and solenoid pilot operated 4/2 valves, in inline, individual sub-base, stacking and manifold sub-base versions, some with regulators and flow controls. They give the technical data, ordering numbers, spare parts, dimensions and the option codes for voltage, wire length, manual operator and electrical connection. They help a reader identify or reorder a Series 45 valve.

What it is
4/2 solenoid valve with bonded balanced poppets, single or double solenoid or remote air p. 1, 3
Fluid
Compressed air, vacuum, inert gases p. 4
Pressure range
Vacuum to 120 PSI p. 4
Temperature range
0°F to 120°F (-18°C to 50°C) p. 4
Ports
#10-32 UNF or 1/8" NPTF p. 3
Max flow
Inline 0.15 Cv; individual sub-base 0.13 Cv; stacking 0.20 Cv; manifold sub-base 0.11 Cv p. 3, 5, 7, 9
Power
AC inrush 10.9 VA, holding 7.7 VA; DC 1.8 to 12.7 W p. 4
Standard voltages
120/60, 110/50; 240/60, 220/50; 24/60, 24/50; 24 VDC at 1.8, 5.4 or 12.7 W p. 3
Response time
24 VDC (5.4 W): energize 6 ms, de-energize 2 ms; 120/60: 3-8 ms and 2-7 ms p. 4
Voltage tolerance
-15% to +10% of nominal voltage p. 4
Filtration and lube
40 µ filtration; lubrication not required p. 4
Spare parts
Mounting screws 35013; seal between solenoid and valve body 16402 p. 4
Manifold parts
Sub-base manifold: end plate kit M-45008-01, seal between bases 16455, tie-rod 19753, isolators N-45008, N-45009, N-45010 p. 9, 10
Double operator
Minimum DC wattage 5.4W p. 3

What this sheet walks you through

  • Piping the valve as 4-way, 3-way, 2-way, diverter or selector p. 2
  • Ordering inline valves, with or without flow controls p. 3, 4
  • Ordering valves on individual sub-bases p. 5, 6
  • Ordering stacking manifold valves p. 7, 8
  • Ordering manifold sub-base valves, with regulators and flow controls p. 9, 10, 11, 12, 13, 14
  • Reading the solenoid operator option codes p. 16, 17, 18
  • Valve dimensions in millimeters p. 4, 6, 8

Good to know

  • If lubricated, use a medium aniline point lubricant (between 180°F and 210°F). p. 4
  • Conduit electrical connections are for inline valves only in the 35 and 45 series. p. 18
  • The 12.7 W DC solenoids, codes DE and DF, are CLSF only. p. 17

Questions this sheet answers

What pressure can a MAC 45 Series valve handle?

Vacuum to 120 PSI, on compressed air, vacuum or inert gases. p. 4

Can a MAC Series 45 valve be used as a 3-way or 2-way valve?

Yes. The balanced poppet lets it be piped 4-way, 3-way or 2-way, normally closed or open, by plugging ports. p. 1, 2

What does voltage code DA mean on a MAC solenoid?

DA is 24 VDC (5.4 W). p. 17

Does a MAC 45 Series valve need lubrication?

No. Lubrication is not required; if used, pick a medium aniline point lubricant. p. 4

How fast does a MAC 45 Series valve respond?

At 24 VDC (5.4 W) it energizes in 6 ms and de-energizes in 2 ms. p. 4

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18

The file

Size and text

PublisherMAC Valves
Pages18
PDF636 KB
TextText from the PDF itself.

The first pages · 4 of 18

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 18
Page 2
Page 2of 18
Page 3
Page 3of 18
Page 4
Page 4of 18