Page 1
Direct solenoid and solenoid pilot operated valves
Series 45 Individual mounting inline
Series sub-base non”plug-in”
35
Manifold mounting stacking sub-base non”plug-in” sub-base with pressure regulators sub-base with pressure regulators and flow controls
100
Manual operator
200 Armature
Epoxy encapsulated solenoid
Push pin
Spring biased moveable pole piece
55 56 57 58 59
A
EXH.
45
700
B
Spring return
IN
Bonded balanced poppets
900 82 6300
SERIES FEATURES • Single and double solenoid or remote air. • The patented MACSOLENOID® for fastest possible response times. • Bonded balanced poppets for high flow, precise repeatability, and consistent operation. • Balanced poppet design permits versatility in pipping. Valves can be piped as 4-way, 3-way or 2-way, normally closed or normally open or can be used for vacuum, diverter or selector applications. • Use on lube or non-lube service. • Extremely high cycle rates. • Extremely long service life due to unique poppet cushions. • Manual overrides as standard. • Various solenoid enclosures and plug-in connectors • Optional surge suppression available. • Low wattage DC solenoids, down to 1.8 watts. • Patented MACSOLENOID®, virtually burn-out proof on AC service.
65
6500 6600 1300 800 ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 2
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series 45
VALVE CONFIGURATIONS AVAILABLE
• 2-position single and double solenoid or remote air. • Single pressure (4 or 5 ports) • Individual, stacking and manifold base mounted models. • Integral individual exhaust flow controls with common exhaust port. • Integral regulators and flow controls on manifolds. SPECIAL APPLICATIONS :
The balanced poppet design facilities using the same valve for many functions and can be used for pressure, vacuum or plugged without the necessity of changing any parts. Pipping suggestions are shown in the chart below.
B
A
B-PLUGGED
A
B
X
IN
EXH
4-WAY
B-PLUGGED
X
IN
EXH
3-WAY NORMALLY CLOSED
A
B
A-PLUGGED
IN
EXH
3-WAY NORMALLY OPEN
B
A
IN
EXH-PLUGGED
X
X X IN
A-PLUGGED
EXH-PLUGGED
2-WAY NORMALLY CLOSED
X IN
EXH-PLUGGED
2-WAY NORMALLY OPEN
X DIVERTER
B
Operator Energized
A-PLUGGED
X
Operator De-Energized
IN
EXH
PRESS OR VAC
PRESS OR VAC
SELECTOR "A" CAN BE USED AS SELECTOR PORT OUTLET IF DESIRED
66
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 3
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
Flow (Max)
4/2
#10-32 - 1/8”
0.15 Cv
Individual mounting
Series inline
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Port size
Double operator (Minimum DC wattage 5.4W)
Single operator A
A
B
EXH
A B
A
B
EXH
IN
55 56 57 58 59
B
IN
1/8” NPTF
45A-AA1-DXXX-XXX
45A-GA1-DXXX-XXX
# 10-32 UNF
45A-AB1-DXXX-XXX
45A-GB1-DXXX-XXX
Single operator
Double operator (Minimum DC wattage 5.4W)
45
WITH INTEGRATED FLOW CONTROLS Port size
A
A
B
EXH
A B
A
B
EXH
IN
B
IN
1/8” NPTF
45A-AA2-DXXX-XXX
45A-GA2-DXXX-XXX
# 10-32 UNF
45A-AB2-DXXX-XXX
45A-GB2-DXXX-XXX
D XX X- X XX
SOLENOID OPERATOR ®
700 900 82
*
6300 XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD JB JD BA
Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads
* Other options available, see page 353. BOTTOM PORT OPTIONS
6500 6600 1300 800
( O ’ RING MOUNT )
ISO 1 ISO 2 ISO 3
45A-XXX-D XXX-XXX
D-Sgl. oper. - All ports F-Sgl. oper. - “A” & “B” ports H-Dbl. oper. - All ports J-Dbl. oper. - “A” & “B” ports
MAC125A MAC250A MAC500A 67
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 4
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.1 Cv), 5.4 W : (0.15 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Valve cover plate with flow controls : N-45002.
Options :
• BSPP threads. • High flow up to 0.23 Cv, according to wattage and high flow Mod. • NAMUR interface - 45A-FA1DXXX-XXX and required NAMUR adapter kit: N-45028-03 (for 3-way operation) - N-45028-04 (for 4-way operation).
DIMENSIONS
Dimensions shown are metric (mm) 62,0
F
G
33,5
A
B H
E
27,5
IN 24,5
EX
22,5 D
A
C 32,5 18,0
B
10,0
16,0
3,5
EX
9,0
IN
15,0 30,0
A
B
23,5
6,5
Port size
A
B
C
D
E
F
G
H
1/8” NPTF
7.5
16.0
10.0
9.5
7.5
11.5
14.5
9.5
# 10-32 UNF
9.75
14.0
10.5
9.75
9.75
13.0
11.0
9.75
68
Ø 3,4
9,5 13,8 14,5
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 5
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
Flow (Max)
Individual mounting
4/2
#10-32 - 1/8”
0.13 Cv sub-base non”plug-in”
Series
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Single operator
Port size
A
A
B
EXH
Double operator (Minimum DC wattage 5,4W) A B
A
B
EXH
IN
B
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAA-DXXX-XXX
45A-NAA-DXXX-XXX
#10-32 UNF base
45A-LBA-DXXX-XXX
45A-NBA-DXXX-XXX
Single operator
Double operator (Minimum DC wattage 5,4W)
WITH INTEGRATED FLOW CONTROLS Port size
A
A
B
EXH
B
A B
A
EXH
IN
55 56 57 58 59
B
45
700 900
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAB-DXXX-XXX
45A-NAB-DXXX-XXX
#10-32 UNF base
45A-LBB-DXXX-XXX
45A-NBB-DXXX-XXX
SOLENOID OPERATOR ®
D XX X- X XX *
82 6300 6500
XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD BA
Square connector Square connector with light Flying leads
6600 1300 800
* Other options available, see page 353.
ISO 1 ISO 2 ISO 3
OPTIONS
45A-LAA-D XXX-XXX
Substitute “J” for 1/8” bottom cylinder ports
MAC125A MAC250A MAC500A 69
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 6
100%
WARRANTY
18
OF PRODUCTION TESTED
100%
MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.11 Cv), 5.4 W : (0.13 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Flow control : N-45018.
Options :
• BSPP threads. • High flow up to 0.20 Cv, according to wattage and high flow mod.
DIMENSIONS
Dimensions shown are metric (mm) 4.5 DIA. (2) places A
B
EA
4,0
21,5
OPTIONAL PRESSURE SENSING PORT
1/8” NPTF OPTIONAL BOTTOM CYLINDER PORTS
CL
EB
IN
5,0 A
B
7,0 14,5 24,0 9,0
12,0
6,5
B A
~24.5
33 25,0 B EB
50,0
IN
50
79,1 A
EA
A
IN
D
EB
EA
13,0 C
C 15,1
32,0
16,0 32,0
64,0
70
Port size
A
B
C
D
1/8” NPTF
16.0
8.0
13.0
8.0
# 10-32 UNF
12.0
6.0
15.0
10.0
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 7
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
Flow (Max)
4/2
# 10-32 - 1/8”
0.20 Cv
Manifold mounting
Series stacking
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Port size
Double operator (Minimum DC wattage 5,4W)
Single operator A
A
B
EXH
B
A B
A
EXH
IN
55 56 57 58 59
B
IN
1/8” NPTF
45A-SA1-DXXX-XXX
45A-TA1-DXXX-XXX
# 10-32 UNF
45A-SB1-DXXX-XXX
45A-TB1-DXXX-XXX
Single operator
Double operator
45
WITH INTEGRATED FLOW CONTROLS Port size
A
A
B
EXH
A B
A
B
EXH
IN
B
IN
1/8” NPTF
45A-SA2-DXXX-XXX
45A-TA2-DXXX-XXX
# 10-32 UNF
45A-SB2-DXXX-XXX
45A-TB2-DXXX-XXX
D XX X- X XX
SOLENOID OPERATOR ®
700 900 82
*
6300 XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD BA
Square connector Square connector with light Flying leads
6500 6600 1300
* Other options available, see page 353.
800
End plate kit required (Port size 1/4” NPTF) : M-45001-01.
ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A 71
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 8
100%
WARRANTY
18
OF PRODUCTION TESTED
100%
MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.14 Cv), 5.4 W : (0.2 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between valves : 16422. • Tie-rod (x2) : 19813. • Valve cover plate with flow controls : N-45004. • Inlet & exhaust isolator : N-45005. Inlet isolator : N-45006. Exhaust isolator : N-45007
Options :
• BSPP threads. • High flow up to 0.3 Cv, according to wattage and high flow mod.
DIMENSIONS
Dimensions shown are metric (mm) 32,5 7,0 ± 0,2
EX
4 × Ø 5,3 62,5
A
A
B
B
39,0
9,95
IN
9,5
A
A
15,5
B
IN EX
18,5 B
16,0
16,0 8,0 7,5
17,0 49,0
9,5 4,0 1/8” NPTF CYLINDER PORTS
54,0
19,2 (± 0,1)
12,0 ± 0,2 # 10-32 UNF CYLINDER PORTS
EX
1/4” IN & EXH. NPTF IN
EX
44,0
IN
62,5
72
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 9
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
Flow (Max)
Manifold mounting
4/2
# 10-32 - 1/8”
0.11 Cv sub-base non”plug-in”
Series
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Single operator
Port size
A
A
B
EXH
Double operator (Minimum DC wattage 5.4W) A B
A
B
EXH
IN
B
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAC-DXXX-XXX
45A-NAC-DXXX-XXX
# 10-32 UNF base
45A-LBC-DXXX-XXX
45A-NBC-DXXX-XXX
Single operator
Double operator (Minimum DC wattage 5.4W)
WITH INTEGRATED FLOW CONTROLS Port size
A
A
B
EXH
A B
A
B
EXH
IN
55 56 57 58 59
B
45
700 900
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAD-DXXX-XXX
45A-NAD-DXXX-XXX
# 10-32 UNF base
45A-LBD-DXXX-XXX
45A-NBD-DXXX-XXX
SOLENOID OPERATOR ®
D XX X- X XX *
82 6300 6500
XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD BA
Square connector Square connector with light Flying leads
6600 1300 800
* Other options available, see page 353.
ISO 1 ISO 2 ISO 3
End plate kit required (Port size 1/4” NPTF) : M-45008-01
MAC125A MAC250A MAC500A 73
Consult “Precautions” page 356 before use, installation or service of MAC Valves.