The text of a spec sheet · part 2 of 2
Series 45: Direct solenoid and solenoid pilot operated valves, pages 10 to 18
Pages 10 to 18 of 18
The original document is the PDF (636 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the MAC Valves 45 Series
Page 10
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Side cover plate with flow controls : N-45016. • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
Options :
• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.
DIMENSIONS
Dimensions shown are metric (mm)
1/8” NPTF CYLINDER PORTS
# 10-32 UNF PORTS CYLINDER
10,0
20,5
OPTIONAL 1/8” NPTF BOTTOM INLET 62,5
17,5
B
51,0
B
IN A
A
8,0
8,5
8,0
4,0
4,0
20,10 ±0,1 Ø 5,3 MTG. SLOT
33
9,0 OPTIONAL ISOLATOR
1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS 2,5
IN
9,75 29,0
13,5 EX
18,9 13,7
5,2 71,1
17,3
74
19,0
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 11
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
Flow (Max)
Manifold mounting
4/2
# 10-32 - 1/8”
0.11 Cv sub-base with pressure regulators
Series
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Single operator
Port size
A
A
B
EXH
Double operator (Minimum DC wattage 5,4W) A B
A
B
EXH
IN
55 56 57 58 59
B
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAJ-DXXX-XXX
45A-NAJ-DXXX-XXX
# 10-32 UNF base
45A-LBJ-DXXX-XXX
45A-NBJ-DXXX-XXX
SOLENOID OPERATOR ®
D XX X- X XX *
45
700
XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD BA
Square connector Square connector with light Flying leads
900 82 6300
* Other options available, see page 353.
6500
End plate kit required (Port size 1/4” NPTF) : M-45008-01. Options (with gauge port) : Single operator : replace L by M. Double operator : replace N by P.
6600
REGULATOR OPTIONS
45A-XXJ-D XXX-XXX
1300
(“J” is for Adj. knob)
Replace with “E” for slotted stem Replace with “G” for locking slotted stem
800 ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A 75
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 12
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Pressure regulator : 45A-00R (Adj. Knob), 45A-00L (Slotted Stem), 45A-00M (Locking Slotted Stem). • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
Options :
• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow mod. • Bottom inlet : specify Mod. 0210.
DIMENSIONS
Dimensions shown are metric (mm) 1/8” NPTF CYLINDER PORTS OPTIONAL 1/8” NPTF BOTTOM 62,5 INLET
# 10-32 UNF PORTS CYLINDER
17,5
B
10,0
20,5
51,0
B
IN A
A
8,0
8,5
8,0
4,0
4,0
20,10 ±0,1 33,0
Ø 5,3 MTG. SLOT 9,0 ± 0,2 1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS
OPTIONAL ISOLATOR 2,5
IN
9,75
13,5
13,5
29,0
EX
14,0
13,7
OPTIONAL GAGE PORT
18,9
17,3
5,2
19,0
102,1 REGULATOR W/ SLOTTED STEM
71,1
76
Ø 15,5
13,4 LOCKING KNOB
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 13
Direct solenoid and solenoid pilot operated valves
Series 45 Function
Port size
4/2
# 10-32 - 1/8”
Flow (Max)
Manifold mounting
0.11 Cv sub-base with pressure regulators and flow controls
Series
OPERATIONAL BENEFITS
35
1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.
100 200
HOW TO ORDER
Single operator
Port size
A
A
B
EXH
Double operator (Minimum DC wattage 5,4W)
B
A B
A
EXH
IN
B
IN
Valve less base
45A-L00-DXXX-XXX
45A-N00-DXXX-XXX
1/8” NPTF base
45A-LAK-DXXX-XXX
45A-NAK-DXXX-XXX
# 10-32 UNF base
45A-LBK-DXXX-XXX
45A-NBK-DXXX-XXX
SOLENOID OPERATOR ®
D XX X- X XX *
45
700
XX
Voltage
X
Wire length
X
Manual operator
XX
Electrical connection
AA AB AC FB DA DF
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)
A J
18” (Flying leads) Connector
1 2
Non-locking Locking
KA KD BA
Square connector Square connectorwith light Flying leads
900 82 6300
* Other options available, see page 353.
6500
End plate kit required (Port size 1/4” NPTF) : M-45008-01. Options (with gauge port) : Single operator : replace L by M Double operator : replace N by P.
6600
REGULATOR AND F.C. OPTIONS
45A-XXK-D XXX-XXX
55 56 57 58 59
1300 (“K” option is for Adj. knob and F.C.)
800
Replace with “F” for slotted stem and F.C. Replace with “H” for locking slotted stem and F.C.
ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A 77
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 14
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series 45 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)
Leak rate :
100 cm3/min
Coil :
General purpose class A, continuous duty, encapsulated
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W Response times :
24 VDC (5.4 W)
Energize : 6 ms
De-energize : 2 ms
120/60
Energize : 3-8 ms
De-energize : 2-7 ms
Spare parts :
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Pressure regulator with flow controls : 45A-00N (Slotted Stem), 45A-00P (Locking Slotted Stem), 45A-00S(Adj. Knob). • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
Options :
• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.
DIMENSIONS
Dimensions shown are metric (mm) 1/8” NPTF CYLINDER PORTS
# 10-32 UNF CYLINDER PORTS
10,0
20,5
62,5
17,5
B
15,5
51,0
B
IN A
ADJ. LOCKING KNOB
8,0
8,0
8,5
OPTIONAL 1/8” NPTF BOTTOM INLET
A
4,0
LOCK
4,0
20,10 ±0,1
33,0 1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS
Ø 5,3 MTG. SLOT 9,0 ± 0,2 OPTIONAL ISOLATOR 2,5
IN
29,0
13,5 EX
Ø 15,5
9,75 13,7 13,5
18,9 5,2
OPTIONAL GAGE PORT
17,3
19,0
102,1 REGULATOR W/SLOTTED STEM
14,0 6,0 LOCKING STEM 13,4 LOCKING KNOB
71,1
78
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 15
I n t r i n s i c a l l y
S a f e
V a l v e s
Series 35-45 BODY OPTIONS
HOW TO ORDER
SOLENOID OPTIONS
35A - X X X - (DXXX - XXX) - FM PORT SIZE
BODY TYPE
Inline A Individual Inline D Indiv. Inline w/2 Manifold Mount Ports Manifold E Manifold Body (N.C. Only) G Manifold Body w/Gage Port (N.C. Only)
VALVE FUNCTION/MANIFOLD TYPE
Manifold Body Only #10-32 UNF (Inline Only) M5 (Inline Only)
O B D
Manifold Body Only 3 way N.C. Only (Inline)
O B
Note : there is no manifold base for the 35 series. The manifold valve can only mount to a circuit bar, see note below
BODY OPTIONS
SOLENOID OPTIONS
45A - X X X - (DXXX - XXX) - FM BODY TYPE
Inline A 4 Port Body B 5 Port Body D 4 Port Body “O” Ring Mount -All Bottom Ports E 5 Port Body “O” Ring Mount -3 Bottom Ports Inlet and Cylinders F 4 Port Body “O” Ring Mount-Bottom Cylinder Ports Only Base Mount O For Base Only - No Valve L Base Mount Body M Base Mount Body with Gage Port
PORT SIZE
O A B C D F G H J K
VALVE FUNCTION/MANIFOLD TYPE
Manifold Body Only 1/8" NPT #10-32 UNF 1/8" BSPPL M5 (Metric) #10-32 UNF Bottom Ports M5 Bottom Ports “O” Ring Mount Ports 1/8" NPT Bottom Ports 1/8" BSPPL Bottom Ports
Inline 1 No Flow Controls Bases - Regulators O Valve Only - No Base A Individual Base C Manifold Base E Manifold w/Regulator w/Slotted Stem G Manifold w/Regulator w/Locking Slotted Stem J Manifold w/Regulator w/Locking Knob
MANIFOLD MOUNT ACCESSORIES
M-45008-01 16455 19753 N-45008 N-45009 N-45010 N-45015 N-45016 N-45017
End Plate Kit Pressure Seal Between Manifold Tie Rod Isolator Kit - Inlet and Exhaust Isolator Kit - Inlet only Isolator Kit - Exhaust only End Cover Plate - Plain End Cover Plate w/Flow Controls Flow Control Needle Assembly
SOLENOID OPTIONS
D - X X X - X X X - FM VOLTAGE
FR FS
12VDC (0.6 W) 24VDC (0.6 W)
MANUAL OPERATOR
LEAD LENGTH
A B C D E J*
18" Leads 24" Leads 36" Leads 48" Leads 72" Leads 6" Leads
0 1 2 3 4
No operator Non-locking Recessed Locking Recessed Non-locking Extended Locking Extended
*Use “J” for external plug-in connectors NOTE : For valves mounted to a circuit bar reference MAC circuit bar Catalog for ordering info. For the 35 series circuit bar, use MOD FM01 after circuit bar part number.
334
ELECTRICAL CONNECTION
BA Grommet CA Conduit 1/2" NPS† CM Metal Conduit 1/2" NPS† CN Metal Conduit w/grd. 1/2" NPS† External Plug-in FM Plug-in (For ECD & ECE Bar) JB Rectangular Plug-in† JM Rectangular Male only† KA Mini Plug-in KJ Mini Plug-in Male only TA Dual Tabs (.110) Plain TJ Dual Tabs (.110) Plain † Available on individual valves and circuit bars.
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 16
O p t i o n
OPTIONS
Codification table for voltages / Wire length / Manual operators / Electrical connections
VALVE CODE ®
- D XX X - X XX 1 2 3 4 OPTIONS AVAILABLE FOR
- Solenoid valves 35, 45 and 82 Series
353
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
s
Page 17
OPTIONS
1. VOLTAGE
- D XX X - X XX
VOLTAGE
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
AD
24/60
AE
200/60
AF
240/50
AG
100/50, 100/60, 110/60
DA
24 VDC (5.4 W)
DB
12 VDC (5.4 W)
DC
12 VDC (7.5 W)
DD
24 VDC (7.3 W)
DE
12 VDC (12.7 W) - CLSFonly
DF
24 VDC (12.7 W) - CLSF only
DK
110 VDC (4.7 W)
DL
64 VDC (6 W)
DM
36 VDC (5.3 W)
DN
6 VDC (6 W)
DP
48 VDC (5.8 W)
DU
24 VDC (6 W)
EA
12 VDC (6 W)
FA
12 VDC (1.8 W)
FB
24 VDC (1.8 W)
FE
12 VDC (2.4 W)
FF
24 VDC (2.4 W)
2. WIRE LENGTH
- D XX X - X XX
WIRE LENGTH
A
18”
B
24”
C
36”
D
48”
E
72”
F
96”
J
For external plug-in connector (“J”, “K” & “T” type electrical connection)
P
For plug-in valves (82 Series only)
354
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 18
O p t i o n
OPTIONS
3. MANUAL OPERATOR
- D XX X - X XX
MANUAL OPERATOR
0
No operator
1
Non-locking recessed
2
Locking recessed
3
Non-locking extended
4
Locking extended
4. ELECTRICAL CONNECTION
- D XX X - X XX
ELECTRICAL CONNECTION
BA
Flying leads
BK
BA with protection diode
BL
BA with protection varistor (M.O.V.)
** CA
1/2" NPS conduit
** CM
1/2" NPS metal conduit
** CN
1/2" NPS metal conduit w/ground
JB
Rectangular connector
JD
Rectangular connector with light
JM
Rectangular connector, male only
KA
Square connector
KB
Square connector with protection diode
KC
Square connector with protection varistor (M.O.V.)
KD
Square connector with light
KE
Square connector with light and protection diode
KF
Square connector with light and protection varistor (M.O.V.)
KG
Square connector with LED light & diode
KJ
Square connector (male only)
KK
Square connector with protection diode (male only)
KL
Square connector with protection varistor (male only) (M.O.V.)
*** MA
Electrical common conduit
TA
Dual tabs
TB
TA with protection diode
TD
TA with light
TE
TA with light and protection diode
TJ
Dual tabs (male only)
TK
TJ with protection diode
TM
TJ with light
TN
TJ with light and protection diode
DA*
Plug-in connector
DK*
DA with protection diode
DL*
DA with protection varistor (M.O.V.)
*
To be used with 82 Series only
**
Inline valves only for 35 & 45 series. No restrictions for 82 series.
*** Stacking valves only for 35 & 45 series. Conduit end plate kit required, one per stack. 35 series : M-35002-01 45 series : M-45005-01
355
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
s