For the MAC Valves 45 Series

Page 10

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series 45 TECHNICAL DATA

Fluid :

Compressed air, vacuum, inert gases

Pressure range :

Vacuum to 120 PSI

Lubrication :

Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)

Filtration :

40 µ

Temperature range :

0°F to 120°F (-18°C to 50°C)

Flow (at 6 bar, ΔP=1bar) :

1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)

Leak rate :

100 cm3/min

Coil :

General purpose class A, continuous duty, encapsulated

Voltage range :

-15% to +10% of nominal voltage

Protection :

Consult factory

Power :

∼ Inrush : 10.9 VA

Holding : 7.7 VA

= 1.8 to 12.7 W Response times :

24 VDC (5.4 W)

Energize : 6 ms

De-energize : 2 ms

120/60

Energize : 3-8 ms

De-energize : 2-7 ms

Spare parts :

• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Side cover plate with flow controls : N-45016. • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.

Options :

• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.

DIMENSIONS

Dimensions shown are metric (mm)

1/8” NPTF CYLINDER PORTS

# 10-32 UNF PORTS CYLINDER

10,0

20,5

OPTIONAL 1/8” NPTF BOTTOM INLET 62,5

17,5

B

51,0

B

IN A

A

8,0

8,5

8,0

4,0

4,0

20,10 ±0,1 Ø 5,3 MTG. SLOT

33

9,0 OPTIONAL ISOLATOR

1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS 2,5

IN

9,75 29,0

13,5 EX

18,9 13,7

5,2 71,1

17,3

74

19,0

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 11

Direct solenoid and solenoid pilot operated valves

Series 45 Function

Port size

Flow (Max)

Manifold mounting

4/2

# 10-32 - 1/8”

0.11 Cv sub-base with pressure regulators

Series

OPERATIONAL BENEFITS

35

1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.

100 200

HOW TO ORDER

Single operator

Port size

A

A

B

EXH

Double operator (Minimum DC wattage 5,4W) A B

A

B

EXH

IN

55 56 57 58 59

B

IN

Valve less base

45A-L00-DXXX-XXX

45A-N00-DXXX-XXX

1/8” NPTF base

45A-LAJ-DXXX-XXX

45A-NAJ-DXXX-XXX

# 10-32 UNF base

45A-LBJ-DXXX-XXX

45A-NBJ-DXXX-XXX

SOLENOID OPERATOR ®

D XX X- X XX *

45

700

XX

Voltage

X

Wire length

X

Manual operator

XX

Electrical connection

AA AB AC FB DA DF

120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)

A J

18” (Flying leads) Connector

1 2

Non-locking Locking

KA KD BA

Square connector Square connector with light Flying leads

900 82 6300

* Other options available, see page 353.

6500

End plate kit required (Port size 1/4” NPTF) : M-45008-01. Options (with gauge port) : Single operator : replace L by M. Double operator : replace N by P.

6600

REGULATOR OPTIONS

45A-XXJ-D XXX-XXX

1300

(“J” is for Adj. knob)

Replace with “E” for slotted stem Replace with “G” for locking slotted stem

800 ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A 75

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 12

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series 45 TECHNICAL DATA

Fluid :

Compressed air, vacuum, inert gases

Pressure range :

Vacuum to 120 PSI

Lubrication :

Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)

Filtration :

40 µ

Temperature range :

0°F to 120°F (-18°C to 50°C)

Flow (at 6 bar, ΔP=1bar) :

1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)

Leak rate :

100 cm3/min

Coil :

General purpose class A, continuous duty, encapsulated

Voltage range :

-15% to +10% of nominal voltage

Protection :

Consult factory

Power :

∼ Inrush : 10.9 VA

Holding : 7.7 VA

= 1.8 to 12.7 W Response times :

24 VDC (5.4 W)

Energize : 6 ms

De-energize : 2 ms

120/60

Energize : 3-8 ms

De-energize : 2-7 ms

Spare parts :

• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Pressure regulator : 45A-00R (Adj. Knob), 45A-00L (Slotted Stem), 45A-00M (Locking Slotted Stem). • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.

Options :

• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow mod. • Bottom inlet : specify Mod. 0210.

DIMENSIONS

Dimensions shown are metric (mm) 1/8” NPTF CYLINDER PORTS OPTIONAL 1/8” NPTF BOTTOM 62,5 INLET

# 10-32 UNF PORTS CYLINDER

17,5

B

10,0

20,5

51,0

B

IN A

A

8,0

8,5

8,0

4,0

4,0

20,10 ±0,1 33,0

Ø 5,3 MTG. SLOT 9,0 ± 0,2 1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS

OPTIONAL ISOLATOR 2,5

IN

9,75

13,5

13,5

29,0

EX

14,0

13,7

OPTIONAL GAGE PORT

18,9

17,3

5,2

19,0

102,1 REGULATOR W/ SLOTTED STEM

71,1

76

Ø 15,5

13,4 LOCKING KNOB

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 13

Direct solenoid and solenoid pilot operated valves

Series 45 Function

Port size

4/2

# 10-32 - 1/8”

Flow (Max)

Manifold mounting

0.11 Cv sub-base with pressure regulators and flow controls

Series

OPERATIONAL BENEFITS

35

1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service.

100 200

HOW TO ORDER

Single operator

Port size

A

A

B

EXH

Double operator (Minimum DC wattage 5,4W)

B

A B

A

EXH

IN

B

IN

Valve less base

45A-L00-DXXX-XXX

45A-N00-DXXX-XXX

1/8” NPTF base

45A-LAK-DXXX-XXX

45A-NAK-DXXX-XXX

# 10-32 UNF base

45A-LBK-DXXX-XXX

45A-NBK-DXXX-XXX

SOLENOID OPERATOR ®

D XX X- X XX *

45

700

XX

Voltage

X

Wire length

X

Manual operator

XX

Electrical connection

AA AB AC FB DA DF

120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (1.8 W) 24 VDC (5.4 W) 24 VDC (12.7 W)

A J

18” (Flying leads) Connector

1 2

Non-locking Locking

KA KD BA

Square connector Square connectorwith light Flying leads

900 82 6300

* Other options available, see page 353.

6500

End plate kit required (Port size 1/4” NPTF) : M-45008-01. Options (with gauge port) : Single operator : replace L by M Double operator : replace N by P.

6600

REGULATOR AND F.C. OPTIONS

45A-XXK-D XXX-XXX

55 56 57 58 59

1300 (“K” option is for Adj. knob and F.C.)

800

Replace with “F” for slotted stem and F.C. Replace with “H” for locking slotted stem and F.C.

ISO 1 ISO 2 ISO 3 MAC125A MAC250A MAC500A 77

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 14

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series 45 TECHNICAL DATA

Fluid :

Compressed air, vacuum, inert gases

Pressure range :

Vacuum to 120 PSI

Lubrication :

Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)

Filtration :

40 µ

Temperature range :

0°F to 120°F (-18°C to 50°C)

Flow (at 6 bar, ΔP=1bar) :

1.8 W : (0.09 Cv), 5.4 W : (0.11 Cv)

Leak rate :

100 cm3/min

Coil :

General purpose class A, continuous duty, encapsulated

Voltage range :

-15% to +10% of nominal voltage

Protection :

Consult factory

Power :

∼ Inrush : 10.9 VA

Holding : 7.7 VA

= 1.8 to 12.7 W Response times :

24 VDC (5.4 W)

Energize : 6 ms

De-energize : 2 ms

120/60

Energize : 3-8 ms

De-energize : 2-7 ms

Spare parts :

• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Pressure regulator with flow controls : 45A-00N (Slotted Stem), 45A-00P (Locking Slotted Stem), 45A-00S(Adj. Knob). • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.

Options :

• BSPP threads. • High flow up to 0.18 Cv, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.

DIMENSIONS

Dimensions shown are metric (mm) 1/8” NPTF CYLINDER PORTS

# 10-32 UNF CYLINDER PORTS

10,0

20,5

62,5

17,5

B

15,5

51,0

B

IN A

ADJ. LOCKING KNOB

8,0

8,0

8,5

OPTIONAL 1/8” NPTF BOTTOM INLET

A

4,0

LOCK

4,0

20,10 ±0,1

33,0 1/4” NPTF INLET & EXHAUST PORTS BOTH ENDS

Ø 5,3 MTG. SLOT 9,0 ± 0,2 OPTIONAL ISOLATOR 2,5

IN

29,0

13,5 EX

Ø 15,5

9,75 13,7 13,5

18,9 5,2

OPTIONAL GAGE PORT

17,3

19,0

102,1 REGULATOR W/SLOTTED STEM

14,0 6,0 LOCKING STEM 13,4 LOCKING KNOB

71,1

78

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 15

I n t r i n s i c a l l y

S a f e

V a l v e s

Series 35-45 BODY OPTIONS

HOW TO ORDER

SOLENOID OPTIONS

35A - X X X - (DXXX - XXX) - FM PORT SIZE

BODY TYPE

Inline A Individual Inline D Indiv. Inline w/2 Manifold Mount Ports Manifold E Manifold Body (N.C. Only) G Manifold Body w/Gage Port (N.C. Only)

VALVE FUNCTION/MANIFOLD TYPE

Manifold Body Only #10-32 UNF (Inline Only) M5 (Inline Only)

O B D

Manifold Body Only 3 way N.C. Only (Inline)

O B

Note : there is no manifold base for the 35 series. The manifold valve can only mount to a circuit bar, see note below

BODY OPTIONS

SOLENOID OPTIONS

45A - X X X - (DXXX - XXX) - FM BODY TYPE

Inline A 4 Port Body B 5 Port Body D 4 Port Body “O” Ring Mount -All Bottom Ports E 5 Port Body “O” Ring Mount -3 Bottom Ports Inlet and Cylinders F 4 Port Body “O” Ring Mount-Bottom Cylinder Ports Only Base Mount O For Base Only - No Valve L Base Mount Body M Base Mount Body with Gage Port

PORT SIZE

O A B C D F G H J K

VALVE FUNCTION/MANIFOLD TYPE

Manifold Body Only 1/8" NPT #10-32 UNF 1/8" BSPPL M5 (Metric) #10-32 UNF Bottom Ports M5 Bottom Ports “O” Ring Mount Ports 1/8" NPT Bottom Ports 1/8" BSPPL Bottom Ports

Inline 1 No Flow Controls Bases - Regulators O Valve Only - No Base A Individual Base C Manifold Base E Manifold w/Regulator w/Slotted Stem G Manifold w/Regulator w/Locking Slotted Stem J Manifold w/Regulator w/Locking Knob

MANIFOLD MOUNT ACCESSORIES

M-45008-01 16455 19753 N-45008 N-45009 N-45010 N-45015 N-45016 N-45017

End Plate Kit Pressure Seal Between Manifold Tie Rod Isolator Kit - Inlet and Exhaust Isolator Kit - Inlet only Isolator Kit - Exhaust only End Cover Plate - Plain End Cover Plate w/Flow Controls Flow Control Needle Assembly

SOLENOID OPTIONS

D - X X X - X X X - FM VOLTAGE

FR FS

12VDC (0.6 W) 24VDC (0.6 W)

MANUAL OPERATOR

LEAD LENGTH

A B C D E J*

18" Leads 24" Leads 36" Leads 48" Leads 72" Leads 6" Leads

0 1 2 3 4

No operator Non-locking Recessed Locking Recessed Non-locking Extended Locking Extended

*Use “J” for external plug-in connectors NOTE : For valves mounted to a circuit bar reference MAC circuit bar Catalog for ordering info. For the 35 series circuit bar, use MOD FM01 after circuit bar part number.

334

ELECTRICAL CONNECTION

BA Grommet CA Conduit 1/2" NPS† CM Metal Conduit 1/2" NPS† CN Metal Conduit w/grd. 1/2" NPS† External Plug-in FM Plug-in (For ECD & ECE Bar) JB Rectangular Plug-in† JM Rectangular Male only† KA Mini Plug-in KJ Mini Plug-in Male only TA Dual Tabs (.110) Plain TJ Dual Tabs (.110) Plain † Available on individual valves and circuit bars.

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 16

O p t i o n

OPTIONS

Codification table for voltages / Wire length / Manual operators / Electrical connections

VALVE CODE ®

- D XX X - X XX 1 2 3 4 OPTIONS AVAILABLE FOR

- Solenoid valves 35, 45 and 82 Series

353

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

s

Page 17

OPTIONS

1. VOLTAGE

- D XX X - X XX

VOLTAGE

AA

120/60, 110/50

AB

240/60, 220/50

AC

24/60, 24/50

AD

24/60

AE

200/60

AF

240/50

AG

100/50, 100/60, 110/60

DA

24 VDC (5.4 W)

DB

12 VDC (5.4 W)

DC

12 VDC (7.5 W)

DD

24 VDC (7.3 W)

DE

12 VDC (12.7 W) - CLSFonly

DF

24 VDC (12.7 W) - CLSF only

DK

110 VDC (4.7 W)

DL

64 VDC (6 W)

DM

36 VDC (5.3 W)

DN

6 VDC (6 W)

DP

48 VDC (5.8 W)

DU

24 VDC (6 W)

EA

12 VDC (6 W)

FA

12 VDC (1.8 W)

FB

24 VDC (1.8 W)

FE

12 VDC (2.4 W)

FF

24 VDC (2.4 W)

2. WIRE LENGTH

- D XX X - X XX

WIRE LENGTH

A

18”

B

24”

C

36”

D

48”

E

72”

F

96”

J

For external plug-in connector (“J”, “K” & “T” type electrical connection)

P

For plug-in valves (82 Series only)

354

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 18

O p t i o n

OPTIONS

3. MANUAL OPERATOR

- D XX X - X XX

MANUAL OPERATOR

0

No operator

1

Non-locking recessed

2

Locking recessed

3

Non-locking extended

4

Locking extended

4. ELECTRICAL CONNECTION

- D XX X - X XX

ELECTRICAL CONNECTION

BA

Flying leads

BK

BA with protection diode

BL

BA with protection varistor (M.O.V.)

** CA

1/2" NPS conduit

** CM

1/2" NPS metal conduit

** CN

1/2" NPS metal conduit w/ground

JB

Rectangular connector

JD

Rectangular connector with light

JM

Rectangular connector, male only

KA

Square connector

KB

Square connector with protection diode

KC

Square connector with protection varistor (M.O.V.)

KD

Square connector with light

KE

Square connector with light and protection diode

KF

Square connector with light and protection varistor (M.O.V.)

KG

Square connector with LED light & diode

KJ

Square connector (male only)

KK

Square connector with protection diode (male only)

KL

Square connector with protection varistor (male only) (M.O.V.)

*** MA

Electrical common conduit

TA

Dual tabs

TB

TA with protection diode

TD

TA with light

TE

TA with light and protection diode

TJ

Dual tabs (male only)

TK

TJ with protection diode

TM

TJ with light

TN

TJ with light and protection diode

DA*

Plug-in connector

DK*

DA with protection diode

DL*

DA with protection varistor (M.O.V.)

*

To be used with 82 Series only

**

Inline valves only for 35 & 45 series. No restrictions for 82 series.

*** Stacking valves only for 35 & 45 series. Conduit end plate kit required, one per stack. 35 series : M-35002-01 45 series : M-45005-01

355

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

s