The text of a spec sheet · part 1 of 3
Direct solenoid and solenoid pilot operated valves, Series ISO 3, pages 1 to 10
Pages 1 to 10 of 29
The original document is the PDF (950 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the MAC Valves MV-A2B-A141-PM-111DA and MAC Valves MV-A2B-A341-PM-111DA
Page 1
Direct solenoid and solenoid pilot operated valves
Series ISO 3 Individual mounting Valve only – No base non “plug-in” Conform to ISO 5599/1
Series
Valve only – No base “plug-in” Conform to ISO 5599/2
33 34
Manifold mounting Valve only – No base non “plug-in” Conform to ISO 5599/1
Valve only – No base “plug-in” Conform to ISO 5599/2
36 32 Manual operator
Balanced 4-way poppet Bonded spool
Internal pilot supply Large spool diameter External pilot supply
37 38 52 67 69 44 46 42
Air return
47 48P External pilot supply
3
2
1
4
5
48 400 92 SERIES FEATURES • Plug-in (5599/2) and non plug-in (5599/1) models. • 2-position, single or double operator. (Solenoid or Remote Air) • 3-position, double solenoid, open center, closed center, and pressure center. • Extended or recessed manual operators. • Single pressure and dual pressure. • Individual base or add-a-unit manifold base. • Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves.
191
93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 2
Direct solenoid and solenoid pilot operated valves
Series ISO 3 Function
Port size
5/2, 5/3
1/2” - 3/4”
Flow (Max)
Individual/Manifold mounting
6.1 Cv
Valve only – No base “non plug-in” Conform to ISO 5599/1
Series
OPERATIONAL BENEFITS
1. Unique patented Macsolenoid® for fastest possible response times and virtually burnout proof AC solenoid operation. 2. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package.
33 34
6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt.
36 32 37 38 52 67 69 44
HOW TO ORDER
SINGLE PRESSURE MODELS Pilot air
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
4 2
1 3
5
1
5/3 Closed center 14
12
4 2
5
3
1
5/3 Open center 12
14
4
3
5
2
1
12
46
3
Internal
MV-B3A-AAAA-DM-DXXX-XXX
MV-B3A-ABAA-DM-DXXX-XXX
MV-B3A-AEAA-DM-DXXX-XXX
MV-B3A-AFAA-DM-DXXX-XXX
External "12" end
MV-B3A-AAAB-DM-DXXX-XXX
MV-B3A-ABAB-DM-DXXX-XXX
MV-B3A-AEAB-DM-DXXX-XXX
MV-B3A-AFAB-DM-DXXX-XXX
42
5/3 Pressure center
47 48P
DUAL PRESSURE MODELS Pilot air
5/2 Single operator
5/2 Double operator
14
14
4 2
5
Internal pilot From port #3
12
1 3
4 2
5
MV-B3A-ACAD-DM-DXXX-XXX
1
14
12
12
5
3
MV-B3A-ADAD-DM-DXXX-XXX
1
3
Internal pilot From port #5
MV-B3A-ACAE-DM-DXXX-XXX
MV-B3A-ADAE-DM-DXXX-XXX
MV-B3A-AGAE-DM-DXXX-XXX
External pilot From "12" end
MV-B3A-ACAB-DM-DXXX-XXX
MV-B3A-ADAB-DM-DXXX-XXX
MV-B3A-AGAB-DM-DXXX-XXX
XX
Voltage
X
Lead wire length
X
Manual operator
XX
Electrical connection
JA JB JC FB DA DF
110/50, 120/60 220/50, 240/60 24/50, 24/60 24 VDC (1.8W) 24 VDC (5.4W) 24 VDC (12.7W)
A B J
18” (Flying leads) 24” (Flying leads) Connector
1 2
Non-locking recessed Locking recessed
KA KD JB JD BA
Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads
* Other options available, see page 309. Note: ISO series, valve and base are ordered separately, see page 239 for base code.
OPTIONS
Valve function :
400 92
DM-D XXX-XXX *
SOLENOID OPERATOR ®
48
MV-B3A-AGAD-DM-DXXX-XXX
93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3
Spool return :
MV-B3A-AXXX-XX-DXXX-XXX
MV-B3A-AXAX-XX-DXXX-XXX
J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only)
A Standard return B Memory spring return
Pilot style : MV-B3A-AXXX-DM-DXXX-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-32)
193
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 3
100%
WARRANTY
18
OF PRODUCTION TESTED
100%
MONTHS
Series ISO 3 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Internal pilot: 20 to 120 PSI External pilot : vacuum to 120 PSI
Pilot pressure :
Single/double operator : 20 to 120 PSI, 3 positions : 30 to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to +50°C)
Flow :
1/2": (5.4 Cv) – 3/4": (6.1 Cv)
Coil :
Class A continuous duty, #22 AWG leads
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
~ Inrush 7.6 VA
Holding: 4.8 VA
= 12.7 to 1.0 W Response times :
Energize : 16.2 ms
(5.4 W coil)
De-energize : 13.6 ms
Options :
• Sandwich regulator, see ‚Regulators‘ section
Spare parts :
• Pilot valve: DMB-Dxxx-xxx • Valve to base pressure seal: 16614 • Valve mounting screws (x4): 35451
DIMENSIONS
Dimensions shown are metric (mm)
Individual base
Manifold base
DOUBLE SOLENOID W/ EXTENDED OVERRIDE
190.4 SINGLE SOLENOID W/ EXTENDED OVERRIDE
26.5
175.0
12
P
160.0
77,9 50.0
23.0 2
4
19.0
40.0
WATTS
VAC TO 120 PSI
MODEL
ELECTRICAL
WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z.
MODIF.
139.9
138.5
5 44.5
4
1
160.8
3 2 27.0
23.5
33.0
65.8 1
48.8 32.8
29.0
63.3
3
47.0 27.8
5
COND
57.5
17.3 50.2
78.0
96.0
98.5
140.0
127.0
162.0 175.2
126.0
8.3 DIA. THRU 4 MTG. HOLES
77.0
232.1
28.0 18.5
5
66.5
188.9
3
1
8.25 DIA. THRU 2 MTG HOLES
99.9 25.8
54.5
33.4
64.0
4
136.4
24.5
2
7.5
48.0
2
78.0
19.0
39.0 59.0
31.0
5 1
3 4
OPTIONAL BTM PORTS
27.0
7.0
140.0
59.5
208.0
94.5
194
55.7
9.0
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 4
Direct solenoid and solenoid pilot operated valves
Series ISO 3 Function
Port size
5/2, 5/3
Flow (Max)
1/2” - 3/4”
Individual/Manifold mounting
Series
Valve only – No base “plug-in” Conform to ISO 5599/2
6.1 Cv
OPERATIONAL BENEFITS
1. Unique patented Macsolenoid® for fastest possible response times and virtually burnout proof AC solenoid operation. 2. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package.
33 34
6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt.
36 32 37 38 52 67 69 44
HOW TO ORDER
SINGLE PRESSURE MODELS Pilot air
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
4 2
1 3
5
1
5/3 Closed center 14
12
4 2
5
3
1
5/3 Open center 12
14
4
3
5
2
1
12
46
3
Internal
MV-P3A-AAAA-DM-DXXP-XXX
MV-P3A-ABAA-DM-DXXP-XXX
MV-P3A-AEAA-DM-DXXP-XXX
MV-P3A-AFAA-DM-DXXP-XXX
External "12" end
MV-P3A-AAAB-DM-DXXP-XXX
MV-P3A-ABAB-DM-DXXP-XXX
MV-P3A-AEAB-DM-DXXP-XXX
MV-P3A-AFAB-DM-DXXP-XXX
42
5/3 Pressure center
47 48P
DUAL PRESSURE MODELS Pilot air
5/2 Single operator
5/2 Double operator
14
14
4 2
5
Internal pilot From port #3
12
4 2
1 3
5
MV-P3A-ACAD-DM-DXXP-XXX
1
12
14
12
5
3
MV-P3A-ADAD-DM-DXXP-XXX
1
3
Internal pilot From port #5
MV-P3A-ACAE-DM-DXXP-XXX
MV-P3A-ADAE-DM-DXXP-XXX
MV-P3A-AGAE-DM-DXXP-XXX
External pilot From "12" end
MV-P3A-ACAB-DM-DXXP-XXX
MV-P3A-ADAB-DM-DXXP-XXX
MV-P3A-AGAB-DM-DXXP-XXX
400 92
DM-D XX P-XXX *
SOLENOID OPERATOR ®
48
MV-P3A-AGAD-DM-DXXP-XXX
XX
Voltage
X
Manual operator
XX
Electrical connection
JA JB JC FB DA DF
110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/50, 24/60 (2.9W) 24 VDC (1.8W) 24 VDC (5.4W) 24 VDC (12.7W)
1 2
Non-locking recessed Locking recessed
DM DN DP DG
Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground
* Other options available, see page 309. Note: - ISO series, valve and base are ordered separately, see page 241 for base codes. - Ground wire required for 30 volts or higher.
93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3
OPTIONS
Spool return :
Valve function : MV-P3A-AXXX-XX-DXXP-XXX
MV-P3A-AXAX-XX-DXXP-XXX
J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only)
A Standard return B Memory spring return D Standard return with light E Memory spring return with light
Pilot style : MV-P3A-AXXX-DM-DXXP-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-32)
195
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 5
100%
WARRANTY
18
OF PRODUCTION TESTED
100%
MONTHS
Series ISO 3 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Internal pilot: 20 to 120 PSI External pilot : vacuum to 120 PSI
Pilot pressure :
Single/double operator : 20 to 120 PSI, 3 positions : 30 to 120 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to +50°C)
Flow :
1/2": (5.4 Cv) – 3/4": (6.1 Cv)
Coil :
Class A continuous duty, #22 AWG leads
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
~ Inrush 7.6 VA
Holding: 4.8 VA
= 12.7 to 1.0 W Response times :
Energize : 16.2 ms
(5.4 W coil)
De-energize : 13.6 ms
Options :
• Sandwich regulator, see ‚Regulators‘ section
Spare parts :
• Pilot valve: DMB-DxxP-xxx • Valve to base pressure seal: 16614 • Valve mounting screws (x4): 35451
DIMENSIONS
Dimensions shown are metric (mm)
Individual base
Manifold base
WATTS
VAC TO 120 PSI
MODEL
ELECTRICAL
WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z.
MODIF.
26.5 12
P
77,9 50.0
23.0 2
4
139.4
19.0
40.0
WATTS
VAC TO 120 PSI
28.5
MODEL
23.5
ELECTRICAL
29.0
WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z.
MODIF.
139.9
31.0 160.8
48.5 69.0 89.5
65.8
106.5
32.8
3
47.0 27.8
5
COND
193.0 8.25 DIA THRU 2 MTG HOLES
63.3
1
48.8 142.0
48.0
17.3 50.2
166.5
96.0 107.0
140.0 162.0
69.0
175.2
31.0
188.9 232.1
5
1
3
24.5
8.5
8.25 DIA. THRU 2 MTG HOLES
54.5
62.0 4
136.4 99.9
79.0
25.8
2
14
2
69.5
12
33.4 78.0
158.0
27.0
39.0 59.0
31.0
5 1
3 4
24.0
19.0
51.5 208.0
86.5
9.0 55.7
114.0
196
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 6
R e m o t e a i r v a l v e s
Series ISO 3 Function
Port size
Flow (Max)
Individual/Manifold mounting
5/2 – 5/3
1/2" – 3/4"
6.2 Cv
Valve only – no base
Series
OPERATIONAL BENEFITS
400
1. Balanced spool, immune to variations of pressure. 2. Powerful return forces thanks to the combination of mechanical and air springs. 3. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life.
67 69 ISO 2 ISO 3
HOW TO ORDER
SINGLE PRESSURE MODELS Air spring
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
1 3
4 2
5
Internal
MV-R3A-BACF
External
MV-R3A-BACG
5/3 Closed center 14
12
4 2
5
1 3
MV-R3A-BBAK
1
5/3 Open center 12
14
4 2
5
3
MV-R3A-BEAK
1
12
3
MV-R3A-BFAK
DUAL PRESSURE MODELS Air spring
5/2 Single operator
5/2 Double operator
5/3 Pressure center
14
14
14
4 2
5
Internal port #3
12
1 3
4 2
5
1
12
3
4
5
2
1
12
3
MV-R3A-BCCH
Internal port #5
MV-R3A-BCCJ
External
MV-R3A-BCCG
MV-R3A-BDAK
MV-R3A-BGAK
Note: ISO series, valve and base are ordered separately, see page 239 for base code.
221
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 7
R e m o t e a i r v a l v e s
Series ISO 3 Function
Port size
Flow (Max)
5/2 - 5/3
1/2" - 3/4"
6.3 Cv
Series
Individual mounting valve only operational benefits
1100
1. spool, immune to variations of pressure. 2. stroke with high flow. 3. piston (booster) provides maximum shifting forces. 4. return thanks to the combination of mechanical and air springs. 5. spool with minimum friction, shifting in a glass-like finished bore. 6. effect eliminates sticking. 7. leakage rate.
55 56 57 58 59 how to order
Single pressure valves Air spring
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
1 3
4 2
5
5/3 Closed center 14
12
4 2
5
1 3
1
5/3 Open center 14
12
4 2
5
3
1
12
3
900
Internal
MV-A3B-B111
-----
-----
-----
External
MV-A3B-B121
MV-A3B-B221
MV-A3B-B322
MV-A3B-B321
82
Dual pressure valves Air spring
700
5/2 Single operator
5/2 Double operator
5/3 Pressure center
14
14
14
4 2
5
12
4 2
5
1 3
1
12
3
4
5
2
1
12
3
Internal port 3
MV-A3B-B131
-----
-----
Internal port 5
MV-A3B-B135
-----
-----
External
MV-A3B-B141
MV-A3B-B241
MV-A3B-B341
Note : ISO valves are delivered w/o base. See page 281 for base code.
6300 6500 6600 2700 1800 ISO 1 ISO 2 ISO 3
265
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 8
100% OF PRODUCTION TESTED
100%
18 WARRANTY
MONTHS
Series ISO 3 technical data
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 150 PSI
Air signal pressure :
Single operator and 3 positions : 25 to 150 PSI ≥ main valve pressure
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ∆P=1bar) :
1/2" - 3/4” : (6.3 Cv)
Leak rate :
200 cm3/min
Spare parts :
• Remote air operator : R-A3004. • Pressure seal between valve and base : 16436. • Mounting screw body to base (x4) : 35416.
Double operator : 10 to 150 PSI
Dimensions shown are metric (mm)
dimensions
12
46,0
2
33,0 27,0
124,4
14
4 22,0
43,5
55,0
70,0 35,0 17,5
20,5 20,5 49,0
1/8” REMOTE PILOT
Ø 8,3 -4 MTG. HOLES
140,0
45,0
45,0
15,0
49,0 168,0
32,0
2
39,5
4
64,0
79,0 21,0
1
3 15,0
49,0
49,0 78,0 156,0
266
5
OPTIONAL BOTTOM PORTS
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 9
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series ISO 3 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 150 PSI
Air signal pressure :
Single/double operator: 20 to 150 PSI 3 position: 30 to 150 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow :
1/2" : (5.4 Cv) - 3/4" : (6.2 Cv)
Spare parts :
• Valve to base pressure seal: 16614 • Valve mounting screws (x4): 35451
DIMENSIONS
Dimensions shown are metric (mm)
WIXOM,MI USA LIEGE,BELGIUM AUCKLAND,N.J. MODIF.
ISO 5599/2
63.4 MODEL
VAC TO 150 PSI
160.0
56.8
222
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 10
B a s e s a c c o r d i n g t o
I S O
5 5 9 9 / 1
Series ISO 3 Series Non plug-in base / manifold
ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 HOW TO ORDER
INDIVIDUAL BASE Port size
Side ports
Bottom ports
Bottom cylinder ports 2 and 4.
Bottom inlet port 1
1/2” NPTF
MB-A3B-221
MB-A3B-223
MB-A3B-222
MB-A3B-224
3/4” NPTF
MB-A3B-231
MB-A3B-233
MB-A3B-232
MB-A3B-234
Side ports
Bottom ports
Bottom cylinder ports 2 and 4.
Bottom inlet port 1
1/2” NPTF
MM-B3A-221-A
MM-B3A-223-A
MM-B3A-222-A
MM-B3A-224-A
3/4” NPTF
MM-B3A-231-A
MM-B3A-233-A
MM-B3A-232-A
MM-B3A-234-A
MANIFOLD BASE Port size
Manifold fastening kit: N-P3003-01. Valve blanking plate: M-P3001. Inlet/exhaust isolator plug: 32845.
Individual Base Options: MB-A3B-XXXF Optional Integral Flow Controls
239
Consult “Precautions” page 327 before use, installation or service of MAC Valves..