Page 11

100%

WARRANTY

18

OF PRODUCTION TESTED

100%

MONTHS

Series ISO 3 DIMENSIONS

Dimensions shown are metric (mm)

Individual

ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES

140,0 70,0 35,0 17,5 15,0

12

2

32,0

14

39,5

4

64,0

2

46,0 33,0 27,0

4

43,5

79,0 21,0

55,0

3

22,0 45,0

1

15,0

45,0

49,0

49,0 OPTIONAL BOTTOM PORTS

78,0

20,5 20,5 49,0

5

156,0

49,0

1/8” EXTERNAL PILOT/ REMOTE AIR PILOT PORT (2 PLACES)

Manifold 26.5 12

P

77,9 50.0

23.0 2

4

40.0

19.0 8.25 DIA. THRU 2 MTG HOLES

136.4 99.9 2

25.8 33.4 65.8 1

48.8 32.8

63.3

3

47.0 27.8

19.0 39.0 59.0

78.0

48.0

31.0

5 1

3 4

5

COND

27.0

17.3

208.0

50.2

9.0 55.7

96.0 140.0 162.0 175.2 188.9 232.1

240

Consult “Precautions” page 327 before use, installation or service of MAC Valves..

Page 12

B a s e s a c c o r d i n g t o

I S O

5 5 9 9 / 1

Series ISO 3 Series Plug-in manifold

ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 HOW TO ORDER

MANIFOLD BASE Port size

1/2” NPTF

3/4” NPTF

Wired for

Side ports

Side ports w/ bottom 2 & 4 ports

All side & bottom ports (see note) MM-P3A-223-A

Single solenoid

MM-P3A-221-A

MM-P3A-222-A

Double solenoid

MM-P3A-221-B

MM-P3A-222-B

MM-P3A-223-B

Single solenoid

MM-P3A-231-A

MM-P3A-232-A

MM-P3A-233-A

Double solenoid

MM-P3A-231-B

MM-P3A-232-B

MM-P3A-233-B

Note : Ports 1, 3 & 5 are always 3/4”

OPTIONS

Manifold options :

External pilot

MM-P3A-22X-X 25 26

Terminal strip for 1/2" port – common external pilot for 3/4" port – common external pilot

MM-P3A-XXX-A J K light(s)

wired for sgl solenoid wired for double solenoid

MM-P3A-XXX-XJA JA 110/120 volt JB 220/240 volt DA 24 volt

Accessories:

M-P3001 N-P3003-01 32845

Valve blanking plate. Manifold fastening kit. Inlet/exhaust isolator plug.

241

Consult “Precautions” page 327 before use, installation or service of MAC Valves..

Page 13

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series ISO 3 DIMENSIONS

WATTS

VAC TO 120 PSI

MODEL

ELECTRICAL

WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z.

MODIF.

Dimensions shown are metric (mm)

139.4

29.0

23.5

28.5

31.0 48.5 69.0 89.5 106.5 142.0 193.0

166.5 8.25 DIA THRU 2 MTG HOLES

107.0 69.0 31.0 5

1

3

24.5

8.5

69.5 54.5

62.0 4

79.0

2

14

12

158.0

24.0 51.5 86.5 114.0

242

Consult “Precautions” page 327 before use, installation or service of MAC Valves..

Page 14

B a s e s a c c o r d i n g t o

I S O

5 5 9 9

Series ISO 3 Series

ISO 1 ISO 2 ISO 3

HOW TO ORDER

INDIVIDUAL BASE Port size

Side ports

Side & bottom ports

Bottom cylinder ports 2 and 4.

Bottom inlet port 1

1/2” NPTF

MB-A3B-221

MB-A3B-223

MB-A3B-222

MB-A3B-224

3/4” NPTF

MB-A3B-231

MB-A3B-233

MB-A3B-232

MB-A3B-234

289

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 15

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series ISO 3 Dimensions shown are metric (mm)

DIMENSIONS

Individual

ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES

140,0 70,0 35,0 17,5 15,0

12

32,0

14

2

39,5

4

64,0 46,0

2

33,0 27,0

4 22,0

43,5

15,0

20,5 20,5

1/8” EXTERNAL PILOT

49,0

1

3

45,0

45,0

79,0 21,0

55,0

49,0

5 49,0 78,0

156,0

OPTIONAL BOTTOM PORTS

49,0

290

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 16

OPTIONS

Codification table for voltages / Manual operator / Electrical connection

VALVE CODE ®

-DM- D XX X-X XX 1 2 3 4 OPTIONS AVAILABLE FOR

- Pilot operated valves 52, 67, 92, 93, 400, ISO1, ISO2, ISO3 Series

309

Consult “Precautions” page 327 before use, installation or service of MAC Valves..

Page 17

OPTIONS 1. VOLTAGE

D-XX X-X XX

VOLTAGE

4. ELECTRICAL CONNECTION

D-XX X-X XX

ELECTRICAL CONNECTION

DA

24 VDC (5.4W)

BA*

Flying leads (grommet)

DB

12 VDC (5.4W)

BK*

BA with protection diode

DC

12 VDC (7.5W)

BL*

BA with protection varistor

DD

24 VDC (7.3W)

BM**

Flying leads (solenoid plug-in)

DE

12 VDC (12.7W)

BN**

BM with protection diode

DF

24 VDC (12.7W)

BP**

BM with protection varistor

DK

110 VDC (4.7W)

BG**

BM with ground

DJ

28 VDC (5.2W)

BH**

BM with protection diode & ground

DL

64 VDC (6.0W)

BJ**

BM with protection varistor & ground

DM

36 VDC (5.3W)

CA*

1/2" NPS conduit with flying leads

DN

6 VDC (6.0W)

CM*

1/2" NPS metal conduit with flying leads

DR

90 VDC (6.6W)

CN*

1/2" NPS metal conduit with flying leads & ground

DS

110 VDC (7.3W)

JB

Rectangular connector

DT

75 VDC (5.6W)

JD

JB with light

DP

48 VDC (5.8W)

JM

Rectangular connector (male only)

FA

12 VDC (1.8W)

KA

Mini square connector

FB

24 VDC (1.8W)

KB

KA with protection diode

FE

12 VDC (2.4W)

KC

KA with protection varistor

FF

24 VDC (2.4W)

KD

KA with light

JA

120/60, 110/50 (2.9W)

KE

KA with light and protection diode

JB

240/60, 220/50 (2.9W)

KF

KA with light and protection varistor

JC

24/60, 24/50 (3.7W)

KG

KA with light & diode

JD

100/60, 100/50, 110/60 (3.9W)

KJ

Mini square connector (male only)

JE

220/60 (3.4W)

KK

KJ with protection diode (male only)

JF

240/50 (2.8W)

KL

KJ with protection varistor (male only)

JG

200/60, 200/50 (3.9W)

TA

Dual tabs with receptacles

TB

TA with protection diode

TD

TA with light

TE

TA with light and protection diode

WIRE LENGTH

TJ

Dual tabs (male only)

0

No wires

TK

TJ with protection diode

A

18"

TM

TJ with light

B

24"

TN

TJ with light and protection diode

C

36"

* From Lead wire length options choose A through F

D

48"

** From Lead wire length options choose 0 through F

E

72"

Note: When coil is above 30 volts, a ground wire is required. Applies to options

F

96" with flying leads.

2. WIRE LENGTH

D-XX X-X XX

3. MANUAL OPERATOR

D-XX X-X XX

MANUAL OPERATOR

0

No operator

1

Non-locking recessed

2

Locking recessed

3

Non-locking extended

4

Locking extended

310

Consult “Precautions” page 327 before use, installation or service of MAC Valves..

Page 18

R e m o t e a i r v a l v e s

Series ISO 3 Function

Port size

Flow (Max)

5/2 - 5/3

1/2" - 3/4"

6.3 Cv

Individual mounting

Series valve only

OPERATIONAL BENEFITS

1100

1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate.

55 56 57 58

HOW TO ORDER

59

SINGLE PRESSURE VALVES Air spring

5/2 Single operator

5/2 Double operator

14

14

4 2

5

12

1 3

4 2

5

5/3 Closed center 14

12

4 2

5

1 3

1

5/3 Open center 14

12

4 2

5

3

1

3

900

Internal

MV-A3B-B111

-----

-----

-----

External

MV-A3B-B121

MV-A3B-B221

MV-A3B-B322

MV-A3B-B321

82

DUAL PRESSURE VALVES Air spring

700 12

5/2 Single operator

5/2 Double operator

5/3 Pressure center

14

14

14

4 2

5

12

4 2

5

1 3

1

12

3

4

5

2

1

12

3

Internal port 3

MV-A3B-B131

-----

-----

Internal port 5

MV-A3B-B135

-----

-----

External

MV-A3B-B141

MV-A3B-B241

MV-A3B-B341

Note : ISO valves are delivered w/o base. See page 273 for base code.

6300 6500 6600 2700 1800 ISO 1 ISO 2 ISO 3

257

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 19

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series ISO 3 TECHNICAL DATA

Fluid :

Compressed air, vacuum, inert gases

Pressure range :

Vacuum to 150 PSI

Air signal pressure :

Single operator and 3 positions : 25 to 150 PSI ≥ main valve pressure

Lubrication :

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)

Filtration :

40 µ

Temperature range :

0°F to 120°F (-18°C to 50°C)

Flow (at 6 bar, ΔP=1bar) :

1/2" - 3/4” : (6.3 Cv)

Leak rate :

100 cm3/min

Spare parts :

• Remote air operator : R-A3004. • Pressure seal between valve and base : 16436. • Mounting screw body to base (x4) : 35416.

Double operator : 10 to 150 PSI

Dimensions shown are metric (mm)

DIMENSIONS

124,4 12

46,0

14

2

33,0 27,0

4 22,0

43,5

55,0

70,0 35,0 17,5

20,5 20,5 49,0 1/8” REMOTE PILOT

Ø 8,3 -4 MTG. HOLES

140,0

45,0

45,0

15,0

49,0 168,0

32,0

2

39,5

4

64,0

79,0 21,0

1

3 15,0

49,0

49,0 78,0 156,0

258

5

OPTIONAL BOTTOM PORTS

Consult “Precautions” page 356 before use, installation or service of MAC Valves.

Page 20

Direct solenoid and solenoid pilot operated valves

Series ISO 3 Series

Individual mounting valve only

35

Manifold mounting valve only

100

Bonded flow seal spool

Pilot air accumulator

Manual operator

200 55 56 57 58 59

Air/spring return

External pilot port

45 3

5

1 2

4

700 900 82 6300 series features

6500

• Fastest available response time with patented Macsolenoid®. • No-stick operation is ensured by wiping action of unique MAC spool/bore combination. • Balanced poppet pilot valve for high flow, precise repeatability, and consistent operation. • Large spool piston for high shifting force even at minimum operating pressure • Air/spring return for consistent shifting on single solenoid models. • Patented virtually burn-out proof AC solenoid. • Optional low wattage DC solenoids down to 1.0 watt. • Various manual operators & electrical connectors are available. • Muffled or threaded pilot exhaust ports. • Internal of external pilot models available.

165

Consult “Precautions” page 364 before use, installation or service of MAC Valves

6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A