The text of a spec sheet · part 2 of 3
Direct solenoid and solenoid pilot operated valves, Series ISO 3, pages 11 to 20
Pages 11 to 20 of 29
The original document is the PDF (950 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the MAC Valves MV-A2B-A141-PM-111DA and MAC Valves MV-A2B-A341-PM-111DA
Page 11
100%
WARRANTY
18
OF PRODUCTION TESTED
100%
MONTHS
Series ISO 3 DIMENSIONS
Dimensions shown are metric (mm)
Individual
ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES
140,0 70,0 35,0 17,5 15,0
12
2
32,0
14
39,5
4
64,0
2
46,0 33,0 27,0
4
43,5
79,0 21,0
55,0
3
22,0 45,0
1
15,0
45,0
49,0
49,0 OPTIONAL BOTTOM PORTS
78,0
20,5 20,5 49,0
5
156,0
49,0
1/8” EXTERNAL PILOT/ REMOTE AIR PILOT PORT (2 PLACES)
Manifold 26.5 12
P
77,9 50.0
23.0 2
4
40.0
19.0 8.25 DIA. THRU 2 MTG HOLES
136.4 99.9 2
25.8 33.4 65.8 1
48.8 32.8
63.3
3
47.0 27.8
19.0 39.0 59.0
78.0
48.0
31.0
5 1
3 4
5
COND
27.0
17.3
208.0
50.2
9.0 55.7
96.0 140.0 162.0 175.2 188.9 232.1
240
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 12
B a s e s a c c o r d i n g t o
I S O
5 5 9 9 / 1
Series ISO 3 Series Plug-in manifold
ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 HOW TO ORDER
MANIFOLD BASE Port size
1/2” NPTF
3/4” NPTF
Wired for
Side ports
Side ports w/ bottom 2 & 4 ports
All side & bottom ports (see note) MM-P3A-223-A
Single solenoid
MM-P3A-221-A
MM-P3A-222-A
Double solenoid
MM-P3A-221-B
MM-P3A-222-B
MM-P3A-223-B
Single solenoid
MM-P3A-231-A
MM-P3A-232-A
MM-P3A-233-A
Double solenoid
MM-P3A-231-B
MM-P3A-232-B
MM-P3A-233-B
Note : Ports 1, 3 & 5 are always 3/4”
OPTIONS
Manifold options :
External pilot
MM-P3A-22X-X 25 26
Terminal strip for 1/2" port – common external pilot for 3/4" port – common external pilot
MM-P3A-XXX-A J K light(s)
wired for sgl solenoid wired for double solenoid
MM-P3A-XXX-XJA JA 110/120 volt JB 220/240 volt DA 24 volt
Accessories:
M-P3001 N-P3003-01 32845
Valve blanking plate. Manifold fastening kit. Inlet/exhaust isolator plug.
241
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 13
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series ISO 3 DIMENSIONS
WATTS
VAC TO 120 PSI
MODEL
ELECTRICAL
WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z.
MODIF.
Dimensions shown are metric (mm)
139.4
29.0
23.5
28.5
31.0 48.5 69.0 89.5 106.5 142.0 193.0
166.5 8.25 DIA THRU 2 MTG HOLES
107.0 69.0 31.0 5
1
3
24.5
8.5
69.5 54.5
62.0 4
79.0
2
14
12
158.0
24.0 51.5 86.5 114.0
242
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 14
B a s e s a c c o r d i n g t o
I S O
5 5 9 9
Series ISO 3 Series
ISO 1 ISO 2 ISO 3
HOW TO ORDER
INDIVIDUAL BASE Port size
Side ports
Side & bottom ports
Bottom cylinder ports 2 and 4.
Bottom inlet port 1
1/2” NPTF
MB-A3B-221
MB-A3B-223
MB-A3B-222
MB-A3B-224
3/4” NPTF
MB-A3B-231
MB-A3B-233
MB-A3B-232
MB-A3B-234
289
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 15
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series ISO 3 Dimensions shown are metric (mm)
DIMENSIONS
Individual
ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES
140,0 70,0 35,0 17,5 15,0
12
32,0
14
2
39,5
4
64,0 46,0
2
33,0 27,0
4 22,0
43,5
15,0
20,5 20,5
1/8” EXTERNAL PILOT
49,0
1
3
45,0
45,0
79,0 21,0
55,0
49,0
5 49,0 78,0
156,0
OPTIONAL BOTTOM PORTS
49,0
290
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 16
OPTIONS
Codification table for voltages / Manual operator / Electrical connection
VALVE CODE ®
-DM- D XX X-X XX 1 2 3 4 OPTIONS AVAILABLE FOR
- Pilot operated valves 52, 67, 92, 93, 400, ISO1, ISO2, ISO3 Series
309
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 17
OPTIONS 1. VOLTAGE
D-XX X-X XX
VOLTAGE
4. ELECTRICAL CONNECTION
D-XX X-X XX
ELECTRICAL CONNECTION
DA
24 VDC (5.4W)
BA*
Flying leads (grommet)
DB
12 VDC (5.4W)
BK*
BA with protection diode
DC
12 VDC (7.5W)
BL*
BA with protection varistor
DD
24 VDC (7.3W)
BM**
Flying leads (solenoid plug-in)
DE
12 VDC (12.7W)
BN**
BM with protection diode
DF
24 VDC (12.7W)
BP**
BM with protection varistor
DK
110 VDC (4.7W)
BG**
BM with ground
DJ
28 VDC (5.2W)
BH**
BM with protection diode & ground
DL
64 VDC (6.0W)
BJ**
BM with protection varistor & ground
DM
36 VDC (5.3W)
CA*
1/2" NPS conduit with flying leads
DN
6 VDC (6.0W)
CM*
1/2" NPS metal conduit with flying leads
DR
90 VDC (6.6W)
CN*
1/2" NPS metal conduit with flying leads & ground
DS
110 VDC (7.3W)
JB
Rectangular connector
DT
75 VDC (5.6W)
JD
JB with light
DP
48 VDC (5.8W)
JM
Rectangular connector (male only)
FA
12 VDC (1.8W)
KA
Mini square connector
FB
24 VDC (1.8W)
KB
KA with protection diode
FE
12 VDC (2.4W)
KC
KA with protection varistor
FF
24 VDC (2.4W)
KD
KA with light
JA
120/60, 110/50 (2.9W)
KE
KA with light and protection diode
JB
240/60, 220/50 (2.9W)
KF
KA with light and protection varistor
JC
24/60, 24/50 (3.7W)
KG
KA with light & diode
JD
100/60, 100/50, 110/60 (3.9W)
KJ
Mini square connector (male only)
JE
220/60 (3.4W)
KK
KJ with protection diode (male only)
JF
240/50 (2.8W)
KL
KJ with protection varistor (male only)
JG
200/60, 200/50 (3.9W)
TA
Dual tabs with receptacles
TB
TA with protection diode
TD
TA with light
TE
TA with light and protection diode
WIRE LENGTH
TJ
Dual tabs (male only)
0
No wires
TK
TJ with protection diode
A
18"
TM
TJ with light
B
24"
TN
TJ with light and protection diode
C
36"
* From Lead wire length options choose A through F
D
48"
** From Lead wire length options choose 0 through F
E
72"
Note: When coil is above 30 volts, a ground wire is required. Applies to options
F
96" with flying leads.
2. WIRE LENGTH
D-XX X-X XX
3. MANUAL OPERATOR
D-XX X-X XX
MANUAL OPERATOR
0
No operator
1
Non-locking recessed
2
Locking recessed
3
Non-locking extended
4
Locking extended
310
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Page 18
R e m o t e a i r v a l v e s
Series ISO 3 Function
Port size
Flow (Max)
5/2 - 5/3
1/2" - 3/4"
6.3 Cv
Individual mounting
Series valve only
OPERATIONAL BENEFITS
1100
1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate.
55 56 57 58
HOW TO ORDER
59
SINGLE PRESSURE VALVES Air spring
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
1 3
4 2
5
5/3 Closed center 14
12
4 2
5
1 3
1
5/3 Open center 14
12
4 2
5
3
1
3
900
Internal
MV-A3B-B111
-----
-----
-----
External
MV-A3B-B121
MV-A3B-B221
MV-A3B-B322
MV-A3B-B321
82
DUAL PRESSURE VALVES Air spring
700 12
5/2 Single operator
5/2 Double operator
5/3 Pressure center
14
14
14
4 2
5
12
4 2
5
1 3
1
12
3
4
5
2
1
12
3
Internal port 3
MV-A3B-B131
-----
-----
Internal port 5
MV-A3B-B135
-----
-----
External
MV-A3B-B141
MV-A3B-B241
MV-A3B-B341
Note : ISO valves are delivered w/o base. See page 273 for base code.
6300 6500 6600 2700 1800 ISO 1 ISO 2 ISO 3
257
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 19
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series ISO 3 TECHNICAL DATA
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Vacuum to 150 PSI
Air signal pressure :
Single operator and 3 positions : 25 to 150 PSI ≥ main valve pressure
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ΔP=1bar) :
1/2" - 3/4” : (6.3 Cv)
Leak rate :
100 cm3/min
Spare parts :
• Remote air operator : R-A3004. • Pressure seal between valve and base : 16436. • Mounting screw body to base (x4) : 35416.
Double operator : 10 to 150 PSI
Dimensions shown are metric (mm)
DIMENSIONS
124,4 12
46,0
14
2
33,0 27,0
4 22,0
43,5
55,0
70,0 35,0 17,5
20,5 20,5 49,0 1/8” REMOTE PILOT
Ø 8,3 -4 MTG. HOLES
140,0
45,0
45,0
15,0
49,0 168,0
32,0
2
39,5
4
64,0
79,0 21,0
1
3 15,0
49,0
49,0 78,0 156,0
258
5
OPTIONAL BOTTOM PORTS
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Page 20
Direct solenoid and solenoid pilot operated valves
Series ISO 3 Series
Individual mounting valve only
35
Manifold mounting valve only
100
Bonded flow seal spool
Pilot air accumulator
Manual operator
200 55 56 57 58 59
Air/spring return
External pilot port
45 3
5
1 2
4
700 900 82 6300 series features
6500
• Fastest available response time with patented Macsolenoid®. • No-stick operation is ensured by wiping action of unique MAC spool/bore combination. • Balanced poppet pilot valve for high flow, precise repeatability, and consistent operation. • Large spool piston for high shifting force even at minimum operating pressure • Air/spring return for consistent shifting on single solenoid models. • Patented virtually burn-out proof AC solenoid. • Optional low wattage DC solenoids down to 1.0 watt. • Various manual operators & electrical connectors are available. • Muffled or threaded pilot exhaust ports. • Internal of external pilot models available.
165
Consult “Precautions” page 364 before use, installation or service of MAC Valves
6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A