Page 21

100% OF PRODUCTION TESTED

100%

18 WARRANTY

MONTHS

Series ISO 3

VALVE CONFIGURATIONS AVAILABLE

• 2-Pos., single or double operators (solenoid or remote air). • Single or dual pressure. • double operator-closed center, open center or pressure center (solenoid or remote air). • Individual base. • Internal pilot or external pilot (including a common external pilot or manifold models). • Side porting and bottom porting options. *International Standards Organization ISO Common Base Interface (ISO Std. 5599/1) SPECIAL APPLICATION INSTRUCTIONS :

On all models, energizing the "14" operator (solenoid or remote air) connects Port #1 to Cylinder Port #4 and energizing the "12" operator connects Port #1 to Cylinder Port #2. For the following special applications, additional piping considerations are required. EXTERNAL PILOT APPLICATIONS* - An External Pilot Supply is only required when the main valve pressure is less than 1.8 BARS on single operators (soleneoid or remote air) or 0.7 BARS on double solenoid valves only. In these cases, use an External Pilot model and supply a minimum of 1.8 BARS for single operators or a minimum of 0.7 BARS for double solenoid valves to either the "14" or "12" External Pilot Port of the valve base. VACUUM APPLICATIONS - Use an External Pilot model as described above and also connect the vacuum source to Port #3 & 5 and leave Port#1 open to atmosphere on single pressure models. On two pressure models, reverse the single pressure piping. SELECTOR APPLICATIONS - Use an External Pilot Model as described above if both pressures are below the minimum, otherwise use an Internal Pilot model and connect the higher pressure to Port #1 and the lower pressure to either Port #3 or 5 depending on which Cylinder Port is to be active. TWO PRESSURE APPLICATIONS - For Internal Pilot models specify the model number for connecting either port #3 or 5, whichever is to be the higher pressure, to the Internal Pilot supply. For external Pilot models, pipe as described above for "External Pilot Application." *Note: 1Bar = 14.5 PSIG

166

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 22

Direct solenoid and solenoid pilot operated valves

Series ISO 3 Function

Port size

Flow (Max)

5/2 - 5/3

1/2” - 3/4”

6.3 Cv

Series

Individual mounting & Manifold mounting valve only operational benefits

35

1. spool, immune to variations of pressure. 2. stroke with high flow. 3. piston (booster) provides maximum shifting forces. 4. return force thanks to the combination of mechanical and air springs. 5. spool with minimum friction, shifting in a glass-like finished bore. 6. effect eliminates sticking. 7. valve with balanced poppet, high flow, short and consistent response times. 8. service life.

100 200 55 56 57 58 59 how to order

Single pressure valves Pilot air

5/2 Single operator

5/2 Double operator

14

14

4 2

5

12

4 2

1 3

5

1

5/3 Closed center 14

12

4 2

5

3

1

5/3 Open center 12

14

4

3

5

2

1

12

3

Internal

MV-A3B-A111-PM-XXYZZ

MV-A3B-A211-PM-XXYZZ

MV-A3B-A312-PM-XXYZZ

MV-A3B-A311-PM-XXYZZ

External

MV-A3B-A121-PM-XXYZZ

MV-A3B-A221-PM-XXYZZ

MV-A3B-A322-PM-XXYZZ

MV-A3B-A321-PM-XXYZZ

45

Dual pressure valves Pilot air

5/2 Single operator

5/2 Double operator

5/3 Pressure center

14

14

14

4 2

5

12

4 2

5

1 3

1

12

5

3

1

3

Internal port 3

MV-A3B-A131-PM-XXYZZ

MV-A3B-A231-PM-XXYZZ

MV-A3B-A331-PM-XXYZZ

Internal port 5

MV-A3B-A135-PM-XXYZZ

MV-A3B-A232-PM-XXYZZ

MV-A3B-A332-PM-XXYZZ

External

MV-A3B-A141-PM-XXYZZ

MV-A3B-A241-PM-XXYZZ

MV-A3B-A341-PM-XXYZZ

XX Y ZZ *

SOLENOID OPERATOR ➤

XX

Voltage

Y

Manual operator

11 12 22 59 87 61

120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (2.5 W) 24 VDC (17.1 W) 24 VDC (8.5 W)

1 2

Non-locking Locking

900 82 6300

Electrical connection ZZ JB Rectangular connector JD connector with light JA Square connector JC connector with light BA Flying leads (18”)

Note : Photo shown with JC connector.

* Other options available, see page 357. Note : ISO valves are delivered w/o base. See page 281 for base code. options

MV-A3B-A111-PM-XXYZZ

- For CNOMO pilot, consult factory. - universal spool replace by 6 (2 position, sgl. pressure valves only) - use with single pressure sandwich regulator, replace by 5.

167

700

12

Consult “Precautions” page 364 before use, installation or service of MAC Valves

6500 6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A

Page 23

100% OF PRODUCTION TESTED

100%

18 WARRANTY

MONTHS

Series ISO 3 technical data

Fluid :

Compressed air, vacuum, inert gases

Pressure range :

Internal pilot : single operator and 3 positions : 25-150 PSI double operator : 10-150 PSI

External pilot : vacuum to 150 PSI Pilot pressure :

Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI

Lubrication :

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)

Filtration :

40 µ

Temperature range :

0°F to 120°F (-18°C to 50°C)

Flow (at 6 bar, ∆P=1bar) :

1/2" : (6.3 Cv), 3/4" : (6.3 Cv)

Leak rate :

200 cm3/min

Coil :

Epoxy encapsulated - class A wires - Continuous duty

Voltage range :

-15% to +10% of nominal voltage

Protection :

Consult factory

Power :

∼ Inrush : 14.8 VA

Holding : 10.9 VA

= 1 to 17.1 W Response times :

24 VDC (8.5 W)

Energize : 18 ms

De-energize : 20 ms

120/60

Energize : 15-25 ms

De-energize : 19-28 ms

• Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 35206 and seal 16234. • Pilot valve : PME-XXYZZ, including seal 16337. • Pressure seal between valve and base : 16436. • Mounting screw valve to base (x4) : 35416. • Check valve : 70002 (+M-00011).

parts :

dimensions

Dimensions shown are metric (mm)

A B 119,9

136,2 124,4 12

46,0

14

4

2

33,0 27,0

22,0 45,0

43,5

55,0

45,0 20,5 20,5

1/8” EXTERNAL PILOT

49,0

49,0

140,0

168,0

ISO 3 Individual mounting TYPE

15,0

A

B

JA & JC

326.6

247.3

JB & JD

349.6

258.8

Ø 8,3 MTG. HOLES

70,0 35,0 17,5

32,0

39,5

4

2

64,0

79,0 21,0

1

3 15,0

49,0

49,0 78,0 156,0

168

5

OPTIONAL BOTTOM PORTS

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 24

B a s e s a c c o r d i n g t o

I S O

5 5 9 9

Series ISO 3 Series

ISO 1 ISO 2 ISO 3

HOW TO ORDER

INDIVIDUAL BASE Port size

Side ports

Side & bottom ports

Bottom cylinder ports 2 and 4.

Bottom inlet port 1

1/2” NPTF

MB-A3B-221

MB-A3B-223

MB-A3B-222

MB-A3B-224

3/4” NPTF

MB-A3B-231

MB-A3B-233

MB-A3B-232

MB-A3B-234

Options: MB-A3B-XXXF

Optional Integral Flow Controls

289

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 25

100% OF PRODUCTION TESTED

100%

WARRANTY

18 MONTHS

Series ISO 3 Dimensions shown are metric (mm)

DIMENSIONS

Individual

ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES

140,0 70,0 35,0 17,5 15,0

12

32,0

14

2

39,5

4

64,0 46,0

2

33,0 27,0

4 22,0

45,0

43,5

15,0

45,0

49,0

1

3

20,5 20,5

1/8” EXTERNAL PILOT

79,0 21,0

55,0

49,0

5 49,0 78,0

156,0

OPTIONAL BOTTOM PORTS

49,0

290

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 26

O p t i o n

OPTIONS

Codification table for voltages / Manual operator / Electrical connection / Wire length

VALVE CODE ³

- XX Y ZZ (-VV) 1 2 3 4

OPTIONS AVAILABLE FOR

- valves type 100 Series

OPTIONS AVAILABLE FOR

- valves type 200 Series

- pilot valves "CNOMO"

- Pilot operated valves with pilots type 100 Series

- pilot operated valves with pilots type 200 Series

Series : 55 - 56 - 700 - 800 - 900

Series : 200 - 57 - 58 - 59.

- 6300 - 6500 - 6600 - 1300 - ISO 1 - ISO 2 - ISO 3. - MAC 125 - MAC 250 - MAC 500

- Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

357

Consult “Precautions” page 364 before use, installation or service of MAC Valves s

Page 27

I n t r i n s i c a l l y

Series ISO 1-2-3

MV-A1C ISO 1 MV-A2B ISO 2 MV-A3B ISO 3

S a f e

V a l v e s

MAC ISO valves are built to International Standards Organization (ISO) Std. 5599/1. They are available in 3 sizes; ISO 1, 2 & 3. To select th ISO size required, insert the appropriate ISO number in the 5th position of the model code; EXAMPLE MV-A1C for ISO 1, MV-A2B for ISO 2, or MV-A3B for ISO 3. Bases and manifolds must be ordered separately from the table below.

HOW TO ORDER

SOLENOID PILOT OPERATED VALVES LESS BASE SINGLE PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN

DBL. OPERATOR 2-POSITION

PILOT SUPPLY

DBL. OPER. 3-POS. CLOSED CENTER

DBL. OPER. 3-POS. OPEN CENTER

MV-AXB-A111-FM-A51JA MV-AXB-A121-FM-A51JA MV-AXB-A151-FM-A51JA

MV-AXB-A211-FM-A51JA MV-AXB-A221-FM-A51JA MV-AXB-A251-FM-A51JA

Internal Pilot External Pilot External Pilot for use with Regulator

MV-AXB-A312-FM-A51JA MV-AXB-A322-FM-A51JA MV-AXB-A352-FM-A51JA

MV-AXB-A311-FM-A51JA MV-AXB-A321-FM-A51JA MV-AXB-A351-FM-A51JA

SGL. OPERATOR AIR/SPRING RETURN

DBL. OPERATOR 2-POSITION

PILOT SUPPLY

DBL. OPER. 3-POS. PRESSURE CENTER

MV-AXB-A131-FM-A51JA MV-AXB-A135-FM-A51JA MV-AXB-A141-FM-A51JA

MV-AXB-A231-FM-A51JA MV-AXB-A232-FM-A51JA MV-AXB-A241-FM-A51JA

Int. Pilot-From Port 3 Int. Pilot-From Port 5 External Pilot

MV-AXB-A331-FM-A51JA MV-AXB-A332-FM-A51JA MV-AXB-A341-FM-A51JA

DUAL PRESSURE VALVES

SOLENOID PILOT VALVE OPTIONS XX - XXYZZ XX PILOT EXHAUST

XX DC VOLTAGE

Y

MANUAL OPERATOR

ZZ EXTERNAL PLUG-IN

ZZ ENCLOSURE

FM Muffled exhaust FP Piped exhaust

A5 12 VDC (0.6 W) A6 24 VDC (0.6 W)

0 1 2 3 4

No operator Non-locking Recessed (std.) Locking Recessed Non-locking Extended Locking Extended

JA Square without light (on solenoid) JB Rectangular without light (on solenoid) JE Square without light (on body) JF Rectangular without light (on body)

AA JIC w/1/2" NPS Conduit BA Grommet CA Conduit 1/2" NPS CC Conduit 1/2" NPT (CSA Threads)

BASE TABLE ISO TYPE

PORT SIZE

INDIVIDUAL BASE BSPP NPTF

MANIFOLD BASE BSPP NPTF

ISO 1

1/4" 3/8"

MB-A1C-121 MB-A1C-131

MB-A1C-221 MB-A1C-231

MM-A1C-121 MM-A1C-131

MM-A1C-221 MM-A1C-231

ISO 2

3/8" 1/2"

MB-A2B-121 MB-A2B-131

MB-A2B-221 MB-A2B-231

MM-A2B-121 MM-A2B-131

MM-A2B-221 MM-A2B-231

ISO 3

1/2" 3/4"

MB-A3B-121 MB-A3B-131

MB-A3B-221 MB-A3B-231

MM-A3B-121 MM-A3B-131

N/A N/A

For manifold bases a common external pilot port is available. One connection only is required for all valves in the manifold whether single or double solenoid. Bottom ports are also available; consult factory for ordering information for these options. MANIFOLD FASTENING KIT, For each gang, one kit is required. To order specify par number N-63002-01.

351

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 28

OPTIONS Used on valve series: 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, MVA2B, MVA3B, MAC125, MAC250, MAC500.

Used on valve series: 200, 57, 58, 59.

1. VOLTAGE (200 Serie type coil)

1. VOLTAGE (100 Serie type coil) - XX Y

ZZ

VOLTAGE

- XX Y

ZZ

VOLTAGE

11

120/60, 110/50

11

120/60, 110/50, 24 VDC (6 W)

12

240/60, 220/50

12

240/60, 220/50

13

100/60, 100/50

13

100/60, 100/50

15

200/60, 200 /50

14

200/60, 200/50

16

10/60

20

6/60

20

6/60

21

12/60

21

12/50, 12/60

22

24/60, 24/50

22

24/60, 24/50

23

32/60, 32/50

23

32/60, 32/50

24

48/60, 42/50

24

48/60, 42/50

25

240/50

26*

380/50, 440/50, 440/60, 480/60

26

480/60, 440/50

29

220/60

27

127/60

34

127/50, 120/50

28

415/50

35

48/50

29

220/60

36

16/60

30

380/50

B1

24/50

31

550/60, 550/50

50

24 VDC (6 W)

32

120/60, 110/50

51

24 VDC (4 W)

33

600/60

54

12 VDC (4 W)

34

127/50

55

12 VDC (6 W)

35

48/50

57

12 VDC (2.5 W)

50

24 VDC (6 W)

59

24 VDC (2.5 W)

51

24 VDC (4.5 W)

60

12 VDC (8.5 W)

52

24 VDC (2.5 W)

61

24 VDC (8.5 W)

53

24 VDC (1.0 W)

64

6 VDC (6 W)

55

12 VDC (6 W)

65

32 VDC (7 W)

57

12 VDC (2.5 W)

66

48 VDC (5.8 W)

58

48 VDC (2.5 W)

67

64 VDC (7.5 W)

60

12 VDC (9.5 W)

68

120 VDC (6.4 W)

61

24 VDC (8.5 W)

69*

220 VDC (8.7 W), 250 VDC (11.2 W)

64

6 VDC (8.5 W)

75

90 VDC (8.8 W)

65

32 VDC (10 W)

76*

100 VDC (6.9 W)

66

48 VDC (11.5 W)

84*

125 VDC (10.9 W)

67

64 VDC (10.5 W)

87*

24 VDC (17.1 W)

68

120 VDC (12.3 W)

88*

12 VDC (17.4 W)

69

250 VDC (9.2 W)

89*

36 VDC (18.8 W)

71

8 VDC (8.2 W)

90

28 VDC (8.2 W)

72

24 VDC (12 W)

91*

6 VDC (10.6 W)

73

198 VDC (10 W)

92

190 VDC (6.5 W)

74

72 VDC (11.3 W)

94

3 VDC (7 W)

75

90 VDC (11.3 W)

95

38 VDC (6.4 W)

76

100 VDC (9 W)

A1

24 VDC (1 W)

77

220 VDC (10 W), 230 VDC (11.6 W)

A2

12 VDC (1 W)

78*

24 VDC (24 W)

A3

9 VDC (1 W)

80

55 VDC (10.6 W)

MOD. DD01 : Protection diode (DC) - MAX. 8.5W

82

170 VDC (11.1 W)

MOD. MOV1 : Protection varistor (AC) - MAX. 8.5W

83

15 VDC (8.1 W)

* Voltages are CLSF only

84

125 VDC (10 W)

86

36 VDC (11 W)

93*

12 VDC (24 W)

358

Consult “Precautions” page 364 before use, installation or service of MAC Valves

Page 29

O p t i o n

OPTIONS

2. MANUAL OPERATOR (Common options for 100 & 200 Series type coils) - XX Y

ZZ

MANUAL OPERATOR

0

No operator

5*

No Operator with Light

1

Non-locking recessed

6*

Non-Locking Recessed with Light

2

Locking recessed

7*

Locking Recessed with Light

3

Non-locking extended

8*

Non-Locking Extended with Light

4

Locking extended

9*

Locking Extended with Light

* Lights used with “AA” electrical connection 3. ELECTRICAL CONNECTION (100 Serie type coil) - XX Y

3. ELECTRICAL CONNECTION (200 Serie type coil)

ZZ

ELECTRICAL CONNECTION

ZZ

ELECTRICAL CONNECTION

AA

Wiring box with 1/2" NPS conduit

AA

Wiring box with 1/2" NPS conduit

BA

Flying leads

BA

Flying leads

CA

1/2" NPS conduit

CA

1/2" NPS conduit

CC

1/2" NPT conduit

CC

1/2" NPT conduit

FA

Military type 2 PIN

EA

Explosion proof (200 Series)

GA

Military type 3 PIN

EA

Explosion proof (57, 58 & 59 Series)

HA

AA with ground wire

FA

Military type 2 PIN

JA*

Square connector

GA

Military type 3 PIN

JB

Rectangular connector

HA

AA with ground wire

JC*

Square connector with light

JA*

Square connector

JD

Rectangular connector with light

JC

Square connector with light

JE

Square connector on top

JJ

Square connector, male only

(ISO2, ISO3)

NA

CA with ground wire

Rectangular connector on top

NC

CC with ground wire

JF

- XX Y

(ISO1, ISO2, ISO3) JG

JE with light

JH

JF with light

JJ

Square connector, male only

JM

Rectangular connector, male only

MA

Electrical common conduit (100 Series-Manifold/900 Series)

MB

Electrical common conduit (100 Series-Stacking/700 Series)

NA

CA with ground wire

NC

CC with ground wire

RA

3/8" NPS conduit

* Not to be used with 100, 800 and 900 Series manifold mounting

359