Page 21
100% OF PRODUCTION TESTED
100%
18 WARRANTY
MONTHS
Series ISO 3
VALVE CONFIGURATIONS AVAILABLE
• 2-Pos., single or double operators (solenoid or remote air). • Single or dual pressure. • double operator-closed center, open center or pressure center (solenoid or remote air). • Individual base. • Internal pilot or external pilot (including a common external pilot or manifold models). • Side porting and bottom porting options. *International Standards Organization ISO Common Base Interface (ISO Std. 5599/1) SPECIAL APPLICATION INSTRUCTIONS :
On all models, energizing the "14" operator (solenoid or remote air) connects Port #1 to Cylinder Port #4 and energizing the "12" operator connects Port #1 to Cylinder Port #2. For the following special applications, additional piping considerations are required. EXTERNAL PILOT APPLICATIONS* - An External Pilot Supply is only required when the main valve pressure is less than 1.8 BARS on single operators (soleneoid or remote air) or 0.7 BARS on double solenoid valves only. In these cases, use an External Pilot model and supply a minimum of 1.8 BARS for single operators or a minimum of 0.7 BARS for double solenoid valves to either the "14" or "12" External Pilot Port of the valve base. VACUUM APPLICATIONS - Use an External Pilot model as described above and also connect the vacuum source to Port #3 & 5 and leave Port#1 open to atmosphere on single pressure models. On two pressure models, reverse the single pressure piping. SELECTOR APPLICATIONS - Use an External Pilot Model as described above if both pressures are below the minimum, otherwise use an Internal Pilot model and connect the higher pressure to Port #1 and the lower pressure to either Port #3 or 5 depending on which Cylinder Port is to be active. TWO PRESSURE APPLICATIONS - For Internal Pilot models specify the model number for connecting either port #3 or 5, whichever is to be the higher pressure, to the Internal Pilot supply. For external Pilot models, pipe as described above for "External Pilot Application." *Note: 1Bar = 14.5 PSIG
166
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 22
Direct solenoid and solenoid pilot operated valves
Series ISO 3 Function
Port size
Flow (Max)
5/2 - 5/3
1/2” - 3/4”
6.3 Cv
Series
Individual mounting & Manifold mounting valve only operational benefits
35
1. spool, immune to variations of pressure. 2. stroke with high flow. 3. piston (booster) provides maximum shifting forces. 4. return force thanks to the combination of mechanical and air springs. 5. spool with minimum friction, shifting in a glass-like finished bore. 6. effect eliminates sticking. 7. valve with balanced poppet, high flow, short and consistent response times. 8. service life.
100 200 55 56 57 58 59 how to order
Single pressure valves Pilot air
5/2 Single operator
5/2 Double operator
14
14
4 2
5
12
4 2
1 3
5
1
5/3 Closed center 14
12
4 2
5
3
1
5/3 Open center 12
14
4
3
5
2
1
12
3
Internal
MV-A3B-A111-PM-XXYZZ
MV-A3B-A211-PM-XXYZZ
MV-A3B-A312-PM-XXYZZ
MV-A3B-A311-PM-XXYZZ
External
MV-A3B-A121-PM-XXYZZ
MV-A3B-A221-PM-XXYZZ
MV-A3B-A322-PM-XXYZZ
MV-A3B-A321-PM-XXYZZ
45
Dual pressure valves Pilot air
5/2 Single operator
5/2 Double operator
5/3 Pressure center
14
14
14
4 2
5
12
4 2
5
1 3
1
12
5
3
1
3
Internal port 3
MV-A3B-A131-PM-XXYZZ
MV-A3B-A231-PM-XXYZZ
MV-A3B-A331-PM-XXYZZ
Internal port 5
MV-A3B-A135-PM-XXYZZ
MV-A3B-A232-PM-XXYZZ
MV-A3B-A332-PM-XXYZZ
External
MV-A3B-A141-PM-XXYZZ
MV-A3B-A241-PM-XXYZZ
MV-A3B-A341-PM-XXYZZ
XX Y ZZ *
SOLENOID OPERATOR ➤
XX
Voltage
Y
Manual operator
11 12 22 59 87 61
120/60, 110/50 240/60, 220/50 24/60, 24/50 24 VDC (2.5 W) 24 VDC (17.1 W) 24 VDC (8.5 W)
1 2
Non-locking Locking
900 82 6300
Electrical connection ZZ JB Rectangular connector JD connector with light JA Square connector JC connector with light BA Flying leads (18”)
Note : Photo shown with JC connector.
* Other options available, see page 357. Note : ISO valves are delivered w/o base. See page 281 for base code. options
MV-A3B-A111-PM-XXYZZ
- For CNOMO pilot, consult factory. - universal spool replace by 6 (2 position, sgl. pressure valves only) - use with single pressure sandwich regulator, replace by 5.
167
700
12
Consult “Precautions” page 364 before use, installation or service of MAC Valves
6500 6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A
Page 23
100% OF PRODUCTION TESTED
100%
18 WARRANTY
MONTHS
Series ISO 3 technical data
Fluid :
Compressed air, vacuum, inert gases
Pressure range :
Internal pilot : single operator and 3 positions : 25-150 PSI double operator : 10-150 PSI
External pilot : vacuum to 150 PSI Pilot pressure :
Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI
Lubrication :
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration :
40 µ
Temperature range :
0°F to 120°F (-18°C to 50°C)
Flow (at 6 bar, ∆P=1bar) :
1/2" : (6.3 Cv), 3/4" : (6.3 Cv)
Leak rate :
200 cm3/min
Coil :
Epoxy encapsulated - class A wires - Continuous duty
Voltage range :
-15% to +10% of nominal voltage
Protection :
Consult factory
Power :
∼ Inrush : 14.8 VA
Holding : 10.9 VA
= 1 to 17.1 W Response times :
24 VDC (8.5 W)
Energize : 18 ms
De-energize : 20 ms
120/60
Energize : 15-25 ms
De-energize : 19-28 ms
• Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 35206 and seal 16234. • Pilot valve : PME-XXYZZ, including seal 16337. • Pressure seal between valve and base : 16436. • Mounting screw valve to base (x4) : 35416. • Check valve : 70002 (+M-00011).
parts :
dimensions
Dimensions shown are metric (mm)
A B 119,9
136,2 124,4 12
46,0
14
4
2
33,0 27,0
22,0 45,0
43,5
55,0
45,0 20,5 20,5
1/8” EXTERNAL PILOT
49,0
49,0
140,0
168,0
ISO 3 Individual mounting TYPE
15,0
A
B
JA & JC
326.6
247.3
JB & JD
349.6
258.8
Ø 8,3 MTG. HOLES
70,0 35,0 17,5
32,0
39,5
4
2
64,0
79,0 21,0
1
3 15,0
49,0
49,0 78,0 156,0
168
5
OPTIONAL BOTTOM PORTS
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 24
B a s e s a c c o r d i n g t o
I S O
5 5 9 9
Series ISO 3 Series
ISO 1 ISO 2 ISO 3
HOW TO ORDER
INDIVIDUAL BASE Port size
Side ports
Side & bottom ports
Bottom cylinder ports 2 and 4.
Bottom inlet port 1
1/2” NPTF
MB-A3B-221
MB-A3B-223
MB-A3B-222
MB-A3B-224
3/4” NPTF
MB-A3B-231
MB-A3B-233
MB-A3B-232
MB-A3B-234
Options: MB-A3B-XXXF
Optional Integral Flow Controls
289
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 25
100% OF PRODUCTION TESTED
100%
WARRANTY
18 MONTHS
Series ISO 3 Dimensions shown are metric (mm)
DIMENSIONS
Individual
ISO DIN 5599/1 Ø 8,3 4 MTG. HOLES
140,0 70,0 35,0 17,5 15,0
12
32,0
14
2
39,5
4
64,0 46,0
2
33,0 27,0
4 22,0
45,0
43,5
15,0
45,0
49,0
1
3
20,5 20,5
1/8” EXTERNAL PILOT
79,0 21,0
55,0
49,0
5 49,0 78,0
156,0
OPTIONAL BOTTOM PORTS
49,0
290
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 26
O p t i o n
OPTIONS
Codification table for voltages / Manual operator / Electrical connection / Wire length
VALVE CODE ³
- XX Y ZZ (-VV) 1 2 3 4
OPTIONS AVAILABLE FOR
- valves type 100 Series
OPTIONS AVAILABLE FOR
- valves type 200 Series
- pilot valves "CNOMO"
- Pilot operated valves with pilots type 100 Series
- pilot operated valves with pilots type 200 Series
Series : 55 - 56 - 700 - 800 - 900
Series : 200 - 57 - 58 - 59.
- 6300 - 6500 - 6600 - 1300 - ISO 1 - ISO 2 - ISO 3. - MAC 125 - MAC 250 - MAC 500
- Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3
357
Consult “Precautions” page 364 before use, installation or service of MAC Valves s
Page 27
I n t r i n s i c a l l y
Series ISO 1-2-3
MV-A1C ISO 1 MV-A2B ISO 2 MV-A3B ISO 3
S a f e
V a l v e s
MAC ISO valves are built to International Standards Organization (ISO) Std. 5599/1. They are available in 3 sizes; ISO 1, 2 & 3. To select th ISO size required, insert the appropriate ISO number in the 5th position of the model code; EXAMPLE MV-A1C for ISO 1, MV-A2B for ISO 2, or MV-A3B for ISO 3. Bases and manifolds must be ordered separately from the table below.
HOW TO ORDER
SOLENOID PILOT OPERATED VALVES LESS BASE SINGLE PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN
DBL. OPERATOR 2-POSITION
PILOT SUPPLY
DBL. OPER. 3-POS. CLOSED CENTER
DBL. OPER. 3-POS. OPEN CENTER
MV-AXB-A111-FM-A51JA MV-AXB-A121-FM-A51JA MV-AXB-A151-FM-A51JA
MV-AXB-A211-FM-A51JA MV-AXB-A221-FM-A51JA MV-AXB-A251-FM-A51JA
Internal Pilot External Pilot External Pilot for use with Regulator
MV-AXB-A312-FM-A51JA MV-AXB-A322-FM-A51JA MV-AXB-A352-FM-A51JA
MV-AXB-A311-FM-A51JA MV-AXB-A321-FM-A51JA MV-AXB-A351-FM-A51JA
SGL. OPERATOR AIR/SPRING RETURN
DBL. OPERATOR 2-POSITION
PILOT SUPPLY
DBL. OPER. 3-POS. PRESSURE CENTER
MV-AXB-A131-FM-A51JA MV-AXB-A135-FM-A51JA MV-AXB-A141-FM-A51JA
MV-AXB-A231-FM-A51JA MV-AXB-A232-FM-A51JA MV-AXB-A241-FM-A51JA
Int. Pilot-From Port 3 Int. Pilot-From Port 5 External Pilot
MV-AXB-A331-FM-A51JA MV-AXB-A332-FM-A51JA MV-AXB-A341-FM-A51JA
DUAL PRESSURE VALVES
SOLENOID PILOT VALVE OPTIONS XX - XXYZZ XX PILOT EXHAUST
XX DC VOLTAGE
Y
MANUAL OPERATOR
ZZ EXTERNAL PLUG-IN
ZZ ENCLOSURE
FM Muffled exhaust FP Piped exhaust
A5 12 VDC (0.6 W) A6 24 VDC (0.6 W)
0 1 2 3 4
No operator Non-locking Recessed (std.) Locking Recessed Non-locking Extended Locking Extended
JA Square without light (on solenoid) JB Rectangular without light (on solenoid) JE Square without light (on body) JF Rectangular without light (on body)
AA JIC w/1/2" NPS Conduit BA Grommet CA Conduit 1/2" NPS CC Conduit 1/2" NPT (CSA Threads)
BASE TABLE ISO TYPE
PORT SIZE
INDIVIDUAL BASE BSPP NPTF
MANIFOLD BASE BSPP NPTF
ISO 1
1/4" 3/8"
MB-A1C-121 MB-A1C-131
MB-A1C-221 MB-A1C-231
MM-A1C-121 MM-A1C-131
MM-A1C-221 MM-A1C-231
ISO 2
3/8" 1/2"
MB-A2B-121 MB-A2B-131
MB-A2B-221 MB-A2B-231
MM-A2B-121 MM-A2B-131
MM-A2B-221 MM-A2B-231
ISO 3
1/2" 3/4"
MB-A3B-121 MB-A3B-131
MB-A3B-221 MB-A3B-231
MM-A3B-121 MM-A3B-131
N/A N/A
For manifold bases a common external pilot port is available. One connection only is required for all valves in the manifold whether single or double solenoid. Bottom ports are also available; consult factory for ordering information for these options. MANIFOLD FASTENING KIT, For each gang, one kit is required. To order specify par number N-63002-01.
351
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 28
OPTIONS Used on valve series: 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, MVA2B, MVA3B, MAC125, MAC250, MAC500.
Used on valve series: 200, 57, 58, 59.
1. VOLTAGE (200 Serie type coil)
1. VOLTAGE (100 Serie type coil) - XX Y
ZZ
VOLTAGE
- XX Y
ZZ
VOLTAGE
11
120/60, 110/50
11
120/60, 110/50, 24 VDC (6 W)
12
240/60, 220/50
12
240/60, 220/50
13
100/60, 100/50
13
100/60, 100/50
15
200/60, 200 /50
14
200/60, 200/50
16
10/60
20
6/60
20
6/60
21
12/60
21
12/50, 12/60
22
24/60, 24/50
22
24/60, 24/50
23
32/60, 32/50
23
32/60, 32/50
24
48/60, 42/50
24
48/60, 42/50
25
240/50
26*
380/50, 440/50, 440/60, 480/60
26
480/60, 440/50
29
220/60
27
127/60
34
127/50, 120/50
28
415/50
35
48/50
29
220/60
36
16/60
30
380/50
B1
24/50
31
550/60, 550/50
50
24 VDC (6 W)
32
120/60, 110/50
51
24 VDC (4 W)
33
600/60
54
12 VDC (4 W)
34
127/50
55
12 VDC (6 W)
35
48/50
57
12 VDC (2.5 W)
50
24 VDC (6 W)
59
24 VDC (2.5 W)
51
24 VDC (4.5 W)
60
12 VDC (8.5 W)
52
24 VDC (2.5 W)
61
24 VDC (8.5 W)
53
24 VDC (1.0 W)
64
6 VDC (6 W)
55
12 VDC (6 W)
65
32 VDC (7 W)
57
12 VDC (2.5 W)
66
48 VDC (5.8 W)
58
48 VDC (2.5 W)
67
64 VDC (7.5 W)
60
12 VDC (9.5 W)
68
120 VDC (6.4 W)
61
24 VDC (8.5 W)
69*
220 VDC (8.7 W), 250 VDC (11.2 W)
64
6 VDC (8.5 W)
75
90 VDC (8.8 W)
65
32 VDC (10 W)
76*
100 VDC (6.9 W)
66
48 VDC (11.5 W)
84*
125 VDC (10.9 W)
67
64 VDC (10.5 W)
87*
24 VDC (17.1 W)
68
120 VDC (12.3 W)
88*
12 VDC (17.4 W)
69
250 VDC (9.2 W)
89*
36 VDC (18.8 W)
71
8 VDC (8.2 W)
90
28 VDC (8.2 W)
72
24 VDC (12 W)
91*
6 VDC (10.6 W)
73
198 VDC (10 W)
92
190 VDC (6.5 W)
74
72 VDC (11.3 W)
94
3 VDC (7 W)
75
90 VDC (11.3 W)
95
38 VDC (6.4 W)
76
100 VDC (9 W)
A1
24 VDC (1 W)
77
220 VDC (10 W), 230 VDC (11.6 W)
A2
12 VDC (1 W)
78*
24 VDC (24 W)
A3
9 VDC (1 W)
80
55 VDC (10.6 W)
MOD. DD01 : Protection diode (DC) - MAX. 8.5W
82
170 VDC (11.1 W)
MOD. MOV1 : Protection varistor (AC) - MAX. 8.5W
83
15 VDC (8.1 W)
* Voltages are CLSF only
84
125 VDC (10 W)
86
36 VDC (11 W)
93*
12 VDC (24 W)
358
Consult “Precautions” page 364 before use, installation or service of MAC Valves
Page 29
O p t i o n
OPTIONS
2. MANUAL OPERATOR (Common options for 100 & 200 Series type coils) - XX Y
ZZ
MANUAL OPERATOR
0
No operator
5*
No Operator with Light
1
Non-locking recessed
6*
Non-Locking Recessed with Light
2
Locking recessed
7*
Locking Recessed with Light
3
Non-locking extended
8*
Non-Locking Extended with Light
4
Locking extended
9*
Locking Extended with Light
* Lights used with “AA” electrical connection 3. ELECTRICAL CONNECTION (100 Serie type coil) - XX Y
3. ELECTRICAL CONNECTION (200 Serie type coil)
ZZ
ELECTRICAL CONNECTION
ZZ
ELECTRICAL CONNECTION
AA
Wiring box with 1/2" NPS conduit
AA
Wiring box with 1/2" NPS conduit
BA
Flying leads
BA
Flying leads
CA
1/2" NPS conduit
CA
1/2" NPS conduit
CC
1/2" NPT conduit
CC
1/2" NPT conduit
FA
Military type 2 PIN
EA
Explosion proof (200 Series)
GA
Military type 3 PIN
EA
Explosion proof (57, 58 & 59 Series)
HA
AA with ground wire
FA
Military type 2 PIN
JA*
Square connector
GA
Military type 3 PIN
JB
Rectangular connector
HA
AA with ground wire
JC*
Square connector with light
JA*
Square connector
JD
Rectangular connector with light
JC
Square connector with light
JE
Square connector on top
JJ
Square connector, male only
(ISO2, ISO3)
NA
CA with ground wire
Rectangular connector on top
NC
CC with ground wire
JF
- XX Y
(ISO1, ISO2, ISO3) JG
JE with light
JH
JF with light
JJ
Square connector, male only
JM
Rectangular connector, male only
MA
Electrical common conduit (100 Series-Manifold/900 Series)
MB
Electrical common conduit (100 Series-Stacking/700 Series)
NA
CA with ground wire
NC
CC with ground wire
RA
3/8" NPS conduit
* Not to be used with 100, 800 and 900 Series manifold mounting
359
Consult “Precautions” page 364 before use, installation or service of MAC Valves s