Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Direct solenoid and solenoid pilot operated valves, Series ISO 3

Spec sheet · MAC Valves

Direct solenoid and solenoid pilot operated valves, Series ISO 3

Spec sheet29 pagesPDF 950 KB

Catalog pages for MAC Valves ISO 5599 spool valves, mainly Series ISO 3, with ordering codes, technical data, bases and options.

What this file really is

The old site listed this file as a spec sheet for the MAC Valves MV-A2B-A141-PM-111DA and MV-A2B-A341-PM-111DA. Filed as a spec sheet for the MV-A2B-A141 ISO 2 valve, but it is a MAC catalog section mostly about Series ISO 3 valves; the MV-A2B appears only as the ISO 2 size in the intrinsically safe ISO 1-2-3 pages and option lists.

Download the PDF950 KB

Filed with · 2 models

Also filed with these models on the old site

Summary

What is in it

Catalog section from MAC Valves covering ISO 5599 valves, mostly Series ISO 3: solenoid pilot operated plug-in and non plug-in valves, remote air valves, individual and manifold bases, with how-to-order model codes, operational benefits, technical data and metric dimensions. Later pages cover intrinsically safe ISO 1-2-3 valves (MV-A1C, MV-A2B and MV-A3B), where the ISO size is set in the model code, plus solenoid and electrical options that list the MVA2B series.

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

MAC Valves catalog pages for Series ISO 3 valves (ISO 5599/1 and 5599/2): solenoid pilot operated MV-B3A, MV-P3A and MV-A3B models, remote air operated MV-R3A and MV-A3B models, and the coil and connector option tables. It covers the ISO 3 size; the ISO 2 MV-A2B-A141-PM-111DA and MV-A2B-A341-PM-111DA it is filed under are not in it, and MV-A2B appears only as the ISO 2 size code. It gives ordering codes, technical data, dimensions, spare parts and piping notes.

Read for this summary: pages 1 to 8, 17 to 23 and 27 to 29 of 29.

Valve family
MAC Series ISO 3 valves, 5/2 and 5/3, 1/2" and 3/4" ports, delivered without base p. 1, 22
MV-A3B pilot air
MV-A3B pilot air models (MV-A3B-A141-PM-XXYZZ, MV-A3B-A341-PM-XXYZZ and others): solenoid pilot operated, 6.3 Cv, individual or manifold mounting p. 22
MV-A3B pilot pressure
MV-A3B pilot air: internal pilot 25-150 PSI (single operator, 3 positions) or 10-150 PSI (double operator); external pilot vacuum to 150 PSI p. 23
MV-A3B coil power
MV-A3B pilot air: inrush 14.8 VA, holding 10.9 VA; 1 to 17.1 W p. 23
MV-A3B response
MV-A3B pilot air, 24 VDC (8.5 W): energize 18 ms, de-energize 20 ms; 120/60: 15-25 ms and 19-28 ms p. 23
MV-A3B spare parts
MV-A3B pilot air: pilot valve PME-XXYZZ with seal 16337; valve-to-base seal 16436; mounting screws (x4) 35416; check valve 70002 (+M-00011) p. 23
Operating conditions
Compressed air, vacuum, inert gases; 40 µ filtration; 0°F to 120°F (-18°C to 50°C) p. 23
MV-A3B remote air
MV-A3B remote air models (MV-A3B-B141 and others): 6.3 Cv, vacuum to 150 PSI; spare remote air operator R-A3004 p. 18, 19
MV-B3A and MV-P3A
MV-B3A (non plug-in, ISO 5599/1) and MV-P3A (plug-in, ISO 5599/2): 1/2" 5.4 Cv, 3/4" 6.1 Cv; internal pilot 20 to 120 PSI p. 2, 3, 4
MV-B3A/MV-P3A response
MV-B3A and MV-P3A, 5.4 W coil: energize 16.2 ms, de-energize 13.6 ms p. 3
MV-B3A/MV-P3A spares
MV-B3A and MV-P3A: valve-to-base seal 16614; mounting screws (x4) 35451; pilot valve DMB-Dxxx-xxx (MV-P3A: DMB-DxxP-xxx) p. 3, 5
Coil options used on
One of the two coil option tables serves valve series 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, MVA2B, MVA3B, MAC125, MAC250, MAC500 p. 28
Voltage code 11
120/60, 110/50 (one of the two coil tables adds 24 VDC 6 W) p. 28
Manual operator codes
0 no operator, 1 non-locking recessed, 2 locking recessed, 3 non-locking extended, 4 locking extended p. 29

What this sheet walks you through

  • Ordering an ISO 3 valve by model code p. 2, 22
  • Choosing coil voltage, manual operator and electrical connection codes p. 17, 28, 29
  • Piping for external pilot, vacuum, selector and two-pressure applications p. 21
  • Dimensions of individual and manifold mountings p. 3, 23
  • Remote air operated ISO 3 valves p. 6, 7, 8

Good to know

  • An external pilot supply is needed only when main valve pressure is below 1.8 bar on single operators or 0.7 bar on double solenoid valves. p. 21
  • A coil above 30 volts needs a ground wire on flying-lead options. p. 17
  • Valve and base are ordered separately. p. 2
  • Lubrication is not required; if used, a medium aniline point lubricant is called for. p. 23
  • The catalog points to its Precautions page before use, installation or service. p. 1

Questions this sheet answers

What does MV-A2B mean in a MAC ISO valve model code?

The ISO size sits in the 5th position of the model code: MV-A1C is ISO 1, MV-A2B is ISO 2 and MV-A3B is ISO 3. p. 27

What pressure do MAC ISO 3 MV-A3B pilot air valves handle?

Internal pilot 25-150 PSI for single operator and 3-position valves or 10-150 PSI for double operator; external pilot vacuum to 150 PSI. p. 23

What does voltage code 11 mean on a MAC valve?

120/60, 110/50; one of the two coil tables also lists 24 VDC (6 W) under code 11. p. 28

When is an external pilot needed on a MAC ISO valve?

When the main valve pressure is below 1.8 bar on single operators, or 0.7 bar on double solenoid valves. p. 21

What is the flow of a MAC ISO 3 MV-A3B pilot air valve?

6.3 Cv for both 1/2" and 3/4" ports, at 6 bar with a 1 bar pressure drop. p. 23

The whole text · 3 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 2921-29

The file

Size and text

PublisherMAC Valves
Pages29
PDF950 KB
TextText from the PDF itself.

The first pages · 4 of 29

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 29
Page 2
Page 2of 29
Page 3
Page 3of 29
Page 4
Page 4of 29