6. BASE UNIT AND EXTENSION CABLE 6. 6.1

MELSEC-A

BASE UNIT AND EXTENSION CABLE Specifications This section describes the specifications for the base units (main base units, extension base units) that can be used in the system, and the application standards for extension base units.

6.1.1

Specifications of base units (1)

Specifications of main base units Table 6.1 Main base unit specifications

Model

A1S32B

A1S33B

A1S35B

A1S38B

Number of I/O modules

2 can be loaded

3 can be loaded

5 can be loaded

8 can be loaded

Extension connection

Enabled

Installation hole size

ø6-mm (0.24 in.) slot (for M5 screw)

External dimensions [mm(in.)]

220 × 130 × 28 (8.66 × 5.12 × 1.10)

255 × 130 × 28 (10.04 × 5.12 × 1.10)

325 × 130 × 28 (12.80 × 5.12 × 1.10)

430 × 130 × 28 (16.93 × 5.12 × 1.10)

Weight [kg(lb.)]

0.52 (1.14)

0.65 (1.43)

0.75 (1.65)

0.97 (2.13)

Accessory

Four mounting screws (M5 × 25)

Item

(2)

Specifications of extension base units Table 6.2 Extension base unit specifications

Model

A1S65B(S1)

A1S68B(S1)

A1S52B(S1)

A1S55B(S1)

A1S58B(S1)

Number of I/O modules

5 can be loaded

8 can be loaded

2 can be loaded

5 can be loaded

8 can be loaded

Power supply module loading

Required

Installation hole size

ø6-mm (0.24 in.) slot (for M5 screw)

Item

Not required

Terminal screw size

M4 × 6 (FG terminal)

Applicable wire size

0.75 to 2 mm

Applicable solderless terminal size

(V)1.25-4, (V)1.25-YS4, (V)2-YS4A (Applicable tightening torque: 98 to 137 N·cm [10 to 14 kg·cm] (56 to 79 lb/in.)

External dimensions mm(in.)

315 × 130 × 28 (12.40 × 5.12 × 1.10)

420 × 130 × 28 (16.54 × 5.12 × 1.10)

Weight kg(lb.)

0.71 (1.56)

0.95 (2.09)

Accessory

2

135 × 130 × 28 260 × 130 × 28 (5.31 × 5.12 × 1.10) (10.24 × 5.12 × 1.10)

365 × 130 × 28 (14.37 × 5.12 × 1.10)

0.38 (0.84)

0.87 (1.91)

0.61 (1.34)

*1 One dustproof cover (for I/O module) Four mounting screws (M5 × 25)

Four mounting screws (M5 × 25)

*1: For the installation of the dustproof cover, see Section 8.6.

POINT When using one of the base units A1S52B(S1), A1S55B(S1) or A1S58B(S1), which do not require a supply module, see Section 5.1.1 "Selection of the power supply module" and Section 6.1.3.

6-1

Page 93

6. BASE UNIT AND EXTENSION CABLE 6.1.2

MELSEC-A

Specifications of extension cables Table 6.3 shows the specifications of the extension cables which can be used for the AnSHCPU system. Table 6.3 Extension cable specifications Model

A1SC01B

A1SC03B

A1SC07B

A1SC12B

A1SC30B

A1SC60B

A1SC05NB A1SC07NB A1SC30NB A1SC50NB

Cable length [m (ft.)]

0.055 (0.18)

0.33 (1.08)

0.7 (2.3)

1.2 (3.94)

3.0 (9.84)

6.0 (19.68)

0.45 (1.48)

0.7 (2.3)

3.0 (9.84)

5.0 (16.14)

Resistance of 5 V DC supply line (Ω at 55 °C)

0.02

0.02

0.04

0.06

0.12

0.18

0.04

0.05

0.12

0.18

Item

Application

Connection between main base unit and A1S5[ ]B (S1)/A1S6[ ]B (S1)

Connection between main base unit and A5[ ]B/A6[ ]B

Connection between main base unit and A5[ ]B/A6[ ]B

Weight [kg (lb.)]

0.025 (0.055)

0.20 (0.44)

0.4 (0.88)

6.1.3

0.01 (0.022)

0.14 (0.31)

0.20 (0.44)

0.40 (0.88)

0.65 (1.43)

0.22 (0.48)

0.56 (1.23)

Application standards for extension base units (A1S52B(S1), A1S55B(S1), A1S58B(S1), A52B, A55B, A58B) When an extension base unit of one of the models A1S52B(S1), A1S55B(S1), A1S58B(S1), A52B, A55B, or A58B is used, make sure a voltage of 4.75 V or higher is supplied to the receiving end (at the module installed in the last slot of the extension base unit). With the A1S52B(S1), A1S55B(S1), A1S58B(S1), A52B, A55B, and A58B extension base units, 5 V DC is supplied from the power supply module of the main base unit via an extension cable. Therefore, some voltage drop occurs in the extension cable and the specified voltage may not be supplied to the receiving end, resulting in incorrect operation. If the voltage at the receiving end is less than 4.75 V, use an extension base unit of one of the models A1S65B(S1), A1S68B(S1), A62B, A65B, or A68B, equipped with a power supply module. (1)

Selection conditions The voltage received by the module installed in the last slot of an A1S52B(S1), A1S55B(S1), A1S58B(S1), A52B, A55B, or A58B extension base unit must be 4.75 V or higher. Since the output voltage of the power supply module is set at 5.1 V or higher, the voltage drop must be 0.35 V or less.

6-2

Page 94

6. BASE UNIT AND EXTENSION CABLE (2)

MELSEC-A

Factors of voltage drop Voltage drop may involve the following factors (a), (b), and (c) depending on the connecting method and type of extension base units. (a)

Voltage drop of a main base unit

(b)

Voltage drop of an extension base unit

(c)

Voltage drop in an extension cable

Extension cable connected to the left side Extension cable connected to the right side of main base of main base unit (serial) unit (parallel)

A1S3[ ]B

A1S52B(S1), A1S55B(S1), or A1S58B(S1) extension base unit is used

A1S3[ ]B (a)

(c)

A1S3[ ]B (a)

(c)

A1S5[ ]B(S1) (b)

(c) A1S5[ ]B(S1) (b)

Voltage drop of the main base unit can be ignored.

A1S3[ ]B

A5[ ]B

(c)

A52B, A55B or A58B extension base unit is used A5[ ]B

Voltage drop of the main and extension base units can be ignored.

6-3

Voltage drop of the extension base units can be ignored.

Page 95

6. BASE UNIT AND EXTENSION CABLE

MELSEC-A

(3)

Calculation of the receiving-end voltage

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

VCPU

V0

V1

V2

V3

V4

V5

V6

V7

V8

V9

V10

V11

V12

V13

V14

V15

ICPU

I0

I1

I2

I3

I4

I5

I6

I7

I8

I9

I10

I11

I12

I13

I14

I15

AnSH CPU

VCPU, V0 to V7 ICPU, I0 to I7 V8 to V15 I8 to I15 (a)

: Voltage drop of each slot of a main base unit : Current consumption of each slot of a main base unit : Voltage drop of each slot of an extension base unit : Current consumption of each slot of an extension base unit

Calculation of voltage drop of a main base unit (A1S32B, A1S33B, A1S35B, A1S38B) Each slot of a main base unit has a resistance of 0.007 Ω. Calculate the voltage drop of each slot, to obtain the total voltage drop of a main base unit. 1)

Voltage drop of a CPU module : VCPU VCPU = 0.007 × (0.4 + I0 + I1 + I2 + I3 + I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

2)

Voltage drop of slot 0 : V0 V0 = 0.007 × (I0 + I1 + I2 + I3 + I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

3)

Voltage drop of slot 1 : V1 V1 = 0.007 × (I1 + I2 + I3 + I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

4)

Voltage drop of slot 2 : V2 V2 = 0.007 × (I2 + I3 + I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

5)

Voltage drop of slot 3 : V3 V3 = 0.007 × (I3 + I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

6)

Voltage drop of slot 4 : V4 V4 = 0.007 × (I4 + I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

7)

Voltage drop of slot 5 : V5 V5 = 0.007 × (I5 + I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

8)

Voltage drop of slot 6 : V6 V6 = 0.007 × (I6 + I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

9)

Voltage drop of slot 7 : V7 V7 = 0.007 × (I7 + I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

10) Total voltage drop of a main base unit : VK VK = VCPU + V0 + V1 +V2 + V3 + V4 + V5 + V6 + V7)

6-4

Page 96

6. BASE UNIT AND EXTENSION CABLE (b)

MELSEC-A

Calculation of voltage drop of an extension base unit (A1S52B(S1), A1S55B(S1), A1S58B(S1)) Each slot of an extension base unit has a resistance of 0.006 Ω. Calculate the voltage drop of each slot, to obtain the total voltage drop of an extension base unit. 1)

Voltage drop of slot 8 : V8 V8 = 0.006 × (I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15)

2)

Voltage drop of slot 9 : V9 V9 = 0.006 × (I9 + I10 + I11 + I12 + I13 + I14 + I15)

3)

Voltage drop of slot 10 : V10 V10 = 0.006 × (I10 + I11 + I12 + I13 + I14 + I15)

4)

Voltage drop of slot 11 : V11 V11 = 0.006 × (I11 + I12 + I13 + I14 + I15)

5)

Voltage drop of slot 12 : V12 V12 = 0.006 × (I12 + I13 + I14 + I15)

6)

Voltage drop of slot 13 : V13 V13 = 0.006 × (I13 + I14 + I15)

7)

Voltage drop of slot 14 : V14 V14 = 0.006 × (I14 + I15)

8)

Voltage drop of slot 15 : V15 V15 = 0.006 × I15

9)

Total voltage drop of an extension base unit : VZ VZ = V8 + V9 + V10 +V11 + V12 + V13 + V14 + V15

(c)

Calculation of voltage drop in extension cables [1]

Total current consumption of an extension base unit : IZ IZ = I8 + I9 + I10 + I11 + I12 + I13 + I14 + I15

[2]

Voltage drop in an extension cable : VC VC = (Resistance of an extension cable) × IZ Resistance of extension cables A1SC01B ..... 0.02 Ω A1SC03B ..... 0.021 Ω A1SC07B ..... 0.036 Ω A1SC12B ..... 0.055 Ω

(d)

A1SC30B ..... 0.121 Ω A1SC60B ..... 0.182 Ω A1SC05NB ... 0.037 Ω A1SC07NB ... 0.045 Ω

Voltage at the receiving end (5.1 (V) - VK - VZ - VC) ≥ 4.75 (V)

6-5

Page 97

6. BASE UNIT AND EXTENSION CABLE (4)

MELSEC-A

Examples

A1SX40

A1SX40

A1SX40

A1SX40

A1SX40

A1SX40

A1SX40

A1SX40

A1S62P

A1SHCPU

A1S38B

A1S03B (0.021 Ω)

(a)

A1SY40

A1SY40

A1SY40

A1SY40

A1SY40

A1SY40

A1SY40

A1SY40

A1S58B

Calculation of voltage drop of the main base unit VK = 0.007 × {0.4 + 0.05 × (8 + 7 + 6 + 5 + 4 + 3 + 2 + 1) + (0.27 × 8) × 8} = 0.13636

(b)

Calculation of voltage drop of the extension base unit VZ = 0.006 × 0.27 × (8 + 7 + 6 + 5 + 4 + 3 + 2 + 1) = 0.05832

(c)

Calculation of voltage drop in the extension cable VC = 0.036 × (0.27 × 8) = 0.07776

(d)

Voltage at the receiving end 5.1 - 0.13636 - 0.05832 - 0.07776 = 4.82756 (V) Since the voltage at the receiving end is more than 4.75 V, the system can be put into operation.

(5)

Minimizing the voltage drop Try the following measures to minimize the voltage drop : (a)

Change the positions of modules. Install the modules of the main base unit from slot 0 in descending order of current consumption. Install modules with small current consumption in the extension base units.

(b)

Connect the base units in series. By connecting the base units in series (connecting an extension cable to the left side of a main base unit, see Section 8.4.2), the voltage drop of the main base unit can be minimized. But when a long extension cable is used for this connection, the extension cable may cause a larger voltage drop than that of the main base unit. In such case, calculate the voltage drop as described in (3).

(c)

Use a short extension cable. The shorter the extension cable, the lower and the smaller its voltage drops. Use extension cables that are as short as possible.

6-6

Page 98

6. BASE UNIT AND EXTENSION CABLE 6.2

MELSEC-A

Nomenclature and Settings (1)

Main base unit (A1S32B, A1S35B, A1S38B)

(4)

(5)

(1) (1)

IOUT

IOUT

CPU

I/O

0

I/O

1

I/O

2

I/O

3

I/O

4

I/O

5

POWER

I/O

6

I/O

7

A1S38B

(2) (2)

(3)

(6)

No.

Name

Application

(1)

Connector for extension cable Connector for sending and receiving signals to and from the extension base unit.

(2)

Base cover

Cover to protect the connector for the extension cable. When connecting an extension cable, remove the appropriate base cover located below the word "OUT" with nippers or a similar tool.

(3)

Module connectors

Connectors where the power supply module, CPU module, I/O module, special function modules are loaded. Fit the connector cover or blank cover (A1SG60) to vacant connectors, in order to protect the module from dust.

(4)

Module fixing screw

Screw to fix a module to the base unit. Screw size : M4 × 12 screw

(5)

Guide hole for base installation

Slot for mounting this base unit to the panel of control box, etc. (For M5 screw)

(6)

DIN rail hook

Hook to install on a DIN rail. A1S32B, A1S33B ....... 1 A1S35B, A1S38B ....... 2

6-7

Page 99

6. BASE UNIT AND EXTENSION CABLE (2)

MELSEC-A

Main base modules (A1S52B(S1), A1S55B(S1), A1S58B(S1), A1S65B(S1), A1S68B(S1))

A1S65B (S1), A1S68B (S1) (5)

(4)

(2)

IN

OUT

OUT

I/O

0

I/O

1

I/O

2

I/O

3

I/O

4

I/O

5

I/O

6

POWER

I/O

7

A1S68B

(2)

(9)

(3)

(6)

(1)

A1S52B (S1), A1S55B (S1), A1S58B (S1) (5)

IN

(4)

(2)

OUT

OUT

I/O

0

I/O

1

I/O

2

I/O

3

I/O

4

I/O

5

6

I/O

I/O

7

A1S58B

FG

(1) (7)

No.

(3)

(6)

Name

Purpose Used to connect an extension cable to a main base module. Remove the connector cover attached to the module and connect the extension cable.

(1)

Extension cable connector

(2)

Base cover

Extension cable connector protective cover.

(3)

Module connector

Used to load a power supply module, I/O or special function module. Put a supplied cover or blank cover (A1SG60) on any unused connector to protect it from dust.

(4)

Module fixing screw

Used to secure a module to the base module. Screw size : M4 × 12

(5)

Base mounting hole

Used to mount the base module to a control panel. (for M5 screw)

(6)

DIN rail hook

Used to install on a DIN rail. A1S52B(S1), A1S55B(S1) : One hook A1S65B(S1), A1S68B(S1), A1S58B(S1) : Two hooks

(7)

FG terminal

Grounding terminal connected to the shield pattern on the PC board.

6-8

Page 100

6. BASE UNIT AND EXTENSION CABLE 6.3

MELSEC-A

Installing on a DIN Rail Both main base units and extension base units are equipped with hooks for mounting on a DIN rail. The method for mounting them on a DIN rail is explained below : (1)

Applicable DIN rails (JIS-C2B12) TH35-7.5 Fe TH35-7.5 Al TH35-15 Fe

(2)

Mounting screw interval When a TH35-7.5 Fe or TH35-7.5 Al rail is mounted, fix it with screws spaced no more than 200 mm (7.87 in.) apart.

DIN rail

Mounting screw

35 mm (1.38 in.)

P

P

P

P=200 mm (7.87 in.) or less

6-9

Page 101

6. BASE UNIT AND EXTENSION CABLE (3)

MELSEC-A

Mounting/removing on/from a DIN rail (a)

Mounting procedure Mount a base unit on a DIN rail as follows : 1)

Engage the hook of the base unit with the rail from above rail.

2)

Push the base unit onto the rail and fix it in position.

Module

DIN rail hook

DIN rail

Base unit

Modules mounted to DIN rail

(b)

Removing procedure Remove a base unit from the DIN rail as follows : 1)

Pull down the bottom hook of the base unit using a flat blade screwdriver.

2)

Pull the base unit away from the rail while pulling down the bottom hook.

Module

Base unit

Pull to remove Bottom hook

6 - 10

Flat blade screwdriver