AnS(H) CPU User's Manual: APPENDICES, pages 157 to 166

Pages 157 to 166 of 242, from AnS(H) CPU User's Manual

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Mitsubishi A1S38

Page 157

APPENDICES

MELSEC-A

APPENDICES Appendix 1 Instructions Instructions used with the AnSHCPU are listed below. See the following programming manuals for details of the instructions. • ACPU Programming Manual (Fundamentals) • ACPU Programming Manual (Common Instructions) • AnSHCPU/AnACPU/AnVCPU Programming Manual (Dedicated Instructions)

(1)

(IB-66249) (IB-66250) (IB-66251)

Sequence instructions (a)

Contact instruction Contact

(b)

LD, LDI, AND, ANI, OR, ORI

Connection instruction Connection

(c)

ANB, ORB, MPS, MRD, MPP

Output instruction Output

(d)

OUT, SET, RST, PLS, PLF, CHK

Shift instruction Shift

(e)

SFT, SFTP

Master control instruction Master control

(f)

MC, MCR

Termination instruction Program end

(g)

FEND, END

Other instructions Stop

STOP

No operation

NOP

Page feed (page feed operation of printer output)

NOPLF

APP - 1

Page 158

APPENDICES

MELSEC-A (2)

Basic instructions (a)

Comparison instructions 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits

= <> > <= < >=

(b)

BIN arithmetic operation instructions 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits

+ Addition - Subtraction * Multiplication / Division +1 Addition -1 Subtraction

(c)

BCD 4 digits BCD 8 digits BCD 4 digits BCD 8 digits BCD 4 digits BCD 8 digits BCD 4 digits BCD 8 digits

- Subtraction * Multiplication / Division

Two types each for B+ and B+P Two types each for DB+ and DB+P Two types each for B- and B-P Two types each for DB- and DB-P B*, B*P DB*, DB*P B/, B/P DB/, DB/P

BCD - BIN conversion instructions BIN → BCD BCD → BIN

(e)

Two types each for + and +P Two types each for D+ and D+P Two types each for - and -P Two types each for D- and D-P *, *P D*, D*P /, /P D/, D/P INC, INCP DINC, DINCP DEC, DECP DDEC, DDECP

BCD arithmetic operation instructions + Addition

(d)

LD=, AND=, OR= LDD=, ANDD=, ORD= LD<>, AND<>, OR<> LDD<>, ANDD<>, ORD<> LD>, AND>, OR> LDD>, ANDD>, ORD> LD<=, AND<=, OR<= LDD<=, ANDD<=, ORD<= LD<, AND<, OR< LDD<, ANDD<, ORD< LD>=, AND>=, OR>= LDD>=, ANDD>=, ORD>=

16 bits 32 bits 16 bits 32 bits

BCD, BCDP DBCD, DBCDP BIN, BINP DBIN, DBINP

16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 16 bits

MOV, MOVP DMOV, DMOVP XCH, XCHP DXCH, DXCHP CML, CMLP DCML, DCMLP BMOV, BMOVP FMOV, FMOVP

Data transfer instructions Transfer Change Undefined transfer Block transfer Repeat data block transfer

APP - 2

Page 159

APPENDICES

MELSEC-A (f)

Program branch instructions Jump Subroutine call Interrupt program enable/disable Microcomputer program call

(g)

CJ, SCJ, JMP CALL, CALLP, RET EI, DI, IRET SuB

Refresh instructions Link refresh Link refresh enable/disable Partial refresh

(3)

COM EI, DI SEG

Application instructions

(a)

Logical operation instructions Logical product Logical product Exclusive logical sum NOT exclusive logical sum 2's complement (reversed sign)

(b)

Left ward rotation

Left ward shift

NEG, NEGP

16 bits 32 bits 16 bits 32 bits

ROR, RORP, RCR, RCRP DROR, DRORP, DRCR, DRCRP ROL, ROLP, RCL, RCLP DROL, DROLP, DRCL, DRCLP

16 bits Per device 16 bits Per device

SFR, SFRP, BSFR, BSFRP DSFR, DSFRP SFL, SFLP, BSFL, BSFLP DSFL, DSFLP

Data processing instructions Data search Bit check

Decode Encode Bit set Bit reset Dissociation Association

(e)

16 bits

Shift instructions Right ward shift

(d)

Two types each for WAND and WANDP DAND, DANDP Two types each for WOR and WORP DOR, DORP Two types each for WXOR and WXORP DXOR, DXORP Two types each for WXNR and WXNRP DXNR, DXNRP

Rotation instructions Right ward rotation

(c)

16 bits 32 bits 16 bits 32 bits 16 bits 32 bits 16 bits 32 bits

16 bits 16 bits 32 bits 2.MDSU/n. MDNM/ bits 16 bits 2.MDSU/n. MDNM/ bits 16 bits 16 bits 16 bits 16 bits

SER, SERP SUM, SUMP DSUM, DSUMP

BSET, BSETP BRST, BRSTP DIS, DISP UNI, UNIP

16 bits 16 bits

FIFW, FIFWP FIFR, FIFRP

DECO, DECOP SEG ENCO, ENCOP

FIFO instructions Write Read

APP - 3

Page 160

APPENDICES

MELSEC-A (f)

ASCII instructions ASCII conversion ASCII print

(g)

Buffer memory access instructions 1 word 2 words 1 word 2 words

Data read Data write

(h)

ASC Two types each for PR and PRC

FOR NEXT instruction Repetition

(i)

FOR, NEXT

Data link module instruction Data read Data write

(j)

1 word 1 word

LEDR

Other instructions WDT reset Fault check Status latch Sampling trace Carry flag set/reset Timing clock

(4)

LRDP, RFRP LWTP, RTOP

Display instruction Display reset

(k)

FROM, FROMP DFRO, DFROP TO, TOP DTO, DTOP

1 bit 1 bit

WDT, WDTP CHK SLT, SLTR STRA, STRAR STC, CLC DUTY

CC-Link dedicated instructions Link parameter setting Refresh parameter setting Read master station buffer memory Write to master station buffer memory Read buffer memory of intelligent remote station Write to buffer memory of intelligent remote station Write to buffer memory of intelligent remote station (with handshaking) Read buffer memory of intelligent remote station (with handshaking) Read to the word station link register Write to the word station link register Monitor the word station link register

APP - 4

RLPA RRPA RIFR RITO RIRD RIWT RISEND RIRCV RDGET RDPUT RDMON

Page 161

APPENDICES

MELSEC-A

Appendix 1.1 CC-Link Dedicated Instructions The instructions dedicated to CC-Link are designed to make automatic refresh setting for the AnSHCPU and master module/local module and to make data communication with a remote station connected to CC-Link. There are 11 different CC-Link dedicated instructions as indicated in Table 1. Table 1 CC-Link dedicated instruction list

Classification

Instruction name

Description

Instruction execution stations

Stations connected to CC-Link

Refer to

M

L

M

L

ID

RD

Network parameter setting

RLPA

Sets the network parameters to the master module of CC-Link.

ϒ

×

×

×

×

×

App 1.1.2

Automatic refresh parameter setting

RRPA

Sets the automatic refresh parameters to the master/local module of CC-Link.

ϒ

ϒ

×

×

×

×

App 1.1.3

Read from automatic updating buffer memory RIFR

Reads the specified points of data from the automatic updating buffer memory of the master/local module.

ϒ

ϒ

×

×

×

×

App 1.1.4

Write to automatic updating buffer memory RITO

Writes the specified points of data to the automatic updating buffer memory of the master/local module.

ϒ

ϒ

×

×

×

×

App 1.1.5

Read from remote device station buffer memory

RIRD

Reads the specified points of data from the specified buffer memory of the remote device station.

ϒ

ϒ

ϒ

ϒ

ϒ

×

App 1.1.6

Write to remote device station buffer memory

RIWT

Writes the specified points of date to the specified buffer memory of the remote device station.

ϒ

ϒ

ϒ

ϒ

ϒ

×

App 1.1.7

RIRCV

Reads the specified points of data from the specified buffer memory of the intelligent device station. Handshake is performed using a handshake signal.

ϒ

×

×

×

ϒ

×

App 1.1.8

Write intelligent device station buffer memory (with handshake)

RISEND

Writes the specified points of data to the specified buffer memory of the intelligent device station. Handshake is performed using a handshake signal.

ϒ

×

×

×

ϒ

×

App 1.1.9

Read from remote device station

RDGET

Reads data from a remote device station.

ϒ

×

×

×

×

ϒ

App 1.1.10

Write to remote device station

RDPUT

Writes data to a remote device station.

ϒ

×

×

×

×

ϒ

App 1.1.11

Remote device station monitoring

RDMON

Monitors a remote device station.

ϒ

×

×

×

×

ϒ

App 1.1.12

Read from intelligent device station buffer memory (with handshake)

REMARKS 1) "M", "L", "ID" and "RD" in Table 1. denote the following : • M : Master station • L : Local station • ID : Intelligent device station • RD : Remote device station 2)

In the "Instruction Execution Stations" and "Object Stations" fields of Table 1, ϒ denotes that the corresponding station is available and × unavailable. However, since the availability of the dedicated instructions in Table 1 changes with the module of the station connected to CC-Link, refer to the manual of the module used to confirm the availability.

APP - 5

Page 162

APPENDICES Instructions for use of the CC-Link dedicated instructions (1)

Different intelligent device stations have different buffer memory capacities. Refer to the manual of the intelligent device station used.

(2)

Only one of the RIRD, RIWT, RISEND and RIRCV instructions may be executed for the same station. If two or more of the RIRD, RIWT, RISEND and RIRCV instructions are executed, the second and subsequent instructions are ignored.

(3)

RDGET, RDPUT and RDMON may be executed for the same station separately. Any of these instructions cannot be executed in two or more locations for the same station. If any of RDGET, RDPUT and RDMON instructions is used in two or more places, the second and subsequent instructions are ignored.

(4)

RIRD, RIWT, RISEND, RIRCV, RDGET, RDPUT and RDMON may be executed for different stations at the same time. Note that up to 64 instructions may be executed simultaneously.

(5)

The data of any devices used by the CC-Link dedicated instruction should not be changed until the completion of the instruction. If the data of the device is changed during execution of the instruction, the CC-Link dedicated instruction cannot be completed properly.

(6)

Specify the head I/O number of the master/local module in the CC-Link dedicated instruction. This head I/O number of the master/local module is the value in the upper 2 digits of the master/local module's I/O number represented in 3 digits. For example, when the master/local module's I/O number is X/Y120, the head I/O number is 12H. Power supply module

1.1.1

MELSEC-A

A n S H C P U

A 1 S X 42

A 1 S X 42

A 1 S Y 42

A 1 S Y 42

A 1 S Y 41

A 1 S J 61 B T 11

X00

X40

X80

YC0

Y100

120 to to to to to to

X3F

X7F

XBF

YFF

Y11F

13F

I/O number

Head I/O number : 12H

APP - 6

Page 163

APPENDICES

X

Y

M

L

S

B

F

T

C

D W R A0 A1 Z

V

Constant

Pointer Levle

K

P

H

I

N

Index

Word device

Subset

Available device Bit device

Number of steps

Network parameter setting .......... RLPA Digit designation

1.1.2

MELSEC-A

Carry flag Error flag M9012

M9011 n 23

D1 D2

Command LEDA/LEDB

RLPA

SUB n

LEDC

D1

LEDC

D2

LEDA·······Executed while ON LEDB·······Executed at leading edge LEDC······ Device number designated SUB·········Constant designated

LEDR

Network Parameter Data

(1)

Data to be set n

Head I/O number of object master module

D1

Head number of devices which stores link parameters

D2

Host station's bit device number which is switched on on completion of execution

Network parameter setting items D1 +0

Synchronous mode valid/invalid

D1 +1

Number of stations connected for communication

D1 +2

Slave station setting information to

Set values for the number of stations connected for communication.

Slave station setting information Sending buffer size Receiving buffer size to

Set values for one local/intelligent device station.

Automatic buffer size to Sending buffer size Receiving buffer size D1 +n

(2)

Automatic buffer size

Number of points required for the network parameter area The following points are required for the network parameter setting : • Synchronous mode...........1 point valid/invalid setting • Communication station .....1 point count setting • Slave station setting..........Number of points for the number of slave information stations connected for communication • Sending buffer size ...........Number of points for the number of local and intelligent device stations • Receiving buffer size ........Number of points for the number of local and intelligent device stations • Automatic update..............Number of points for the number of local buffer size and intelligent device stations

APP - 7

Page 164

APPENDICES

MELSEC-A (3)

Network parameter settings

Item Synchronous mode valid/invalid

Number of stations connected for communication

Setting range

Setting end

Set whether the synchronous mode is valid or invalid. • When synchronous mode is valid : 0 • When synchronous mode is invalid : 1

Set data

0/1

User

Set the number of slave stations connected to the master module of CC-Link.

1 to 64

User

Set the slave station type, number of slave stations occupied, and station number as indicated below : b15 to b12 b11 to b8 b7 to b0, Station number Number of slave stations occupied Slave station type

Slave station setting information b0 to b7 1 to 64 (1H to 40H)

• Station number setting 1 to 64 (Setting with BIN)

User

• Set the number of slave stations occupied Number of slave stations occupied

Setting

1 station

1

2 station

2

3 station

3

4 station

4 b8 to b11 1 to 4

• Slave station type setting Slave station type

Setting

Remote I/O station

0

Remote device station

1

Local station

2 b12 to b15 0 to 2

Intelligent device station

Sending buffer size

Set the number of points transmitted from the master station to a local/intelligent device station.

*

User

Receiving buffer size

Set the number of points transmitted from a local/intelligent device station to the master station.

*

User

Automatic updating buffer size

Set the number of points of the automatic updating buffer used by the master station and local/intelligent device station.

*

User

* : To be set in response to the module used.

APP - 8

Page 165

APPENDICES Functions

MELSEC-A (1)

When the RLPA instruction is executed, the network parameter data set to the devices beginning with the one specified at D1 is set to the master module specified at n . AnSHCPU

Master module n

D1 +0

Network parameter data to

Network parameter setting

Network parameters

D1 +n

(2)

When the slave station type specified is a local/intelligent device station, it is necessary to set the "sending buffer size", "receiving buffer size" and "automatic updating buffer size". When the slave station type is a remote I/O station or a remote device station, it is not necessary to set the "sending buffer size", "receiving buffer size" and "automatic updating buffer size". Local station Remote I/O station Remote device station Intelligent device station Sending buffer size Receiving buffer size Automatic buffer size Sending buffer size Receiving buffer size Automatic buffer size

Sending buffer size, receiving buffer size and automatic buffer size need not be set. Set sizes for local and intelligent device stations successively. For remote I/O and remote device stations, their buffer sizes are not set. When setting for the other stations, therefore, start setting with the frontmost empty position.

(3)

After setting of the network parameters, if the RLPA instruction is executed again during RUN to change the network parameters, new data is not used for communication with the slave stations. When the AnSHCPU is switched to STOP/PAUSE, then to RUN, the new network parameters are used for communication with the slave stations.

APP - 9

Page 166

APPENDICES Execution Conditions

MELSEC-A As shown below, when the LEDA instruction is used, the RLPA instruction is executed every scan while the write command is ON. When the LEDB instruction is used, the RLPA instruction is executed only one scan on the leading edge (OFF → ON) of the write command. Instruction Execution Step 0

Instruction Execution END

Step 0

Instruction Execution END

Step 0

Instruction Execution END

Step 0

Instruction Execution END

Step 0

Sequence program flow ON

Write command

OFF

RLPA (with LEDA)

RLPA (with LEDB)

Program Example

The following program sets the network parameters to the master module of CCLink allocated to I/O numbers 000 to 01F. (1)

Network parameter settings Set item

Set data

Device for storing data

Synchronous mode valid/invalid setting

Synchronous mode

1

D1000

Communication station count setting

1 module

1

D1001

Slave station type

Intelligent device station

2

Number of slave stations occupied

1 station

1

1

1

Slave station setting information

Station number

D1002

Sending buffer size

128 (80H) words

D1003

Receiving buffer size

128 (80H) words

D1004

Automatic buffer size

960 (600H) words

D1005

2)

Program

0

X0020

P H 0001

D1000

Synchronous mode valid setting

P H MOV 0001

D1001

Setting of number of communication stations

MOV

P H 2101

D1002

Setting of slave station setting information

MOV

P H 0080

D1003

Setting of sending buffer size

P H MOV 0080

D1004

Setting of receiving buffer size

P H MOV 0600

D1005

Setting of automatic updating buffer size

MOV

LEDB

RLPA SUB

K 0

LEDC D1000 LEDC L1000 LEDR

APP - 10

Designation of RLPA instruction