Summary
What is in it
Mitsubishi Electric's user's manual for building block type I/O modules of the MELSEC-A series. It gives general specifications and selection notes, then a specification page for each AX input module (including the AX41 and AX42) and each AY output module (including the AY42, AY51 and AY81), the A42XY and AH42 composite modules, connector/terminal block converter modules, the AG60 blank cover, AG62 dummy module and simulation switches, nomenclature, I/O wiring troubleshooting and dimensions. The text is OCR.
Its parts
- 1. Notes on Selecting the I/O Modules
- 2. Input Module Specification
- 3. Output Module Specifications
- 4. I/O Composite Module Specifications
- 5. Specifications of Connector/Terminal Block Convertor Modules
- 6. Blank Cover, Dummy Module, Simulation Switch Specifications
- 7. Nomenclature
- 8. I/O Connection Troubleshooting
- Appendix
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Mitsubishi MELSEC-A user's manual IB(NA)66140, Version E, for building block type I/O modules. It gives general specifications and selection notes, the specifications of the AX input and AY output modules, composite and converter modules, the AG60 blank cover, AG62 dummy module and simulation switches, and I/O wiring troubleshooting. The whole manual is a scan read by OCR, so its text has many errors.
- What it is
- Mitsubishi MELSEC-A building block type I/O module p. 1, 8
- Operating temperature
- 0 to 50 C p. 12
- Storage temperature
- -20 to 75 C p. 12
- Humidity
- 10 to 90 % RH, non-condensing p. 12
- Shock resistance
- 147 m/s2 (15G), 3 times in each of 3 directions p. 12
- Altitude
- 2000 m (6562 ft) max. p. 12
- AG62 dummy module
- Reserves 16, 32, 48 or 64 I/O points in a base unit slot for future use p. 92
- AG62 setting
- DIP switches SW1 and SW2 on the front; factory-set to 64 points p. 92
- AG62 simulation
- First 16 inputs can be simulated with its DIP switches; 70 mA at 5 VDC p. 92
- AX42 connection
- Two 40-pin solder connectors, 0.3 mm2 (23 AWG) wire; 120 mA at 5 V DC p. 29
- AY42 output
- 64 sink transistor outputs, 12/24 V DC, 0.1 A per point, 2 A per common p. 63
- AY42 power
- Load range 10.2 to 40 V DC; 340 mA at 5 V DC with all points on p. 63
- Flat cable connector
- FCN-367J040-AU/F jack for AX42/AY42 pressure displacement wiring (user supplied) p. 15
What this manual walks you through
- Derating simultaneous ON points by voltage and temperature p. 13
- Choosing triac rather than relay outputs p. 13
- When on-board fuses protect outputs, and external fuses p. 14
- Setting the AG62 dummy module's occupied I/O points p. 92, 96
- Testing programs with the A6SW16 and A6SW32 simulation switches p. 93
- Fixing inputs that do not turn off because of leakage current p. 102, 103, 104
- Output wiring troubleshooting p. 105, 106
Good to know
- Inductive loads must stay on and off for more than one second each. p. 13
- Watch for rush current when an AY40, AY41 or AY42 switches a load containing a DC/DC converter. p. 13
- On the AY42 the load supply and external supply must be the same, or the clamp diode surge suppression does not work. p. 63
- Next to the power supply module the AX42 allows only 40% of inputs on at once. p. 29
- Next to the power supply module the AY42 common rating drops to 1.6 A. p. 63
Questions this manual answers
What is the Mitsubishi AG62 used for?
It is a dummy module that reserves I/O points (16, 32, 48 or 64) in a base unit slot for future use. p. 92
How do I set the number of points on an AG62?
With the DIP switches on the module front; it comes set to 64 points. p. 92
How many inputs does the AX42 have?
64 sink-type DC inputs at 12/24 V DC, wired through two 40-pin connectors. p. 29
What flat cable connector fits the AX42 or AY42?
The user supplies an FCN-367J040-AU/F pressure displacement connector jack. p. 15
What current can each AY42 output switch?
0.1 A per point, up to 2 A per common (1.6 A next to the power supply). p. 63
Contents
Chapters and sections
Each line opens the PDF at its page.
- Cover1
- SAFETY PRECAUTIONS2
- REVISIONS7
- INTRODUCTION8
- 1. NOTES ON SELECTING THE I/O MODULES12
- 2. INPUT MODULE SPECIFICATION18
- 2.1 Type AX10 Input Module19
- 2.2 Type AX11 Input Module20
- 2.3 Type AX20 Input Module22
- 2.4 Type AX21 Input Module23
- 2.5 Type AX31 12/24V DC/AC Input Module25
- 2.6 Type AX40 Input Module (Sink Loading)26
- 2.7 Type AX41 Input Module (Sink Loading)27
- 2.8 Type AX41-S1 Input Module (Sink Loading)28
- 2.9 Type AX42 Input Module (Sink Loading)29
- 2.10 Type AX42-S1 Input Module (Sink Loading)30
- 2.11 Type AX50 Input Module (Sink Loading)31
- 2.12 Type AX50-S1 Input Module (Sink/Source)32
- 2.13 Type AX60 Input Module (Sink Loading)33
- 2.14 Type AX60-S1 Input Module (Sink/Source Loading)34
- 2.15 Type AX70 Input Module (Sink/Source)35
- 2.16 Type AX71 Input Module (Sink/Source)36
- 2.17 Type AX80 Input Module (Source Loading)37
- 2.18 Type AX80E Input Module (Source Loading)38
- 2.19 Type AX81 Input Module (Source Loading)39
- 2.20 Type AX81-S1 Input Module (Sink/Source Loading)40
- 2.21 Type AX81-S2 Input Module (Source Loading)41
- 2.22 Type AX82 Input Module (Source Loading)42
- 3. OUTPUT MODULE SPECIFICATIONS43
- 3.1 Type AY10 Output Module44
- 3.2 Type AY10A Output Module (Relay Contact Output (all points independent))45
- 3.3 Type AY11 Output Module46
- 3.4 Type AY11A Output Module (Relay Contact Output (all points independent))47
- 3.5 Type AY11E Output Module49
- 3.6 Type AY13 Output Module51
- 3.7 Type AY13E Output Module53
- 3.8 Type AY22 Output Module56
47 more lines, from page 57 on
- 3.9 Type AY23 Output Module57
- 3.10 Type AY40 Output Module (Sink Loading)58
- 3.11 Type AY40A Output Module (Sink Loading, all points independent)59
- 3.12 Type AY40P Transistor Output Module (Sink Loading)60
- 3.13 Type AY41 Output Module (Sink Loading)61
- 3.14 Type AY41P Transistor Output Module (Sink Loading)62
- 3.15 Type AY42 Output Module (Sink Loading)63
- 3.16 Type AY42-S1 Output Module (Sink Loading)64
- 3.17 Type AY42-S3 Transistor Output Module (Sink Loading)65
- 3.18 Type AY42-S4 Transistor Output Module (Sink Loading)66
- 3.19 Type AY50 Output Module (Sink Loading)67
- 3.20 Type AY51 Output Module (Sink Loading)68
- 3.21 Type AY51-S1 Transistor Output Module (Sink Loading)69
- 3.22 Type AY60 Output Module (Sink Loading)70
- 3.23 Type AY60S Output Module (Sink Loading)71
- 3.24 Type AY60E Output Module (Sink Loading)72
- 3.25 Type AY60EP Output Module (Source Loading, Circuit protection provided)73
- 3.26 Type AY70 Output Module (Sink Loading)74
- 3.27 Type AY71 Output Module (Sink Loading)75
- 3.28 Type AY72 Transistor Output Module (For TTL, CMOS; Sink Loading)76
- 3.29 Type AY80 Output Module (Source Loading)77
- 3.30 Type AY80EP Output Module (Source Loading, Circuit protection provided)78
- 3.31 Type AY81 Output Module (Source Loading)79
- 3.32 Type AY81EP Output Module (Source Loading, Circuit protection provided)80
- 3.33 Type AY82EP Output Module (Source Loading, Circuit protection provided)81
- 4. I/O COMPOSITE MODULE SPECIFICATIONS82
- 5. SPECIFICATIONS OF CONNECTOR/TERMINAL BLOCK CONVERTOR MODULES87
- 6. BLANK COVER, DUMMY MODULE, SIMULATION SWITCH SPECIFICATIONS92
- 7. NOMENCLATURE94
- 8. I/O CONNECTION TROUBLESHOOTING102
- APPENDIX107
- Backcover120
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 61-6
- Pages 7 to 117-11
- 1. NOTES ON SELECTING THE I/O MODULES12-17
- 2. INPUT MODULE SPECIFICATION, pages 18 to 2618-26
- 2. INPUT MODULE SPECIFICATION, pages 27 to 3527-35
- 2. INPUT MODULE SPECIFICATION, pages 36 to 4236-42
- 3. OUTPUT MODULE SPECIFICATIONS, pages 43 to 5243-52
- 3. OUTPUT MODULE SPECIFICATIONS, pages 53 to 6253-62
- 3. OUTPUT MODULE SPECIFICATIONS, pages 63 to 7263-72
- 3. OUTPUT MODULE SPECIFICATIONS, pages 73 to 8173-81
- 4. I/O COMPOSITE MODULE SPECIFICATIONS82-86
- 5. SPECIFICATIONS OF CONNECTOR/TERMINAL BLOCK CONVERTOR MODULES87-91
- Pages 92 to 10192-101
- 8. I/O CONNECTION TROUBLESHOOTING102-106
- Pages 107 to 120107-120
The file