Page 1
SUBS
MELSEC F-12R, F-20M Programmable Controller INSTRUCTION MANUAL saan same ® This manual provides technical information and guidance on the installation and use of the Mitsubishi F-12R and F-20M Programmable Controller and its extension unit.
@ Users should ensure that the detail of this manual is studied and understood before attempting to instal or use the units.
® Information concerning the programming of the system, using the F-20P-E programmer unit, is covered in a separate manual.
‘fa MITSUBISHI ELECTRIC CORPORATION
Page 2
Contents
. Input Handling
6-1 Sink Input Type... ee 6-2 Source Input Type 0... 0. ee ee . Output Handling
7-1] Relay Output Type... 2... ee ee 7-2 SSR Output Type... 2... ee es 7-3 Transistor Output Type... . 0.0. ke ee ee
. Maintenance and Diagnostics ........... 000 esas naan
. Outlines and Specifications... ...... 0.00 eee ee
Page 3
THE MITSUBISHI F SERIES PC RANGE
The Mitsubishi F series of programmable controllers and auxiliary equipments are of compact size and light weight, and are ideal for small industrial process control requirernents and machines. A separate range, the series, is available for jarger and more complex application requirements.
Essentially there are two ranges (F-20 and F-40} in the F series. They share a common programmer. The ROM writer, program loader and other peripherals are also common to the F-20 and F-40 ranges. The F-12R model is fully compatible with F-20 and its peripherals except the ROM function is not available.
The extention units to expand the number of ihputs and outputs can be used with the base unit to give an overall choice of 1/O numbers from 12 to 80 by 10 points.
In addition to large variations such as supply voltage,
Nomenclatures of Base & Extension Unit
Model Expl.
F-COO-OOoa F-20MR-ES 1
O®@® O06
(ft) indicates the number of inputs/outputs
@) indicates type of the unit
M: Base Unit (RAM and ROM}
E: Extension Unit
N/A: Base Unit (RAM only)
@ indicates type of output
R: Relay, S: SSR, T: Transistor @ specifies power supply voltage ratings E: 220/240V AC, U: 110/120VAC, D: 24VDC (6) indicates type of input/output connections S: Source Input and Sink Output SS: Source Input and Source Output (Transistor) N/A: Sink Input and Sink Output
© indicates model version
PERIPHELALS output type or sink/source type, the analog timer unit Programming Panel F-20P-E and positioning counter module are available to cover praphic Programming GP-B0E many applications. ROM Writer F-20MW Program Loader F-20H ROM Cassette F-ROM-1 Remote Cable F-20P-CAB DIN Rail F-20D (for F-10, 12, 20} Attachment F-40D (for F-40) BASIC MODELS OF BASE UNIT & EXTENSION UNIT Unit F-10/12 F-20 F-40 OUTPUT TYPE Base Unit Extension Unit Base Unit Extension Unit Base Unit Extension Unit Relay Output F-12R F-10ER F-20MR F-20ER F-40MR F-40ER SSR Output - - F-20MS F-20€S F-40MS F-40ES Transistor Output - - F-20MT F-20ET F-40MF F-40ET
Output Loads
The basic unit and extension unit have the output power ratings indicated in the following table. For loads over the rated maximum limits shown, operation should be performed through an extra relay, capable of handling the load. Loads under the minimum limits shown will need an additional bleed resistor to prevent incorrect operation due to leakage currents flowing in the output circuits (no leakage current flows in the F-1GER unit and transistor unit}.
Relay Qutput 55F Outout Transistor Output Rated Output Current 2A a Point 1A a Point and 1A a Point and (Resistance load) a Frown 4A per 8 Points Total 4A per 8 Points Tota! Inductive Load . . 5OVA (110/120VA 3 jEx: Contactor, Solenoid, Stated in page 8 fOOVA eo ao aS) 24W (24V AC} J Solencid Valve etc. . 3W % Lamp Load 100W ioow (2W Lamp + GW solenoid} 2 Rush Current fOA/Cyele TOATEGycle 3ADC uo Inductive Load o ‘ O.6VA (110/120V AC} _ Oo Ex: Contactor Solenoid, _ a { Solenoid Valve etc. } 2.3V A (220/240V AC) 2 L: Load 0.4W (110/120VAC) _ S amp ©oa 1.8W (220/240V AC) N.B. = Leakage Current of Circuits = 1.1/1.2mA (110/120VAC) Max. 2.2/2.4mA (220/240V AC) Max., - - t-
Page 4
| Unit Installation |
Disposition of Extansion Unit
Connector Cover
' Extension | “Cable t
Installation on DIN-Rail
> DIN-Ftail (DIN 46277 35mm W) Type F-20D
Screw Hole Pitch (Direct {nstallation) mm
M4 Screw Hole
70202
240 + 0.2 (F-20) 155 + 0.2 (F-10/12)
[ DISCRIPTION // |
| CAUTION
VA
1. The base unit and extension unit can be mounted with suitable screws direct to any flat surface by using the four corner holes provided.
2. Alternatively an optional DIN rail mounting kit is available,
3. Basic and extension units are of the same dimensions and can be connected with the 300mm long extension cable provided with the extension unit. Connectors for the extension cable are jocated at the side of each unit and protected {when not in use) by a replaceable pliable cover.
. Whilst the F series PC is suitable for most industrial situations, it should not be used in excessively hostile environments associated with extremes of damp, dust, temperature, corrosive gases, vibration or mechanical impact.
. A space of some 30mm should be allowed around the unit for heat dissipation.
. The PC should not be installed near to high voltage suppiy cables or other such electrical apparatus.
Page 5
| Power Supply |
Power Suppl pry F-12 R-OO F-20M0-COO0
D Type: 24VDC U Type: 110/120VAC E Type: 220/240VAC
°) 29
Sink Input Type: To Common Terminal Source Input Type: To 24V Terminal
RUN
Switch 6 Earth o } stop h (Less than pr Swite 1002)
| ol [ejelelelsis[s|_/“ CoP gE
Power
Supply RUN STOP
Basic Unit
Ley /
_, DISCRIPTION //
[CAUTION // | w
. Connect a power supply cable of the correct rating to the basic unit and extension unit {if used) as illustrated.
. The power consumption of the basic unit is less than
11VA and that of the extension unit is less than 6VA. However this does not include the power consumption of any external joads.
. Ail units must be earthed as illustrated, . ‘Stop’ or ‘Run’ function terminals should be connected to key switches or other suitable control devices (push buttons) as illustrated.
. The ‘Run’ mode is used when the programmable controller is running a programme {controlling a system).
When the ‘Stop’ mode is used (or there is a power failure of more than 20 m/sec} all outputs are turned off and timers, plus 48 of the 64 auxiliary relays, are reset. However, all counters and 16 of the auxiliary relays are maintained in the cpu by integral auxiliary battery support.
1. Supply voltages should be as specified, and earthing specific to the programmable contraller e.g. not shared with any high power equipment such as a motor system.
2, When the ‘Stop’ switch is ‘on’, all outputs will be ‘off’. However, it is recommended that external facilities be provided in case of emergencies to support and back this facility.
3. The power must be off when the ROM cassette is loaded on the basic unit or unioaded from the unit.
Page 6
Wiring of Input/Output |
FF iii | Wiring of Input/Output Input Wires } Cable or Binding B22 Sicleels else ate Wat alelelh), foleleleleleleleleielela) | a tate ah Tol sis aes eee sae Biseloia el Output Wires Cable on Binding _ 1. Input and output wires must be kept separate and 3. it is recommended that input and output wires are away from any power supply cables or high voltage nat longer than 20 meters for the general use. cables. However the length depends upon the conditions of 2. For the sake of convenience, appearance and to avoid the noise environment and voltage drop.
damage or failure, input wires should be bound or cabled together as should output wires.
Page 7
[ Extension of the unit | ne NT +. Sink Input Type aeetatatind ETB Power I Earth fiess than 10092) + Common Lead Earth Lead ol [elelsie[2/s(e/7 OL_lelsisiele|s/// ee x
Suboty RUN STOP yin oo 80 Power Supely common p Earth @
Basic Unit
Ol [ei
Extension Unit s - ss F-12R-ES 2. Source Input Type poo ee © ) le apeR-Es!
Power 4 re Earth (less than 10092} we
Extensian Cable
24¥V Lead
OV Lead
Earth Lead ole lele[sie/2/s/8]9]e]e] / d_EERPERESee eer} 1a E jo a1 02 O324V : Poe AUN stan ao Sewer, é |OVj14 15 16 17/24V) | er | oO OD oO Basic Unit Extension Unit Extension Cable DISCRIPTION //
1. Any type of extension unit {relay, SSR or transistor} can be used with any base unit according to the output configuration required e.g, basic unit with relay outputs, extension unit with SSR outputs. However, DC power mode! and AC power model can-not be used in pair's of base unit and extension unit.
2. EXTENSION CABLE The extension cable used to connect the basic unit and an extension unit should be kept separate from any other cables or wires by a distance of 30mm at least.
. EARTH TERMINAL
The extension unit must be specitically earthed in the same manner as the basic unit.
. COMMON TERMINAL (U TYPE UNITS ONLY)
One of the common terminals of the extension unit should be connected to any one of the common terminals of the basic unit.
. 9 VOLT TERMINALS (ES TYPE UNITS ONLY)
OV terminals of extension and base units shall be connected together on the safety side.
. 24V TERMINAL (ES TYPE UNITS ONLY)
One of the 24V terminals of the base and extension units shall be connected together on the safety side.
Page 8
| Input Handling |
-U F-12R-U Sink Input Type iF sont D> fe. 10ER- uy)
pezavema | ot £ E, _:
i Sleleieieleleielsslelelele)e(e[e|/e/ee| oO Basic Unit C 00 01 02 03 C 04 05 06 O7 C 10 11 12 13 Input Input 00, 07 oa0000S00000 10-13 Input indicator 5 ° ole @] | DESCRIPTION // | | CAUTION WA
1. Connect control devices, e.g. limit switches, push 1. The input current rating at each input terminal is bottons etc., to the input terminations 00 to 13 of DC24V 8mA and control devices should be specified the base unit and 14 to 27 of the extension unit. accordingly.
2. All commen terminals are connected internally and 2. If transistor circuits such as proximity switches are are common. However base and extension unit connected to input terminals then their parallel commons are not linked unless connected together resistance should be more than 100k%2 and their externally as detailed in another section. series resistance tess than 1kQ2,
3. A pulse input of less than 50 milliseconds may not be accepted by the controller.
Page 9
| Input Handling |
= i Seana mapaaaaaae F-2000-ES, ESS - : Source Input Type (- ogoo-ps }, eiocres! = +
16~36VDC 7, ig/|e]/8] 9/9 [el 9|.8] 2/9] e]/e] oe] @] @/e/] e]e]_o n eo
Basic Unit 2 So s ce) input CO ~ 07 a 10~13 “
2 00 07 O02 03] {04 05 06 07/110 11:12 13 < S lec coccocos00 input Indicator
Input o
‘
| DESCRIPTION //
| CAUTION
VA
. Connect control devices e.g. limit switches, push buttons etc., to the input terminations 00 to 13 of the base unit and 14 to 27 of the extension unit.
. The base unit, and extension unit, each have their two 24V terminals commonly connected internally. However, it is necessary to connect one of the base and extension units’ 24V terminals together when using an extension unit.
1.
The input current at each input terminal is DC24V 6mA and contro! devices should be specified accordingly.
. The 24¥V input terminal points should not be used to power external transistors such as proximity switches. If this requirement exists, use an external power source of 16 to 36VDC.
. If transistor circuits such as proximity switches are connected to input terminals, then their resistance should be more than 100k%2, and their series resistance less than 1k&2.
. A pulse input of less than 50 milliseconds may not be accepted by the controller.
Page 10
| Output Handiing | cP -W2R-00 )
Relay Output Type (F-200R-O0) . (epee
BASE UNIT ofololol@ g9ooco oo |
734, 38) 38) 37, Output le Blelslolslelalele elele[slelelelelel 16
EXTENSION UNIT t40) 41) (43, ogg ago0dca
(443. 45) 46) 47) Output
LO sesPeelselelelelelol [aie] e]s| [Oo
Fuse
¢ © [
Small Load
Power Supply
Fuse Parallel Resistance = __ Free-wheel = ) Diode pc12~24v~ “ i Power Supply BC Load
DESCRIPTION // | |
CAUTION // |
1. Connect external load devices e.g. contactors, pilot lamps, solenoid {electromagnetic) valves etc., to output terminations.
2. Normal open relay contacts are connected internally to the output terminals on the base and extension units. The ratings of the contacts are 2A at 24VDC, 110/120VAC, 220/240VAC, These ratings apply for resistive loads (COS ¢ = 1.0).
3. Applicable loads to the output relays are subject to the frequency of operations. According to our fife test data, followings are given for a reference of the relay durability level:
Inductive Load Less than 35VA Less than 80VA Less than 120VA
Up to 3,000,006 Up to 1,000,000 Upto 200,000
Manufacturer's guaranty level: 500,000 operations at 35VA., -sa-
Frequency of Operation 3
1. Each internal contact is protected by a residual current circuit {except F-10ER model). When the contact is closed, its current leakage will normally be less than 2.2mA at 220VAC or 1.2mA at 120VAC. (No leakage current flows in the F-1GER})
However it is possible that this might have some effect on external loads.
Where the external current demand is very low it may prove necessary to provide additional parallel resistance because of the influence of leakage (see diagram above),
2. When using the controiler in a direct current circuit, it is recommended 40 connect a free wheel diode in parallel to the inductive load.
. Overload Protection Back-up fuses or circuit protectors are recommended on output circuits to prevent damage to the circuit boards of the PC in the event of a short circuit fault in an external output circuit.