FX Series Programmable Controllers

Outputs

6

6.3 ENG

Triac output example

FRE

Exemple d’un câblage de sortie triac

GER

Beispiel einer TriacAusgangsbeschaltung

ITL

Esempio del cablaggio di uscita di un triac

ESP

Ejemplo de una conexión de salida Triac

Figure: 6.4

ENG FRE GER ITL ESP

☞ Typical wiring ☞ Exemple de câblage ☞ Verdrahtungsbeispiel ☞ Esempio di cablaggio ☞ Ejemplo de cableado

Y0

Y0

Y1

Y1

Y2

Y2 com1

Y0

Y1

MC2

2

5

6

Y2

Y3

Y5

2 M C 1

M C 2

3

7

4

5

7

Y4

MC1

2

1 com2

1

Figure: 6.5

FX - 16EYS- ES-TB / FX2C

24 + 24 -

2

1

3

0

2 com1 com1 4

7

4

5

7 6 com2 com2

2

2

1

5 1 6

7 3

Table: 6.5 Item check

Description

Beschreibung

Descrizione

Descripción ESP

ITL

REF

ENG

A

AC power supply

Tension CA

AC-Spannung

Tensione AC

Tensión CA

B

Fuse

Fusible

Sicherung

Fusibile

Fusible

C

Solenoid valve

Electrovanne

Magnetventil

Elettrovalvola

Válvula electromagnética

D

Incandesent lamp

Lampe à incandescence

Glühlampe

Lampada a incandescenza

Bombilla

E

Neon lamp

Lampe fluorescente

Leuchtstofflampe

F

Contactor

Contacteur

Schütz

Relè di potenza

Contactor

G

Noise suppressor 0.1µF capacitor + 100 - 120 Ω resistor

Filtre antibruit: condensateur 0,1 µF + résistance 100 - 120 Ω

Rauschfilter: Kondensator 0,1 µF + Widerstand 100 120 Ω

Filtro antidisturbo: condensatore 0,1 µF + resistore 100 - 120Ω

Filtro de ruido: Condensador 0,1 µF + resistencia 100-120 Ω

GER

FRE

Lampada fluorescente Lámpara fluorescente

6-8

Page 82

FX Series Programmable Controllers

Outputs

6

6.4 ENG

Transistor output specification

FRE

GER

Technische Daten der Transistor-Ausgänge

ITL

Caractéristiques techniques des sorties des transistors

Dati tecnici delle uscite a transistor

Datos técnicos de las salidas transistorizadas Table: 6.6 ESP

FX/FX2C transistor specification

Caractéristiques des transistor FX/FX2C

Kenndaten der Transistor FX/FX2C

Parametri dei transistor FX/FX2C

Características de los transistor FX/FX2C

FX / FX2C Y0 ➩ ∞ ENG

Switched voltages (resistive load)

Rated current / N points (resistive load)

FRE

Tensions de démarrage (risistance ohmique)

Intensité nominale /N bornes (risistance ohmique)

GER

Einschaltspannungen (wirkwiderstand als verbraucher)

Nennstrom / N Klemmen (wirkwiderstand als verbraucher)

ITL

Tensioni di accensione (resistenza ohmica come consumatore)

Corrente nominale / N moresetti (resistenza ohmica come consumatore)

Tensiones de conexión (resistencia efectiva de consumo)

Corrente nominal / N bornas (resistencia efectiva de consumo)

Max. Inductive load

Max. lamp load (tungsten load)

ESP ENG FRE GER ITL ESP

Charge inductive max. max. induktive Last Carico max. Induttivo Carga inductiva máx

5 - 30V DC

FX 0.5A / 24V DC Charge d’allumage max. (tungsthne) (12W) max. Lampenlast FX2C (wolfram) 0.0125A/ 24V Carico max. lampade DC (volframio) (0.3W) Carga de lámpara máx. (tungsteno)

FX 0.5A / 1 point. 0.8A / common FX2C 0.1A / 1 point

FX 0.0625A / 24V DC (1.5W) FX2C 0.0125A / 24V DC (0.3W)

ENG

Response time (approx)(see note 6.4.1)

FRE

Temps de réponse (env.)(voir 6.4.1)

GER

Ansprechzeit (ca.)(siehe 6.4.1)

ITL

Tempo di reazione (circa)(v. 6.4.1)

ESP

Tiempo de reacción (aprox.)(ver 6.4.1)

ENG

Open circuit current leakage

Circuit isolation by photocoupler

FRE

Courant de fuite

Isolement du circuit

Par optocoupleur

Schaltkreisisolation

über Optokoppler

Corrente di dispersione

Isolamento circuiti tramite optoaccoppiatori

Corriente de fuga

Aislamiento de circuitode conmutación a través de optoacoplador

ENG

Operation indication

LED is lit when photocoupler is driven

FRE

Affichage de service

La LED s’allume lorsque l’optocoupleur est excitée.

GER

Betriebsanzeige

Die LED leuchtet, wenn Optokoppler aktiviert.

ITL

Indicazione di funzionamento

Il LED si accende quan l’optoaccop è eccitata.

Indicador de funcionamiento

El LED se enciende cuando está activado el optoacoplador

GER ITL ESP

ESP

Leckstrom

0.1mA / 30V DC

OFF é ON < 0.2 msec (FX = 200mA /24V DC FX2C = 100mA / 24V DC) ON é OFF < 0.2 msec (FX = 200mA /24V DC FX2C = 100mA / 24V DC)

6-9

Page 83

FX Series Programmable Controllers

6.4.1 ENG

FRE

GER

ITL

ESP

Outputs

6

Response times OFF times increase as the load current decreases. For improved response times use a ’dummy’ resistor, see Figure 6.6. If a response time of 0.5 msec or better is required when using ’light loads’ use a ’dummy’ resistor and ensure the signal line has a current greater than 60mA/24V DC. Temps de réponse Le temps de mise hors circuit augmente au fur et à mesure que le courant de charge augmente. Il est possible d’améliorer le pouvoir de réaction en ajoutant une réactance (voir illustration). Si un temps de réponse de 0.5 ms maximum est souhaité, il faut s’assurer qu’un courant de charge de 60 mA minimum avec 24 V CC soit disponible.

Ansprechzeiten Die Ausschaltzeit steigt bei abnehmenden Laststrom. Das Ansprechvermögen kann durch einen zusätzlichen Blindwiderstand verbessert werden (siehe Abb.). Falls eine Ansprechzeit von höchstens 0.5 ms gewünscht wird, muß sichergestellt werden, daß ein Laststrom vom mind. 60 mA bei DC 24 V ansteht.

Tempi di reazione Il tempo di spegnimento aumenta man mano che aumenta la corrente del carico. La capacità di reazione può essere migliorata mediante un’ulteriore reattanza efficace (v. figura). Se si desidera un tempo di reazione di max. 0.5 ms, si deve garantire una corrente di carico di almeno 60 mA a 24 V DC.

Tiempos de reacción El tiempo de desconexión aumenta a medida que aumenta la corriente de carga. La capacidad de reacción se puede optimizar mediante una reactancia inductiva adicional (ver la figura). En caso de que se desee un tiempo de reacción de 0.5 ms como máximo, se tiene que asegurar, que esté aplicada una tensión de carga de mín. 60 mA con 24 V CC.

Figure: 6.6

60 to 200mA +V

ENG FRE GER ITL ESP

☞ Dummy load ☞ Réactance ☞ Blindwiderstand ☞ Reattanza efficace ☞ Reactancia inductiva

5 to 30V

Y

ENG FRE GER ITL ESP

☞ Dummy load ☞ Réactance (charge fictive) ☞ Blindwiderstand ☞ Reattanza efficace ☞ Reactancia inductiva

Load Charge Last Carico Carga

6 - 10

Page 84

FX Series Programmable Controllers

Outputs

6.5 ENG

Transistor output example

FRE

Exemple d’un câblage de sortie de transistor

GER

Beispiel einer TransistorAusgangsbeschaltung

ITL

Esempio del cablaggio di uscita di un transistor

ESP

Ejemplo de una conexión de salida transistorizada

FX -✰✰MT-ESS, FX-✰✰ET-ESS, (Source)

Figure: 6.7

4 +V0

Y0

+V1

Y1

+V2

Y2

+V1

Y0

Y1

Y2

Y3

+V2

Y4

Y5 com2

Y4

Y5

3 MC2

2

2

MC1

M C 1

1 1

2 M C 2

FX -✰✰MT, FX-✰✰ET (Sink)Japanese spec.

Figure: 6.8

4 com0

Y0 com1

Y1 com2

Y2 com1

Y0

Y1

Y2

Y3

3 2

2

MC2

1 1

2

MC1

M C 1

M C 2

Table 6.7 Item check REF

ENG

Description

FRE

Beschreibung

GER

Descrizione

ITL

Descripción

ESP

A

DC power supply

Alimentation en tension CC

DC-Spannungsversorgung

Tensione di alimentazione DC

Alimentación de tensión CC

B

Fuse

Fusible

Sicherung

Fusibile

Fusible

C

External, mechanical inter-lock

Verrouillage mécanique extérieur externe mechanische Verriegelung

Bloccaggio meccanico esterno

Bloqueo mecánico externo

D

Internal noise suppressor

Filtre antibruit intérieur

Interner Rausch-Filter

Filtro antidisturbo interno

Filtro de ruido interno

6 - 11

6

Page 85

FX Series Programmable Controllers Figure: 6.9

Outputs

FX- 16EYT-ESS-TB / FX2C (Source )

4 24 + 24 -

1 0

3 2 com1 com1

5 4

2

2

1

7

MC2 M C 1

3

Figure: 6.10 com2

6 com2

MC1

2

M C 2

1

FX - 16EYT- TB / FX2C, (Sink) Japanese spec. 4 24 + 24 -

2 1

1 0

3 2 com1 com1

5 4

2

7 com2

6

MC2 M C 1

3 com2

MC1

2

M C 2

1

6 - 12

6

Page 86

FX Series Programmable Controllers

6.6 ENG

FRE

Outputs

6

Applying safe loads Ensure all loads are applied to the same side of each PC output, see previous figures. Loads which should NEVER simultaneously operate (e.g. direction control of a motor), because of a safety critical situation, should not rely on the PC’s sequencing alone. Mechanical interlocks MUST be fitted to all safety critical circuits. see Figure 6.7 Prescriptions de sécurité pour la mise en circuit de charges Assurez-vous que toutes les charges d’une application sont en circuit dans un trajet du courant d’un API. Les charges qui ne doivent JAMAIS être mises en circuit simultanément (par ex. commande directe d’un moteur), ne doivent pas être verrouillées mutuellement par l’intermédiaire du seul programme de l’API en raison de la situation de danger particulière. Un verrouillage mécanique supplémentaire est en tout cas nécessaire (voir illustrations précédentes).

GER

Sicherheitshinweise zur Beschaltung von Lasten Stellen Sie sicher, daß alle Lasten einer Anwendung im Strompfad einer SPS geschaltet werden. Lasten, die NIEMALS gleichzeitig eingeschaltet sein dürfen (z. B. direkte Steuerung eines Motors), sollten aufgrund der besonderen Gefahrensituation nicht allein über das SPS-Programm gegenseitig verriegelt werden. Es ist auf jeden Fall eine zusätzliche mechanische Verriegelung erforderlich (siehe vorherige Abbildungen).

ITL

Avvertenze per la sicurezza nel cablaggio di carichi Accertatevi che tutti i carichi di un’applicazione vengano comandati nella catena di un PC. I carichi che non devono MAI essere attivati insieme (ad es. comando diretto di un motore), non dovrebbero essere interbloccati soltanto tramite programma PC a causa della particolare situazione di pericolo. Occorre in ogni caso un interbloccaggio meccanico supplementare (v. figure precedenti).

ESP

Instrucciones de seguridad para la conexión de cargas Asegurar que todas las cargas de una aplicación sean conectadas en el circuito amperimétrico de una PC. Las cargas, que NUNCA deben estar conectadas simultáneamente (p.ej. mando directo de un motor), no deberán ser bloqueadas recíprocamente sólo a través del programa PC debido a causa de una situación crítica de peligro. Para ello se requiere siempre un bloqueo mecánico adicional (ver las figuras anteriores).

6 - 13

Page 87 read from a scan by OCR; it may hold reading errors

FX Series Programmable Controllers Outputs 6

MEMO a’a MITSUBISHI 6-14

Page 88

FX Series Programmable Controllers

1 2 3

Diagnostics

ENG

FRE

GER

ITL

ESP

Introduction

Introduction

Einleitung

Introduzione

Introducción

Occupation des bornes

Klemmenbelegungen

Assegnazione dei morsetti

Ocupaciones de bornas

Installation

Installation

Installazione

Instalación

Terminal Layouts

Installation Notes

4

Power supply

Alimentation en tension

Spannungsversorgung

Alimentazione della tensione

Alimentación de tensión

5

Inputs

Entrées

Eingänge

Ingressi

Entradas

6

Outputs

Sorties

Ausgänge

Uscite

Salidas

7

Diagnostics

Diagnostic d’erreurs

Fehlerdiagnose

Diagnostica

Diagnóstico de fallos y errores

8

Index

Index

Stichwortverzeichnis

Indice analitico

Indice alfabético

7-1

Page 89 read from a scan by OCR; it may hold reading errors

FX Series Programmable Controllers Diagnostics sa MITSUBISHI

Page 90

Diagnostics

FX Series Programmable Controllers

7

7.1 ENG

Preliminary checks

FRE

Vérifications à effectuer avant la mise en service

GER

Überprüfungen vor Betrieb

ITL

Controlli prima del funzionamento

ESP

Verificaciones preliminares

Table: 7.1 REF POWER RUN BATT.V PROG-E CPU-E

POWER RUN BATT.V PROG-E CPU-E

POWER RUN BATT.V PROG-E CPU-E

Check list

Points de contrôle

Prüfpunkte

Punti da controllare

Puntos de verificación

ENG

FRE

GER

ITL

ESP

Check power supply, ground and I/O cables are wired correctly. Check all terminal screws are tight.

A vérifier: l’alimentation en tension; le câblage de la terre et les câbles E/S; les bornes à vis

Überprüfen: Spannungsversorgung; Verdrahtung der Erdung und E-/A-Kabel; Schraubklemmen

Controllare: tensione di alimentazione; cablaggio della messa a terra e cavo I/O; morsetti a vite

Verificación: Alimentación de tensión; cableado de la puesta a tierra y cables de entrada/salida; bornas roscadas

Turn the power supply on. Check the power LED is lit. Down load a small test program into the PC using a handheld programmer or MEDOC. Verify the program to ensure it has been written to the PC correctly. Using the programming device forcibly turn ON/OFF each output. Check the output LEDS for operation.

Mettre en circuit l’alimentation en tension. Vérifier si la LED POWER s’allume. Transmettre le programme de test simple de l’appareil de programmation à l’API. Vérifier si le programme a bien été transmis à la mémoire de l’API. Mettre en horscircuit chaque sortie à l’aide de l’appareil de programmation. Vérifier les LED des sorties.

Spannungsversorgung einschalten. Überprüfen, ob die POWER-LED leuchtet. Einfaches Testpogramm vom Programmiergerät zur SPS übertragen. Überprüfen, ob das Programm richtig in den SPS-Speicher übertragen wurde. Mit Hilfe des Programmiergerätes jeden Ausgang EIN/AUS schalten. LEDs der Ausgänge überprüfen.

Attivare la tensione di alimentazione. Controllare se è acceso il LED POWER. Trasferire il programma di test semplice dal dispositivo di programmazione al PC. Controllare se il programma è stato trasmesso correttamente alla memoria del PC. Attivare/disattivare ogni uscita con il dispositivo di programmazione. Controllare i LED delle uscite.

Conectar la alimentación de corriente. Verificar, si se enciende el diodo POWERLED. Transferir el programa de prueba simple de la unidad de programación a la unidad PC. Verificar, si el programa ha sido transferido correctamente a la memoria de la unidad PC. Con ayuda de la unidad de programación, realizar una Conexion /Desconexion de cada salida. Comprobar los LED de las salidas.

Put the PC into RUN. Check the RUN LED is lit. Check the previously down loaded program works correctly. Once all checks are complete take the PC out of run and turn OFF the power supply.

Commuter l’API dans le mode RUN. Vérifier la LED RUN. Vérifier si le programme transmis auparavant fonctionne correctement. A l’issue des vérifications, couper le mode RUN et la tension.

SPS in den RUNModus schalten. RUN-LED überprüfen. Überprüfen, ob das vorher übertragene Programm korrekt arbeitet. Nach Abschluß der Überprüfungen RUN-Modus und Spannung auschalten.

Attivare la modalità RUN nel PC. Controllare il LED RUN. Controllare se il programma precedentemente trasmesso funziona correttamente. Al termine dei controlli disattivare la modalità RUN e disinserire la tensione.

Conmutar la unidad PC al modo RUN. Comprobar el diodo LED de RUN. Verificar, si el programa anteriormente transferido trabaja correctamente. Una vez terminadas las pruebas de verificación y comprobación, desconectar el modo RUN y la tensión.

During this testing stage take extrem care not to touch any live or hazardous parts.

Veillez à ne pas toucher de pièces sous tension pendant les vérifications.

Achten Sie darauf, daß Sie während der Überprüfungen keine unter Spannung stehenden Teile berühren.

Fate attenzione a non toccare durante i controlli parti che si trovano sotto tensione.

Durante las pruebas de verificación se tiene que observar, que no se toque ninguna de las piezas que se encuentran bajo tensión.

7-3