Page 1 of FX Series Programmable Controllers Hardware Manual

Manual · Mitsubishi

FX Series Programmable Controllers Hardware Manual

Manual121 pagesPDF 1.7 MB

Hardware manual for Mitsubishi FX Series PLCs: FX base and extension units, including the FX-8EYS triac output block, and FX2C base units.

Download the PDF1.7 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Multilingual hardware manual (English, French, German, Italian, Spanish) for the Mitsubishi FX Series programmable controllers. It covers FX base and extension units, extension and special function blocks such as the FX-8EYS triac output block, and FX2C base units: model names, system configuration rules, terminal layouts, installation and mounting, wiring and power supply, input and output specifications, diagnostics, error codes and battery replacement.

Its parts

  1. Introduction
  2. Terminal Layouts
  3. Installation
  4. Wiring techniques
  5. Inputs
  6. Outputs
  7. Diagnostics

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The Mitsubishi FX Series Programmable Controllers Hardware Manual, printed in English, French, German, Italian and Spanish, for FX base and extension units, FX extension and special function blocks, and FX2C base units. It names the triac extension blocks FX-8EYS-ES/UL and FX-16EYS-ES/UL, but never FX-8EYS on its own. It covers installation, wiring, input and output specifications, LED diagnostics and error codes.

Read for this summary: pages 12 to 17, 21, 43, 63, 79 to 81, 92 to 97 and 106 to 107 of 121.

Manual scope
FX base and extension units, FX extension and special function blocks, FX2C base units p. 12
Triac extension blocks
FX-8EYS-ES/UL: 8 triac outputs; FX-16EYS-ES/UL: 16 triac outputs p. 15
Triac switched voltage
Triac (SSR) outputs (FX, FX-16EYS-ES-TB): 85 - 242V AC p. 79
Triac rated current
0.3A per point and 0.8A per common, at 240 VAC p. 79
Triac response, isolation
OFF to ON < 1msec, ON to OFF < 10msec; isolation by photocoupler p. 79
Operating temperature
0 - 55 °C (32 - 131 °F); storage (-20) - 70 °C p. 43
Humidity
35 - 85% R.H., no condensation p. 43
Altitude, category
Up to <2000m; installation category II; pollution degree 2 p. 43
AC base unit supply
100 240V AC +10%, -15%, 50/60 Hz p. 13
Extension block size
Drawing dimensions 140 (5.51) and 95 (3.74) mm; 35mm (1.38) DIN rail p. 15
System limit
Maximum system 256 I/O p. 16
Error codes
D8061 6101: RAM error; D8063 6302: character error, 6303: data sum check error p. 106, 107
Battery check
BATT.V LED: monitor M8006; D8005 holds battery voltage in 0.1V units p. 93, 94

What this manual walks you through

  • Identifying FX and FX2C base units, extension units and blocks by model p. 13, 14, 15
  • Power needs of special function blocks and terminal blocks p. 16, 17
  • Laying out an FX system configuration p. 21
  • Checking the installation environment p. 43
  • Working out triac in-rush current p. 80
  • Wiring triac outputs to valves, lamps and contactors p. 81
  • Diagnosing the POWER, BATT.V, PROG.E and CPU.E LEDs p. 92, 93, 94, 95, 96, 97
  • Reading error codes in D8061 to D8063 p. 106, 107

Good to know

  • Triac in-rush current should be kept as low as possible, with Irms under 0.2A. p. 80
  • The operating area should be free of corrosive gases with minimal dust. p. 43
  • When BATT.V shows a low battery, copy any program or data held only in RAM at once, then replace the battery. p. 93
  • Too many loads on the 24V DC service supply need additional 24V DC supplies. p. 92
  • The triac wiring example uses a noise suppressor of a 0.1µF capacitor and a 100 - 120 Ω resistor. p. 81

Questions this manual answers

What voltage can Mitsubishi FX triac outputs switch?

85 - 242V AC, at 0.3A per point and 0.8A per common at 240 VAC. p. 79

What does the BATT.V LED on an FX PLC mean?

Monitor M8006; if the program or data is held only in RAM, copy it at once and then replace the battery. p. 93

What is the operating temperature of Mitsubishi FX PLCs?

0 - 55 °C (32 - 131 °F), with 35 - 85% R.H. and no condensation. p. 43

What does FX error code 6101 mean?

Code 6101 in D8061 is a RAM error. p. 106

How many I/O points can an FX system have?

A maximum system of 256 I/O. p. 16

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. FX Hardware Manual - English2
    1. Foreword1
    2. Guidelines for the safety of the user and protection of the FX PLC3
    3. 1. Introduction12
    4. 2. Terminal Layouts30
    5. 3. Installation38
    6. 4. Wiring techniques52
    7. 5. Inputs66
    8. 6. Outputs76
    9. 7. Diagnostics90
    10. 8. Index112
  2. FX Manuel du matériel - Français2
    1. Préface1
    2. 1. Introduction12
    3. 2. Occupation des bornes30
    4. 3. Installation38
    5. 4. Raccordement électrique52
    6. 5. Entrées66
    7. 6. Sorties76
    8. 7. Diagnostic d’erreurs90
    9. Index114
  3. FX Hardware-Handbuch - Deutsch2
    1. Vorwort1
    2. Sicherheitsrichtlinien für den Anwender und Schutzmaßnahmen für die FX-SPS5
    3. 1. Einleitung12
    4. 2. Klemmenbelegungen30
    5. 3. Installation38
    6. 4. Elektrischer Anschluß52
    7. 5. Eingänge66
    8. 6. Ausgänge76
    9. 7. Fehlerdiagnose90
    10. 8. Stichwortverzeichnis116
  4. FX Manuale hardware - Italiano2
    1. Premessa1
    2. Direttive di sicurezza per l’utente e misure di sicurezza per il PC FX6
    3. 1. Introduzione12
    4. 2. Assegnazione dei morsetti30
    5. 3. Installazione38
    6. 4. Allacciamento elettrico52
    7. 5. Ingressi66
14 more lines, from page 76 on
  1. 6. Uscite76
    1. 7. Diagnostica90
    2. 8. Indice analitico118
  2. FX Manual de Hardware - Español2
    1. Prólogo1
    2. Instrucciones de seguridad para el usuario y medidas de protección para la unidad PC-FX7
    3. 1. Introducción12
    4. 2. Ocupaciones de bornas30
    5. 3. Instalación38
    6. 4. Conexión eléctrica52
    7. 5. Entradas66
    8. 6. Salidas76
    9. 7. Diagnóstico de fallos y errores90
    10. 8. Indice alfabético120

From the PDF’s own bookmarks.

The whole text · 13 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Page 121121

The file

Revision and size

RevisionJY992D47401, revision L, October 2000
PublisherMitsubishi Electric
Pages121
PDF1.7 MB
TextText from the PDF itself; 11 pages are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 121

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 121
Page 2
Page 2of 121
Page 3
Page 3of 121

More documents · 1