Page 71
Devices in Detail
Programming Tips for Timers and Counters
Setting setpoints with the integrated potentiometers The controllers of the FX1S and FX1N series have two integrated analog potentiometers with which you can adjust setpoint values for timers and other functions quickly and easily.
100-240 VAC
L
N
The value of the upper potentiometer (VR1) can be read from special data register D8031, the value of the lower potentiometer (VR2) from register D8031. To use one of the potentiometers as the setpoint value source for a timer you just specify the corresponding register in your program instead of a constant.
X15 X7 X11 X13 X5 X3 X1 X14 S/S X6 X10 X12 X4 X2 X0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IN
POWER RUN ERROR
The value in the register can be adjusted between 0 and 255 by turning the potentiometer.
FX1N-24MR OUT
0 1 2 3 4 5 6 7 10 11 Y6 Y10 Y5 Y3 Y2 Y1 Y11 Y0 0V COM4 Y7 COM2 COM3 Y4 24+ COM0 COM1
24MR -ES/UL
MITSUBISHI
Potentiometer
Ladder Diagram
Instruction List
D8030 T1
X001 0
D8031 T2
T1 4 T1
0 1 4 5 8 8 10
T2 Y000
8
LD OUT LD OUT LD ANI OUT
X001 T1 T1 T2 T1 T2 Y000
D8030 D8031
In the program example above Y0 is switched on after the delay specified for timer T1, for the time specified for timer T2 (delayed pulse generation). Signal sequence ON
X1
OFF 1
[D8030]
T1 0 1
[D8031]
T2 0 ON
Y0
OFF t
FX Beginners Manual
4 – 13
Page 72
Programming Tips for Timers and Counters
4.6.2
Devices in Detail
Switch-off delay By default, all the timers in MELSEC PLCs are delayed make timers, i.e. the output is switched ON after the defined delay period. However, you will often also want to program a delayed break operation (switch OFF after a delay). A typical example of this is a ventilation fan in a bathroom that needs to continue running for several minutes after the lights are switched off. Program version 1 (latching) Ladder Diagram
Instruction List
X001 Y000
0 Y000
0 1 2 3 4 5 6
T0
K300 T0
X001 5
LD LD ANI ORB OUT LDI OUT
X001 Y000 T0 Y000 X001 T0
K300
As long as input X1 (e.g. a light switch) is on output Y0 (fan) is also on. However, the latching function ensures that Y0 also remains on after X1 has been switched off, because timer T0 is still running. T0 is started when X1 is switched off. At the end of the delay period (300 x 0.1s = 30s in the example) T0 interrupts the Y0 latch and switches the output off. Signal sequence X1 30 s T0
Y0 t
Program version 2 (set/reset) Ladder Diagram
Instruction List
X001 SET
0 X001 2
Y000
K300 T0
T0 6
RST
0 1 2 3 6 7
LD SET LDI OUT LD RST
X001 Y000 X001 T0
K300 T0
Y000
Y000
When X1 is switched on output Y0 is set (switched on). When X1 is switched off timer T0 is started. After the delay period T0 then resets output Y0. The resulting signal sequence is identical with that produced by program version 1.
4 – 14
MITSUBISHI ELECTRIC
Page 73
Devices in Detail
4.6.3
Programming Tips for Timers and Counters
Delayed make and break Sometimes you will want to switch an output on after a delay and then switch it off again after another delay. This is very easy to implement with the controller’s basic logical instructions. Ladder Diagram
Instruction List
0
K25 T1
4
K50 T2
X000
X000
T1
0 1 4 5 8 9 10 11
T2
8
Y000
LD OUT LDI OUT LD OR ANI OUT
X000 T1 X000 T2 T1 Y000 T2 Y000
K25 K50
Y000
Signal sequence ON
X0
OFF 1
T1 0 1
T2 0 ON
Y0
OFF t1 t2 t
Output Y000 is latched with the help of T1, keeping the output switched on until the end of the break delay period.
FX Beginners Manual
4 – 15
Page 74
Programming Tips for Timers and Counters
4.6.4
Devices in Detail
Clock signal generators The controllers have special relays that make it very easy to program tasks requiring a regular clock signal (for example for controlling a blinking error indicator light). Relay M8013 switches on and off at 1-second intervals, for example. For full details on all special relays see the Programming Manual for the FX family. If you need a different clock frequency or different on and off times you can program your own clock signal generator with two timers, like this: Ladder Diagram
X001
Instruction List
K10 T1
T2
0 T1
0 1 2 5 6 9
K20 T2
5
LD ANI OUT LD OUT OUT
X001 T2 T1 T1 T2 Y000
K10 K20
Y000
Input X1 starts the clock generator. If you want, you can omit this input – then the clock generator is always on. In the program you could use the output of T1 to control a blinking warning light. The on period is determined by T2, the off period by T1. The output of timer T2 is only switched on for a single program cycle. This time is shown much longer than it really is in the signal sequence illustration below. T2 switches T1 off and immediately after this T2 itself is also switched off. In effect this means that the duration of the on period is increased by the time that it takes to execute a program cycle. However, since the cycle is only a few milliseconds long it can usually be ignored. Signal sequence ON
X0
OFF 1
T1 0 t1
1
T2 t2 0 ON
Y1
OFF t
4 – 16
MITSUBISHI ELECTRIC
Page 75
More Advanced Programming
5
Applied Instructions Reference
More Advanced Programming The basic logic instructions listed in Chapter 3 can be used to emulate the functions of a hard-wired contactor controller with a programmable logic controller. However, this only scratches the surface of the capabilities of modern PLCs. Since every PLC is built around a microprocessor they can also easily perform operations like mathematical calculations, comparing numbers, converting from one number system to another or processing analog values. Functions like these that go beyond the capabilities of logic operations are performed with special instructions, which are referred to as applied or application instructions.
5.1
Applied Instructions Reference Applied instructions have short names that are based on the English names of their functions. For example, the instruction for comparing two 16-bit or 32-bit numbers is called CMP, which is short for compare. When you program an applied instruction you enter the instruction name followed by the device name. The following table shows all the applied instructions currently supported by the MELSEC FX family of controllers. This list may look a little overwhelming at first, but don’t worry – you don’t have to memorise them all! When you are programming you can use the powerful Help functions of GX Developer and GX IEC Developer to find the instructions you need. In this chapter we will only cover the more frequently-used instructions, which are shown with a grey shaded background in the reference table. For full documentation of all the instructions with examples please refer to the Programming Manual for the FX family. Category
Program flow functions
Move and compare functions
FX Beginners Manual
Instruction
Function
CJ
Conditional Jump to a program position
CALL
Calls (executes) a subroutine
SRET
Subroutine Return, marks the end of a subroutine
IRET
Interrupt Return, marks the end of an interrupt routine
EI
Enable Interrupt, enables processing of interrupt routines
DI
Disable Interrupt, disables processing of interrupt routines
Controller FX1S
FX1N
FX2N FX2NC FX3U
쏹
쏹
쏹
쏹
쏹
FEND
First End, marks end of main program block
WDT
WatchDog Timer refresh
FOR
Marks beginning of a program loop
NEXT
Marks end of a program loop
CMP
Compare numerical values
쏹
쏹
쏹
쏹
쏹 쏹
ZCP
Zone Compare, compares numerical ranges
쏹
쏹
쏹
쏹
MOV
Move data from one storage area to another
쏹
쏹
쏹
쏹
쏹
SMOV
Shift Move
쏹
쏹
쏹
CML
Compliment, copies and inverts
쏹
쏹
쏹
BMOV
Block Move
쏹
쏹
쏹
FMOV
Fill Move, copy to a range of devices
쏹
쏹
쏹
쏹
쏹
XCH
Exchange data in specified devices
쏹
쏹
쏹
BCD
BCD conversion
쏹
쏹
쏹
쏹
쏹
BIN
Binary conversion
쏹
쏹
쏹
쏹
쏹
5–1
Page 76
Applied Instructions Reference
Category
More Advanced Programming
Instruction ADD
Math and logic instructions
Rotate and shift functions
Data operation functions
Application instructions
5–2
Controller FX1S
FX1N
FX2N FX2NC FX3U
Add numerical values
쏹
쏹
쏹
쏹
쏹
SUB
Subtract numerical values
쏹
쏹
쏹
쏹
쏹
MUL
Multiply numerical values
쏹
쏹
쏹
쏹
쏹
DIV
Divide numerical values
쏹
쏹
쏹
쏹
쏹
INC
Increment
쏹
쏹
쏹
쏹
쏹
DEC
Decrement
쏹
쏹
쏹
쏹
쏹
AND
Logical AND
쏹
쏹
쏹
쏹
쏹
OR
Logical OR
쏹
쏹
쏹
쏹
쏹
XOR
Logical exclusive OR
쏹
쏹
쏹
쏹
쏹
NEG
Negation, logical inversion of device contents
쏹
쏹
쏹
ROR
Rotate right
쏹
쏹
쏹
ROL
Rotate left
쏹
쏹
쏹
RCR
Rotate carry right, rotate right with carry
쏹
쏹
쏹
RCL
Rotate carry left, rotate left with carry
쏹
쏹
쏹
SFTR
Shift right, bitwise shift to the right
쏹
쏹
쏹
쏹
쏹
SFTL
Shift left, bitwise shift to the left
쏹
쏹
쏹
쏹
쏹
WSFR
Word shift right, shift word values to the right
쏹
쏹
쏹
WSFL
Word shift left, shift word values to the left
쏹
쏹
쏹
SFWR
Shift register write, writes to a FIFO stack
쏹
쏹
쏹
쏹
쏹
SFRD
Shift register read, reads from a FIFO stack
쏹
쏹
쏹
쏹
쏹
ZRST
Zone Reset, resets ranges of like devices
쏹
쏹
쏹
쏹
쏹
DECO
Decode data
쏹
쏹
쏹
쏹
쏹
ENCO
Encode data
쏹
쏹
쏹
쏹
쏹
SUM
Sum (number) of active bits
쏹
쏹
쏹
BON
Bit on, checks status of a bit
쏹
쏹
쏹
MEAN
Calculates mean values
쏹
쏹
쏹
ANS
Timed annunciator set, starts a timer interval
쏹
쏹
쏹
Annunciator reset
쏹
쏹
쏹
SQR
Square root
쏹
쏹
쏹
FLT
Floating point, converts data
쏹
쏹
쏹
REF
Refresh inputs and outputs
쏹
쏹
쏹
ANR
High-speed instructions
Function
쏹
쏹
REFF
Refresh inputs and filter adjust
쏹
쏹
쏹
MTR
Input matrix, read a matrix (MTR)
쏹
쏹
쏹
DHSCS
High-speed counter set
쏹
쏹
쏹
쏹
쏹
DHSCR
High-speed counter reset
쏹
쏹
쏹
쏹
쏹
DHSZ
High speed zone compare
쏹
쏹
쏹
SPD
Speed detection
쏹
쏹
쏹
쏹
쏹
PLSY
Pulse Y output (frequency)
쏹
쏹
쏹
쏹
쏹
PWM
Pulse output with pulse width modulation
쏹
쏹
쏹
쏹
쏹
PLSR
Pulse ramp (accelleration/deceleration setup)
쏹
쏹
쏹
쏹
쏹
IST
Initial state, set up multi-mode STL system
쏹
쏹
쏹
쏹
쏹
SER
Search data stack
쏹
쏹
쏹
ABSD
Absolute counter comparison
쏹
쏹
쏹
쏹
쏹
INCD
Incremental counter comparison
쏹
쏹
쏹
쏹
쏹
TTMR
Teaching timer
쏹
쏹
쏹
STMR
Special timer
쏹
쏹
쏹
ALT
Alternate state, flip-flop function
쏹
쏹
쏹
쏹
쏹
RAMP
Ramp function
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
ROTC
Rotary table control
쏹
SORT
Sort table data on selected fields
쏹
MITSUBISHI ELECTRIC
Page 77
More Advanced Programming
Category
Instructions for external I/O devices
Instructions for external serial devices
Applied Instructions Reference
Instruction TKY
Ten key input
HKY
Hexadecimal key input
DSW
Digital switch
SEGD
7-segment display decoder
SEGL
7-segment display with latch
Floating point operations
Trigonometry instructions for floating point numbers
FX Beginners Manual
Controller FX1S
쏹 쏹
FX1N
쏹 쏹
FX2N FX2NC FX3U 쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
ARWS
Arrow switch
쏹
쏹
쏹
ASC
ASCII conversion
쏹
쏹
쏹
PR
Print, data output via the outputs
쏹
쏹
쏹
쏹
쏹
쏹
쏹
FROM
Read data from a special function module
TO
Write data to a special function module
쏹
쏹
쏹
쏹
RS
RS serial communications
쏹
쏹
쏹
쏹
쏹
PRUN
Parallel run (octal mode)
쏹
쏹
쏹
쏹
쏹
ASCI
Convert to an ASCII character
쏹
쏹
쏹
쏹
쏹
HEX
Convert to a hexadecimal character
쏹
쏹
쏹
쏹
쏹
CCD
Check Code, sum and parity check
쏹
쏹
쏹
쏹
쏹
VRRD
Read setpoint values from FX1N-8AV-BD and FX2N-8AV-BD
쏹
쏹
쏹
쏹
쏹
VRSC
Read switch settings from FX1N-8AV-BD and FX2N-8AV-BD
쏹
쏹
쏹
쏹
쏹
RS2
RS serial communications (2) 쏹
쏹
쏹
쏹
PID Store/restore index registers
Function
Program a PID control loop
쏹
ZPUSH
Zone push, store contents of index registers
ZPOP
Zone pop, restore contents of index registers
DECMP
Compare floating point values
쏹
쏹
쏹
쏹
쏹 쏹 쏹 쏹
DEZCP
Compare floating point values (range)
DEMOV
Move floating point values
쏹
DESTR
Convert floating point value to a string
쏹
DEVAL
Convert string to floating point value
쏹
DEBCD
Convert floating point value to scientific notation
쏹
쏹
쏹
DEBIN
Convert scientific notation to floating point
쏹
쏹
쏹
DEADD
Add floating point numbers
쏹
쏹
쏹
DESUB
Subtract floating point numbers
쏹
쏹
쏹
DEMUL
Multiply floating point numbers
쏹
쏹
쏹
DEDIV
Divide floating point numbers
쏹
쏹
DEXP
Floating point exponent
쏹
DLOGE
Calculate natural logarithm
쏹
DLOG10
Calculate decadic logarithm
DESQR
Square root of floating point numbers
DENEG
Reverse sign of floating point numbers
쏹
쏹 쏹
쏹
쏹 쏹
INT
Convert floating-point numbers to integers
쏹
쏹
쏹
SIN
Calculate the sine
쏹
쏹
쏹
COS
Calculate the cosine
쏹
쏹
쏹
TAN
Calculate the tangent
쏹
쏹
쏹
ASIN
Calculate the arc sine
쏹
ACOS
Calculate the arc cosine
쏹
ATAN
Calculate the arc tangent
쏹
RAD
Convert degrees to radians
쏹
DEG
Convert radians to degrees
쏹
5–3
Page 78
Applied Instructions Reference
Category
Data operations
Positioning instructions
Operations with the PLC’s integrated clock
Gray code conversion Data exchange with analog modules Instructions in external memory
Miscellaneous instructions
More Advanced Programming
Function
WSUM
Sum of the contents of word devices
쏹
WTOB
Word to byte, divide words into bytes
쏹
BTOW
Byte To Word, form words from individual bytes
쏹
UNI
Combine groups of 4 bits to form words
쏹
FX1S
FX1N
FX2N FX2NC FX3U
쏹
DIS
Divide words into groups of 4 bits
SWAP
Swap least and most significant bits
SORT
Sort the data in a table
쏹
DSZR
Return to zero home point (with proximity switch)
쏹
DVIT
Positioning with interrupt
쏹
TBL
Positioning with data table
DABS
Read absolute current position
쏹
쏹
쏹
쏹
쏹
쏹 쏹
쏹
쏹
ZRN
Return to zero home point
쏹
쏹
쏹
PLSV
Output pulses with variable frequency
쏹
쏹
쏹
DRVI
Position to an incremental value
쏹
쏹
쏹
DRVA
Position to an absolute value
쏹
쏹
쏹
TCMP
Compare clock data
쏹
쏹
쏹
쏹
쏹
TZCP
Compare clock data with a zone (range)
쏹
쏹
쏹
쏹
쏹
TADD
Add clock data
쏹
쏹
쏹
쏹
쏹
TSUB
Subtract clock data
쏹
쏹
쏹
쏹
쏹
HTOS
Convert hours / minutes / seconds time value to seconds
쏹
STOH
Convert seconds time value to hours / minutes / seconds
쏹
TRD
Read clock time and date
쏹
쏹
쏹
쏹
쏹
TWR
Write time and date to PLC clock
쏹
쏹
쏹
쏹
쏹
HOUR
Operating hours counter
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
쏹
GRY
Convert Gray code to decimal
GBIN
Convert decimal number to Gray code
RD3A
Read analog input values
WR3A
Write analog output values
EXTR
Execute command stored in an external ROM
COMRD
Read device comment
RND
Generate a random number
DUTY
Generate a pulse with a defined length
CRC
Check data (CRC check)
HCMOV
Instructions for data stored in consecutive devices (data blocks)
Controller
Instruction
쏹
쏹
Move the current value of a high-speed counter
BK+
Add data in a data block
BK-
Subtract data in a data block
BKCMP= BKCMP> BKCMP< BKCMP<>
쏹
Compare data in data blocks
BKCMP<= BKCMP>=
5–4
MITSUBISHI ELECTRIC
Page 79
More Advanced Programming
Category
String operations
Data table operations
Applied Instructions Reference
Instruction
Function
STR
Convert binary data to a string
VAL
Convert a string to binary data
$+
Concatenate strings
LEN
Returns the length of a string
RIGHT
Extract substring from right
LEFT
Extract substring from left
MIDR
Select a character string
MIDW
Replace a character strings
INSTR
Search for a character string
$MOV
Move a character string
FDEL
Delete data from a table
FINS
Insert data in a table
POP
Read last data inserted in a table
SFR
Shift a 16-bit data word right
SFL
Shift a 16-bit data word left
Controller FX1S
FX1N
FX2N FX2NC FX3U
쏹
쏹
LD= LD> LD< LD<> LD<= LD>= AND= Comparison operations
AND> AND<
Compare data within operations
쏹
쏹
쏹
쏹
쏹
AND>= OR= OR> OR< OR<> OR<= OR>=
Data control instructions
Instructions for communication with frequency inverters
Data exchange with special function modules High-speed counter instruction
FX Beginners Manual
LIMIT
Limits the output range of values
BAND
Define input offset
ZONE
Define output offset
SCL
Scale values
DABIN
Convert an ASCII number to a binary value
BINDA
Convert a binary value to ASCII code
SCL2
Scale values (different value table structure to SCL)
IVCK
Check status of frequency inverter
IVDR
Control frequency inverter
IVRD
Read frequency inverter parameter
IVWR
Write parameter to frequency inverter
IVBWR
Write parameters to frequency inverter in blocks
RBFM
Read from module buffer memory
WBFM
Write to module buffer memory
HSCT
Compare current value of a high-speed counter with data in data tables
쏹
쏹
쏹 쏹
5–5
Page 80
Applied Instructions Reference
Category
Instructions for extension file registers
5.1.1
More Advanced Programming
Controller
Instruction
Function
LOADR
Read data from extension file registers
SAVER
Write data to extension file registers
INITR
Initialise extension registers and extension file registers
LOGR
Read values from devices in extension registers and extension file registers
RWER
Write data from extension registers to extension file registers
INITER
Initialise extension file registers
FX1S
FX1N
FX2N FX2NC FX3U
쏹
Entering applied instructions Programming applied instructions in GX Developer FX is simple. Just position the cursor in the place in the program line where you want to insert the instruction and type the abbreviations for the instruction and its operand(s). GX Developer will automatically register that you are entering an instruction and will open the input dialog (see below). Alternatively, you can also position the cursor and then click on the insert instruction tool in the toolbar .
You can also select the instruction from the drop-down list, which you can display by clicking on the „쑽“ icon.
Then enter the abbreviations for the instruction and its operand(s) in the input field, separating them by spaces. All numbers must be preceded by a letter character, which either identifies the device type or – in the case of constants – specifies the number format. The letter “K” identifies decimal constants and “H” identifies hexadecimal constants. In the example on the left a MOV instruction is used to write the value 5 to data register D12. The Help button opens a dialog in which you can search for a suitable instruction for the function you want to perform. The help also contains information on how the functions work and the type and number of devices that they take as operands. Then you just click on OK to insert the applied instruction into the program.
M457 MOV K5 D12
If you are programming in Instruction List format enter the instruction and its operand(s) in a single line, separated by spaces.
5–6
MITSUBISHI ELECTRIC