Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of MELSEC FX Family Programmable Logic Controllers Beginners Manual

Manual · Mitsubishi

MELSEC FX Family Programmable Logic Controllers Beginners Manual

Manual106 pagesPDF 969 KB

Beginners manual for Mitsubishi MELSEC FX PLCs (FX1S, FX1N, FX2N, FX2NC, FX3U): what a PLC is, basic programming, devices.

Download the PDF969 KB

Covers · 1 model

The models it covers

Summary

What is in it

Mitsubishi Electric beginners manual for the MELSEC FX family of programmable logic controllers: FX1S, FX1N, FX2N, FX2NC and FX3U. It explains what a PLC is and how it processes programs, the layout of each series' base units, bits, bytes and number systems, the basic instruction set with worked examples (an alarm system, a rolling shutter gate), inputs, outputs, relays, timers, counters and registers, applied instructions for moving, comparing and math, and the expansion modules available.

Its parts

  1. Introduction
  2. Programmable Logic Controllers
  3. An Introduction to Programming
  4. Devices in Detail
  5. More Advanced Programming
  6. Expansion Options

From the manual

Key facts from this manual

Each line names its page in the PDF.

Mitsubishi Electric beginners manual (article number 166388, Version A, 2006) for the MELSEC FX family of programmable logic controllers: FX1S, FX1N, FX2N, FX2NC and FX3U. It explains what a PLC is, how to pick a base unit, the layout of the FX2NC base units, and the basics of programming inputs, outputs, relays and timers. It closes with an overview of expansion options.

Read for this summary: pages 1, 3, 7, 11 to 12, 17 to 25, 60, 62 and 101 to 102 of 106.

Manual
Beginners guide to installing, operating and programming MELSEC FX1S, FX1N, FX2N, FX2NC and FX3U PLCs p. 1, 3
FX2NC-32 I/O
FX2NC-32: 16 inputs and 16 outputs p. 21
Inputs
Floating inputs, isolated from the other PLC circuits by optical couplers p. 22
Memory battery
FX2NC: battery backs up RAM, latched timers, counters and relays, and the real-time clock p. 25
Service power
FX2NC: no built-in 24V DC service power supply for inputs and sensors p. 25
Status LEDs
FX2NC: POWER, RUN, BATT and ERROR LEDs plus input and output status LEDs p. 24
FX2NC layout
RUN/STOP switch, optional memory cassette slot, side extension bus, connectors for terminal strips, second interface for a CNV adapter p. 24
I/O addressing
FX2NC base units: 8, 16, 32 or 48 inputs from X00 and outputs from Y00, numbered in octal p. 60
Programming
FX-20P-E hand-held programming unit, or a PC or notebook with software such as GX Developer/FX p. 25
Output current
2 A on 250 V AC with relay outputs; 0.5 A on 24 V DC; non-reactive loads p. 22
Networks
Communications modules for the FX2NC: Profibus/DP, AS-interface, DeviceNet, CANopen, CC-Link p. 102
Special relays
M8004 PLC error; M8005 low battery voltage; M8034 disables outputs while the program keeps running p. 62

What this manual walks you through

  • What a PLC is and how it processes a program p. 17, 18, 19
  • Choosing the right FX base unit p. 21
  • Parts of the FX2NC base unit p. 24
  • What each PLC component does p. 25
  • Input and output numbering on each FX series p. 60
  • Using special relays and timers in a program p. 62
  • Expansion, analog, communications and positioning modules p. 101, 102

Good to know

  • The manual is meant for trained, qualified electrical technicians. p. 7
  • Only peripherals and expansion equipment recommended and approved by Mitsubishi Electric may be used. p. 7
  • Expansion adapter boards are available for all FX lines except the FX2NC. p. 25
  • With a memory cassette inserted, the PLC runs only the program stored in the cassette. p. 25
  • An input below its rated switching voltage is not processed. p. 22

Questions this manual answers

How many inputs and outputs does an FX2NC-32 base unit have?

16 inputs and 16 outputs. p. 21

Does the FX2NC have a 24V DC service power supply?

No. The manual says the 24V DC service power supply for inputs and sensors is not provided on the FX2NC. p. 25

What does the battery in an FX2NC do?

It keeps the RAM contents and the latched timers, counters and relays during a power failure, and powers the real-time clock. p. 25

What happens when a memory cassette is fitted to an FX PLC?

The internal memory is disabled and the PLC runs only the program in the cassette. p. 25

How are FX2NC inputs and outputs numbered?

Inputs are X and outputs are Y, numbered in octal from X00 and Y00. p. 60

The whole text · 11 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 106101-106

The file

Revision and size

RevisionArt. no.: 166388, Version A, 04/2006
PublisherMitsubishi Electric
Pages106
PDF969 KB