Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of FX2NC (D/UL) Series Programmable Controllers Hardware Manual

Manual · Mitsubishi

FX2NC (D/UL) Series Programmable Controllers Hardware Manual

Manual140 pagesPDF 2.3 MB

Hardware manual for Mitsubishi FX2NC (D/UL) series PLCs, including the FX2NC-32MT-D/UL main unit: installation, wiring, I/O and diagnostics.

Download the PDF2.3 MB

Covers · 1 model

The models it covers

Summary

What is in it

The hardware manual for the Mitsubishi FX2NC (D/UL) series programmable controllers, such as the FX2NC-16MT, -32MT, -64MT and -96MT main units. It covers model names and system configuration rules, terminal layouts for main units and extension blocks, installation and mounting, the 24V DC power supply and grounding, input and output specifications (transistor, relay and triac), and diagnostics with error codes, battery replacement, maintenance and an instruction list.

Its parts

  1. Introduction
  2. Terminal layouts
  3. Installation notes
  4. Power supply
  5. Inputs
  6. Outputs
  7. Diagnostics
  8. Discontinued model

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Mitsubishi hardware manual (JY992D87201, revision F, June 2010) for the FX2NC (D/UL) Series programmable controllers: the FX2NC-16MT-D/UL, FX2NC-32MT-D/UL, FX2NC-64MT-D/UL and FX2NC-96MT-D/UL main units with their extension and special function blocks. It covers system configuration, installation, power and I/O wiring, and diagnostics. The site files it under the FX2NC-32MT, which the manual names in its D/UL version.

Read for this summary: pages 1 to 3, 13 to 24, 28, 38, 43 to 46, 50 to 54, 71 to 74, 79 to 82, 91 to 95, 111 to 119, 123 and 131 of 140.

Main unit
FX2NC-32MT-D/UL: 16 inputs (24V DC sink) and 16 transistor (sink) outputs p. 13
Power supply
24V DC +20%, -15%, ripple 5% or less p. 71
5V DC capacity
FX2NC-32MT-D/UL: 560mA 5V DC current capacity p. 28
Inputs
24V DC +20%, -15%, photocoupler isolated, 10ms response, adjustable 0-60ms on X000-X017 p. 79
Transistor outputs
FX2NC main unit: 5-30V DC, 0.1A per point, 0.8A per 8 points, 0.3A per point on Y000-Y003 p. 91
Power cables
Supplied with the main unit: FX2NC-100MPCB main unit power cable and FX2NC-100BPCB input block power cable, both 1m p. 21, 73
Battery
FX2NC-32BL, 3 year life p. 116, 118
Output commons
FX2NC-32/64/96MT-D/UL: 16 points per common p. 94
Temperature
0 to 55 °C operating, -20 to 70 °C storage p. 54
FX2N block adapter
FX2NC-CNV-IF connects FX2N and FX0N extension and special function blocks p. 16
RUN/STOP control
RUN/STOP switch, a standard input (X000 to X017) set by parameters, or remotely from a PC p. 52
Memory and clock
Memory board / real time clock board connector; system diagram lists FX2NC-EEPROM-16, FX2NC-EEPROM-4C, FX2NC-EEPROM16C, FX2NC-ROM-CE1, FX2NC-RTC p. 24, 51
Programming devices
System diagram lists FX-20P-E, FX-30P, FX-10P-E, GX Developer and the FX-USB-AW RS422/USB converter p. 24
Error flags
M8004 error occurrence; M8005 battery voltage abnormally low; M8061 PC hardware error; M8064 parameter error; M8065 syntax error p. 119

What this manual walks you through

  • Choosing main units, extension blocks and special function blocks p. 13, 14, 15, 16, 17, 18, 19, 20
  • Totaling current consumption and I/O points of a system p. 28, 38
  • Terminal layouts of main units and extension blocks p. 43, 44, 45, 46
  • Controlling RUN and STOP by switch, input or remote p. 52, 53
  • Wiring the 24V DC power supply and power cables p. 71, 72, 73, 74
  • Wiring 24V DC inputs p. 79, 80, 81, 82
  • Wiring transistor outputs p. 91, 92, 93, 94, 95
  • Start-up checks and LED diagnostics p. 111, 112, 113
  • Writing and checking a program p. 115
  • Replacing the battery p. 116, 117

Good to know

  • A battery swap should take no more than 20 seconds to keep the data held in RAM. p. 116
  • Input extension and special function blocks should be powered before or together with the main unit when two supplies are used. p. 74
  • Do not modify the data in register D8008; the system corrects it automatically on the FX2NC. p. 73
  • Check that the BATT LED is off before transporting the PLC. p. 118
  • Loads such as forward/reverse contactors need an external interlock. p. 93

Questions this manual answers

What power supply does the FX2NC-32MT-D/UL need?

24V DC, +20% / -15%, with ripple of 5% or less. p. 71

What battery does the FX2NC use?

The FX2NC-32BL, which has a 3 year life. p. 116, 118

What does the BATT LED on an FX2NC mean?

Monitor M8006; if it is ON, save any program held only in RAM and replace the battery. p. 112

How do I connect FX2N extension blocks to an FX2NC?

Through the FX2NC-CNV-IF connector conversion adapter. p. 16

How much current can each FX2NC-32MT-D/UL output switch?

0.1A per point (0.3A on Y000 to Y003), and 0.8A per 8 points, at 5-30V DC resistive load. p. 91

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Cover1
  2. Mannual number3
  3. Guidelines4
  4. 1. Introduction13
    1. 1.1 Unit accessories21
    2. 1.2 World Spec.21
    3. 1.3 Model name22
    4. 1.4 Serial numbers23
    5. 1.5 Configuration24
  5. 2. Terminal layouts43
    1. 2.1 Main units43
    2. 2.2 FX2NC Extension blocks45
    3. 2.3 FX2N and FX0N Extension blocks46
  6. 3. Installation notes49
    1. 3.1 Product outline50
    2. 3.2 FX2NC RUN/STOP Control52
    3. 3.3 General specifications54
    4. 3.4 PC mounting arrangements55
    5. 3.5 Connection of extension blocks to main unit57
    6. 3.6 DIN rail mounting57
    7. 3.7 Direct mounting58
    8. 3.8 Extension cable installation62
    9. 3.9 General notes63
    10. 3.10 Memory Board installation64
    11. 3.11 Wiring techniques65
    12. 3.12 Termination of connector style I/O66
    13. 3.13 Termination of screw terminals67
    14. 3.14 Termination of connector style I/O cables68
  7. 4. Power supply71
    1. 4.1 Power supply cautions75
    2. 4.2 Earthing / Grounding76
  8. 5. Inputs79
    1. 5.1 24V DC input specifications79
    2. 5.2 AC110V input Extension block86
  9. 6. Outputs91
    1. 6.1 Transistor output specification91
    2. 6.2 Relay output specification96
    3. 6.3 Triac (SSR) output specifications103
    4. 6.4 Applying safe loads107
16 more lines, from page 111 on
  1. 7. Diagnostics111
    1. 7.1 Preliminary checks111
    2. 7.2 Basic diagnostics112
    3. 7.3 Common errors114
    4. 7.4 Writing of program and program check [power ON and PLC stopped]115
    5. 7.5 Replacing the battery116
    6. 7.6 Maintenance118
    7. 7.7 Error flags ON indicates error.119
    8. 7.8 Error registers121
    9. 7.9 Error codes123
    10. 7.10 Instruction list124
  2. 8. Discontinued model131
  3. 9. Appendix135
    1. 9.1 Precautions for Battery Transportation135
    2. 9.2 Handling of Batteries and Devices with Built-in Batteries in EU Member States136
  4. Back Cover140

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Guidelines4-6
  3. Contents7-12
  4. 1. Introduction, pages 13 to 2213-22
  5. 1. Introduction, pages 23 to 3223-32
  6. 1. Introduction, pages 33 to 4233-42
  7. 2. Terminal layouts43-48
  8. 3. Installation notes, pages 49 to 5649-56
  9. 3. Installation notes, pages 57 to 6457-64
  10. 3. Installation notes, pages 65 to 7065-70
  11. 4. Power supply71-78
  12. 5. Inputs79-90
  13. 6. Outputs, pages 91 to 10091-100
  14. 6. Outputs, pages 101 to 110101-110
  15. 7. Diagnostics, pages 111 to 120111-120
  16. 7. Diagnostics, pages 121 to 130121-130
  17. 8. Discontinued model131-134
  18. Pages 135 to 140135-140

The file

Revision and size

RevisionJY992D87201, revision F, June 2010
PublisherMitsubishi Electric
Pages140
PDF2.3 MB
TextText from the PDF itself; 14 pages are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 140

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 140
Page 2
Page 2of 140
Page 3
Page 3of 140

More documents · 1

For the same models