Page 33

FX2NC Series Programmable Controllers

Introduction 1.

Table 1.11 : Calculation form Block

Model

Current Number of consublocks mption connected

Current consumption × number of blocks

INPUT X

OUTPUT Y

X/Y

FX2NC series FX2NC-16EX-D/UL input extenFX2NC-32EX-D/UL sion block

30 mA blocks mA points points

60 mA blocks mA points points

FX2NC series FX2NC-16EYT-D/UL output extenFX2NC-32EYT-D/UL sion block

50 mA blocks mA points points

100 mA blocks mA points points mA blocks mA points points points mA blocks mA points points points mA blocks mA points points points mA blocks mA points points points mA blocks mA

- mA blocks mA

-

FX0N/FX2N series extension block (4 blocks, maximum) Function adapter 2-port interface

FX-2PIF s Total input points: r Total current t Total output points: consumption: u Total input/output common points: mA v Total points:

1-21 points points points points

Page 34

FX2NC Series Programmable Controllers

Introduction 1.

Judgment form a) 5V DC control current capacity check 5 V D C c u rre n t ca p a c ity o f m a in u n it (va lu e n s h o w n in S e c. 1 .5 .2 ): mA

≥

To ta l cu rre n t co n s u m p tio n o f a ll c o n n e c te d b lo c ks (va lu e r w ritte n in c a lcu la tio n fo rm ): mA b) Input/output point connection upper limit check In p u t p o in t c o n n e c tio n u p p e r lim it : 1 8 4 p o in ts ≥

In p u t p o in ts o f m a in u n it (va lu e o s h o w n in S e c . 1 .5 .2 ): + p o in ts

To ta l in p u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e s w ritte n in c a lc u la tio n fo rm ): p o in ts

= p o in ts

O u tp u t p o in t c o n n e c tio n u p p e r lim it: ≥ 1 8 4 p o in ts

O u tp u t p o in ts o f m a in u n it (va lu e p s h o w n in S e c . 1 .5 .2 ): + p o in ts

To ta l o u tp u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e t w ritte n in c a lc u la tio n fo rm ): p o in ts

= p o in ts

In p u t/o u tp u t p o in t c o n n e c tio n u p p e r lim it: ≥ 2 5 6 p o in ts

In p u t/o u tp u t p o in ts o f m a in u n it (va lu e q s h o w n in S e c . 1 .5 .2 ): + p o in ts

To ta l in p u t/o u tp u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e v w ritte n in c a lc u la tio n fo rm ): p o in ts

= p o in ts

If all the above conditions are met, the extension and special function blocks can be connected to the base block. If one of the above conditions is not met, reduce the number of input/output points or number of blocks, or change the types of blocks to be connected.

1-22

Page 35

FX2NC Series Programmable Controllers

1.5.4

Introduction 1.

System configuration example FX0N-485ADP (Function adapter)

FX2NC-32MT -D/UL

Main unit

FX2NC16EXD/UL

FX2NC32EXD/UL

FX2NC-CNV-IF (Connector conversion adapter) FX2NC- FX2NC32EYT- 32EYTD/UL D/UL

FX2NC series extension blocks

FX2N16EYRES/UL

FX2N1PG-E

FX2N4AD

FX2N4DA

4 blocks, maximum

1-23

Page 36

FX2NC Series Programmable Controllers

Introduction 1.

Table 1.12 : Calculation (Example) Block

Model

Current Number of consublocks mption connected

Current consumption × number of blocks

INPUT X

OUTPUT Y

X/Y

FX2NC series FX2NC-16EX-D/UL input extenFX2NC-32EX-D/UL sion block

30 mA

1 blocks

30 mA

16 points points

60 mA

1 blocks

60 mA

32 points points

FX2NC series FX2NC-16EYT-D/UL output extenFX2NC-32EYT-D/UL sion block

50 mA

0 blocks

0 mA points points

100 mA

2 blocks

200 mA points

64 points

FX2N-16EYR-ES/UL FX0N/FX2N series exten- FX2N-1PG-E sion block FX2N-4AD (4 blocks, maximum) FX2N-4DA

40 mA

1 blocks

40 mA points points

16 points

55 mA

1 blocks

55 mA points

8 points points

30 mA

1 blocks

30 mA points

8 points points

30 mA

1 blocks

30 mA points

8 points points

Function adapter

FX0N-485ADP

30 mA

1 blocks

30 mA

-

2-port interface

FX-2PIF mA

0 blocks

0 mA

-

48 points s Total input points: r Total current t Total output points : 80 points consumption: u Total input/output 24 points common points: 475 mA 152 points v Total points:

1-24

Page 37

FX2NC Series Programmable Controllers

Introduction 1.

Judgment (Example) a) 5V DC control current capacity check 5 V D C c u rre n t ca p a c ity o f m a in u n it (va lu e n s h o w n in S e c. 1 .5 .2 ): 5 6 0 m A

≥

To ta l c u rre n t co n s u m p tio n o f a ll c o n n e c te d b lo ck s (va lu e r w ritte n in c a lcu la tio n fo rm ): 4 7 5 m A

OK b) Input/output point connection upper limit check In p u t p o in t c o n n e c tio n u p p e r lim it : 1 8 4 p o in ts ≥

In p u t p o in ts o f m a in u n it (va lu e o s h o w n in S e c . 1 .5 .2 ): + 1 6 p o in ts

To ta l in p u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e s w ritte n in c a lc u la tio n fo rm ): 4 8 p o in ts

=

64 p o in ts

OK

O u tp u t p o in t c o n n e c tio n u p p e r lim it: ≥ 1 8 4 p o in ts

O u tp u t p o in ts o f m a in u n it (va lu e p s h o w n in S e c . 1 .5 .2 ): + 16 p o in ts

To ta l o u tp u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e t w ritte n in c a lc u la tio n fo rm ): 8 0 p o in ts

=

96 p o in ts

OK

In p u t/o u tp u t p o in t c o n n e c tio n u p p e r lim it: ≥ 2 5 6 p o in ts

In p u t/o u tp u t p o in ts o f m a in u n it (va lu e q s h o w n in S e c . 1 .5 .2 ): + 3 2 p o in ts

To ta l in p u t/o u tp u t p o in ts o f a ll c o n n e c te d b lo c k s (va lu e v w ritte n in c a lc u la tio n fo rm ): 1 5 2 p o in ts

=

184 p o in ts

OK

Calculation result: The 5V DC power total current consumption value and total input/output points are in the specified ranges, therefore the above system configuration is possible.

1-25

Page 38

FX2NC Series Programmable Controllers

1.5.5

Introduction 1.

Quick judgment To connect FX2NC series extension blocks only, use the following tables to quickly obtain the connectable input/output points. Example of quick judgment: • If 96 input points are connected to the FX2NC-32MT-D/UL main unit, up to 112 output points can be connected. • If the number of output points are determined first, select the same number or a slightly larger number from the output points (Y) area (area marked with *1). In this case, note that you cannot increase the corresponding number of input points shown above even if the determined number of output points is slightly smaller than the number shown in the table. However, if the same number of output points are listed twice, you can select the larger number of input points. Table 1.13: FX2NC-16M main unit (input: 8 points / output: 8 points) Input points of FX2NC series 0 16 32 48 64 80 96 112 128 144 160 176 input extension block (X) Output points of FX2NC series 176 176 160 160 144 144 128 112 112 96 80 64 ←*1 output extension block (Y) Total points including those of 192 208 208 224 224 240 240 240 256 256 256 256 main unit

1-26

Page 39

FX2NC Series Programmable Controllers

Introduction 1.

Table 1.14: FX2NC-32M main unit (input: 16 points / output: 16 points) Input points of FX2NC series input extension block (X)

0

16

32

48

64

80

96 112 128 144 160

Output points of FX2NC series 168 160 160 144 128 128 112 112 output extension block (Y) Total points including those of main unit

96

80

64 ←*1

200 208 224 224 224 240 240 256 256 256 256 Example of quick judgment

Table 1.15: FX2NC-64M main unit (input: 32 points / output: 32 points) Input points of FX2NC series 0 16 32 48 64 80 96 112 128 144 input extension block (X) Output points of FX2NC series 144 144 128 112 112 96 96 80 64 48 ←*1 output extension block (Y) Total points including those of 208 224 224 224 240 240 256 256 256 256 main unit

Table 1.16: FX2NC-96M main unit (input: 48 points / output: 48 points) Input points of FX2NC series 0 16 32 48 64 80 96 112 128 input extension block (X) Output points of FX2NC series 128 112 96 96 80 80 64 48 32 ←*1 output extension block (Y) Total points including those of 224 224 224 240 240 256 256 256 256 main unit

1-27

Page 40 read from a scan by OCR; it may hold reading errors

FX2NC Series Programmable Controllers Introduction 1.

MEMO ae MITSUBISHI 1-28

Page 41

FX2NC Series Programmable Controllers

1

INTRODUCTION

2

TERMINAL LAYOUTS

3

INSTALLATION NOTES

4

POWER SUPPLY

5

INPUTS

6

OUTPUTS

7

DIAGNOSTICS

8

DISCONTINUED MODEL

9

APPENDIX

Terminal layouts 2.

Page 42 read from a scan by OCR; it may hold reading errors

FX2NC Series Programmable Controllers Terminal layouts 2.

ae MITSUBISHI