User Manual EASY412, EASY600 Control Relay: Glossary
Pages 216 to 219 of 228, from User Manual EASY412, EASY600 Control Relay
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Moeller 621-DC-TCX
Page 216
08/00 AWB2528-1304-GB
Glossary
Analog input
The DC versions of “easy” have analog inputs I7 and I8. The input voltage range is 0 V to 10 V. Input data is evaluated by built-in analog comparator function relays.
Circuit connections
Each line in the circuit diagram display is a circuit connnection (EASY412: 41 circuit connections, EASY600: 121 circuit connections).
Circuit diagram symbols
As in conventional wiring, the circuit diagram is made up of circuit elements. These include input, output and marker relays, plus function relays and the P buttons.
Connect mode
Connect mode is used to wire up the circuit elements in your “easy” circuit diagram.
Contact behaviour
The contact behaviour of any circuit element can be defined as either a break contact or a make contact. Break contact elements are identified by a line on top of the identifier (Exception: Jump).
Entry mode
Entry mode is used to input or modify values when creating circuit diagrams or setting parameters, for example.
Function relays
Function relays are provided for more complex switching tasks. “easy” features the following types of relay:
213
Page 217
Glossary Timing relays Time switches Counters Analog comparators Text marker relays
Impulse relay
An impulse relay is a relay which changes its switching state and stays changed (latched) when a voltage is applied to the relay coil for a short time.
Input
The inputs are used to connect up external contacts. In the circuit diagram, inputs are evaluated via contacts I1 to I12 and R1 to R12. “easy” 24 V DC can also receive analog data via inputs I7 and I8.
Interface
The “easy” interface is used to exchange and save circuit diagrams to a memory card or PC. Each memory card contains one circuit diagram and its associated “easy” settings.
Local expansion
I/O expansion with the expansion unit (e.g. EASY620-DC-TE) installed directly on the basic unit. The connector is always supplied with the expansion unit.
Memory card
The memory card is used to store your “easy” circuit diagram, together with its parameter and “easy” settings. Your data on the memory card will be
214
08/00 AWB2528-1304-GB
The EASY-SOFT PC software allows you to control “easy” from your PC which is connected using the “easy-PC-CAB” cable.
Page 218
Glossary retained, even if the power supply fails or is switched off. The memory card is inserted into the interface slot on the “easy” device.
Operating buttons
“easy” has eight operating buttons. These are used to select menu functions and create circuit diagrams. The large round button in the middle is used to move the cursor.
08/00 AWB2528-1304-GB
DEL, ALT, ESC and OK all perform additional functions.
Operating mode
“easy” has two operating modes: RUN and STOP. RUN mode is used to process your circuit diagram (with the controller running continuously). In STOP mode you can create your circuit diagrams.
Output
You can connect various loads to the four “easy” outputs, such as contactors, lamps or and motors. In the “easy” circuit diagram the outputs are controlled via the corresponding output relay coils Q1 to Q8 or S1 to S8 (Q6).
P buttons
The P buttons can be used to simulate four additional inputs which are controlled directly by the four cursor buttons, rather than via external contacts. The relay contacts of P buttons are connected up in the circuit diagram.
Parameters
Parameters enable the user to set the behaviour of a function relay. Possible values include switching times or counter setpoints. They are set in the parameter display.
215
Page 219
Glossary Power supply
“easy”-AC is powered by AC voltage at 115 to 240 V AC, 50/60 Hz. The terminals are labelled “L” and “N”. “easy”-DC is powered by DC voltage at 24 V DC. The terminals are labelled “+24 V” and “0 V”. The terminals for the power feed are the first three terminals on the input side.
Remote expansion
I/O expansion with the expansion unit (e.g. EASY620-DC-TE) installed up to 30 m away from the basic unit. The EASY200-EASY coupling unit is fitted to the basic unit. The input and output data is exchanged between expansion and basic unit via a two-wire cable.
Retention
Retentive data is kept even after the “easy” power supply is switched off. The following data is retentive: “easy” circuit diagram
216
08/00 AWB2528-1304-GB
Parameters, setpoint values Texts System settings Password entry Actual values of marker relays, timing relays, counters