Page 1 of User Manual EASY412, EASY600 Control Relay

Manual · Moeller

User Manual EASY412, EASY600 Control Relay

Manual228 pagesPDF 3.1 MB

User manual for the Moeller "easy" EASY412 and EASY600 control relays, including the EASY621-DC-TC(X): installation, wiring and programming.

Download the PDF3.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

Moeller user manual for the EASY412 and EASY600 "easy" control relays, programmable control and timing relays used in place of relay and contactor controls. Among the types it lists is the EASY621-DC-TC(X). It covers mounting and wiring of power, inputs, relay and transistor outputs and expansion, commissioning, drawing circuit diagrams with contacts, timing and counter relays, time switches and analog comparators, loading and saving with the memory card or EASY-SOFT, settings, retention, troubleshooting and technical data.

Its parts

  1. Instructions for Use
  2. "easy"
  3. Installation
  4. Commissioning
  5. Drawing a Circuit Diagram with "easy"
  6. Loading and Saving Circuit Diagrams
  7. "easy" Settings
  8. Retention
  9. Inside "easy"
  10. What Happens If ...?
  11. Technical Data

From the manual

Key facts from this manual

Each line names its page in the PDF.

Moeller user manual AWB2528-1304-GB (edition 08/00) for the EASY412 and EASY600 "easy" control relays, among them the EASY621-DC-TC(X) as well as EASY412, EASY618, EASY619 and EASY620 types. It explains mounting and wiring, drawing circuit diagrams, loading and saving them by memory card or EASY-SOFT, settings, retention, troubleshooting and technical data.

Read for this summary: pages 1 to 3, 8 to 15, 28 to 29, 44 to 45, 128 to 129, 190 to 191 and 197 to 214 of 228.

Device
Electronic control relay with built-in logic, timer, counter and time switch functions, programmed as ladder diagrams p. 12
Type code
6 = 107.5 mm wide; 21 = 12 I/8 O + expansion; DC = 24 V DC; T = transistor outputs (0.5 A); C = time switch; X = no display p. 14
Programming (X models)
Models without buttons load a circuit diagram via EASY-SOFT or automatically from the fitted memory card at each power-up p. 128
Supply
EASY62.-DC-T..: 24 V DC +20%/-15% (20.4 to 28.8), normally 140 mA, normally 3.5 W p. 205
Transistor outputs
Max. 0.5 A DC each; up to four in parallel within a group for max. 2 A; thermal short-circuit protection p. 45, 211
Operating temperature
-25 to 55 °C (-13 to 131 °F), installed horizontally or vertically p. 203
Analog inputs
EASY6..-DC: I7 and I8 usable as 0 to 10 V DC analog inputs, 0.1 V resolution, 30 m shielded cable p. 207, 208
Output fault inputs
EASY62.-D.-T..: internal input I16 signals a short-circuit or overload on Q1 to Q4, I15 on Q5 to Q8 p. 190
Memory card
easy-M16K for EASY600 (easy-M-8K for EASY412); one circuit diagram per card, kept without power p. 129
Time switches
C models: four 7-day time switches, each with up to four on and off times p. 12
Clock back-up
C models: normally 64 h at 25 °C/77 °F, 24 h at 40 °C/104 °F p. 204
Mounting
DIN 50 022 35 mm rail, or screws with 3 ZB-101-GF1 mounting feet p. 200
Wiring
Solid 0.2 to 4 mm2; flexible with ferrule 0.2 (AWG 24) to 2.5 mm2 (AWG 12); 3.5 mm screwdriver, 0.6 Nm p. 28
Error messages
ERROR: EEPROM (memory faulty), ERROR: CLOCK (clock error), ERROR: LCD (LCD faulty); the remedy given is replacing the unit p. 197

What this manual walks you through

  • Reading the device overview and type code p. 13, 14
  • Using the operating buttons and menus p. 15
  • Connecting the power supply p. 28, 29
  • Connecting transistor outputs and wiring them in parallel p. 44, 45
  • Loading and saving circuit diagrams by memory card or EASY-SOFT p. 128, 129
  • Monitoring transistor outputs for short-circuit and overload p. 190, 191
  • Understanding system messages p. 197
  • Solving problems when creating circuit diagrams p. 198, 199
  • Technical data for supply, inputs, outputs and cycle time p. 200, 205, 207, 211, 213

Good to know

  • The relay is not to be used in place of safety-related controls such as burner or crane controls, emergency-stop or two-hand controls. p. 9
  • Outputs may be paralleled only within a group (Q1 to Q4 or Q5 to Q8) and must switch at the same time. p. 45
  • Voltage on the outputs while the supply polarity is reversed causes a short circuit. p. 211
  • Only trained electricians or people familiar with electrical installation may install and connect it. p. 8
  • Circuit diagrams can move from an easy-M-8K card to the EASY600, but not the other way. p. 129

Questions this manual answers

How do I program an EASY621-DC-TCX that has no buttons?

Load the circuit diagram with EASY-SOFT from a PC, or fit a memory card, which loads it automatically at every power-up. p. 128

What does ERROR: EEPROM mean on an easy relay?

The memory for the retentive values or the circuit diagram is faulty; the manual's remedy is to replace the unit. p. 197

What supply voltage does the EASY621-DC-TC need?

24 V DC, within 20.4 to 28.8 V, drawing normally 140 mA. p. 205

How much current can an EASY621 transistor output switch?

Up to 0.5 A DC per output; up to four outputs in one group can be paralleled for a maximum of 2 A. p. 45, 211

Which memory card fits the EASY600?

The easy-M16K card. p. 129

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Title1
    1. User Manual1
    2. EASY412, EASY6001
    3. Control Relay1
  2. Safety Instructions2
    1. Warning!2
    2. Dangerous electrical voltage!2
    3. Before commencing the installation2
    4. List of revisions to AWB2528-1304-GB3
  3. 1 Instructions for Use8
    1. Target readership8
    2. Proper use8
    3. Hazard categories and warnings9
    4. Safety instructions10
    5. Device designation10
  4. 2 “easy”12
    1. Overview12
    2. Versions13
    3. “easy” operating principles15
  5. 3 Installation24
    1. Mounting24
    2. Connecting the expansion device27
    3. Terminals28
    4. Connecting the power supply28
    5. Connecting the inputs31
    6. Connecting the outputs42
    7. Connecting relay outputs42
    8. Connecting transistor outputs44
    9. Expanding inputs/ outputs47
  6. 4 Commissioning50
    1. Switching on50
    2. Setting the menu language50
    3. “easy” operating modes51
    4. Creating your first circuit diagram52
  7. 5 Drawing a Circuit Diagram with “easy”62
    1. Operation of “easy”62
    2. Working with contacts and relays67
    3. Function relay80
    4. Timing relays87
53 more lines, from page 93 on
  1. Counter relays93
    1. Time switch96
    2. Analog comparators101
    3. Text display106
    4. Jumps108
    5. Example circuits111
  2. 6 Loading and Saving Circuit Diagrams128
    1. EASY...-..-..X128
    2. Interface128
    3. Memory card129
    4. EASY-SOFT133
  3. 7 “easy” Settings136
    1. Password protection136
    2. Changing the menu language142
    3. Changing parameters143
    4. Setting the time146
    5. Changing between winter/summer time (DST)147
    6. Activating debounce (input delay)148
    7. Activating and deactivating P buttons149
    8. Startup behaviour150
    9. Behaviour when the circuit diagram is deleted152
    10. Behaviour during uploading and downloading to the card or PC152
    11. Possible faults152
  4. 8 Retention154
    1. Requirements154
    2. Setting retention155
    3. Deleting retentive actual values156
    4. Transfer retentive behaviour157
    5. Retentive auxiliary relays (markers)159
    6. Retentive timing relay164
    7. Retentive Up/down counters C7, C8173
  5. 9 Inside “easy”178
    1. “easy” circuit diagram cycle178
    2. Determining the cycle time of “easy” circuit diagrams180
    3. Delay times for inputs and outputs187
    4. Monitoring for short- circuit/Overload with EASY..-D.-T..190
    5. Expanding EASY600193
  6. 10 What Happens If ...?196
    1. Message from the “easy” system197
    2. Possible situations when creating circuit diagrams198
    3. Event199
  7. 11 Technical Data200
    1. General200
    2. Power supply205
    3. Inputs206
    4. Relay outputs209
    5. Transistor outputs211
    6. Cycle time213
  8. Glossary216
  9. Index220
  10. FO 98227
    1. Part 1227
    2. Part 2228

From the PDF’s own bookmarks.

The whole text · 28 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Contents4-7
  3. 1 Instructions for Use8-11
  4. 2 “easy”12-23
  5. 3 Installation, pages 24 to 3224-32
  6. 3 Installation, pages 33 to 4133-41
  7. 3 Installation, pages 42 to 4942-49
  8. 4 Commissioning50-61
  9. 5 Drawing a Circuit Diagram with “easy”, pages 62 to 7162-71
  10. 5 Drawing a Circuit Diagram with “easy”, pages 72 to 8172-81
  11. 5 Drawing a Circuit Diagram with “easy”, pages 82 to 9182-91
  12. 5 Drawing a Circuit Diagram with “easy”, pages 92 to 10192-101
  13. 5 Drawing a Circuit Diagram with “easy”, pages 102 to 111102-111
  14. 5 Drawing a Circuit Diagram with “easy”, pages 112 to 121112-121
  15. 5 Drawing a Circuit Diagram with “easy”, pages 122 to 127122-127
  16. 6 Loading and Saving Circuit Diagrams128-135
  17. 7 “easy” Settings, pages 136 to 144136-144
  18. 7 “easy” Settings, pages 145 to 153145-153
  19. 8 Retention, pages 154 to 161154-161
  20. 8 Retention, pages 162 to 169162-169
  21. 8 Retention, pages 170 to 177170-177
  22. 9 Inside “easy”, pages 178 to 186178-186
  23. 9 Inside “easy”, pages 187 to 195187-195
  24. 10 What Happens If...?196-199
  25. 11 Technical Data, pages 200 to 207200-207
  26. 11 Technical Data, pages 208 to 215208-215
  27. Glossary216-219
  28. Pages 220 to 228220-228

The file

Revision and size

Part no.AWB2528-1304-GB
Revision4th edition, 08/00
PublisherMoeller GmbH
Pages228
PDF3.1 MB
TextText from the PDF itself.
AWB2528-1304-GB

The first pages · 3 of 228

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 228
Page 2
Page 2of 228
Page 3
Page 3of 228

More documents · 1

For the same models