Manual · Moeller
User Manual EASY412, EASY600 Control Relay
Manual228 pagesPDF 3.1 MB
User manual for the Moeller "easy" EASY412 and EASY600 control relays, including the EASY621-DC-TC(X): installation, wiring and programming.
Covers · 1 model
The models it covers
Summary
What is in it
Moeller user manual for the EASY412 and EASY600 "easy" control relays, programmable control and timing relays used in place of relay and contactor controls. Among the types it lists is the EASY621-DC-TC(X). It covers mounting and wiring of power, inputs, relay and transistor outputs and expansion, commissioning, drawing circuit diagrams with contacts, timing and counter relays, time switches and analog comparators, loading and saving with the memory card or EASY-SOFT, settings, retention, troubleshooting and technical data.
Its parts
- Instructions for Use
- "easy"
- Installation
- Commissioning
- Drawing a Circuit Diagram with "easy"
- Loading and Saving Circuit Diagrams
- "easy" Settings
- Retention
- Inside "easy"
- What Happens If ...?
- Technical Data
From the manual
Key facts from this manual
Each line names its page in the PDF.
Moeller user manual AWB2528-1304-GB (edition 08/00) for the EASY412 and EASY600 "easy" control relays, among them the EASY621-DC-TC(X) as well as EASY412, EASY618, EASY619 and EASY620 types. It explains mounting and wiring, drawing circuit diagrams, loading and saving them by memory card or EASY-SOFT, settings, retention, troubleshooting and technical data.
- Device
- Electronic control relay with built-in logic, timer, counter and time switch functions, programmed as ladder diagrams p. 12
- Type code
- 6 = 107.5 mm wide; 21 = 12 I/8 O + expansion; DC = 24 V DC; T = transistor outputs (0.5 A); C = time switch; X = no display p. 14
- Programming (X models)
- Models without buttons load a circuit diagram via EASY-SOFT or automatically from the fitted memory card at each power-up p. 128
- Supply
- EASY62.-DC-T..: 24 V DC +20%/-15% (20.4 to 28.8), normally 140 mA, normally 3.5 W p. 205
- Transistor outputs
- Max. 0.5 A DC each; up to four in parallel within a group for max. 2 A; thermal short-circuit protection p. 45, 211
- Operating temperature
- -25 to 55 °C (-13 to 131 °F), installed horizontally or vertically p. 203
- Analog inputs
- EASY6..-DC: I7 and I8 usable as 0 to 10 V DC analog inputs, 0.1 V resolution, 30 m shielded cable p. 207, 208
- Output fault inputs
- EASY62.-D.-T..: internal input I16 signals a short-circuit or overload on Q1 to Q4, I15 on Q5 to Q8 p. 190
- Memory card
- easy-M16K for EASY600 (easy-M-8K for EASY412); one circuit diagram per card, kept without power p. 129
- Time switches
- C models: four 7-day time switches, each with up to four on and off times p. 12
- Clock back-up
- C models: normally 64 h at 25 °C/77 °F, 24 h at 40 °C/104 °F p. 204
- Mounting
- DIN 50 022 35 mm rail, or screws with 3 ZB-101-GF1 mounting feet p. 200
- Wiring
- Solid 0.2 to 4 mm2; flexible with ferrule 0.2 (AWG 24) to 2.5 mm2 (AWG 12); 3.5 mm screwdriver, 0.6 Nm p. 28
- Error messages
- ERROR: EEPROM (memory faulty), ERROR: CLOCK (clock error), ERROR: LCD (LCD faulty); the remedy given is replacing the unit p. 197
What this manual walks you through
- Reading the device overview and type code p. 13, 14
- Using the operating buttons and menus p. 15
- Connecting the power supply p. 28, 29
- Connecting transistor outputs and wiring them in parallel p. 44, 45
- Loading and saving circuit diagrams by memory card or EASY-SOFT p. 128, 129
- Monitoring transistor outputs for short-circuit and overload p. 190, 191
- Understanding system messages p. 197
- Solving problems when creating circuit diagrams p. 198, 199
- Technical data for supply, inputs, outputs and cycle time p. 200, 205, 207, 211, 213
Good to know
- The relay is not to be used in place of safety-related controls such as burner or crane controls, emergency-stop or two-hand controls. p. 9
- Outputs may be paralleled only within a group (Q1 to Q4 or Q5 to Q8) and must switch at the same time. p. 45
- Voltage on the outputs while the supply polarity is reversed causes a short circuit. p. 211
- Only trained electricians or people familiar with electrical installation may install and connect it. p. 8
- Circuit diagrams can move from an easy-M-8K card to the EASY600, but not the other way. p. 129
Questions this manual answers
How do I program an EASY621-DC-TCX that has no buttons?
Load the circuit diagram with EASY-SOFT from a PC, or fit a memory card, which loads it automatically at every power-up. p. 128
What does ERROR: EEPROM mean on an easy relay?
The memory for the retentive values or the circuit diagram is faulty; the manual's remedy is to replace the unit. p. 197
What supply voltage does the EASY621-DC-TC need?
24 V DC, within 20.4 to 28.8 V, drawing normally 140 mA. p. 205
How much current can an EASY621 transistor output switch?
Up to 0.5 A DC per output; up to four outputs in one group can be paralleled for a maximum of 2 A. p. 45, 211
Which memory card fits the EASY600?
The easy-M16K card. p. 129
Contents
Chapters and sections
Each line opens the PDF at its page.
- Title1
- Safety Instructions2
- 1 Instructions for Use8
- 2 “easy”12
- 3 Installation24
- 4 Commissioning50
- 5 Drawing a Circuit Diagram with “easy”62
53 more lines, from page 93 on
- Counter relays93
- 6 Loading and Saving Circuit Diagrams128
- 7 “easy” Settings136
- Password protection136
- Changing the menu language142
- Changing parameters143
- Setting the time146
- Changing between winter/summer time (DST)147
- Activating debounce (input delay)148
- Activating and deactivating P buttons149
- Startup behaviour150
- Behaviour when the circuit diagram is deleted152
- Behaviour during uploading and downloading to the card or PC152
- Possible faults152
- 8 Retention154
- 9 Inside “easy”178
- 10 What Happens If ...?196
- 11 Technical Data200
- Glossary216
- Index220
- FO 98227
The whole text · 28 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 31-3
- Contents4-7
- 1 Instructions for Use8-11
- 2 “easy”12-23
- 3 Installation, pages 24 to 3224-32
- 3 Installation, pages 33 to 4133-41
- 3 Installation, pages 42 to 4942-49
- 4 Commissioning50-61
- 5 Drawing a Circuit Diagram with “easy”, pages 62 to 7162-71
- 5 Drawing a Circuit Diagram with “easy”, pages 72 to 8172-81
- 5 Drawing a Circuit Diagram with “easy”, pages 82 to 9182-91
- 5 Drawing a Circuit Diagram with “easy”, pages 92 to 10192-101
- 5 Drawing a Circuit Diagram with “easy”, pages 102 to 111102-111
- 5 Drawing a Circuit Diagram with “easy”, pages 112 to 121112-121
- 5 Drawing a Circuit Diagram with “easy”, pages 122 to 127122-127
- 6 Loading and Saving Circuit Diagrams128-135
- 7 “easy” Settings, pages 136 to 144136-144
- 7 “easy” Settings, pages 145 to 153145-153
- 8 Retention, pages 154 to 161154-161
- 8 Retention, pages 162 to 169162-169
- 8 Retention, pages 170 to 177170-177
- 9 Inside “easy”, pages 178 to 186178-186
- 9 Inside “easy”, pages 187 to 195187-195
- 10 What Happens If...?196-199
- 11 Technical Data, pages 200 to 207200-207
- 11 Technical Data, pages 208 to 215208-215
- Glossary216-219
- Pages 220 to 228220-228
The file