Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 25 of 28

User Manual EASY412, EASY600 Control Relay: 11 Technical Data, pages 200 to 207

Pages 200 to 207 of 228, from User Manual EASY412, EASY600 Control Relay

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Moeller 621-DC-TCX

Page 200

11

General

Technical Data

EASY... EASY200-EASY

EASY412

EASY600

[mm]

35.5 90 53

71.5 90 53

107.5 90 53

[inches]

1.4 3.54 2.08

2.81 3.54 2.08

4.23 3.54 2.08

Space units

2 space units wide

4 SU (space units) wide

6 SU (space units) wide

[g]

70

200

300

[lb]

0.154

0.441

0.661

Dimensions W H D

Weight

Mounting

DIN 50 022, 35 mm rail or screw mounting with 3 ZB-101-GF1 mounting feet (accessories); with EASY200-EASY only 2 mounting feet required.

08/00 AWB2528-1304-GB

45

110

90

4.5

M4 7.5 35.5

102

7.5

47.5 56.5 58

Figure 2: Dimensions of EASY200-EASY in mm (for dimensions in inches see Table 3)

197

Page 201

Technical Data

45

110

90

50

102

10.75

4.5

M4

47.5

35.75 71.5

56.5 58

198

08/00 AWB2528-1304-GB

Figure 3: EASY412-... dimensions in mm (for dimensions in inches see Table 3)

Page 202

General 16.25

75

16.25

45

110

90

102

M4

4.5 47.5

107.5

56.5 58

Figure 4: EASY600 dimensions in mm (for dimensions in inches see Table 3)

08/00 AWB2528-1304-GB

Table 3: Dimensions in inches mm inches mm inches

4.5

0.177

56.5

2.22

7.5

0.295

58

2.28

10.75

4.23

71.5

2.81

16.25

0.64

75

2.95

35.5

1.4

90

3.54

35.75

1.41

102

4.01

45

1.77

107.5

4.23

47.5

1.87

110

4.33

50

1.97

199

Page 203

Technical Data Ambient climatic conditions (Cold to IEC 60 068-2-1, Heat to IEC 60 068-2-2) Ambient temperature Installed horizontally/vertically

–25 to 55 °C, –13 to 131 °F

Condensation

Prevent condensation with suitable measures

LCD display (reliably legible)

0 to 55 °C, 32 to 131 °F

Storage/transport temperature

–40 to +70 °C, –40 to 158 °F

Relative humidity (IEC 60 068-2-30)

5 to 95 %, non-condensing

Air pressure (operation)

795 to 1080 hPa

Corrosion resistance IEC 60 068-2-42

SO2 10 cm3/m3, 4 days

IEC 60 068-2-43

H2S 1 cm3/m3, 4 days

Ambient mechanical conditions Pollution degree

2

Degree of protection (EN 50 178, IEC 60 529, VBG4)

IP 20

Oscillations (IEC 60 068-2-6)

10 to 57 Hz (constant amplitude 0.15 mm) 57 to 150 Hz (constant acceleration 2 g)

Shock (IEC 60 068-2-27)

18 shocks (semi-sinusoidal 15 g/11 ms)

Drop (IEC 60 068-2-31)

Drop height 50 mm

Free fall, when packed (IEC 60 068-2-32)

1m

Electrostatic discharge (ESD), (IEC/EN 61 000-4-2, severity level 3)

8 kV air discharge, 6 kV contact discharge

Electromagnetic fields (RFI), (IEC/EN 61 000-4-3)

Field strength 10 V/m

Radio interference suppression (EN 55 011, EN 55 022)

Class B

Burst (IEC/EN 61 000-4-4, severity level 3)

2 kV power cables, 2 kV signal cables

High-energy pulses (surge) “easy”-AC (IEC/EN 61 000-4-5)

2 kV power cable symmetrical

High-energy pulses (surge) “easy”-DC (IEC/EN 61 000-4-5, severity level 2)

0.5 kV power cable symmetrical

Line-conducted interference (IEC/EN 61 000-4-6)

10 V

200

08/00 AWB2528-1304-GB

Electromagnetic compatibility (EMC)

Page 204

General Dielectric strength Measurement of the air clearance and creepage distance

EN 50 178, UL 508, CSA C22.2, No 142

Dielectric strength

EN 50 178

Tools and cable cross-sections Solid min. 0.2 mm2, max. 4 mm2/AWG: 22 – 12

Flexible with ferrule min. 0.2 mm2, max. 2.5 mm2/ AWG: 22 – 12 Factory wiring: up to AWG 30

Slot-head screwdriver, width

3.5 0.8 mm, 0.14

Tightening torque

0.6 Nm

Backup/accuracy of real-time clock (only with “easy”-C) Clock battery back-up at 25 °C/77 °F

Normally 64 h at 40 °C/104 °F

Normally 24 h

Accuracy of the real-time clock

Normally - 5 s/day, ~ - 0.5 h/year

Repetition accuracy of timing relays Accuracy of timing relays

- 1 % of value

Resolution Range “s”

10 ms

Range “M:S”

1s

Range “H:M”

1 min.

Retentive memory Write cycles of the retentive memory

100 000

08/00 AWB2528-1304-GB

Circuit connections (basic units) EASY412

41

EASY600

121

201

Page 205

Technical Data Power supply

EASY412-AC-..., EASY61.-AC-R.. EASY412-AC-...

EASY61.-AC-R..

Rated value (sinusoidal)

115/120/230/240 V AC

100/110/115/120/230/240 V AC

+10/–15 % 90 to 264 V AC

+10/–15 % 85 to 264 V AC

50/60 Hz, - 5 %

50/60 Hz, - 5 % at 115/120 V AC 60 Hz

Normally 40 mA

Normally 70 mA at 230/240 V AC 50 Hz

Normally 20 mA

Normally 35 mA

20 ms, EN 61131-2

20 ms, EN 61131-2 at 115/120 V AC

Normally 5 VA

Normally 10 VA at 230/240 V AC

Normally 5 VA

Normally 10 VA

Operating range Frequency, rated value, tolerance Input current consumption

Voltage dips Power loss

EASY412-DA-..., EASY412-DC-..., EASY61.-DC-R.., EASY62.-DC-T.. EASY412-DA-...

EASY412-DC-...

EASY61.-DC-R.., EASY62.-DC-T..

12 V DC, +30 %, –15 %

24 V DC, +20 %, –15 %

Rated value Permissible range

10.2 to 15.6 V DC

20.4 to 28.8

20.4 to 28.8

Residual ripple

-5%

Input current at 24 V DC (with EASY412-DA-... 12 V DC)

Normally 140 mA

Normally 80 mA

Normally 140 mA

Voltage dips

10 ms, EN 61131-2

Power dissipation at 24 V DC (with EASY412-DA-... 12 V DC)

Normally 2 W

Normally 2 W

Normally 3,5 W

202

08/00 AWB2528-1304-GB

Rated voltage

Page 206

Inputs Inputs

EASY-412-AC-..., EASY61.-AC-R.. EASY-412-AC-...

EASY61.-AC-R..

Digital inputs 115/230 V AC Number

8

12

Status display

LCD (if provided)

LCD (if provided)

To power supply

No

No

Between each other

No

No

To the outputs

Yes

Yes

0 to 40 V AC

0 to 40 V AC

Electrical isolation

Rated voltage L (sinusoidal) 0 signal

79 to 264 V AC

79 to 264 V AC

Rated frequency

1 signal

50/60 Hz

50/60 Hz

Input current with 1 signal R1 to R12, I1 to I6 (EASY61. also I9 to I12)

6 0.5 mA at 230 V AC 50 Hz, 10 (12) 0.5 mA at 230 V AC, 6 0.25 mA at 115 V AC 60 Hz 50 Hz 10 0.25 mA at 115 V AC, 60 Hz

Input current on 1 signal I7, I8

2 6 mA at 230 V AC 50 Hz, 2 4 mA at 115 V AC 60 Hz

2 6 mA at 230 V AC 50 Hz, 2 4 mA at 115 V AC 60 Hz

Delay time for 0 to 1 and 1 to 0 for I1 to I6, I9 to I12 Debounce ON

80 ms (50 Hz), 66n ms (60 Hz) 80 ms (50 Hz), 66n ms (60 Hz)

Debounce OFF (also R1 to R12)

20 ms (50 Hz), 16n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz)

Delay time I7, I8 for 1 to 0 Debounce ON

160 ms (50 Hz), 150 ms (60 Hz) 80 ms (50 Hz),66n ms (60 Hz)

Debounce OFF

100 ms (50 Hz/60 Hz)

20 ms (50 Hz), 16n ms (60 Hz)

Delay time I7, I8 for 0 to 1 Debounce ON

80 ms (50 Hz), 66n ms (60 Hz) 80 ms (50 Hz), 66n ms (60 Hz)

Debounce OFF

20 ms (50 Hz), 16n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz)

08/00 AWB2528-1304-GB

Max. permissible cable length (per input) I1 to I6, R1 to R12 (with EASY61. also I9 to I12)

Normally 40 m

Normally 40 m

I7, I8

Normally 100 m

Normally 100 m

203

Page 207

Technical Data EASY412-DA-..., EASY412-DC-..., EASY6..-DC-... EASY412-DA-...

EASY412-DC-...

EASY6..-DC-...

8

8

12

Digital inputs Number

2 inputs (I7, I8) usable as analog inputs Status display

LCD (if provided)

Electrical isolation To power supply

No

No

No

Between each other

No

No

No

To the outputs

Yes

Yes

Yes

Rated value

12 V DC

24 V DC

24 V DC

0 signal

4 V DC (I1 to I8)

5 V DC (I1 to I8)

5 V DC (I1 to I12, R1 to R12)

1 signal

8 V DC (I1 to I8)

8 V DC (I7, I8)

8 V DC (I7, I8)

Rated voltage

15 V DC (I1 to I6)

15 V DC (I1 to I6, I9 to I12, R1 to R12)

3.3 mA at 12 V DC (I1 to I6)

3.3 mA at 24 V DC (I1 to I6, R1 to R12)

3.3 mA at 24 V DC (I1 to I6, I9 to I12, R1 to R12)

1.1 mA at 12 V DC

2.2 mA at 24 V DC

2.2 mA at 24 V DC

Debounce ON

20 ms

20 ms

20 ms

Debounce OFF

Normally 0.3 ms (I1 to I6)

Normally 0.25 ms (I1 to I12)

Debounce ON

20 ms

20 ms

Debounce OFF (with EASY412-DC-... and EASY6..-DC-... also R1 to R12)

Normally 0.3 ms (I1 Normally 0.4 ms (I1 Normally 0.4 ms to I6) to I6) (I1 to I6, I9 to I12) Normally 0.15 ms (I7, Normally 0.2 ms (I7, Normally 0.2 ms (I7,

Input current on 1 signal

I7, I8 Delay time for 0 to 1

Delay time for 1 to 0

204

100 m

100 m

100 m

08/00 AWB2528-1304-GB

Cable length (unshielded)

20 ms