Page 1
Model 325 URICA™
Universal Remote Interface For Control & Acquisition User's Manual
SZ
[MOORE
®
UM325-1 issue 2 October 1995
Page 2
UM325-1 CONTENTS
TABLE OF CONTENTS
SECTION CONTENTS PAGE T INTRODUCT ION (ooo. cccccccecccccceneeces cece eeec cent eee eceecceecnaeecsensesacsaceaeeeeeceeecsscuseeeeesuaneesseeeeeeaeeeaeeeeeeeeeeeeeeee 1-1 1.1. SECTION CONTENTS 00.0 occcccccceec cece ceecceeeeeeenseecaeesaesacessaeesecscenscecserersessseetsaecsseseeeeesseeeesesaees 1-1 1.2. PRODUCT DESCRIPTION ooo. ccee cee cecc cence sceeeeeeeeceeeeeeseeeeeesecesaecaeecseeesaeseeeeeeeeeeeeseeseesees 1-1 1.3. PRODUCT SUPPORT ...000.00....0. ccc ceecee ccc cece ee cec eee eeceeeeeaececeegeecegeceeeseecsaeseeesesseceqesenessatesaeerieeripeaees 1-2 Zo INSTALLATION .o.c.cccccccccccccceteeeecessseeeeeeneeeeseeeneeeeeeeenseeceseeaeecaeecseecascaseanseascssessaesesssaesaaseuseessetenseciscegs 2-1 2.1. EQUIPMENT DELIVERY AND HANDLING 0000 ect eeeeerneeeneeceneereereeseatenatennetnienniee 2-1 2ZLD. Factory SRIipme nt... ccc ccceceeseeesectscenneeneecessessaessaeeseeveeesessseesaesiaessaesessesiaessaeesseseneseeeeaeeeaes 2-1 2.1.2. Receipt of Shipment... cccccceeeeee eee eeeenee cece stneenecennccneesaeessesnsepseeeeseeetiaeeaesesceseseaeeeaeeasens 2-1 QAB. SEOTAU ZC ooo ccccccccccccccscescceceeenssseeseusaeeesesneeseusascceccssssusesessaasssessseeecesneeecensaeeesesesaseeeeesesssecesetseseseasees 2-1 2.1.4. Return Shipment occ cccccccccccce sent eeee eee eens cesecessesnnecesecesceeeeaecnsessaessaeeeeseatesiserasseadeeceeecneeteeseees 2-1 2.2, ENVIRONMENTAL CONSIDERATIONS 0000000 cccececesecenccerecneccneeceaeesneeeeesearetaeepseesaessaeenaeed 2-2 2.3. INSTALLATION .......0...0.cccccccccccccesceescensececeeseecensscsescaceenssccseessaesaceaeenaeeneeeseeeessceeeeseeessseegeesssseseseateesers 2-2 2.3.1, Installation Considerations ...0.00.000000ccccccccccc cece cece cee eeeeeeee ee ceeeeeennecneeeeeeeeeesesaessscaaeeeeeeeeeeecesessesseeeees 2-2 2.3.2, Mechanical Installation .........cccccccccccccce cece cece cec cc ceenaseessesesassensesensesesseccusssenvnssessasensscenssetensiesaaees 2-3 2.3.3. Electrical [ristallation ....0.0..cccccccccccccccsse sets eeesscesss te censeeesssesssseseseeenneeeaneecesseeaennesesascessesssarenanessaess 2-4 3. COMMUNICATION SETTINGS ooo. cccecescceseeeeeeeeaecneesaeeasenseeesessaseceaesectecseeesessessaeeneeaee 3-1 3.1. BET SWITCH SETTINGS .0oooo020oceccceccc cece cece ccce ence cee eeeeeeeeaeeeeesecaeceaeesaeecseeenacesuceceeecsaeesaeeeaeeneeesees 3-1 BLD, Switch Dice cce cece cnet ence cnee cee ceneeeneeeneesbeeteeeenaeeceesseessesseseaesaseseaeseeesaceeeseaseecieeusestieeeaeeseeens 3-1 BAZ. Switch 2 ooeeccccccccccccccescceessecsssseccennecssecessecesseeesnsneeesneeesnsaesneesnsscaeesenesessaeeseaaeeeeeecetsusensuseneersrsaeerss 3-1 BL3. SWHEN 3 oie cceccee cee cec cece eee cece ce ceecoecneesececeeceecceaeesaaccsccsapescseeseeesaeenageceecciaseseeseeccnseesseesensenireess 3-4 3.1.4. Switch 4 - MODBUS Address Selection ......0.00.0cccccccccc cece tec cece sc ee see tee es eeesaeccccssneeenennesenenineen 3-6 4. MODBUS COMMUNICATION S.............cccecceccceccececcseecesscescesascesessesaeseessaeessseseesaeesseceaseasecasenseenees 4-1 4.1. DESCRIPTION. .........0.ccccccecccscecsetseeeeeeeeceeseessccnsecncescesscnsecascaaeceeeraceseccsaeessseaseesnsepssscaassasseassaaseeaees 4-1 4.2, MAPPING 0.0... ccccccccccccceessceessecssesseesseeeseesseesaeessecscesseesasessepscecseerseersessaesssessaecesuespaeesaeessersssessepensaees 4-1 4.3. MESSAGE FORMATS |...o..ceeeccccccccccceccececeeneceeeceseesecneeneensesevaeeneceecaecnscusesaeecaycaaeueseaeseesaeeneeseteetess 4-2 4.3.1, Read Coil States... .eccccccceccceccc cece cece cece eee e eee eenaeceeeeceeeeseeenseesecusesusesaeecseesaeenaeecneesseeeeesereeeeeeeens 4-2 4.3.2. Read Tnput Status... ccc ccc tcc cee ceee sce eceeeceeceeecnsccaeteeeeeescieesaasnseeeesseesseeesseeeseseseee 4-2 4.3.3, Read Holding Registers ......0...cccccccccsccscssessceccsecssssseensessevsessesseceueccesesssossesedeeeusseessesseserserseeneenes 4-2 4.3.4. Read Input Registers ......cccccccccccccccestsetsseeseeeneeneesteeeeesaeessesnseseeeeeeceessaeeseeacearevseessessaespaeenaeenaees 4-2 4.3.5, Force Single Coil ...ccccccccccccccccscccsssscsccseeccsccenneecsneeeesrceecseeesseeensessssssesssesssetesnnesestseceeaneeenateenaeeenatess 4-2 4.3.6. Preset Single Register .......00.......c0ccccccccccecccceeeeceee ee cee ee eeaeeeeaee eee eeceeeeceseseeeeseaaeeseeeseseaeeeeeeeseeeneeees 4-2 4.3.7, Loopback Test ...........cccccccccececcccevceeceeeseencecnecceneeasecseeecsaeeceesecuscesseesecsscecseensseueesssasssessseeasenseeeeaes 4-3 4.3.8, Preset Multiple Registers ..........cccccccccccccccseccecceceesccescesecaceencecescessirssssieeeseessecesevsssessessesesaseneesesees 4-3 4.3.9, Report Slave E.De icc cccccccccecccsccctteeeneeeeeeneccnseeseecnseccseesesesseeesecseusaesieesaaeeaesssceesiaeeneesaespaeepseeeasensees 4-3 4.4. MODBUS ERROR CODES... cece ence test cess cnsecesesueenseesseesaecaeesassceceerneeseeeeeseseaeeesesnaeseenas 4-3 5, MAINTENANCE... cccccecccecceenescenceneccneeseccseeseesrerssecsngesssceserraseneceneeneceaeenteesteseseteneeennssisesestsestesseess 5-1 5.1. PREVENTIVE MAINTENANCE ...000.....0ccccccccccccccccceeceneeccescceceneeeaeeeeeneeeaseccsecenesseesensessaesseesueessaesas 5-1 SDD, CLOQninagy ooo cece cece ccceccceeeence cece eeeeneeeeeeeeeeeeaneeetesceceeeeseaaeeeesceeseseeesceereeeeseesuseeeeeesaeeeeeeeneeetesteeeeees 5-1 5.1.2. Visteal Inspections .....0..0.c.cccccccccccceeceec ces cec cee cecceneensecneceeeneeeseeseensenessteseesesatenteecseseesnesnesesaeaeeaeeeeeaeeess S-L §,2. CIRCUIT BOARD HANDLING 0.0 cecccer cere recceeenaeenaeeneeensessnasenevenesseeeeeneteneeneenieens 5-1 5.3. FUSE LOCATION 0000. ccceceececesececneeenseeneeceneesnecsarenseccecseesaseceecessenuapeneeceneceteriesrissniersarras 5-1 5.4. TROUBLESHOOTING ooo. cccceeeceeeneeenecceseeenesessesausececaeeeaaeeaeceeeesaeseaeeeeeeneeeneseeenteniens 5-2 5.4.1, MODBUS Communication ....000.0ccccccccccccce cece cece eeenenceeacceseteaeeenecaceseceesceseseeseeseadcneeeeseeeeteneeeeees 5-2 5.4.2, HART Communications ..0.....000cccccccccccccecc ccc ceee cess eens eeee tes seteneeeeneeseneeeeseeeeevoreesesssesneseueeeeenieeseeeeese 5-2 5.5. BOARD REPLACEMENT 0000. cence ccnneceeeeneernseresriesiscsiecnaeceasseaeenageeescnseeseessaeeeeeereens 5-3 5.6. RECOMMENDED SPARE AND REPLACEMENT PARTS |... eecececersteeeeeeaeeraeenseenes 5-5 5.7. SOFTWARE COMPATIBILITY IDENTIFICATION. ooo... ccccccceeeeecetsesesetteeeteeteerneeeaeeeee 5-5
October 1995 i
Page 3
CONTENTS UM323-]
5.8. MAINTENANCE RECORD 00000000 oocccecccccccccceceeesescseeessuessaeeseseceseesesacecseeecssesscseseeaeeseseeeesaeenes 5-5 6. MODEL DESIGNATION AND SPECIFICATIONS ....0.0......0.00ccccccccceccesccenseceeeeecuseeeseeeecseeceneeeeeeeees 6-1 6.1. MODEL DESIGNATION oc cccccccccccscsccssecsseeccsesceneeeecsseecsssecsceeecsscecsscccsseverseserteeasscrssseenaesesesensasens 6-1 6.2. ACCESSORIES ooo. o.occcccccccccccccssccesscenseeesesceseecsaeeceeeeeseeevsaneeseeeesseeeseecteeecneeeceitesereeessueeeneeeseeeeeeeeees 6-2 6.3. SPECIFICATIONS 20000. ..c0cc ccc ccccecccccccccnsecenseceseccessseesuseeesaseceaeeesaeecseeesaeesessesaseceseeeesnesenseesneeenneeess 6-2
O.BD, Mecnanical 2.0.00... ccccccccceccccceenc cc ceneeeecceee cece eeebccenneeeescsuseeeeeeeeeeeeseeeessesuueessaueesescauaeseessaeesseeaaeeeeenaes 6-2
G.3.2. FLO CHriCal o.oo... cccccccccccccccceececccnncecensceecseeseeccseececcensaeececccsaaeseceeneceseenteessnetesensaesessssaeseessaeeeeesaeeeeenae’ 6-3
6.3.3. COMMUNICATIONS o.oo cccccccccccccccseccccceceeeeveneeecsscceusuenseeeeceeeeccececerseneceesseccstssstseeeeeesneaasaeeseeseepbasaasseseeees 6-4
6.3.4. Emvirorrmental .00.....0.cccccccccccccccccsccseescecessceceeenceceecssneeesscaeeecseaeeecesaeeeccsereeceneaseeseesaceesessesseseeaaeeeeaes 6-4
6.3.5, Electrical Classifications: ..0...0.ccccccccccceeeeeeeceeneene ener tee eeeneceeceeeseeseeseceaeceseeesaecaeseeeeaseeceestaaseneaaeeees 6-4 APPENDIX A MODEL 325 URICA DATABASE LAYOUT ...0.0.....ccccccccccccceccesseseeessseeeesenteeeseeaes A-1 APPENDIX B MODEL 325 URICA STATION DAFA ooo. cceccccccceccesseeeccessceecssseeessnseteseeseeeeesaters B-1 APPENDIX C MODEL 348 MODBUS MAPPING .....00....cccccccccccsccsscceneeersccesneeecnseecaeeccseecesetenseeerseees C-l APPENDIX D XTC TRANSMITTER MODBUS MAPPING ..000000000ccccccccecccceetscecesseceeesssaseenseeeees D-1 APPENDIX E GENERIC TRANSMITTER MODBUS MAPPING. .................ccccccsscecesseceseeeereeeseeenrsees E-1 APPENDIX F BIT MAPPED WORDS ..........cccccccecccccceceeseeeeeensceecesseeseessneeeessaceecesaaeecessaeeeeenuecesennatees F-1 APPENDIX G CABLE CAPACITANCE AND MAXIMUM LENGTH .........0.0000cccccccceeserseeeteeeens G-1 WARRANTY ooicccccccccccccccccccccccccececeeseepseseeeeeseseseseeeeueaeaeeeasssseseeeeeeeneseuseauaaauaaauasaausuaeaaasagasagaaaaeeaaags W-l PARTS LIST oooooooeccccccccccccceccccccccsccccceeceeeeeseeecessssescssneeeeesseececeseessensessssccsseeecessssecccsrectecsssestsessesenaass PL-1
LIST OF ILLUSTRATIONS FIGURE AND TITLE PAGE 1-1 Typical Application ..2..0.0. 0.0 cect ccs cceeccseeeeeseeeseeesseseeseesseecneesneeeneseneseneessesseeeseseneseoses 1-2 2-1 Mounting Diagram... cece ccceceeeeetentecieeseeeaecaeeeeeseeseesneseeseeseeseesseeseeseeeeseesesaeaseveesinseenage 2-4 2-2 URICA Faceplate... cece ces e ence erecceeecee ners ceeeeseaeeseaceseaeeseeesesaeeseeaseuaseseseceneseseseseueeeeneasenees 2-5 2-3 URICA to Model 348 Conmections.......0.00....c0ccccccccc ccc cccesceeccceeeeeeeseeeceeeeeeeeeeeccccneeeeeseeenpeaauuaeeeeeeeneengea 2-6 2-4 URICA to Field Transmitter Connections, Hazardous Location............00.000000000ccccccescesnsecceeeneeeees 2-6 2-5 URICA to Transmitter-Controller Connections, Hazardous Location ........................::-:::ceeeeee 2-7 3-1 Model 325 URICA Bit Switches .......0.0000.0.cccccccccccccccseccessceccssceesstesesseesaeersaeeesaseesasessassesnevsnseeenneeents 3-3 5-1 URICA Exploded View 0.0.0.0... ccccccccccseeeeseeeeeeeneceeesiesassveeeeeeaneresseeeecieceeccecesasesesensseasesseeeseseneeeeees 5-4 6-1 Dimensions .0.....0....0. cece ccc cecceeeseeececeaseeeasssecsssceceseaaseeecensececeaaseesesaseeceesaeesessuaeeseeateeesenteeteeuanetees 6-3 LIST OF TABLES il October 1995
Page 4
UM325-1 CONTENTS
TABLE AND TITLE PAGE 2-1 Terminal Assignments .....00..00.000 cc ccccceccceseesseccneeeneeeneeeaeeeaesnecsaccescesseesiespasesaeesaeceseceseesiasessecnaesseeenees 2-5 2-2 HART Two-Wire Cable... ccc cee ceeeeeeecseeceecescnsceeecsessesssssasenseaeseesnesnesereecsseneseesneseneease 2-6 2-2 URICA Serial Port Layout ...00.000 ce ececeeeccesneeeeessneeesersersesseeserssaersceesneesessessesesssueeseesanessesasees 2-6 2-4 RS422 Comme ction... ccc ccee een eeneenseeeeeeneecneeseeeseeeessaeetsessaetiaeeseesesessaeseteetetespeeeaseaceeseees 2-7 2-5 RS485 Comme ction 0.0.0.0... ccceeeeenneeeeeeneeecenssacecesseaeepenteeeevsneserssaeeecesssaeeececccteeecceseeseeeeneeeetecaees 2-7 3-1 Baud Rate Selection .00.......000 cee cece eeeeeeeecensssaasenesascnensseessenscepsseeeeseenaeasecgcseeeeceesaeeeeeseeteesseees 3-1 3-2 Data Bits... eee ceccecesceceesececceeceeceeececeeeveceaaeaceuaauaaesessevecsressecceseeecsaeanceseceessseseeavaeeeneentenseeeeats 3-2 BeB Parity cece seeeeeeeeseeesccesseesseessecssecseceseesapereeceeecesccasesseesassaesnaeseeesneeesscerscessceaeseesaseessecsserseeneees 3-2 3-4 Computer Port Configuration ................0...0..0 cece cece cece cence cece cece eeneeeeeeecesceeypeeeseaeeaeseeeeneeseieseaees 3-2 3-5 DTE/DCE Terminal Setting .....0..0..00 0c eee ceccesecsecseccscsensevserseesesseesecrsceesevsessssnasesvaeceeeseceaesisnaenes 3-4 3-6 2-Wire or 4-Wire Mode ...................cecceeceecceceeee cece ceeeseeeeneeeneeeeeeaeseseeneeennssecscesscenaeeseeseecirerseseessenees 3-4 3-7 CTS Hardware Handshaking ..00.....000.00 0 cccccccccccssesssesseceevesssseessesseeesescccsesssessaeesesnaeresdesienstspnasraeey 3-4 3-8 Protocol 2.2.0.2... cece cece eeeeceeceseeeaaeeaeeesseeaaeseeesesessensessesasesesesaseaaessaseseeseseseessaasaasasecereriseetsseerees 3-5 3-9 MODBUS Address Selection 0.0.0.0... cc cccccccccecc ree cescteereenecnsenecnsenseeneenessssensenssenseneeseenerenessasasessees 3-6 4-1 MODBUS Exception Response Codes 20.0.0... cccccccetccerereeceeeeeneeeeceenieeeaesenerseseneseeeeetiennieniteneees 4-4 5-1 LED Maintenance Indicators 00.00.00... 0cccccccc cece cnscceneseneenseneensensesnecnecestensensenseeneensenserseriereaaersans 5-1 6-1 Model 325, Model Designation .........0.0....00.00.0 cece cee ceeeseeeeeecesceeseseeeseeecassesaecsaseseenasenseeeeseensecesees 6-1 6-2 ACCOSSOTICS 00... ccc cect eeercerectecssersceseseesseeussesseeseissiecsenrcssecsecesceacsseeeesseceesseenserscesssnsseseesesnernes 6-2
CHANGES FOR ISSUE 2, OCTOBER 1995
Section 1.3 Product Support added.
In Section 2, installation wiring Figures 2-3, 2-4, and 2-5 have been added.
In Section 3.1.4, Table 3-9 and the related example have been corrected.
October 1995 ili
Page 5
CONTENTS
UM325-1
1. INTRODUCTION
1.1. SECTION CONTENTS 1.2. PRODUCT DESCRIPTION
1.3. TABLE OF CONTENTS iv
October 1995
Page 6
UM325-1
CONTENTS
2. INSTALLATION
2.1.
2.2. ENVIRONMENTAL CONSIDERATIONS 2.3. INSTALLATION 2.3.1. Installation Considerations 2.3.2. Mechanical Installation 2.3.3. Electrical Installation 3. COMMUNICATION SETTINGS 3.1. BIT SWITCH SETTINGS 3.1.1. Switch 1 3.1.2. Switch 2 3.1.3. Switch 3 3.1.4. Switch 4 - MODBUS Address Selection 4. MODBUS COMMUNICATIONS 4.1. | DESCRIPTION 4.2. MAPPING 4.3. MESSAGE FORMATS
EQUIPMENT DELIVERY AND HANDLING
2.1.1. Factory Shipment 2.1.2. Receipt of Shipment 2.1.3. Storage
2.1.4. Return Shipment
4.3.1. Read Coil Status
4.3.2. Read Input Status
October 1995
Page 7
CONTENTS
UM325-1
4.3.3. Read Holding Registers 4.3.4. Read Input Registers 4.3.5. Force Single Coil
4.3.6. Preset Single Register 4.3.7. Loopback Test
4.3.8. Preset Multiple Registers
4.3.9. Report Slave I.D.
4.4. © MODBUS ERROR CODES MAINTENANCE 5.1. PREVENTIVE MAINTENANCE 5.1.1. Cleaning 5.1.2. Visual Inspection §.2. CIRCUIT BOARD HANDLING 5.3. FUSE LOCATION 5.4. TROUBLESHOOTING 5.4.1. MODBUS Communications 5.4.2, HART Communications 5.5. BOARD REPLACEMENT 5.6. RECOMMENDED SPARE AND REPLACEMENT PARTS 5.7. SOFTWARE COMPATIBILITY IDENTIFICATION 5.8. MAINTENANCE RECORD
MODEL DESIGNATION AND SPECIFICATIONS
6.1.
MODEL DESIGNATION v1
October 1995
Page 8
UM325-1
CONTENTS
6.2.
6.3.
ACCESSORIES
SPECIFICATIONS
6.3.1.
6.3.2.
6.3.3.
6.3.4.
6.3.5.
Mechanical
Electrical
Communications
Environmental
Electrical Classifications
October 1995
Vii
Page 9
UM325-1 INTRODUCTION
1. INTRODUCTION
This User’s Manual is for the Model 325 Universal Remote Interface for Control and Acquisition (URICA™). It contains installation, hardware configuration, and maintenance procedures.
IMPORTANT
Save this User’s Manual for installing, configuring, operating and servicing a Model 325 URICA.
1.1 SECTION CONTENTS
This User’s Manual is divided into six sections as follows: Section 1, INTRODUCTION, provides an overview of URICA.
Section 2, INSTALLATION, provides general installation considerations, environmental considerations, and mounting and wiring guidelines.
Section 3, COMMUNICATION SETTINGS, describes the communication settings for the available protocols. Information on DIP switch settings is included in this section.
Section 4, MODBUS COMMUNICATIONS, provides a description of the MODBUS mapping and message formats.
Section 5, MAINTENANCE, furnishes preventive maintenance guidelines, troubleshooting, and subassembly replacement procedures.
Section 6, MODEL DESIGNATION AND SPECIFICATIONS, provides information on model designation and specifications.
1.2 PRODUCT DESCRIPTION
The Model 325 Universal Remote Interface for Control and Acquisition (URICA) interfaces remote HART® field devices to a variety of central control systems such as DCS, PLC, MODBUS masters, and general purpose computer. Through URICA, the user can communicate with field devices to send commands to the Model 348 FIELDPAC™ field mounted controller to change setpoints or request process or station data. URICA also provides an interface to the XTC™ line of transmitters to obtain process information, range limits, damping, and loop data from transmitter-controllers.
The front panel faceplate, shown in Figure 2-2, contains LED status lights, all terminal connections, and an RS232 port. Asynchronous communications between URICA and a user's control system can be via either RS232, RS422, or RS485. DIP switches on the circuit board are set to establish communications format.
URICA can be mounted in an industrial enclosure, instrument cabinet, or on a desk.
October 1995 1-1
Page 10
INTRODUCTION UM325-1
The Model 325 URICA is designed for ease of installation. Simply connect URICA to multi-drop HART field devices with unique polling addresses, and turn URICA on. The 325 will automatically find the transmitters and start polling information from them.
Operator Interface
RS422 Model 325 MODBUS Slave 1 Model 325 MODBUS Slave 2 URICA HART XTC J 2 || Model XTC | 348 XTC »]'| Model \ | | 348
FIGURE 1-1 Typical Application
1.3 PRODUCT SUPPORT
Product support can be obtained from the Moore Products Co. Technical Information Center (TIC). TIC is a customer service center that provides direct phone support on technical issues related to the functionality, application, and integration of all products supplied by Moore Products Co.
To contact TIC for support, either call 215-646-7400, extension 4TIC (4842) or leave a message in the bulletinboard service (BBS) by calling 215-283-4968. The following information should be at hand when contacting TIC for support:
e Caller ID number, or name and company name
When you call for support for the first time, a personal caller number is assigned. This number is mailed in the form of a caller card. Having the number available when calling for support will allow
1-2 October 1995