Page 1 of Model 325 URICA Universal Remote Interface for Control & Acquisition User's Manual

Manual · Moore

Model 325 URICA Universal Remote Interface for Control & Acquisition User's Manual

Manual74 pagesPDF 1.9 MB

User's manual for the Moore Model 325 URICA, an interface linking remote HART field devices to DCS, PLC and MODBUS control systems.

Download the PDF1.9 MB

Covers · 1 model

The models it covers

Summary

What is in it

The Moore Products user's manual for the Model 325 Universal Remote Interface for Control and Acquisition (URICA), which connects remote HART field devices such as the Model 348 FIELDPAC controller and XTC transmitters to central control systems. It covers installation, DIP switch communication settings, MODBUS mapping and message formats, maintenance and troubleshooting, model designation and specifications, plus appendices with database layouts and MODBUS maps.

Its parts

  1. Introduction
  2. Installation
  3. Communication Settings
  4. MODBUS Communications
  5. Maintenance
  6. Model Designation and Specifications

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Moore Products user's manual (UM325-1, issue 2, October 1995) for the Model 325 URICA, a Universal Remote Interface for Control and Acquisition that links HART field devices to central control systems such as a DCS, PLC, MODBUS master or computer. It covers installation, communication switch settings, MODBUS commands, maintenance, troubleshooting and specifications. Every page is a scan read by OCR.

Read for this summary: pages 1 to 4, 9 to 10, 13 to 15, 31, 33 to 35, 37, 39 to 42 and 73 of 74.

Device
Interface between HART field devices and a DCS, PLC, MODBUS master or general purpose computer p. 9
Protocol
MODBUS RTU slave p. 42
Computer port
RS232, RS422 or RS485 p. 41
Baud rates
115,200; 57,600; 38,400; 19,200; 9600; 2400; 1200; 300 p. 41
Power
19-28 Vdc, galvanically isolated, 5 Watts maximum p. 39, 40
Connections
RS232 on a DB9 female connector; RS422, HART and DC power on plug-in screw terminals p. 42
Serial settings
Parity even, odd or none; RS232 port set as DCE or DTE by switch p. 41, 42
Operating temperature
-40 to 75°C (-40 to 167°F) p. 42
Accessories
15124-1 power supply (24 Vdc, 2A); 16260-27 15 ft straight-through shielded cable; 16801-9 adapter to DB25F; 14700-121G 120 ohm RS422/485 terminating resistor p. 40
Spare parts
16260-41 main circuit board; 7447-214 power supply fuse, 125 Volt, 5 Amp p. 73
Maintenance kit
15545-110 kit with wrist strap and conductive mat, required when removing or installing the board p. 35
Status LEDs
RDY, CMD RCV, HRT SNT and ACT on the faceplate p. 34
Model number
Sample 325H D N N N A F: 325H basic station with HART, D 19-28 Vdc supply, A current design p. 39
Approvals
The manual states FM/CSA approval, Class I, Division 2, Groups A, B, C and D p. 39, 42

What this manual walks you through

  • Receiving, storing and returning the unit p. 13, 14
  • Choosing a location and mounting with 1/4 inch bolts p. 14, 15
  • MODBUS loopback, preset multiple registers and report slave ID commands p. 31
  • Cleaning and visual inspection p. 33
  • Replacing the power input fuse p. 33, 34
  • Troubleshooting MODBUS and HART communication with the LEDs p. 34, 35
  • Replacing the circuit board p. 35
  • Ordering spare boards and checking software compatibility p. 37

Good to know

  • The air around an operating unit must stay below 75°C (167°F). p. 15
  • Installation must conform to the National Electrical Code and other applicable codes. p. 13
  • Floating point or double integer values that use two registers need Preset Multiple Registers; Function Code 06 will not work. p. 31
  • A board out of the unit must be kept in a static shielding bag. p. 35
  • One spare fuse and circuit board is recommended for every 1 to 10 units in service. p. 37

Questions this manual answers

What power supply does the URICA Model 325 need?

19-28 Vdc at 5 Watts maximum; the accessory list offers the 15124-1 general purpose 24 Vdc, 2A supply. p. 40

Why is the URICA HRT SNT LED blinking about once a second?

The URICA is not communicating with the HART devices; recheck the wiring and the current sense resistor across terminals 8 and 9. p. 34, 35

Why is the URICA not talking to the MODBUS master?

Check that the DIP switch settings match the master, check the cable pinout, and set SW2-8 ON when using a modem. p. 34

What fuse does the URICA Model 325 use?

Part number 7447-214, a 125 Volt, 5 Amp power supply fuse. p. 73

Which serial interfaces does the URICA support?

RS232, RS422 and RS485, with MODBUS RTU slave protocol. p. 41, 42

The whole text · 8 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 7471-74

The file

Revision and size

Part no.UM325-1
RevisionIssue 2, October 1995
PublisherMoore Products Co.
Pages74
PDF1.9 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.
UM325-1

The first pages · 3 of 74

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 74
Page 2
Page 2of 74
Page 3
Page 3of 74