The text of a manual · part 7 of 8

Model 325 URICA Universal Remote Interface for Control & Acquisition User's Manual, pages 61 to 70

Pages 61 to 70 of 74

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Moore URICA Model 325

Page 61 read from a scan by OCR; it may hold reading errors

UM325-1 Appendix D

June 1995 D-5

Page 62 read from a scan by OCR; it may hold reading errors

UM325-1 Appendix E

Appendix E GENERIC TRANSMITTER MODBUS MAPPING

Generic Transmitter: Quick Access REAL Data

Register # Parameter Write

(30 * (PA-1)) + 0001

Primary Variable

(30 * (PA-1)) + 0003

Secondary Variable

(30 * (PA-1)) + 0005

Tertiary Variable

(30 * (PA-1)) + 0007

Fourth Variable

Generic Transmitter: Quick Access Process Variable REAL Data

Register #

Parameter

Write

(4 * (PA-1)) + 0501

Process Variable

Generic Transmitter: Quick Access BOOL Data

Coil # Status Write (60 * (PA-1))+ 01 Transmitter Not Communicating

(60 * (PA-1)) + 02 Field Device Malfunction

(60 * (PA-1)) + 03 Write Command Failed Ww

(60 * (PA-1)) + 04

Configuration Hold

(60 * (PA-1)}) + 05

Database Updating

(60 * (PA-1)) + 06

Error (1=yes)

(60 * (PA-1)) + 07

PV Out of Limits

(60 * (PA-1)) + 08

Non-PV Out of Limits

(60 * (PA-1)) + 09

Analog Output Saturated

(60 * (PA-1)) + 10 Output Current Fixed (60 * (PA-1)) + 11 Cold Start Has Occurred (60 * (PA-1)}) + 12 Spare

(60 * (PA-1)) + 13 Spare

(60 * (PA-1)) + 14

Write Protect Enabled

October 1995

E-1

Page 63 read from a scan by OCR; it may hold reading errors

Appendix E UM325-1

Generic Transmitter: 2 Register REAL Data

Parameter Write Measured Variable MV Range Low WwW MV Range High W Damping

Current

Percent Of Range Lower Sensor Limit Upper Sensor Limit Minimum Span Secondary Variable Tertiary Variable Fourth Variable

Register #

(300 * (PA-1)) + 1001 (300 * (PA-1)) + 1003 (300 * (PA-1)) + 1005 (300 * (PA-1)) + 1007 (300 * (PA-1)) + 1009 (300 * (PA-1)) + 1011 (300 * (PA-1)) + 1013 (300 * (PA-1)) + 1015 (300 * (PA-1)) + 1017 (300 * (PA-1)) + 1019 (300 * (PA-1)) + 1021 (300 * (PA-1)) + 1023

Generic Transmitter: 2 Register DINT Data

Register # Parameter Write

(300 * (PA-1)) + 1151

Device Serial Number

WwW

(300 * (PA-1)) + 1153

Device ID Number

(300 * (PA-I)) + 1155

Sensor Serial Number

(300 * (PA-1)) + 1157

# HART CMDS Sent

(300 * (PA-1)) + 1159

# HART CMDS Failed

Generic Transmitter: Variable Length STRING Data

Register # Parameter Length Write (300 * (PA-1)) + 1165 Hart Tag Name 4 Reg Ww (300 * (PA-1)) + 1169 Descriptor 8 Reg WwW (300 * (PA-1)) + 1177 HART Message Part A 8 Reg Ww (300 * (PA-1)) + 1185 HART Message Part B 8 Reg WwW

Generic Transmitter: 1 Register WORD Data

Register # Parameter

(300 * (PA-1)) + 1233

Device Status

(300 * (PA-1)) + 1234 Spare (300 * (PA-1}) + 1235 Spare (300 * (PA-1)) + 1236 Spare (300 * (PA-1)) + 1237 Spare

(300 * (PA-1)) + 1238 (300 * (PA-1)) + 1239 (300 * (PA-1)) + 1240

Device Error Status | Device Error Status 2 Miscellaneous Status

E-2 October 1995

Page 64 read from a scan by OCR; it may hold reading errors

UM325-1

Appendix E

Generic Transmitter: 1 Register UINT Data

Register # Parameter Write (300 * (PA-1)) + 1259 Poll Address (PA)

(300 * (PA-1)) + 1260 HART Date Month W (300 * (PA-1)) + 1291 HART Date Day Ww (300 * (PA-1)) + 1262 HART Date Year W (300 * (PA-1)) + 1263 Measured Variable Units W (300 * (PA-1)) + 1264 HART Transfer Function W

(300 * (PA-1)) + 1265 Spare (300 * (PA-1)) + 1266 Spare (300 * (PA-1)) + 1267 Spare

(300 * (PA-1)) + 1268

Manufacture ID Code

(300 * (PA-1)) + 1269

Device Type Code

(300 * (PA-1)) + 1270

Sensor Limit Units

(300 * (PA-1)) + 1271

HART Supplier Code

(300 * (PA-1)) + 1272

Database Revision Number

(300 * (PA-1)) + 1273

Software/Hardware Revision Levels

October 1995

E-3

Page 65 read from a scan by OCR; it may hold reading errors

Appendix E UM325-1

E-4 October 1995

Page 66 read from a scan by OCR; it may hold reading errors

UM325-1 Appendix F

Appendix F BIT MAPPED WORDS

This section defines the individual bits in the | register WORD data. The status word data is also stored as coils for each device. Refer to the HART device’s appropriate MODBUS map for coil definitions.

Device Status

Although the word is read as an integer, each bit in this 16-bit word represents a status condition. The bits that can be written to are marked with an appended asterick below. Note that bits 01 thorugh 08 comprise the HART Field Device Status Word.

Bit 01: Primary Variable Out of Limits

Bit 02: Non-Primary Variable Out of Limits Bit 03: Analog Output Saturated

Bit 04: Output in Fixed Current Mode

Bit 05: Reserved

Bit 06: Cold Start Occurred

Bit 07: Configuration Change

Bit 08: Error

Bit 09: 1 = Transmitter Not Communicating Bit 10: Unused

Bit 11: 1 = Square Root Enabled

Bit 12: 1 = Write Command Failed

Bit 13: Unused

Bit 14: 1 = Device Configuration Change Bit 15: 1 = Device Error NAK

Bit 16: | = Device Error

Station Status

This status is valid only for the Model 348 FIELDPAC. Athough the word is read as an integer, each bit in this 16-bit word represents a status condition. The bits that can be written are marked with an appended asterick below.

Bit O01: Active Alarm Exists Bit 02: Alarm Not Acknowledged Bit 03: Flashing Bargraph Bit 04: unused Bit 05: Configuration Hold * Bit 06: Unused Bit 07: Unused Bit 08: Console = 1, Local - 0 * Bit 09: Unused Bit 10: Override Status Output of Function Block 10 Bit 11: Unused Bit 12: Configuration Changed Bit 13: Unused Bit 14: Unused Bit 15: Error Bit 16: Unused Moore Status

October 1995 F-]

Page 67 read from a scan by OCR; it may hold reading errors

Appendix F UM325-1

Although the word is read as an integer, each bit in this 16-bit word represents a status condition. The bits that can be written to are marked with an appended asterick below.

Bit 01: 1 = Auto Rerange Enabled* - not valid for the Model 348 Bit 02: 1 = Local Pushbuttons Enabled - not valid for the Model 348 Bit 03: 1 = Write Protect Mode*

Bit 04-16: Unused

Moore Transmitter Status

This parameter indicates the state of the HART device. The possible states are: 3 = Off-line, 5 = On-line, and 7 = Configuration Hold. If other states are obtained, call your Moore Products Co. respresentative for assistance.

Moore Device Error This parameter indicates the Moore Products Co. device errors.

Device Error Status 1 See appropriate transmitter HART manual.

Device Error Status 2 See appropriate transmitter HART manual.

Miscellaneous Status Bit 06 in this word indicates the the controller is enable for the XTC transmitter.

F-2 October 1995

Page 68 read from a scan by OCR; it may hold reading errors

UM325-1 Appendix F

Loop Status Although the word is read as an integer, each bit in this 16-bit word represents a status condition. The bits that can be written to are marked with an appended asterick below.

Transmitter Loop Status: Bit 01: Auto/Manual Status | = Auto, 0 = Manual * Bit 02-16: Unused

Model 348 FIELDPAC Loop Status: Bit 01: Auto o/Manual Status | = Auto, 0 = Manual * Bit 02: Local Status * Bit 03: Standby Sync Bit 04: External/Internal Status, ] = External * Bit O05: Unused Bit 06: Unused Bit 07: Setpoint Ramp Status * Bit 08: Unused Bit 09: Emergency Manual Bit 10: Configuration Hold Bit 11: High Setpoint Limit Bit 12: Low Setpoint Limit Bit 13: Alarms Out of Service Bit 14 - 15: Unused Bit 16: Auto/Manual Transfer Block Configured

Alarm Status

Although this word is read as an integer, each bit in this 16-bit word represents a status condition. In the Model 348, alarms 1,2,3, and 4 are in Loop 1 Function Block 12. When associated with Loop 2 Function Block 73, the alarms are 5,6,7 and 8. For the transmitter controller, only alarms 1 and 2 are valid, so bits 6-12 are unused.

Bit 01: Alarm 1 Active

Bit 02: Alarm 1 Not Acknowledged *

Bit 03: Alarm 1 Enabled *

Bit 04: Alarm 2 Active

Bit OS: Alarm 2 Not Acknowledged *

Bit 06: Alarm 2 Enabled *

Bit 07: Alarm 3 Active (Model 348 FIELDPAC Only)

Bit 08: Alarm 3 Not Acknowledged * (Model 348 FIELDPAC Only Bit 09: Alarm 3 Enabled * (Model 348 FIELDPAC Only

Bit 10: Alarm 4 Active (Model 348 FIELDPAC Only

Bit 11: Alarm 4 Not Acknowledged * (Model 348 FIELDPAC Only Bit 12: Alarm 4 Enabled * (Model 348 FIELDPAC Only

Bit 13: Alarms Out of Service * (XTC with Controller Only)

Bit 14 - 16: Unused

October 1995 F-3

Page 69 read from a scan by OCR; it may hold reading errors

Appendix F UM325-1 Alarm Type The bits in this status 16-bit word determine the type and settings of the alarms. All bits in this word can be edited. Bits; 321 000 -no alarm action required 001 - High Alarm 010 -Low Alarm O11 - High Deviation Alarm 100 - Low Deviation Alarm 101. - Absolute Deviation Alarm 111 -Outof Range Alarm 111 -no alarm action required NOTE XTC with Controller only has the High or Low alarm options. Bits: 54 0 0 - 0.1% alarm deadband 0 1 - 0.5% alarm deadband 1 0 - 1.0% alarm deadband 1 1 - 5.0% alarm deadband NOTE XTC with Controjler only has the High or Low alarm options. Bits: 876 000 -0.0 seconds delay time in 001 -0.4 seconds delay time in 010 -1.0 seconds delay time in O11. -2.0 seconds delay time in 100 -5.0 seconds delay time in 101. - 15.0 seconds delay time in 111 -30.0 seconds delay time in 111 -60.0 seconds delay time in Bits: 1 10 9

1

0 0Q- 0.0 seconds delay time out 0 1-0.4 seconds delay time out

1 O- 1.0 seconds delay time out

1 1 -2.0 seconds delay time out 0 0-5.0 seconds delay time out 0 1 - 15.0 seconds delay time out 1 O- 30.0 seconds delay time out 1 1 -60.0 seconds delay time out

F-4

October 1995

Page 70 read from a scan by OCR; it may hold reading errors

UM325-1

Appendix F

Bits: 12 0 - ring back not required 1 - RINGBACK

Bits 13 through 16 - set to 0

October 1995

F-5