Page 1

®

®

MICRO-INFINITY ICN77000 Series Controller

SERIES

THE NEW STANDARD FOR QUALITY

Operator’s Manual

®

NEWPORT Electronics, Inc. http://www.newportUS.com/manuals

Page 2

Additional Products from ®

NEWPORT Electronics, Inc. THE NEW STANDARD FOR QUALITY

Counters Frequency Meters PID Controllers Clock/Timers Printers Process Meters On/Off Controllers

Recorders Relative Humidity Transmitters Thermocouples Thermistors Wire Rate Meters

Timers Totalizers Strain Gauge Meters Voltmeters Multimeters Soldering Iron Testers pH Pens

For Immediate Assistance In the U.S.A. and Canada: 1-800-NEWPORT® NEWPORTnetSM On-Line Service In Mexico: (95) 800-NEWPORTSM www.newportUS.com Or call your local NEWPORT Office.

pH Controllers pH Electrodes RTDs Thermowells Flow Sensors

Internet e-mail info@newportUS.com

It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that apply. NEWPORT is constantly pursuing certification of its products to the European New Approach Directives. NEWPORT will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but NEWPORT Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: These products are not designed for use in, and should not be used for, patient connected applications. TRADEMARK NOTICE: a , NEWPORT , NEWPORT , newportUS.com, Design” are trademarks of NEWPORT Electronics, Inc. ®

®

®

,

,

,

, and the “Meter Case Bezel

PATENT NOTICE: The “Meter Case Bezel Design” is a trademark of NEWPORT Electronics, Inc., registered in the U.S. This product is covered by one or more of the following patents: U.S. Pat. No. D336,895; 5,274,577/ FRANCE BREVET No. 91 12756/ UK PATENT No. GB2 248 954; GB2 249 837/ SPAIN 2039150; 2048066/ ITALY 1249456; 1250938/ CANADA 2052599; 2052600/ GERMANY DE 4134398 C2. OTHER U.S. AND INTERNATIONAL PATENTS PENDING OR APPLIED FOR. This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.

Page 3

To Order Model ICN77000 SERIES CONTROLLER (Specify Model Number) PROCESS CONTROLLER, DUAL DISPLAY FOR THERMOCOUPLE, RTD, VOLTAGE OR CURRENT INPUTS IN A 1/16 DIN CASE

Model No. Description

Model No.

ICN77

[ ]

Dual displays for simultaneous display of measured value and setpoint. Selectable preset tune, adaptive tune, autotune, PID, PI, PD control modes. The dual control outputs can be configured for a variety of control and alarm applications such as heat, heat/cool, heat/alarm, cool or cool/alarm. The ramp to setpoint feature allows the user to define the rate of rise to setpoint, minimizing thermal shock to the load during start-up. Maximum ramp time 99.59 (HH.MM), Soak: 00.00 to 99.59 (HH.MM),Damping: 1 to 8 in unit steps. Input types J,K,T,E,R,S,B,N,J-DIN°C, RTD 100Ω 0.00385, 100Ω & 1kΩ 0.00392, 0 to 20 mA, 4 to 20 mA, 0 to 100mV, 0 to 1V, 0 to 10Vdc. Alarm 1 output includes SPST relay, 3A @ 120Vac, 3A @ 240Vac. NOTE: The Controller must be ordered completely configured. Options are not field installable. [ ] R3 R5 3 5

CASE TYPE NEMA 1, 1.89 x1.89" (48 x 48mm) bezel and 1.75" ROUND cutout NEMA 1, 2.1 x 2.1" bezel and 1.75” ROUND cutout NEMA 12 bezel for 1/16 DIN panel cutout 45mm x 45mm (1.772 x 1.772") NEMA 4 bezel for 1/16 DIN panel cutout 45mm x 45mm (1.772 x 1.772")

[ ] 2 3 4 5

CONTROL OUTPUT #1 (Direct or Reverse Acting) Solid State Relay SSR : 1A @ 120/240Vac continuous Relay: Form “C” 5A @ 120Vac, 3A @ 240Vac Pulsed 10Vdc @20mA (for use with external SSR) Non-Isolated 1 to 10Vdc or 0-20mA @500Ω max

[ ] 0 2 3 4

CONTROL OUTPUT #2 (Direct or Reverse Acting) Insert “0” if second output is not desired Solid State Relay SSR: 1A @ 120/240Vac continuous Relay: Form “C” 5A @ 120Vac, 3A @ 240Vac Pulsed 10Vdc @20mA (use for external SSR)

* -A2 -C2 -C4 -PV -RSP [ ] *

Description cont.

OPTIONAL OUTPUTS none (no entry required) SPST relay, 3A@ 120Vac, 3A @ 240Vac (Alarm 2) Isolated RS232, 300 to 19.2k baud Isolated RS485, 300 to 19.2k baud Isolated Analog Output Remote Setpoint Selection POWER SUPPLY 90 to 240 Vac/dc, 50 to 400Hz (no entry required)

NEMA 1/UL Type 1: Intended for indoor use, to provide a degree of protection against contact with the enclosed equipment and against limited amount of falling dirt. NEMA 4/UL Type 4: Intended for indoor use, to provide a degree of protection against splashing water, windblown dust and rain, and hose directed water and undamaged by the formulation of ice on the enclosure. Testing-Hosedown: Enclosure is subjected to a stream of water from a hose which has a 1" diameter nozzle and which delivers at least 65 gallons per minute from a distance of 10 to 12 feet for a minimum of 5 minutes. NEMA 12/UL Type 12: Intended for indoor use, to provide a degree of protection against circulating dust, falling dirt, and dripping non-corrosive liquids. Testing-Drip: Enclosure is subjected to a drip pan which produces both splashing and dripping. Testing-Atomized Water: Enclosure is subjected to a spray of atomized water by using a nozzle that produces a 3" round diameter spray, 12" from enclosure. The air pressure is at 30psi. For harsh environments, we recommend installation of the controller for square panel cutouts.

Ordering Examples: 1.) ICN77R322-C2 is a NEMA 1 bezel case with 1.75 inch round hole mounting adaptor, dual SSR control outputs and RS232 communications output. 2.) ICN77330 is a NEMA 12 bezel case with 1/16 DIN mounting and single Relay control output. 3.) ICN77544-A2 is a NEMA 4 bezel case with 1/16 DIN mounting, dual pulse control outputs, and a SPST 3A Alarm relay.

Page 4

NOTES

Page 5

TABLE OF CONTENTS Part 1: Introduction 1.1 1.2

Safety Considerations .........................................................................1 Before You Begin..................................................................................2

Part 2: Setup 2.1 2.2 2.3 2.4

2.5 2.5.1 2.5.2 2.5.3 2.5.4

Mounting the Controller.......................................................................4 Front Panel View ..................................................................................7 Front Panel Annunciators .......................................................................7 Rear Panel View....................................................................................8 Rear Panel Connector Labels ................................................................9 Mechanical Installation ......................................................................10 Dip Switch Configuration ......................................................................10 Dip Switch Settings...............................................................................11 Electrical Installation .........................................................................12 Input Connection Examples .................................................................13 Thermocouple.......................................................................................13 Two/Three/Four Wire RTD ...................................................................14 Process Current ...................................................................................15 Process Voltage ...................................................................................15 i

Page 6

TABLE OF CONTENTS Part 3: Operation: Configuration Mode 3.1

3.2

3.3 ii

Introduction ........................................................................................16 Turning Your Controller on for the First Time .............................................16 Function in Configuration Mode................................................................17 Menu Configuration...........................................................................18 ID Number .............................................................................................19 Set Points ..............................................................................................20 Input Type (Thermocouple) ......................................................................24 Input Type (RTD) ....................................................................................25 Input Type (RTD Value) ...........................................................................26 Input Type (Process) ...............................................................................27 Reading Configuration.............................................................................29 Alarm 1 ..................................................................................................33 Alarm 2 ..................................................................................................36 Loop Break Alarm ...................................................................................38 Output 1 ................................................................................................42 Output 2 ................................................................................................52 Ramp & Soak .........................................................................................58 Available Options...............................................................................60 Analog Output Option..............................................................................61 Communication Option ............................................................................64

Page 7

TABLE OF CONTENTS Configuration Mode Cont. Command Formats ...........................................................................................................72 Reading Scale .............................................................................................................................86 Reading Offset .................................................................................................................87 Remote Setpoint Option ....................................................................................................88

Part 4 Specifcations .........................................................................................91 List of Figures Figure 2.1 a., Mounting the Square Mount Controller .................................................................5 Figure 2.1 b., Mounting the Round Mount Controller ..................................................................6 Figure 2.2, Front Panel Display ...................................................................................................7 Figure 2.3, Typical Rear Connector Label and Possible Labels of Different Models ..................8 Figure 2.4, Dip Switch Location.................................................................................................10 Figure 2.5.1, Power Wiring Hookup...........................................................................................12 Figure 2.5.2, Thermocouple Wiring Hookup..............................................................................13 Figure 2.5.3, Two-wire RTD Hookup, Three-Wire RTD Hookup, Four -Wire RTD Hookup ......14 Figure 2.5.4, Process Current Wiring Hookup...........................................................................15 Figure 2.5.5, Process Voltage Wiring Hookup...........................................................................15 Figure 3.1, Flowchart for ID and Set Point Menus ....................................................................18 Figure 3.2, Flowchart for Input Type..........................................................................................23 Figure 3.3, Flowchart for Reading Configuration.......................................................................28 iii

Page 8

TABLE OF CONTENTS List of Figures Cont. Figure 3.4, Flowchart for Alarm 1 and Alarm 2..........................................................................32 Figure 3.5, Flowchart for Loop Break ........................................................................................37 Figure 3.6, Flowchart for Output 1.............................................................................................41 Figure 3.7, Flowchart for Output 2.............................................................................................51 Figure 3.8, Flowchart for Ramp & Soak ....................................................................................57 Figure 3.9, Flowchart for Analog Output Option ........................................................................61 Figure 3.10, Flowchart for Communication Option....................................................................64 Figure 3.11, Flowchart for Remote Setpoint ..............................................................................88

List of Tables Table 3.1, Communication Commands..................................................................................... 72 Table 3.2, Command Letters and Index .................................................................................. 76 iv

Page 9

part

INTRODUCTION

1

1.1 Safety Considerations This device is marked with the international caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).

• • •

This instrument is a panel mount device protected in accordance with Class I of EN 61010 (115/230 AC power connections). Installation of this instrument should be done by qualified personnel. In order to ensure safe operation, the following instructions should be followed. This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall meet the relevant requirements of IEC 947–1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the main supply cord. Furthermore, to provide protection against excessive energy being drawn from the main supply in case of a fault in the equipment, an overcurrent protection device shall be installed.

• • • •

Do not exceed voltage rating on the label located on the top of the instrument housing. Always disconnect power before changing signal and power connections. Do not use this instrument on a work bench without its case for safety reasons. Do not operate this instrument in flammable or explosive atmospheres. Do not expose this instrument to rain or moisture. Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operating temperature rating. Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.

EMC Considerations • • • •

Whenever EMC is an issue, always use shielded cables. Never run signal and power wires in the same conduit. Use signal wire connections with twisted-pair cables. Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.

Failure to follow all instructions and warnings may result in injury!

1

Page 10

part

1

INTRODUCTION

1.2 Before You Begin Customer Service

If you need assistance, please contact the nearest Customer Service Department, listed in this manual.

Inspecting Your Shipment

Remove the packing slip and verify that you have received everything listed. Inspect the container and equipment for signs of damage as soon as you receive the shipment. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing the contents, save the packing material and carton in the event reshipment is necessary.

Manuals, Software:

The latest Operation and Communication Manual as well as free configuration software are available from the website listed in this manual or on the CD-ROM enclosed with your shipment. For first-time users: Refer to the QuickStart Manual for basic operation and set-up instructions. If you have the Serial Communications Option you can easily configure the controller on your computer or on-line.

2