Page 94

Section 4-1

Setting Up Data Memories When the X-axis Positioning Action Number is 0 m+22 Target speed

Output code m+24 Dwell time m+23

Comple- Direction tion code

Set between 4 and 7 Set to 0 Single, 1 Pause, 2 Continuous, or 3 Bank. Cannot be set to 4 Extended or 5 Extended with positioning. These settings become interpolation data.

When the Y-axis Positioning Action Number is 0

When the Y axis positioning action number is 0, use the same data settings as for the X axis.

m+122 Target speed

Output code m+124

Dwell time m+123

Comple- Direction tion code

Set between 0 and 3, or between 4 and 7 When the X-axis completion code is 2, this setting is ignored.

These settings are ignored.

The target speed set for the X axis becomes the interpolation speed for both the X and Y axes. The velocity component for each axis is illustrated below. Y axis

Interpolation end point

ν

ν : Interpolation speed νx : X-axis speed νy : Y-axis speed

νy θ Origin

νx = ν cos θ νy = ν sin θ

νx X axis

Also refer to the programming examples in Section 9.

87

Page 95

Section 4-1

Setting Up Data Memories Cautions for Using Completion Code 2: Continuous 1. Stepping Motor

Avoid using continuous completion, code 2, with the stepping motor. During interpolation, pulses are output in accordance with the speed changes set for the interpolation and the programmed trajectory. When interpolation is executed continuously, changes in speed for the X and Y axes cause pulses to be output rapidly, and to be stopped suddenly. If the stepping motor does not follow these changes in speed, misadjustment occurs. Consequently, it is prudent to use completion code 2 (Continuous) as little as possible with the stepping motor. Instead, use completion code 1 (Pause).

Interpolation operation Y axis (pulse)

Interpolation speed (PPS)

A

Positioning action #

B a b #2 #2 Continuous Continuous Speed change point A

45° Time point B

0

X axis speed change X-axis speed (PPS) b

1 2a 1 2b

Time

Y axis speed change Y-axis speed (PPS) 1 2a 1 2 b

Time

88

Position

X axis (pulse)

Page 96

Section 4-1

Setting Up Data Memories 2. Programs

During continuous operation, direction cannot be reversed until completion of the positioning action. The following examples illustrate operations that cannot be carried out, because the X axis positioning actions No. 1 and No. 3, and the Y axis positioning actions No. 0 and No. 2, are in the opposite directions. Instead of continuous completion, use completion code 1 (Pause) for positioning action No. 1, or for all the positioning actions.

CW CW Y axis

X axis

Positioning action #0 #1

#2

2: Contin- 2: Con. 2: Con. uous

#3 3: Bank end Time

Origin CCW CW CCW 0

CW X axis

Y axis Time

CCW

89

Page 97

Section 4-1

Setting Up Data Memories 3. Pulse Displacement

Pulse displacement can occur at continuous transition points. C B

νn A’

νc

0-A interpolation speed = A-B interpolation speed =

νc νn

A Pulse displacement

θc 0

The amount depends on the settings of the program, but pulse displacement invariably occurs when continuous completion is used with interpolation. The maximum pulse displacement vector is

Vn , 250 so displacement in the X direction is between 0 and

Vn cos θ , c 250 and displacement in the Y direction is between 0 and

Vn sin θc. 250

Displacement occurs because acceleration/deceleration patterns for interpolation receive priority. During continuous positioning there is no displacement at the final point (C in the diagram above), so positioning can be executed accurately at that point. For accurate positioning at intermediate points, use completion code 1 (Pause).

90

Page 98

Section 4-1

Setting Up Data Memories Speeds

Slight differences exist between speeds set in the DM area and actual speeds. These differences do not affect positioning accuracy. m+82 m+182

15 to 00

Speed #1

0000 to 9999 (BCD)

m+83 m+183

15 to 00

Speed #2

0000 to 9999 (BCD)

m+84 m+184

15 to 00

Speed #3

0000 to 9999 (BCD)

m+85 m+185

15 to 00

Speed #4

0000 to 9999 (BCD)

m+86 m+186

15 to 00

Speed #5

0000 to 9999 (BCD)

m+87 m+187

15 to 00

Speed #6

0000 to 9999 (BCD)

m+88 m+188

15 to 00

Speed #7

0000 to 9999 (BCD)

m+89 m+189

15 to 00

Speed #8

0000 to 9999 (BCD)

m+90 m+190

15 to 00

Speed #9

0000 to 9999 (BCD)

m+91 m+191

15 to 00

Speed #10

0000 to 9999 (BCD)

m+92 m+192

15 to 00

Speed #11

0000 to 9999 (BCD)

m+93 m+193

15 to 00

Speed #12

0000 to 9999 (BCD)

m+94 m+194

15 to 00

Speed #13

0000 to 9999 (BCD)

m+95 m+195

15 to 00

Speed #14

0000 to 9999 (BCD)

m+96 m+196

15 to 00

Speed #15

0000 to 9999 (BCD)

Settings between 92 and 250,000 pps Actual speed (pps) =

6,000,000 INT(6,000,000/set value)

where, INT:

Nearest integer

INT(6,000,000/set value): Divider ratio pps:

pulses per second

Pulse output (actual speed)

6 MHz

Counter LSI Divider

The slight difference occurs because a 6-MHz source clock is divided by the integral divider ratio.

91

Page 99

Section 4-1

Setting Up Data Memories Example Values:

Set Value (pps)

Actual Speed (pps)

250,000

250,000.00

180,000

181818.18

140,000

142,857.14

95,000

95,238.10

3,500

3,500.58

92

92.00

Settings between 1 and 91 pps 23,437.5

Actual speed (pps) =

INT(23,437.5/set value)

Pulse output (actual speed) 23,437.5 Hz Divider

A 23,437.5 Hz source clock is divided by the integral divider ratio. Example Values:

92

Set Value (pps)

Actual Speed (pps)

91

91.20

60

60.10

Page 100

Section 4-1

Setting Up Data Memories Speed Unit Multiplier

Word X-axis m+97

15-12

11-08

Bit

Y-axis m+197

07-04

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

03-01

M+97 0

Function Not used Unit for speed #1 Unit for speed #2 Unit for speed #3 Unit for speed #4 Unit for speed #5 Unit for speed #6 Unit for speed #7 Unit for speed #8 Unit for speed #9 Unit for speed #10 Unit for speed #11 Unit for speed #12 Unit for speed #13 Unit for speed #14 Unit for speed #15

DM word m+3(X)/m+103(Y) bit 04:0 0 x 1 pps

1 x 10 pps

DM word m+3(X)/m+103(Y) bit 04:1 0 x 1 pps

1 x 100 pps

Each bit sets the corresponding speed as follows. Bit 00 is not used. • Bit 00 is not used • Bit 01 is assigned to speed no.1 • Bit 02 is assigned to speed no.2 • Bit 03 is assigned to speed no.3 • Bit 15 is assigned to speed no.15

93

Page 101

Section 4-1

Setting Up Data Memories Acceleration/Deceleration

Acceleration: X: M word m+98 Y: DM word m+198 Deceleration: X: DM word m+99 Y: DM word m+199

15

00 m+98 x103 x102 x101 x100

Acceleration: 2-2000 (BCD)

m+99 x103 x102 x101 x100

Deceleration: 2-2000 (BCD)

Indicates the speed change per millisecond (pps: pulse/second).

Trapezoidal Acceleration/Deceleration

An internal calculation process is used to create a trapezoidal figure from speed, acceleration, and deceleration settings. Speed

Time

When accelerating or decelerating between two speeds, the speed is varied every unit time in a stepwise fashion. To achieve this, acceleration and deceleration tables are created internally when the Unit is first operated or when TRANSFER DATA is used to alter data.

94

Page 102

Unit Table Creation

4-2

Section 4-2

Unit Table Creation The internal processing of the Position Control Unit is as follows during table creation. 1, 2, 3...

1. The speed difference, ∆V, is obtained to express the range of speed settings. ∆V = MAX – MIN where, MAX: Twice the maximum set value (not to exceed 250,000). MIN: Speed indicated by initial speed number. 2. The number of division steps, L, is determined such that the unit time for each step is 4 ms. The maximum number of steps is 250. L = (∆V/R) 4 where, R: Acceleration or deceleration data, whichever greater. ∆V/R: Acceleration (or deceleration) time between MAX and MIN 3. Next, the speed difference (∆υ) for each step is obtained. ∆υ = (∆V/L) 4. The divider ratios for all steps are calculated and set in a table. Target (step) speed

Division ratio

Step 1

Min

2

MIN + ∆υ

3

MIN + 2 x ∆υ

L

MAX

The dividing ratio is an integer value explained on the preceding page.

95

Page 103

Unit Table Creation

Section 4-2 5. Example: Start speed Maximum value of speed data Nos. 1 to 15 Acceleration Deceleration ∆V = 20000 x 2 = 40000 L = (∆V/R) = (40000/100) = 100 4

0 (pps) 20,000 (pps) 100 (pps/1ms) 100 (pps/1ms)

4

∆υ = 40000/100 = 400 υ (Speed) pps

4 ms

40000 39600 39200 38800

400

R = 400= 100 4

20400 20000 19600 19200 1600 1200 800 400 t (Time) 4

96

8

192 200 12 196 204

392 400 ms 388 396