Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of SYSMAC C200H-NC211 Position Control Unit Operation Manual

Manual · Omron

SYSMAC C200H-NC211 Position Control Unit Operation Manual

Manual259 pagesPDF 1.1 MB

Operation manual for the Omron SYSMAC C200H-NC211 two-axis Position Control Unit for stepping motor and servomotor drivers.

Download the PDF1.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

The Omron operation manual for the SYSMAC C200H-NC211 Position Control Unit, a Special I/O Unit that takes positioning commands from outside or from the PC and outputs control pulses to a stepping motor or servomotor driver. It explains the differences from the older C200H-NC112, switch settings, wiring, DM and IR area allocation, the commands, manual operations, the TEACH command, error processing with alarm and error code lists, and 11 programming examples.

Its parts

  1. Introduction
  2. Before Operation
  3. Operation
  4. Commands
  5. IR Area Allocation
  6. Manual Operations
  7. The TEACH Command
  8. Error Processing
  9. Programming Examples

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operation manual for the Omron SYSMAC C200H-NC211 Position Control Unit, a two-axis unit that sends control pulses to stepping motor or servomotor drivers. It explains switch settings, connector wiring, data memory setup, positioning commands, and alarm and error codes, with specifications in an appendix.

Read for this summary: pages 1 to 4, 9 to 14, 17 to 18, 41 to 43, 176 to 178, 185 to 186, 189 to 191, 237 and 244 to 247 of 259.

Device
Position Control Unit (a Special I/O Unit for the C200H PC) that outputs control pulses to a stepping motor or servomotor driver p. 10
Control axes
2 axes per Unit, run together (linear interpolation) or independently p. 10, 244
Positioning data
53 positioning actions per axis p. 11
Position range
–8,388,607 to +8,388,606 pulses p. 244
Speed
1 to 250,000 pps (pulses/second) p. 244
Compensation
Backlash 0 to 9,999 pulses; origin compensation 0 to ±9,999 pulses p. 244
Internal current
500 mA max at 5 VDC, drawn from the Rack p. 244
Size and weight
35 (W) x 130 (H) x 100.5 (D) mm; 500 g max. without connectors p. 244
Inputs
12 to 24 VDC ±10%, 5 mA (at 12 V) to 11 mA (at 24 V); ON 10.2 VDC min., OFF 3.0 VDC max.; 1 ms max. response p. 245
Pulse outputs
NPN open collector, 5 to 24 VDC ±10%, 7 to 30 mA; residual voltage 0.6 V max. p. 245, 246
Origin input
12 to 24 VDC input or a line-driver signal corresponding to Am26LS31, per axis p. 42, 245
Wiring connector
MR-34LF made by Honda Telecommunications Industries, soldered type, included with the unit p. 42
Unit number
0 to 8, set on the MACHINE No. switch; the unit takes two unit numbers p. 17, 18
Alarm and error codes
Alarm codes 1000 to 2352 for faulty setup data; error codes from 5000 when operation cannot proceed p. 189, 190, 191

What this manual walks you through

  • Comparing the unit with the single-axis C200H-NC112 p. 11
  • Setting the unit number and operating mode switches p. 17
  • Reading the front-panel indicators p. 18
  • Wiring limit switches, origin sensors and motor drivers to the I/O connector p. 41, 42, 43
  • Soldering the connector and routing input and output cables p. 43
  • Understanding how alarms and errors arise p. 176, 177
  • Troubleshooting Special I/O Unit errors from the PC and restarting the unit p. 185, 186
  • Looking up alarm codes and error codes p. 189, 190, 191
  • Using the unit in a CS1-series PC p. 237

Good to know

  • The unit occupies the space of two units, so no other unit may use the machine number right after its own. p. 18
  • If only one axis is used, short the CW and CCW limit inputs of the unused axis to 0 V; otherwise the ERROR LED lights. p. 18
  • Use either the origin input or the origin line driver input, not both. p. 42
  • Two-wire sensors must have a leakage current under 1.3 mA. p. 42
  • Turn off power to the PC before operating the setting switches. p. 17

Questions this manual answers

How many axes does the C200H-NC211 control?

Two. It can run both axes together with linear interpolation or control each axis on its own. p. 10

What connector plugs into the C200H-NC211?

An MR-34LF solder-type connector made by Honda Telecommunications Industries, which comes with the unit. p. 42

Why is the ALARM LED flashing on my C200H-NC211?

It flashes when there is a BCD error in the initial data, speed data, or positioning data sent with TRANSFER DATA. p. 18

What does error code 5040 mean?

Present position undefined: START, TEACH, or ORIGIN RETURN cannot run because the present position has not been established. p. 191

How is the C200H-NC211 different from the C200H-NC112?

It adds a second axis with linear interpolation, raises positioning data per axis from 20 to 53, and can transfer speed and position data during positioning. p. 11

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Position Control Unit SYSMAC C200H-NC2111
  2. About this Manual8
  3. SECTION 1 Introduction9
    1. 1-1 Features10
    2. 1-2 Model Differences11
    3. 1-3 System Configuration14
    4. 1-4 Components17
    5. 1-5 Control System Principles19
    6. 1-6 Programming Precautions24
  4. SECTION 2 Before Operation25
    1. 2-1 Operational Flow26
    2. 2-2 Switch Settings28
    3. 2-3 Switch Settings Examples32
    4. 2-4 Wiring41
    5. 2-5 Dimensions56
  5. SECTION 3 Operation57
    1. 3-1 Wiring Data58
    2. 3-2 Data Configuration and Allocation60
    3. 3-3 DM Area Allocation62
  6. SECTION 4 Commands74
    1. 4-1 Setting Up Data Memories75
    2. 4-2 Unit Table Creation102
  7. SECTION 5 IR Area Allocation104
    1. 5-1 IR Area Allocation105
    2. 5-2 IR Area Data Format107
    3. 5-3 IR Area Settings112
    4. 5-4 Execution Examples113
    5. 5-5 ORIGIN SEARCH Completion Examples126
    6. 5-6 Start/Stop129
  8. SECTION 6 Manual Operations132
    1. 6-1 IR Area Settings133
    2. 6-2 HIGH-SPEED JOG134
    3. 6-3 LOW-SPEED JOG135
    4. 6-4 INCH136
    5. 6-5 RESET ORIGIN137
    6. 6-6 External Interrupt Commands138
    7. 6-7 STOP141
    8. 6-8 CHANGE SPEED153
    9. 6-9 CHANGE SPEED COEFFICIENT154
34 more lines, from page 157 on
  1. SECTION 7 The TEACH Command157
    1. 7-1 IR Area Settings159
    2. 7-2 Execution Example161
    3. 7-3 Teaching from the Programming Console162
    4. 7-4 TRANSFER DATA164
    5. 7-5 Present Position Preset171
  2. SECTION 8 Error Processing175
    1. 8-1 Alarms and Errors176
    2. 8-2 Alarm/Error Indicators178
    3. 8-3 RELEASE PROHIBIT179
    4. 8-4 READ ERROR182
    5. 8-5 Troubleshooting from the PC185
    6. 8-6 Detection of Abnormal Pulse Outputs187
    7. 8-7 Alarm Code List189
    8. 8-8 Error Code List191
  3. SECTION 9 Programming Examples194
    1. 9-1 Example 1195
    2. 9-2 Example 2201
    3. 9-3 Example 3204
    4. 9-4 Example 4206
    5. 9-5 Example 5208
    6. 9-6 Example 6213
    7. 9-7 Example 7215
    8. 9-8 Example 8223
    9. 9-9 Example 9224
    10. 9-10 Example 10226
    11. 9-11 Example 11234
  4. Appendices237
    1. Appendix A Application in CS1-series PCs237
    2. Appendix B Specifications244
    3. Appendix C Standard Models247
  5. Glossary248
  6. Index252
  7. Revision History256

From the PDF’s own bookmarks.

The whole text · 32 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Position Control Unit SYSMAC C200H-NC2111-5
  2. Pages 6 to 86-8
  3. SECTION 1 Introduction, pages 9 to 169-16
  4. SECTION 1 Introduction, pages 17 to 2417-24
  5. SECTION 2 Before Operation, pages 25 to 3225-32
  6. SECTION 2 Before Operation, pages 33 to 4033-40
  7. SECTION 2 Before Operation, pages 41 to 4841-48
  8. SECTION 2 Before Operation, pages 49 to 5649-56
  9. SECTION 3 Operation, pages 57 to 6557-65
  10. SECTION 3 Operation, pages 66 to 7366-73
  11. SECTION 4 Commands, pages 74 to 8374-83
  12. SECTION 4 Commands, pages 84 to 9384-93
  13. SECTION 4 Commands, pages 94 to 10394-103
  14. SECTION 5 IR Area Allocation, pages 104 to 113104-113
  15. SECTION 5 IR Area Allocation, pages 114 to 123114-123
  16. SECTION 5 IR Area Allocation, pages 124 to 131124-131
  17. SECTION 6 Manual Operations, pages 132 to 140132-140
  18. SECTION 6 Manual Operations, pages 141 to 149141-149
  19. SECTION 6 Manual Operations, pages 150 to 156150-156
  20. SECTION 7 The TEACH Command, pages 157 to 165157-165
  21. SECTION 7 The TEACH Command, pages 166 to 174166-174
  22. SECTION 8 Error Processing, pages 175 to 184175-184
  23. SECTION 8 Error Processing, pages 185 to 193185-193
  24. SECTION 9 Programming Examples, pages 194 to 202194-202
  25. SECTION 9 Programming Examples, pages 203 to 211203-211
  26. SECTION 9 Programming Examples, pages 212 to 220212-220
  27. SECTION 9 Programming Examples, pages 221 to 229221-229
  28. SECTION 9 Programming Examples, pages 230 to 236230-236
  29. Appendices237-247
  30. Glossary248-251
  31. Index252-255
  32. Revision History256-259

The file

Revision and size

RevisionCat. No. W166-E1-03, revised February 2003
PublisherOMRON
Pages259
PDF1.1 MB
TextText from the PDF itself; pages 74 and 259 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 259

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 259
Page 2
Page 2of 259
Page 3
Page 3of 259