The text of a manual · part 22 of 32
SYSMAC C200H-NC211 Position Control Unit Operation Manual: SECTION 8 Error Processing, pages 175 to 184
Pages 175 to 184 of 259, from SYSMAC C200H-NC211 Position Control Unit Operation Manual
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron C200H-NC211
Page 175
SECTION 8 Error Processing 8-1 8-2 8-3 8-4 8-5 8-6 8-7 8-8
Alarms and Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm/Error Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RELEASE PROHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . READ ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting from the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Detection of Abnormal Pulse Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
170 172 173 176 179 181 183 185
169
Page 176
Section 8-1
Alarms and Errors Section Overview
8-1
This section presents information about Alarms, Errors, and troubleshooting. It explains what to do when errors occur and how to avoid errors before they happen. The end of this section presents a complete list of Alarm Codes and Error Codes.
Alarms and Errors
Alarms
Whenever the Position Control Unit is powered up, or data is transferred into the Unit, checks are performed to ensure that the data is in the proper form and can be used for operation. If an error exists in speed or positioning action data at this time, an alarm code is generated. Errors that result in alarms include BCD errors, out-of-range data, and no-data errors (when required data is set at 0). An alarm will thus be generated, for example, if the required settings are not made in the DM area of the PC. Operation can be continued even after an alarm has been generated, however, as long as the data that generated the alarm is not used.
Errors
If operation is attempted with data for which an alarm has been generated, an error code will be generated and further operation will not be possible. Error codes can also be generated during pulse output, e.g., when an emergency stop results from CW limit input.
170
Page 177
Section 8-1
Alarms and Errors Relationship between Alarms and Errors DM data transfer Power ON
Data check
Alarm generation
200 words corresponding to Unit nos. in DM 1000-1999. For expanded positioning data, 200 words set in DM 0100-0899.
Unit’s system program performs BCD check of data.
The error code corresponding the error data is generated.
START command
Normal data
START execution
Alarm data
The data in use has generated an alarm.
Error generation
Data correction
The data in the corresponding DM area addresses has been corrected.
TRANSFER DATA command
Positioning or speed data changed via TRANSFER.
171
Page 178
Alarm/Error Indicators
8-2
Section 8-2
Alarm/Error Indicators The existence of an alarm or error code is indicated both by the alarm/error LED on the front panel (see figure below) and by the flags (see above) in the IR area of the PC.
Front Panel LED
NC211 RUN CW CCW
X Y ALARM
ALARM indicator flashes when an alarm code has been output and the ERROR indicator lights when an error has occurred.
ERROR
Outputs to the IR Area Twenty words from DM 100-199 allocated for each Unit number. Alarm Flag
X: Bit 03 of word n+10 Y: Bit 03 of word n+15
Error flag
X: Bit 05 of word n+10 Y: Bit 05 of word n+15 05
03
X: (n+10) Y: (n+15)
Alarm flag (1: alarm exists) Error flag (1: error exists)
172
Page 179
RELEASE PROHIBIT
8-3
Section 8-3
RELEASE PROHIBIT When Position Control Unit operation is stopped as a result of input of an emergency stop, CW limit, or CCW limit signal, (i.e., when the N.C. input of any of these turns ON), further pulse output is prohibited. In order to resume pulse output, it is necessary to cancel this prohibition by means of the RELEASE PROHIBIT command bit (bit 04 of word n) and release of the external emergency stop switch.
0V X axis
24 V Power supply CCW limit
CW limit
CCW
CW Positioning axis
Emergency stop
External input pin no.
X axis
CW limit
CCW limit 19 CCW 17
CW Positioning axis
18
20 21
22 34
173
Page 180
RELEASE PROHIBIT
Section 8-3
Execution Examples Example 1: Emergency Stop
The present position is lost during an emergency stop, and positioning cannot be started again directly after RELEASE PROHIBIT. Execute ORIGIN SEARCH before proceeding. Although the following explanation is made with respect to the X axis, the case of the Y axis is essentially the same. The error flag is turned OFF after executing the ORIGIN SEARCH.
Input Emergency stop signal
1 0
START word n, bit 00
1 0 1
RELEASE PROHIBIT word n, bit 04
0
Pulse output Time
1 Emergency stop flag word n+10, bit 04
0 ORIGIN SEARCH (Start) 1
Error flag word n+10, bit 05
0 1
No-origin flag word n+10, bit 11
Turns OFF after ORIGIN SEARCH is completed
0 1
Busy flag word n+10, bit 12
0
6000
Alarm/error code word n+11 ORIGIN SEARCH word n, bit 02
174
1 0
0000
Page 181
RELEASE PROHIBIT
Section 8-3
Example 2: Exceeding CW or CCW Limit
CW limit signal
The emergency stop flag is not affected by exceeding the CW or CCW limit. If a limit is exceeded, pulse output is possible in the opposite direction only. The CW limit is exceeded here, so only CCW output is possible. This example uses JOG to clear the limit flag, but ORIGIN SEARCH may also be used.
1 0 1
START word n, bit 00 RELEASE PROHIBIT word n, bit 04
0 1 0 1
HIGH-SPEED JOG word n, bit 11, 13
0 1
JOG direction word n, bit 12
0
Pulse output
CW Time CCW 1
Error flag word n+10, bit 05
0 1
No-origin flag word n+10, bit 11 Busy flag word n+10, bit 12
0 1 0 1
CW limit flag word n+10, bit 13
Alarm/error code word n+11
0
6100
175
Page 182
READ ERROR
8-4
Section 8-4
READ ERROR The READ ERROR command bit, bit 05 of word n, is set to access error and alarm codes when more than one of these is present (effective on the signal’s rising edge). 05 (n = 100 + 10 x unit number)
n
READ ERROR command bit (READ ERROR begins at the rising edge of this bit.)
The codes are consecutively output to word n+10. Errors and alarms have separate flags, as follows: 05
03 n+10 Alarm flag: Set to 1 when an alarm code has been generated. Error flag: Set to 1 when an error has occurred.
15 n+11 x103
00 x102 x101 x100
Error code (or alarm code)
Word n+11 shows four digits in BCD when displayed on the Programming Console. If there are no errors or alarms, 0000 will be displayed. If there are any errors or alarms, they will be displayed in code. The codes will be displayed in order as READ ERROR is executed. (If there is only one code, however, the display will not change when READ ERROR is executed.) The error or alarm code (word n+11) is updated via I/O refreshing immediately after the READ ERROR command bit is turned ON. The busy flag does not turn ON. READ ERROR can be used within a signal scan.
176
Page 183
READ ERROR
Section 8-4
Execution Example
The following diagram shows an example in which first the alarm code 1501 and then the error code 5000 are displayed.
READ ERROR word n, bit 05
1
Alarm flag word n+10, bit 03
1
Error flag word n+10, bit 05
1
0
0
Display has been changed because another error code has been generated.
Display has been changed because an error code has been read.
1501
5000
1501
First alarm code
Second error code
First alarm code
0 Display will not change because only one alarm code has been generated. Alarm/error code word n+11
Note When either axis is in the middle of data transfer or when the busy flag is turned ON, error codes are not accessed correctly from the data buffer. In such cases, the above example does not apply. Reading from the Programming Console
The following example diagram (for Unit #1) shows how to read an alarm/error code from the Programming Console.
Programming Console Display:
Key sequence:
C111 1501
SHIFT
10005 C111 ^OFF 1501
SHIFT
10005 C111 ^ON 5000
CH
CONT #
PLAY
REC
SET
RESET
B
B
B
1
1
*
A
B
1
1
A
0
MONTR
A
0
F
0
5
MONTR
177
Page 184
READ ERROR Alarm/Error Codes
Section 8-4 X: Word n+11 Y: Word n+16 15
00
X: (n+11) Y: (n+16)
Error code (or alarm code) Generally, a new error (or alarm) outputs a single error code. When the error output bit turns ON, multiple error or alarm codes can be read sequentially.
This word contains only the most recent alarm or error code. Several error codes can be read out in sequence by setting the READ ERROR command bit (X: bit 05 of word n; Y: bit 05 of word n+5). Refer to Section 8-4 READ ERROR.
178