Example 7

Section 9-7

Feeding Pattern

Y axis

10000

No. 1 5000 No. 0 0

10000

20000

X axis

Speed #1, single

X/Y axis 1000 #0, single

(20000, 10000)

(10000, 5000)

Y axis

30000 25000 No. 5 20000 No. 4 15000

No. 3 No. 2

0

30000 40000 50000 60000

X axis

Speed X/Y axis

#3, pause T=0.5 s

#4, pause T=1.0 s

#5, single T=1.0 s

#2, pause (30000, 15000)

216

(40000, 20000)

(50000, 25000)

(60000, 30000)

Page 222

Example 7

Section 9-7

Y axis 30000

21000 20000

No. 11

15000 No. 9 10000

No. 10

No. 8

5000

No. 7 No. 6

0

10000

60000

20000 30000 40000 42000

X axis

Speed X/Y axis #10 continuous #6, continuous

2000

#7 continuous

(10000, 5000)

#8 continuous

(20000, 10000)

#9 continuous

(30000, 15000)

#11, single

(40000, 20000) (42000, 21000)

(60000, 30000)

Y axis 1500 No. 12 –6000 3000 No. 13

X axis

No. 14 –3000

Speed X/Y axis #14 (last action)

#12, pause

T = 0.5 s

(3000, 1500)

(–6000, –3000) (0,0)

#13, pause

217

Page 223

Example 8

9-8

Section 9-8

Example 8

Setting Speed Multiplying the Speed Unit By 10

This example uses Unit no. 0 and the X axis. DM 1003

X X 0 X

Multiplies speed unit by 10

DM 1082

2 0 0 0 x10 Speed No. 1 = 20000 pps

DM 1083

1 0 0 0 x1

DM 1084

1 0 0 0 x10 Speed No. 3 = 10000 pps

DM 1097

0 0 0 A

Speed No. 2 = 1000 pps

Speed unit

1 0 1 0 where, speed No. 1 x 10 speed No. 2 x 1 speed No. 3 x 10

Multiplying the Speed Unit By 100 DM 1003

X X 1 X

Multiplies speed unit by 100

DM 1082

2 0 0 0 x100

Speed No. 1 = 200000 pps

DM 1083

1 0 0 0 x1

Speed No. 2 = 1000 pps

DM 1084

1 0 0 0 x100

Speed No. 3 = 100000 pps

DM 1097

0 0 0 A

1 0 1 0

218

Speed unit where, speed No. 1 x 100 speed No. 2 x 1 speed No. 3 x 100

Page 224

Example 9

9-9

Section 9-9

Example 9

Changing the Target Speed Coefficient Turning ON switches 1 through 3 during operation before a positioning action is started changes the target speed coefficient, and thus the speed of operation. This example use Unit no. 0 and the X axis for the purpose of illustration. CW (pps)

Target speed coefficient 1.5

7500

Target speed coefficient 1.0

5000

Target speed coefficient 0.5

2500 X axis Switch 1 ON

START input

Switch 2 ON

100000

Switch 3 ON

CCW

DM Area Settings ORIGIN Initial RETURN speed speed 1 to F 0 to F DM 1000

1 0 0 0

DM 1001

1 2 1 2

Initial position no. 0 to 52

HIGH- LOW- ORIGIN Origin SPEED SPEED SEARCH prox. JOG JOG speed 1 to F 1 to F

1 to F

1 to F

Positioning action no. 0 Speed Output Dwell Completion code No. time code 1 to F 0 to F 0 to F 0 to 5

DM 1022

1 0 0 0

DM 1023

0 0 0 0

DM 1024

0 1 0 0

DM 1082

5 0 0 0 Speed #1

DM 1083

0 5 0 0 Speed #2

DM 1097

0 0 0 0 Speed units

DM 1098

0 0 0 8 Acceleration

DM 1099

0 0 0 8 Deceleration

Target position

219

Page 225

Example 9

Section 9-9

Program

Start switch DIFU (13) 03000

03000 10000

X axis START command

Switch 1 DIFU (13) 03001

03001 MOV (21) #0005

Target speed coefficient 0.5

102 Switch 2 DIFU (13) 03003 03002 MOV (21) #0010

Target speed coefficient 1.0

102 Switch 3 DIFU (13) 03002

03003 MOV (21) #0015

Target speed coefficient 1.5

102 03001 10107

CHANGE SPEED command

03002

03003 END (01)

Note The START and CHANGE SPEED commands cannot be executed during the same scan.

220

Page 226

Example 10

Section 9-10

9-10 Example 10 Changing Positioning Actions and Using TRANSFER DATA with START DM Area Settings for the X Axis Initial ORIGIN RETURN speed speed 0 to F 1 to F DM 1000

1 0 2 0

DM 1001

1 2 1 2

Initial position no. 0 to 52

HIGH- LOW- ORIGIN Origin SPEED SPEED SEARCH prox. JOG JOG speed 1 to F 1 to F

1 to F

DM 1082

2 0 0 0 Speed #1

DM 1083

0 5 0 0 Speed #2

DM 1084

1 0 0 0 Speed #3

DM 1085

2 5 0 0 Speed #4

DM 1098

0 0 0 6 Acceleration

DM 1099

0 0 0 6 Deceleration

1 to F

DM Area Settings for the Y Axis ORIGIN Initial RETURN speed speed 1 to F 0 to F DM 1100

1 0 2 0

DM 1101

1 2 1 2

Initial position no. 0 to 52

HIGH- LOW- ORIGIN Origin SPEED SPEED SEARCH prox. JOG JOG speed 1 to F 1 to F

1 to F

DM 1182

1 0 0 0 Speed #1

DM 1183

0 5 0 0 Speed #2

DM 1184

1 0 0 0 Speed #3

DM 1198

0 0 0 6 Acceleration

DM 1199

0 0 0 6 Deceleration

1 to F

221

Page 227

Example 10

Section 9-10 Note Although the speeds, acceleration, and deceleration for the Y axis are ignored during interpolation, this data must be input to prevent generation of an alarm.

X Axis Positioning Data DM 0100 Positioning action no. 20

1 0 0 1 0 0 0 0

DM 0112 Positioning action no. 24

6 0 0 1 DM 0103 Positioning action no. 21

1 0 0 1 0 0 0 0

Positioning action no. 22

2 0 0 1 0 0 0 0

DM 0115 Positioning action no. 25

Positioning action no. 23

2 0 0 1 0 0 0 0 7 0 0 0

Positioning action no. 28

3 0 0 1 0 0 0 0

DM 0118 Positioning action no. 26

3 0 0 1 0 0 0 0 6 0 0 1

DM 0127 Positioning action no. 29

1 0 0 3 0 0 0 0 7 0 0 1

6 0 0 0

7 0 0 1 DM 0109

0 0 0 0

DM 0124

6 0 0 1

6 0 0 0 DM 0106

3 0 0 1

4 0 0 1 0 0 0 0 7 0 0 1

DM 0121 Positioning action no. 27

4 0 0 1 0 0 0 0 7 0 0 0

Back Panel Switch Settings ON 1 2 3 4 5 6 7

Expanded DM

8 no. 0-7

9 10

Set to 1 DM 0100-0299

Note Within the C200H DM area (DM 0000-1999), DM 0000 to DM 0999 are read/ write addresses. DM 1000-1999 is read-only memory. The MOV command can rewrite the contents of DM 0000-0999, but not contents of DM 1000-1999.

222

Page 228

Example 10

Section 9-10

Y Axis Positioning Data DM 0200 Positioning action no. 20

1 0 0 1 0 0 0 0

DM 0212 Positioning action no. 24

2 0 0 0 DM 0203 Positioning action no. 21

1 0 0 1 3 0 0 0

Positioning action no. 22

2 0 0 1 0 0 0 0

DM 0215 Positioning action no. 25

Positioning action no. 23

2 0 0 1 3 0 0 0

DM 0218 Positioning action no. 26

3 0 0 1 3 0 0 0

3 0 0 1 0 0 0 0 2 0 0 0

DM 0227 Positioning action no. 29

3 0 0 3 2 0 0 0 3 0 0 1

1 0 0 1 0 0 0 0 2 0 0 0

DM 0221 Positioning action no. 27

2 0 0 0

Operation

Positioning action no. 28

2 0 0 0

2 0 0 0 DM 0209

0 0 0 0

DM 0224

2 0 0 0

2 0 0 0 DM 0206

3 0 0 1

1 0 0 1 3 0 0 0 2 0 0 0

During XY interpolation, the user program changes the X axis data, which is then sent to the NC buffer. After START is executed the data transferred to the buffer is reinitialized. C200H Buffer

RAM

Program changes positioning data. TRANSFER DATA

Buffer Transfer

TRANSFER DATA can be executed whether the data flag is ON or OFF. Buffer transfer can be done only when the busy flag is OFF.

223

Page 229

Example 10

Section 9-10

Program

Start switch DIFU (13) 03000

03000 busy 11012 busy 11512 03002 03002

03002

Positioning completed At-origin 11002 11000

10008

X axis present position reset

10508

Y axis present position reset

At-origin 11502 11012 11512 DIFU (13) 03100

03100 10000

Interpolation START

03200 03100 MOV (21) #6002 DM 0102 MOV (21) #7002 DM 0108 MOV (21) #6002 DM 0114 MOV (21) #7002 DM 0120 MOV (21) #6002 DM 0126 MOV (21) #7002 DM 0129 (continues on next page)

224

Changes the X axis positioning data in the PC