Page 9

SECTION 1 Introduction 1-1 1-2 1-3 1-4 1-5

1-6

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model Differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control System Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5-1 Open-Loop System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5-2 Semiclosed-loop System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 3 6 9 11 13 15 16

1

Page 10

Section 1-1

Features Section Overview

1-1

The C200H-NC211 Position Control Unit is a Special I/O Unit that receives positioning commands, either externally or from a Programmable Controller (PC), and uses that data to output control pulses to a stepping motor driver or a servomotor driver. This section describes the basic features and components of the Position Control Unit, as well as the basic configuration and operating principles of positioning control systems. Be sure to read and study these sections carefully; an understanding of the control system is essential for successful operation.

Features

Applicable Motor Drivers 1, 2, 3...

The pulse train output can be easily connected to either of the following devices: 1. Stepping motor driver 2. Servomotor driver designed for pulse train input

Number of Control Axes and Controlling Capacity

This Unit is distinguished by having two control axes. It is capable of controlling two axes simultaneously (linear interpolation) and controlling each axis independently. It controls speeds and positions through parameters recorded in the DM (Data Memory) Area of the C200H PC.

Compact Size

The Unit is the same size as other Special I/O Units, but its greater capacity makes for increased space efficiency and easier multi-axial control.

Data Transfer

Positioning actions, speeds, and speed changes contained in the DM area or other areas of the PC can be quickly transferred via a TRANSFER DATA command, even during positioning. More flexible control is now possible.

Upward Compatibility

To ensure compatibility with single-axis Position Control units, this Unit has commands and status allocations similar to the C200H-NC112.

2

Page 11

Model Differences

1-2

Section 1-2

Model Differences The C200H-NC211 incorporates the following additional functions and improvements over the C200H-NC112.

Two Control Axes

There are now two control axes, making linear interpolation possible. Of course each axis can also be operated independently.

Increased Positioning Data Capacity

The positioning data capacity of each axis has been increased from 20 to 53. When more than 20 positioning actions are needed, back-panel DIP switch pins No. 7-9 can be set to expand the usable DM area (in 200-word segments from DM 0100 to 0999).

Improved Data Transfer Performance

Speed and position data can be transferred even during positioning.

Improved Speed Change Performance

The speed coefficient can now be used to change speed even during positioning.

Increased Capacity

Two axes provide the word and data memory capacity of two Special I/O Units. The machine number which immediately follows the assigned machine number cannot be set to the other unit. Item

C200H-NC112

C200H-NC211

Available words n to n+9 n to n+19

Data Memory m to m+99 m to m+199

3

Page 12

Model Differences

Section 1-2

Additional DM Area Functions

The origin and origin proximity signal settings are no longer made with the backpanel switch. Instead, they are now set in the following DM words. 15

00 0

0

0

0

0

(X) DM word m+21 (Y) DM word m+121 bit

Designation

0

ORIGIN SEARCH direction

CCW

CW

01

Origin proximity signal presence present absent

02

Origin proximity type

N.O.

N.C.

03

Origin signal type

N.O.

N.C.

04

ORIGIN SEARCH method present absent

N.O: Normally-open contacts N.C: Normally-closed contacts

4

1

00

Page 13

Model Differences

Section 1-2

Additional IR Area Functions Word X-axis n+1

Additional Codes for Target Position Data

Bit

Y-axis n+6

Function

07

CHANGE SPEED COEFFICIENT

15

Transfer buffer

The following code types have been added to distinguish between single-axis target positioning data and interpolation data. x+1 Code

0 x106 x x105 x104 x103 x102 x101 x100

CW Absolute value

1

CCW

2

CW

3

CCW

4

CW

Single-axis end point Incremental value

Absolute value 5

CCW

6

CW

7

CCW

Interpolation end point Incremental value

5

Page 14

System Configuration

1-3

Section 1-3

System Configuration The basic configurations are shown below and on the next page. Unit outputs are connected to a motor driver, for either a stepping motor or servomotor that can receive pulse train inputs. The Unit is controlled by inputs from devices and/ or a control panel. It, in turn, outputs pulse trains and direction signals to control the motor driver. The motor driver controls either a stepping motor or a servomotor, which in turn controls a positioning device (such as a feed screw). Some configurations also require an Input Unit on the C200H PC to control the motor driver.

Stepping Motor Driver Connection

Position Control Unit C200H-NC211

C200H PC Signal line for stepping motor control

Power source

Hand-held Programming Console C200H-PRO27

Control panel Control switch Stepping motor driver Power source

Stepping motor driver

Stepping motor

6

Stepping motor

Page 15

System Configuration

Section 1-3

Servomotor Driver Connection Position Control Unit C200H-NC211

C200H PC Signal line for servomotor driver control

Power source

Hand-held Programming Console C200H-PRO27

Control panel Control switch DC Servomotor Driver R88D-EP06/EP/ 12 or AC Servomotor Driver R88D-SR/RP

Power source

DC Servomotor

DC Servomotor Driver R88D-EP06/EP/12 or AC Servomotor Driver R88D-SR/RP

DC Servomotor

7

Page 16

System Configuration

Section 1-3

Maximum Number of Special I/O Units per PC

The 200H-NC211 Position Control Unit differs from other Special I/O Units in that it occupies twice the usual IR and DM area. Normally, a maximum of 10 Special I/O Units, including Position Control Units, High-Speed Counters, etc., can be mounted to the same PC. The NC211, however, counts as two Units, so a maximum of only five 200H-NC221 Units can be connected per PC. Also be aware that it is possible to connect a combination of Units that require more power than can be provided by the available power supply. For a specific configuration, refer to specifications in the appropriate hardware manuals.

Mounting Location

The Position Control Unit can be mounted to any but the 2 rightmost CPU Rack slots. Mounting the Unit to either of these slots will prevent you from mounting peripheral devices directly to the PC’s CPU. When mounting to an Expansion I/O Rack or Remote Slave I/O rack, however, any slot may be used. In addition to this, for remote I/O devices there are limitations, as described below, due to data transfer capacities.

Number of Special I/O Units Connectable to Remote I/O

Please note the following limitations on the number of Special I/O Units which can be connected to Remote I/O Slave Racks. The numbers given in the following table assume that no other devices are being used, and represent the maximum number of Special I/O Units that can be used on a Remote I/O Slave Rack when the Units are all from group A, B, C or D. A

B

C

D

Number of High-speed Counter, Position Control (NC111/ NC112), ASCII or Analog Input Units.

Number of Multi-point I/O Units.

Number of Temperature Sensor Units.

Number of Position Control Units (NC211).

Total of 4 Units

Total of 8 Units

Total of 6 Units

Total of 2 Units

A combination of Units from different groups must satisfy both of the following equations: 3A + B + 2C + 6D ≤ 12 A+B+C+D≤8

8