SYSMAC C200H-NC211 Position Control Unit Operation Manual: Glossary

Pages 248 to 251 of 259, from SYSMAC C200H-NC211 Position Control Unit Operation Manual

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron C200H-NC211

Page 248

Glossary absolute target position

A target position given in respect to the origin rather than in respect to the present position.

alarm code

A four-digit code which is output to a word in the IR Area to identify the type of alarm which has occurred.

AR area

A PC data area which is used for system flags and status information. Data is retained in this area during a power failure.

backlash compensation

Compensation for the amount of mechanical play, or “looseness,” present in gears. Such play can create positioning inaccuracy when the direction of positioning changes.

bank

A combination of several positioning actions or sequences. A bank begins when START is executed for the initial positioning action and ends when a positioning action with a “bank end” completion code has been executed.

bank end (completion)

A positioning action completion code that designates the positioning action as the final one in a bank.

BCD

An acronym for binary-coded decimal, which refers to decimal numbers encoded in binary notation.

completion code

A parameter for execution of a positioning action that designates what is to happen when that positioning action has been completed. The five possible completion codes are as follows: single, pause, continuous, bank end, extended, and extended with positioning.

continuous (completion)

A positioning action completion code that causes the next positioning action to be executed immediately upon completion of the current one.

CW and CCW

Abbreviations for clockwise (CW) and counterclockwise (CCW). CW and CCW are defined for a motor shaft in reference to a viewer facing the shaft on the end of the motor from which the shaft extends for connection.

CW/CCW limits

Limits on the CW and CCW sides of the origin which can be internally set to restrict Position Control Unit operation.

data area

A memory storage area in the PC. Different types of memory blocks, with differing functions, are stored in the various data areas of the PC. These blocks of memory are built up from single units, or bits, which are grouped into 16-bit words.

DM area

A PC data area in which general operating parameters, speeds, and parameters for positioning actions are stored.

dwell time

A parameter that specifies the period of time during which positioning will stop before execution of the next positioning action following a positioning action with a pause completion code.

error code

A four-digit code which is output to a word in the IR Area to identify the type of error which has occurred.

247

Page 249

Glossary error counter

A device used to ensure positioning accuracy when positioning via pulse trains. The error counter receives the target position as specific number of pulses in a pulse train from the Position Control Unit and outputs analog speed voltages to drive a servomotor accordingly. The specified number of pulses in the error counter is counted down by feedback from an encoder measuring actual motor shaft movement, causing voltage output to stop when the number of pulses equals zero, i.e., when the target position has been reached.

external interrupt

A function whereby positioning may be stopped or speed may be changed during operation in response to an external command.

flag

A bit that is turned ON and OFF automatically by the system to provide information.

host computer

A computer that is used to transfer data to or receive data from a PC in a Host Link System. The host computer is used for data management and overall system control. Host computers are generally small personal or business computers.

IN refresh area

The last five of the ten IR words allocated to each Position Control Unit as refresh areas.

inching

Manual feeding wherein positioning is executed one pulse at a time.

incremental target position

A target position given in respect to the present position, rather than in respect to the origin.

initial position

The present position when START is executed.

IR Area

A PC data area allocated for inputs and outputs. In the C200H, words 100 through 199 of this area are reserved for Special I/0 Units, including the Position Control Unit. The Position Control Unit uses these words for I/0 refresh areas.

N.C. contacts

Normally-closed contacts. A pair of contacts on a relay that open when the relay is energized.

N.O. contacts

Normally-open contacts. A pair of contacts on a relay that close when the relay is energized.

open-loop system

A control system in which a particular operation is carried out according to programmed instructions, but in which feedback is not provided for automatic adjustments.

origin

The point which is designated as 0 at any given time.

origin compensation

A parameter used to correct the origin from the position determined according to the origin input signal.

origin proximity signal

A signal input to indicate when the position is near the origin to enable shifting to a lower speed.

origin proximity

The region near the origin. When positioning enters this region, a proximity switch may output a signal for deceleration.

OUT refresh area

The first five of the ten IR words allocated to each Position Control Unit as refresh areas.

output code

User-defined codes output following completion of a positioning action.

248

Page 250

Glossary parameters

Data which determines limits and other conditions under which an operation will be carried out. The Position Control Unit has both general parameters and parameters specific to individual positioning actions.

pause (completion)

A positioning action completion code that creates a pause after reaching the target position for the positioning action and then automatically begins the next positioning action. The length of the pause is specified by the dwell time.

positioning action

The smallest increment of positioning possible. A positioning action is defined by its completion code, dwell time, output code, speed number, and target position. These actions are generally referred to by number and completion code. For example, “#6, continuous” indicates positioning action #6 with a continuous completion code.

present position

The numeric value in pulses defined as being the ’location’ of the positioning system at any one point in time. The present position is not absolute, but rather can be defined or redefined as required by positioning operations.

proximity speed

A low speed at which positioning is executed near the origin.

pulse rate

The distance moved by an object driven by a motor divided by the number of pulses required for that movement.

pulse train

A series of pulses output together.

pulses

Discrete signals sent at a certain rate. The Position Control Unit outputs pulses, each of which designates a certain amount of movement. Such pulses are converted to an equivalent control voltage in actual positioning.

Remote I/0 Master Unit

The Unit in a Remote I/0 System through which signals are sent to all other Remote I/0 Units. The Remote I/0 Master Unit is mounted either to a CPU Rack or to an Expansion I/0 Rack connected to the CPU Rack.

Remote I/O System

A system in which remote I/0 points are controlled through a Master mounted to a CPU Rack or an Expansion I/0 Rack connected to the CPU Rack.

Remote I/0 Units

Any of the Units in a Remote I/0 System. Remote I/0 Units include Masters, Slaves, Optical I/0 Units, I/0 Link Units, and Remote Terminals.

response time

The time it takes for the PC to output a control signal after it has received an input signal. The response time depends on factors such as the system configuration and when the CPU receives the input signal relative to the start of a scan.

scan time

The total time required for the PC to perform all of the operations involved in executing the program in its memory. The duration of the scan time differs depending on the configuration of the system, the number of I/0 points, the programming instructions used, and so on.

semiclosed-loop system

A control system in which a PC controls an external process without human intervention. This system provides feedback (via a tachogenerator and a rotary encoder) so that actual values (of positions, speeds, and so on) are continuously adjusted to bring them more closely in line with target values.

servolock

An operation whereby a rotary encoder is used to maintain the position of a motor while it is stopped. Whenever the motor axis moves, the rotary encoder sends a feedback pulse to an error counter, causing a rotation voltage to be generated in the reverse direction so that the motor rotates back to its original position.

249

Page 251

Glossary single (completion)

A positioning action completion code that causes positioning to stop after the target position for the positioning action has been reached.

Special I/0 Unit

A dedicated Unit, such as a Position control Unit, High-Speed Counter Unit, or Analog Timer Unit, that is designed for a special purpose.

speed coefficient

An IR Area setting which determines the coefficient with regard to the target speed.

speed number

A number used to designate as a parameter for an operation one of fifteen speeds registered in memory.

speed unit

A bit in the DM Area which can be set to multiply the speed to which it is assigned by a factor of one or ten.

target position

A parameter for a positioning action that designates what position is to be reached at the completion of the action.

teaching

Writing the present position into the DM Area of the PC as the target position for the designated positioning action.

trapezoidal acceleration/deceleration

Accelerating and decelerating in a stepwise pattern such that a trapezoidal figure is formed.

unit numbers

Number assigned to Position Control Units for the purpose of allocating specific I/O words to each unit.

zone

A range of positions which can be defined so that flags are turned ON whenever the present position is within the range. Up to three zones, each with its own flag, can be defined.

250