SYSMAC C200H-NC211 Position Control Unit Operation Manual: SECTION 3 Operation, pages 57 to 65

Pages 57 to 65 of 259, from SYSMAC C200H-NC211 Position Control Unit Operation Manual

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron C200H-NC211

Page 57

SECTION 3 Operation 3-1 3-2 3-3

Wiring Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Configuration and Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DM Area Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50 52 54

49

Page 58

Section 3-1

Wiring Data Section Overview

3-1

This section covers all aspects of Position Control Unit operation other than commands, which are covered in the following section. Included in this section are the basic operating procedure, the type of output pulses possible, the basic data format and configuration, some special features to aid operation, such as flags, zone settings, backlash compensation and internal limits, and the internal data calculation methods used in processing user-input data.

Wiring Data C200H

Programming Console

Data is written, via the Programming Console, or any other programming device into the section of the DM area designated for Special I/O Units. The specific words are DM 1000-1999, with 200 of these words allocated for each unit number assigned to a Position Control Unit. Written data is effective the next time power is turned on or when the system is restarted with the restart bit in the AR area. To write data, use the 3-word change operation of the Programming Console. Programming Console Display

D1824 D1823 D1822 0012 5000 2000 Key Input Sequence B

C

1

DM

EXT

8

C

2

2

MONTR

CHG

The above procedure prepares memory location DM 1824 so that new data can be keyed in. Pressing the CHG key again moves the cursor to DM 1823. After inputting data, press the write key to execute the rewrite. The above example shows X axis positioning action #0 of Unit #8.

50

Page 59

Section 3-1

Wiring Data Special I/O Unit Restart Bits AR Word Bits 100-109

Restart bits can be used to transfer altered DM area data to the Unit without turning power off and on. Modified DM data is sent immediately to the Unit. Refer to the following table for restart bit allocations. The following example of Programming Console operation shows how to access the restart bit for Unit #0. The ladder diagram section after it shows how to achieve the same operation through programming.

Restart Bits

These restart bits are turned ON and back OFF again to restart Special I/O Units. Bit

Unit Number

AR 0100

0

AR 0101

1

AR 0102

2

AR 0103

3

AR 0104

4

AR 0105

5

AR 0106

6

AR 0107

7

AR 0108

8

AR 0109

9 Programming Console Display

A0101 ^OFF Key Input Sequence B

CONT SHIFT

SHIFT

HR

# B

1

MONTR

A

1

0

REC

PLAY

REC

RESET

SET

RESET

Program Example: Unit #1 Restart switch DIFU (13) AR0101

51

Page 60

Data Configuration and Allocation

3-2

Section 3-2

Data Configuration and Allocation IR words 100 through 199 are allocated as Special I/O areas. Each Position Control Unit is allocated twenty consecutive words. The first word for each Unit, designated in this manual as n, can be computed from the unit number as follows: n = 100 + 10 x unit number. IR Example 1 unit #

0

1 unit #

9

Each Unit is also allocated 200 consecutive words as a fixed data area. These words are in the DM area and run from DM 1000 through DM 1999. The first word for each Unit, m, can also also be computed from the unit number: m = 1000 + 100 x unit number (for the X-axis settings). m = 1100 + 100 x unit number (for the Y-axis settings). DM Example 1 unit #

0

0

1 unit #

9

9

These allocations are shown on the following page for all unit numbers. Details of allocations within these words are given under the operations or commands to which they apply. The tables on the following pages give a quick overview of word and bit allocations.

52

Page 61

Data Configuration and Allocation

Section 3-2

C200H PC

Model C200H-NC211

IR Area

I/O Refresh Data Areas

Words 100 to 119 Words 110 to 129

Unit #0 Unit #1

Words 120 to 139

Unit #2

Words 130 to 149

Unit #3

Words 140 to 159

Unit #4

Words 150 to 169

Unit #5

Words 160 to 179

Unit #6

Words 170 to 189

Unit #7

Words 180 to 199

Unit #8

Data is transferred between the PC and each Position Control Unit each time I/O data of the PC is refreshed.

Words 1000 to 1199

Unit #0

Words 1100 to 1299

Unit #1

Words 1200 to 1399

Unit #2

Words 1300 to 1499

Unit #3

Words 1400 to 1599

Unit #4

Words 1500 to 1699

Unit #5

Words 1600 to 1799

Unit #6

Words 1700 to 1899

Unit #7

Words 1800 to 1999

Unit #8

Position Data

OUT refresh n+5 to n+9

(n+10) to (n+14)

IN refresh n+15 to n+19 IN refresh

Fixed Data Areas Data

Words m to m+21

Data is automatically transferred from the PC to each Position Control Unit on power application or when the AR area restart bit is turned ON.

OUT refresh

Twenty words are used (n= 100 + 10 x unit no.)

(X)

DM Area

(Y)

(X)

Words n to (n+4)

Data

(Y)

Parameters

Words m+100 Parameters to m+121

Words m+22 Position to m+81

Words m+122 Position to m+181

Words m+82 Speed to m+97

Words m+182 Speed to m+197

Words m+98 Acceleration

Word m+198

Acceleration

Words m+99 Deceleration

Word m+199

Deceleration

200 words are used (m= 1000 + 100 x unit no.)

Expansion Data Area l to l+99

Position data l+100 to l+199

Position data

200 words are used (L= 100 x unit no.)

Setting#

(Data expansion memory)

Words 0100 to 0299

1

Words 0200 to 0399

2

Words 0300 to 0499

3

100-199 as I/O refresh data area.

Words 0400 to 0599

4

· 200 words for each Unit are allocated in the DM area 1000-1999 as the

Words 0500 to 0699

5 fixed data area.

Words 0600 to 0799

6

Words 0700 to 0899

7

· If need be, back-panel DIP switch pins 7-9 can be set to use 200-word segments in DM 0100-0899 as expanded memory for positioning data.

· For each Special I/O Unit, the C200H-NC211 allocates 20 words in IR area

53

Page 62

DM Area Allocation

3-3

Section 3-3

DM Area Allocation

Data Coding

Although decimal notation is generally used for data in this manual, data is handled in the system as binary-coded decimal (BCD) unless otherwise noted. Note that this data is generally input as decimal, whereas hexadecimal data is input as hexadecimal. The number of digits given for certain data refers to the decimal digits. For example, “7 digits with direction” indicates that the lowest word and rightmost 12 bits of the highest word are allocated to the 7-digit decimal value; the leftmost four bits are allocated to the direction digit.

Coding Sheets

The tables on the following pages can serve as general coding sheets for the DM area, both X and Y axes. Information describing the functions of all of the bits in the DM area is presented beginning on page 57. The numbers shown for the DM words in the following table represent only the final two digits of each word number. In other words, the first two digits (which would be the same for all words) are not shown. The X-axis value of the first two digits can be obtained by computing the first DM word allocated to the Unit. This word, designated m, is equal to 1000 plus 100 times the unit number. Thus, for example, it would be 1000 for Unit no. 0, 1100 for Unit no. 1, and so on. For the Y-axis, the word m is equal to 1000 plus 200 times the unit number. The Y-axis value for Unit no. 1 would be 1200.

54

Page 63

DM Area Allocation

Section 3-3

DM Area Coding Sheet A1 W

15

00

00

Function Initial position nos.; speed nos.

01

03

Origin compensation and direction 0-9999

04

Backlash compensation 0-9999

02

05 06

Axis

W

00

15

DM 1_ 00 to 1 _99

Function

W

Transfer no.

4

5

41

15

71

Positioning action #16

16

Positioning action #17

17

Positioning action #18

18

Positioning action #19

19

73 Positioning action #6

6

42

09

Positioning action #15

72

40

0

68

70 Positioning action #5

39 CCW limit

Function

69

37

0

00

67 Positioning action #4

36

38

15

X axis: Unit no. Y axis: Unit no. +1

Transfer no.

34 35

CW limit

07 08

Unit no.

74 75

Zone 0 CW limit 43

10

44

11 Zone 0 CCW limit 13

47

18 19 Zone 2 CCW limit

20

0

51

84

Speed #3

52

85

Speed #4

86

Speed #5

53

Positioning action #10

10

Speed #6

Positioning action #0

55

88

Speed #7

89

Speed #8

90

Speed #9

91

Speed #10

92

Speed #11

60

93

Speed #12

61

94

Speed #13

95

Speed #14

63

96

Speed #15

64

97

Speed units

98

Acceleration

99

Deceleration

0

56

Positioning action #11

11

57 Positioning action #1

58 1

Positioning action #2

Positioning action #3

59

2 62

31

33

Speed #2

87

30

32

83

9

54

27

29

Speed #1

Positioning action #9

Origin signal type

24

28

82

50 Zone 2 CW limit

26

80 81

49

17

25

8

Zone 1 CCW limit

16

23

79 Positioning action #8

48

15

77 78

46

Zone 1 CW limit

14

22

7

45

12

21 0

76 Positioning action #7

3

65 66

Positioning action #12

Positioning action #13

Positioning action #14

12

13

14

20

21

22

23

24

25

55

Page 64

DM Area Allocation

Section 3-3

DM Area Coding Sheet A2

Unit no.

Axis

W

W

00

15

00

Function

Positioning action #20

20 34 35

Positioning action #21

21 37

07

Positioning action #22

22 40

Positioning action #23

23 43

Positioning action #24

24 46

Positioning action #25

25 49

70

33

73

34

76

35

79

36

22

37

27

55

38

82

28

58

85

88

39

91

59

92

27

60

93

Positioning action #29

29

61

Positioning action #40

40

94

29

62

95

30

63

96

31 32

56

Positioning action #30

30

64 65

47

Positioning action #48

48

Positioning action #49

49

Positioning action #50

50

Positioning action #51

51

Positioning action #52

52

90 Positioning action #39

26

28

Positioning action #47

89

57 Positioning action #28

46

87 Positioning action #38

56

24

Positioning action #46

86

54

23

25

Positioning action #37

53

Positioning action #27

45

81 Positioning action #36

84

21

Positioning action #45

80

51

20

44

78 Positioning action #34

18

52

Positioning action #44

77

83

26

43

75 Positioning action #34

50

Positioning action #26

Positioning action #43

74

17

19

42

72 Positioning action #33

48

15

Positioning action #42

71

47

14

16

32

45

12

Function

69 Positioning action #32

44

11

67 68

42

09

13

31

41

08

10

Positioning action #31

39

06

00

66

38

05

15

X axis: DIP SW setting Y axis: DIP SW setting+1

Transfer no.

36

03 04

W

33

00

02

Function Transfer no.

Transfer no.

01

15

DM 0_ 00 to 0 _98

Positioning action #41

41

97 98

Page 65

DM Area Allocation

Section 3-3

DM Area Allocations Word X axis m

Y axis m + 100 m+1 m + 101 m+2 m+3 m + 102 m + 103 m+4 m + 104 m+5 m + 105

Bit 07 to 00 11 to 08 15 to 12 03 to 00 07 to 04 11 to 08 15 to 12 05 to 00

Function Initial position no., 00 to 52 (BCD): Initial START and START after bank end. Initial speed no., 0 to F (hexadecimal) ORIGIN RETURN speed no., 1 to F (hexadecimal) ORIGIN SEARCH proximity speed no., 1 to F (hexadecimal) ORIGIN SEARCH high speed no., 1 to F (hexadecimal) LOW-SPEED JOG speed no., 1 to F (hexadecimal) HIGH-SPEED JOG speed no., 1 to F (hexadecimal) Origin compensation value, 0000 to 9999 (BCD)

00 Origin compensation direction digit (0: CW; 1: CCW) 03 to 01 Not used 04 Speed unit multiplication 0: multiplies speed unit by 1 (if m+97: 0) or 10 (if m+97: 1) 1: multiplies speed unit by 1 (if m+97: 0) or 100 (if m+97: 1) 07 to 05 Not used 11 to 08 ORIGIN SEARCH dwell time, 0 to F (hexadecimal), in units of 0.1 s 15 to 12 ORIGIN RETURN dwell time 0 to F (hexadecimal), in units of 0.1 s 15 to 00 Backlash compensation value, 0000 to 9999 (BCD) 15 to 00 Internally set value of CW limit **06 0 m+6 m + 106 m+8 m+9 m + 10 m + 107 x105 x106 x105 x103 x104

11 to 00 m + 109

15 to 12 Not used 15 to 00 Zone 0: CW side m+10

15 to 00 x106 direction x106 x105 x105 x104 x102 x101 x100

(7 digits BCD)

x100

(7 digits BCD)

x100

(7 digits BCD)

x100

(7 digits BCD with direction digit)

**05 x103

15 to 12 Not used 15 to 00 Internally set value of CCW limit **08 m + 108 m + 110 x104

11 to 00 Internally set value of CW limit **06 0 m+7 x106

**05 x103 x102 x101

**07 x102 x101 m+9 x104 x103 x102 x101

0 CW 1 CCW

57