For the Omron DRT1-ID16

Page 11

1

Intended Audience

1

Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent).

• Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities.

2

General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for programming and operating OMRON PLC Systems. Be sure to read this manual before attempting to use the software and keep this manual close at hand for reference during operation.

!WARNING It is extremely important that a PLC System and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC System to the abovementioned applications.

3

Safety Precautions !WARNING Never attempt to disassemble any Units while power is being supplied. Doing so may result in serious electrical shock or electrocution.

!WARNING Never touch any of the terminals while power is being supplied. Doing so may result in serious electrical shock or electrocution.

4

Operating Environment Precautions Do not operate the control system in the following places.

• Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to shock or vibration.

xii

Page 12

5

Application Precautions • Locations subject to exposure to water, oil, or chemicals.

• Take appropriate and sufficient countermeasures when installing systems in the following locations. • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. • Locations close to power supplies. !Caution The operating environment of the PLC System can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the PLC System. Be sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the system.

5

Application Precautions Observe the following precautions when using a PLC System.

!WARNING Failure to abide by the following precautions could lead to serious or possibly fatal injury. Always heed these precautions.

• Always ground the system to 100 Ω or less when installing the system to protect against electrical shock. • Always turn OFF the power supply to the PLC System before attempting any of the following. Performing any of the following with the power supply turned on may lead to electrical shock: • Mounting or removing any Units (e.g., Power Supply Units, I/O Units, CPU Unit, etc.) or memory cassettes. • Assembling any devices or racks. • Connecting or disconnecting any cables or wiring. !Caution Failure to abide by the following precautions could lead to faulty operation of the PLC System or could damage the PLC or PLC Units. Always heed these precautions.

• Use the Units only with the power supplies and voltages specified in the operation manuals. Other power supplies and voltages may damage the Units. • Take measures to stabilize the power supply to conform to the rated supply if it is not stable. • Provide circuit breakers and other safety measures to provide protection against shorts in external wiring. • Do not apply voltages exceeding the rated input voltage to Input Units. The Input Units may be destroyed. • Do not apply voltages exceeding the maximum switching capacity to Output Units. The Output Units may be destroyed. • Always disconnect the LG terminal when performing withstand voltage tests.

xiii

Page 13

6

EC Directives

• Install all Units according to instructions in the operation manuals. Improper installation may cause faulty operation. • Provide proper shielding when installing in the following locations: • Locations subject to static electricity or other sources of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radiation. • Locations near to power supply lines.

• Be sure to tighten Backplane screws, terminal screws, and cable connector screws securely. • Do not attempt to take any Units apart, to repair any Units, or to modify any Units in any way. !Caution The following precautions are necessary to ensure the general safety of the system. Always heed these precautions.

• Provide double safety mechanisms to handle incorrect signals that can be generated by broken signal lines or momentary power interruptions. • Provide external interlock circuits, limit circuits, and other safety circuits in addition to any provided within the PLC System to ensure safety. • Always follow electrical specifications for terminal polarity, communications path wiring, power supply wiring, and I/O jumpers. Incorrect wiring can cause failures. • Although the Environment-resistive Slaves have IP66 or IP67 degree of protection, do not use them in applications where the Slave is always submerged in water.

6

EC Directives DeviceNet products conform to EMS and low-voltage level directives as follows: EMC Directives OMRON devices that comply with EC Directives also conform to the related EMC standards, so that they can more easily be built in to other devices or the overall machine. The actual products have been checked for conformity to EMC standards. Whether they conform to the standards in the system used by the customer, however, must be checked by the customer. EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards. Low-voltage Level Directives Always ensure that devices operating at voltages of 50 to 1,000 V AC and 75 to 1,500 V DC meet the necessary safety standard for the PLC (EN61131-2). DeviceNet products that comply with EC Directives must be installed as follows: 1,2,3...

xiv

1. DeviceNet Units are designed for installation inside control panels. All DeviceNet Units must be installed within control panels.

Page 14

7

DeviceNet Manuals

2. Use reinforced insulation or double insulation for the DC power supplies used for the communications power supply, internal circuit power supply, and the I/O power supplies. 3. DeviceNet products that comply with EC Directives also conform to the Common Emission Standard (EN50081-2). Radiated emission characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives. 4. DeviceNet products that comply with EC Directives have configurations with less than 30 m of I/O wiring, and less than 10 m of power supply wiring. The following examples shows how to reduce noise. 1,2,3...

1. Noise from the communications cable can be reduced by installing a ferrite core on the communications cable within 10 cm of the DeviceNet Master Unit. Ferrite Core (Data Line Filter): LF130B (manufactured by Easy Magnet Co.) Impedance specifications 25 MHz: 105 100 MHz: 190

30 mm

13 mm

32 mm

31.5 mm

2. Wire the control panel with as thick and short cables as possible and ground to 100 Ω min. 3. Keep DeviceNet communications cables as short as possible and ground to 100 Ω min.

7

DeviceNet Manuals The following manuals are available for information relating to DeviceNet. Be sure to thoroughly read and understand the applicable manuals before installing or operating DeviceNet devices and make sure that you are using the most recent version of the manual. DeviceNet Operation Manual (W267) Describes the functions and applications of DeviceNet including available Master Units, their specifications, functions, operating procedures, and applications. Always read this manual thoroughly before installing or operating DeviceNet devices. DeviceNet Slaves Operation Manual (W347) Describes available Slave Units, their specifications, functions, operating procedures, and applications. This manual has been separately produced in response to the increase in Slave Unit models since the production of the DeviceNet Operation Manual (W267). Use this manual in conjunction with the DeviceNet Operation Manual (W267).

xv

Page 15

DeviceNet Manuals

7 DeviceNet Configurator Operation Manual (W328) Describes the operating procedures of the DeviceNet Configurator, which is used to freely allocate remote I/O areas, and allows multiple Master Units to be mounted to one PLC or connected to one DeviceNet Network to perform independent remote I/O communications. Refer to this manual when operating a DeviceNet Network with a DeviceNet Configurator. MULTIPLE I/O TERMINAL Operation Manual (W348) Describes available MULTIPLE I/O TERMINALs, their specifications, functions, operating procedures, and applications. This manual has been separately produced in response to the increase in MULTIPLE I/O TERMINAL models since the production of the DeviceNet Operation Manual (W267). Use this manual in conjunction with the DeviceNet Operation Manual (W267).

xvi

Page 16

SECTION 1 Features and System Configuration This section provides an overview of the DeviceNet Network, including features, specifications, and the system configurations. 1-1

Overview of DeviceNet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1-1-1

DeviceNet Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1-1-2

Slaves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

1-1-3

Slave Mounting and Connection Methods . . . . . . . . . . . . . . . . . . . .

11

1

Page 17

Section 1-1

Overview of DeviceNet

1-1

Overview of DeviceNet DeviceNet is a multi-bit, multi-vendor network that combines controls and data on a machine/line-control level and that conforms to the DeviceNet open field network specifications. DeviceNet has the following features.

1-1-1

DeviceNet Features

Multi-vendor Network

The DeviceNet conforms to the DeviceNet open field network specification, which means that devices (Masters and Slaves) produced by other manufacturers can also be connected to the Network. A wide range of field-level applications can thus be supported by combining valve devices, sensors, and other devices. OMRON Master Unit

Master from other company

DeviceNet Network

OMRON Configurator OMRON Slaves

Simultaneous Remote I/O and Message Services

Slave from other company

Remote I/O communications to constantly exchange I/O data between the PLC and Slaves can be executed simultaneously with message communications, to send/receive Master Unit data as required by the application. A DeviceNet Network can thus be installed to flexibly handle applications that require both bit data and message data. Message communications can be achieved either by using OMRON’s FINS commands or by using explicit DeviceNet messages. OMRON Master Unit

OMRON Master Unit

Message communications DeviceNet Network

Slaves Remote I/O communications

2

OMRON Configurator

Page 18

Section 1-1

Overview of DeviceNet Connect Multiple PLCs to the Same Network

A Configurator (sold separately) can be used to enable connection of more than one Master to the Network, allowing message communications between PLCs and between multiple groups of PLCs and Slaves. This allows the DeviceNet Network to be used as a common bus to unify controls while reducing wiring. OMRON Master Unit

OMRON Master Unit

OMRON Master Unit

Message communications

Message communications

DeviceNet Network

OMRON Configurator

Slaves Slaves Remote I/O communications

Multiple Master Units Handle Multi-point Control and Line Expansions

Remote I/O communications

A Configurator (sold separately) can be used to enable mounting more than one Master Unit to a single PLC, allowing control of many more points. This feature can easily handle line expansions and other applications.

OMRON Master Units

Slaves Slaves

Slave

Slave

OMRON Configurator

OMRON Configurator

3

Page 19

Section 1-1

Overview of DeviceNet Free Remote I/O Allocation

A Configurator (sold separately) can be used to enable flexible allocation of I/ O, i.e., in any area and in any order. This allows I/O allocations that suit the application to simplify programming and enable effective usage of PLC memory areas.

OMRON Master Unit Output Area Node 01 Node 03 Node 00

Node 00

Handle Slaves with Different Response Speeds

Node 01

Node 02

Input Area Node 04 Node 02

Node 03

Node 04

OMRON Configurator

A Configurator (sold separately) can be used to set the communications cycle time, enabling usage of Slaves with slow response times. OMRON Master Unit

Set the communications cycle time.

Remote I/O communications at a set interval

OMRON Configurator

Easily Expand or Change Lines with Various Connection Methods

Use a multi-drop trunk line, T-branch multi-drop lines, or daisy-chain drop lines. All three connection methods can be combined to flexibly construct a network that meets the needs of the application.

Multi-drop trunk line

T-branch multi-drop line

Drop line

4

Trunk line

Daisy-chain drop line

Page 20

Section 1-1

Overview of DeviceNet Overall System Configuration

DeviceNet Configurator (computer)

DeviceNet Master Unit CV Series: CVM1-DRM21-V1 CS Series: CS1W-DRM21 C200HX/HG/HE/HS: Photoelectric sensors, C200HW-DRM21-V1 proximity sensors, limit switches, etc.

Photoelectric sensors, proximity sensors, limit switches, etc.

Input Terminal

I/O Link Unit

CQM1

: T-branch Taps or multidrop connections

Input Remote Adapter (used with Input Block)

Sensor Terminal

Output Remote Adapter (used with Output Block)

Output Terminal

Solenoids, valves, etc.

Solenoids, valves, etc.

Photoelectric sensors or proximity sensors with connectors

DeviceNet Master Unit

Environmentresistant Terminal (inputs,outputs, or mixed I/O)

Photoelectric Solenoids, sensors, proximity valves, etc. sensors, limit switches, etc.

C200H I/O Link Unit

Note A DeviceNet Configurator is required if multiple Master Units are to be connected to one network.

Analog Input Terminal

1 to 5 V, 4 to 20 mA, etc.

Analog Output Terminal

Temperature Input Terminal

RS-232C Unit

Inputs Outputs Outputs Inputs Solenoids, valves, etc.

Thermocouple, temperature-resistance thermometer

Bar code reader, etc.

MULTIPLE I/O TERMINALs

Master Features Master Units Support remote I/O communications between OMRON PLCs (CS Series, CV Series or C200HX/HG/HE/HS) and Slaves. Support message communications between OMRON PLCs, or between an OMRON PLC and Slaves and Masters from other companies. VME Master Boards Support remote I/O communications between a VME System and Slaves. Open Network Controllers Support easy connection to an information system via Ethernet.

Configurator Features • Enables free (user-set) allocations to remote I/O. • Enables multiple Master Units on a single PLC. • Enables multiple Master Units in a single network. • The Net-X Server can be used to easily monitor, change, or log I/O data on the DeviceNet.

5