Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of C200HW-DRT21, CQM1-DRT21, DRT1 Series DeviceNet Slaves Operation Manual

Manual · Omron

C200HW-DRT21, CQM1-DRT21, DRT1 Series DeviceNet Slaves Operation Manual

Manual381 pagesPDF 7.8 MB

Operation manual for OMRON DeviceNet slaves: the DRT1 series remote I/O terminals (including the DRT1-ID16), C200HW-DRT21 and CQM1-DRT21.

Download the PDF7.8 MB

Covers · 1 model

The models it covers

Summary

What is in it

OMRON's operation manual for its DeviceNet slave units: the DRT1 series remote I/O terminals, remote adapters, sensor, analog and temperature input terminals, environment-resistive (IP66) and waterproof (IP67) terminals, plus the C200H I/O Link Unit, RS-232C Unit and CQM1 I/O Link Unit. It covers an example system setup, common slave specifications, switch settings, wiring, mounting, communications timing, troubleshooting and maintenance, with appendices on node addresses and using another company's master unit.

Its parts

  1. Precautions
  2. Features and System Configuration
  3. Example System Setup
  4. Common Slave Specifications
  5. General-purpose Slaves
  6. Environment-resistive and Waterproof Slaves
  7. Special I/O Slave Units Specifications
  8. Communications Timing
  9. Troubleshooting and Maintenance

From the manual

Key facts from this manual

Each line names its page in the PDF.

Omron's operation manual (revised September 2003) for the C200HW-DRT21, CQM1-DRT21 and DRT1 Series DeviceNet slaves, a range that includes the DRT1-ID16 remote input terminal. It gives specifications, switch settings, wiring, communications timing and troubleshooting for the whole slave range; this summary draws on the general pages and the DRT1-ID16 section.

Read for this summary: pages 2, 23 to 26, 42 to 44, 48 to 49, 55 to 56, 60 to 64, 76 and 326 to 329 of 381.

What it is
DeviceNet transistor remote input terminal with 16 inputs: DRT1-ID16 is NPN, DRT1-ID16-1 is PNP p. 60
Input voltage levels
ON voltage 15 V DC min., OFF voltage 5 V DC max. p. 60
Input timing, commons
ON and OFF delay time 1.5 ms max.; 16 points with one common p. 60
Power supply
Communications power 11 to 25 V DC from the communications connector; internal and I/O power 20.4 to 26.4 V DC (24 V DC, –15 to +10%) p. 48
Node address
0 to 63 (default 0), set on DIP switch pins 1 to 6 p. 55
Baud rate
125 kbps (default), 250 kbps or 500 kbps on DIP pins 7 and 8; pins 9 and 10 reserved, always OFF p. 55, 61
Dimensions
150 max. x 50 max. x 40 max. mm; two mounting holes, 4.2 dia. or M4, at 140 ± 0.3 and 40 ± 0.3 mm p. 64
Mounting
M4 screw mounting or DIN 35-mm track mounting p. 48
Environment
Ambient temperature 0 to 55°C, humidity 35% to 85%, storage –20 to 65°C, no corrosive gases p. 48
Connections
M3 terminal block, 2 tiers, for I/O and power; normal square DeviceNet communications connector p. 26
Network
DeviceNet remote I/O and explicit messages; up to 63 slaves, 64 nodes including a Configurator p. 43
Cable
Special 5-wire cable (2 signal lines, 2 power lines, 1 shield line); drop lines 6 m max. p. 43
Status indicators
MS (module status) and NS (network status) indicators, green or red, plus an indicator for each input p. 44, 61

What this manual walks you through

  • Choosing a DRT1 Series slave by I/O type and model p. 23, 24, 25, 26
  • Setting the node address and baud rate on the DIP switch p. 55, 56
  • Wiring NPN sensors and switches to the DRT1-ID16 p. 62
  • Wiring the internal power, I/O power and inputs on the terminal block p. 76
  • Preparing and connecting the DeviceNet communications cable p. 49
  • Mounting dimensions of the DRT1-ID16 p. 64
  • Reading the MS and NS indicators p. 44, 327
  • Troubleshooting red indicators and trouble adding a slave to the network p. 328, 329

Good to know

  • Turn off the slave's power, including the communications power, before changing the baud rate. p. 55
  • All nodes need the same baud rate; a node set wrong can disturb communications between the others. p. 55
  • A slave whose node address is already used by the Master or another slave cannot join communications. p. 55
  • The trunk line needs 121-Ω terminating resistors at both ends. p. 329
  • Strip only 30 to 80 mm of cable covering; removing too much can cause short circuits. p. 49

Questions this manual answers

What is the difference between the DRT1-ID16 and the DRT1-ID16-1?

Both are 16-point transistor remote input terminals; the DRT1-ID16 is NPN and the DRT1-ID16-1 is PNP. p. 60

How do I set the node address on an Omron DRT1-ID16?

With pins 1 to 6 of the DIP switch, from 0 to 63; the default is 0. No other node may use the same address. p. 55

What baud rates does the DRT1-ID16 support?

125 kbps (default), 250 kbps or 500 kbps, set with DIP pins 7 and 8. Every node on the network must use the same rate. p. 55

Why is the MS indicator flashing red on a DeviceNet slave?

Check that the baud rate setting is 125, 250 or 500 kbps and restart the unit; if it still flashes red, replace the unit. p. 328

What power supply does the DRT1-ID16 need?

11 to 25 V DC communications power through the communications connector, and 20.4 to 26.4 V DC (24 V DC) internal and I/O power. p. 48

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. W347-E1-06.pdf1
    1. C200HW-DRT21 CQM1-DRT21 DRT1 Series2
    2. DeviceNet Slaves2
    3. About this Manual:8
    4. PRECAUTIONS10
    5. SECTION 1 Features and System Configuration16
    6. SECTION 2 Example System Setup28
    7. SECTION 3 Common Slave Specifications42
    8. SECTION 4 General-purpose Slaves46
    9. SECTION 5 Environment-resistive and Waterproof Slaves190
    10. SECTION 6 Special I/O Slave Units Specifications244
    11. SECTION 7 Communications Timing314
    12. SECTION 8 Troubleshooting and Maintenance326
    13. Appendix A Node Address Settings Table336
    14. Appendix B Using Another Company’s Master Unit338
    15. Appendix C Connectable Devices and Device Current Consumptions358
    16. Appendix D Precautions when Connecting Two-wire DC Sensors368
    17. Glossary370
    18. Index372
    19. Revision History374
  2. Insertion(6182)_add.pdf379

From the PDF’s own bookmarks.

The whole text · 39 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. W347-E1-06.pdf, pages 1 to 101-10
  2. W347-E1-06.pdf, pages 11 to 2011-20
  3. W347-E1-06.pdf, pages 21 to 3021-30
  4. W347-E1-06.pdf, pages 31 to 4031-40
  5. W347-E1-06.pdf, pages 41 to 5041-50
  6. W347-E1-06.pdf, pages 51 to 6051-60
  7. W347-E1-06.pdf, pages 61 to 7061-70
  8. W347-E1-06.pdf, pages 71 to 8071-80
  9. W347-E1-06.pdf, pages 81 to 9081-90
  10. W347-E1-06.pdf, pages 91 to 10091-100
  11. W347-E1-06.pdf, pages 101 to 110101-110
  12. W347-E1-06.pdf, pages 111 to 120111-120
  13. W347-E1-06.pdf, pages 121 to 130121-130
  14. W347-E1-06.pdf, pages 131 to 140131-140
  15. W347-E1-06.pdf, pages 141 to 150141-150
  16. W347-E1-06.pdf, pages 151 to 160151-160
  17. W347-E1-06.pdf, pages 161 to 170161-170
  18. W347-E1-06.pdf, pages 171 to 180171-180
  19. W347-E1-06.pdf, pages 181 to 190181-190
  20. W347-E1-06.pdf, pages 191 to 200191-200
  21. W347-E1-06.pdf, pages 201 to 210201-210
  22. W347-E1-06.pdf, pages 211 to 220211-220
  23. W347-E1-06.pdf, pages 221 to 230221-230
  24. W347-E1-06.pdf, pages 231 to 240231-240
  25. W347-E1-06.pdf, pages 241 to 250241-250
  26. W347-E1-06.pdf, pages 251 to 260251-260
  27. W347-E1-06.pdf, pages 261 to 270261-270
  28. W347-E1-06.pdf, pages 271 to 280271-280
  29. W347-E1-06.pdf, pages 281 to 290281-290
  30. W347-E1-06.pdf, pages 291 to 300291-300
  31. W347-E1-06.pdf, pages 301 to 310301-310
  32. W347-E1-06.pdf, pages 311 to 320311-320
  33. W347-E1-06.pdf, pages 321 to 330321-330
  34. W347-E1-06.pdf, pages 331 to 340331-340
  35. W347-E1-06.pdf, pages 341 to 350341-350
  36. W347-E1-06.pdf, pages 351 to 360351-360
  37. W347-E1-06.pdf, pages 361 to 370361-370
  38. W347-E1-06.pdf, pages 371 to 378371-378
  39. Insertion(6182)_add.pdf379-381

The file

Revision and size

RevisionCat. No. W347-E1-06, Revised September 2003
PublisherOMRON
Pages381
PDF7.8 MB
TextText from the PDF itself.

The first pages · 3 of 381

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 381
Page 2
Page 2of 381
Page 3
Page 3of 381