Manual · Omron
C200HW-DRT21, CQM1-DRT21, DRT1 Series DeviceNet Slaves Operation Manual
Manual381 pagesPDF 7.8 MB
Operation manual for OMRON DeviceNet slaves: the DRT1 series remote I/O terminals (including the DRT1-ID16), C200HW-DRT21 and CQM1-DRT21.
Covers · 1 model
The models it covers
Summary
What is in it
OMRON's operation manual for its DeviceNet slave units: the DRT1 series remote I/O terminals, remote adapters, sensor, analog and temperature input terminals, environment-resistive (IP66) and waterproof (IP67) terminals, plus the C200H I/O Link Unit, RS-232C Unit and CQM1 I/O Link Unit. It covers an example system setup, common slave specifications, switch settings, wiring, mounting, communications timing, troubleshooting and maintenance, with appendices on node addresses and using another company's master unit.
Its parts
- Precautions
- Features and System Configuration
- Example System Setup
- Common Slave Specifications
- General-purpose Slaves
- Environment-resistive and Waterproof Slaves
- Special I/O Slave Units Specifications
- Communications Timing
- Troubleshooting and Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
Omron's operation manual (revised September 2003) for the C200HW-DRT21, CQM1-DRT21 and DRT1 Series DeviceNet slaves, a range that includes the DRT1-ID16 remote input terminal. It gives specifications, switch settings, wiring, communications timing and troubleshooting for the whole slave range; this summary draws on the general pages and the DRT1-ID16 section.
- What it is
- DeviceNet transistor remote input terminal with 16 inputs: DRT1-ID16 is NPN, DRT1-ID16-1 is PNP p. 60
- Input voltage levels
- ON voltage 15 V DC min., OFF voltage 5 V DC max. p. 60
- Input timing, commons
- ON and OFF delay time 1.5 ms max.; 16 points with one common p. 60
- Power supply
- Communications power 11 to 25 V DC from the communications connector; internal and I/O power 20.4 to 26.4 V DC (24 V DC, –15 to +10%) p. 48
- Node address
- 0 to 63 (default 0), set on DIP switch pins 1 to 6 p. 55
- Baud rate
- 125 kbps (default), 250 kbps or 500 kbps on DIP pins 7 and 8; pins 9 and 10 reserved, always OFF p. 55, 61
- Dimensions
- 150 max. x 50 max. x 40 max. mm; two mounting holes, 4.2 dia. or M4, at 140 ± 0.3 and 40 ± 0.3 mm p. 64
- Mounting
- M4 screw mounting or DIN 35-mm track mounting p. 48
- Environment
- Ambient temperature 0 to 55°C, humidity 35% to 85%, storage –20 to 65°C, no corrosive gases p. 48
- Connections
- M3 terminal block, 2 tiers, for I/O and power; normal square DeviceNet communications connector p. 26
- Network
- DeviceNet remote I/O and explicit messages; up to 63 slaves, 64 nodes including a Configurator p. 43
- Cable
- Special 5-wire cable (2 signal lines, 2 power lines, 1 shield line); drop lines 6 m max. p. 43
- Status indicators
- MS (module status) and NS (network status) indicators, green or red, plus an indicator for each input p. 44, 61
What this manual walks you through
- Choosing a DRT1 Series slave by I/O type and model p. 23, 24, 25, 26
- Setting the node address and baud rate on the DIP switch p. 55, 56
- Wiring NPN sensors and switches to the DRT1-ID16 p. 62
- Wiring the internal power, I/O power and inputs on the terminal block p. 76
- Preparing and connecting the DeviceNet communications cable p. 49
- Mounting dimensions of the DRT1-ID16 p. 64
- Reading the MS and NS indicators p. 44, 327
- Troubleshooting red indicators and trouble adding a slave to the network p. 328, 329
Good to know
- Turn off the slave's power, including the communications power, before changing the baud rate. p. 55
- All nodes need the same baud rate; a node set wrong can disturb communications between the others. p. 55
- A slave whose node address is already used by the Master or another slave cannot join communications. p. 55
- The trunk line needs 121-Ω terminating resistors at both ends. p. 329
- Strip only 30 to 80 mm of cable covering; removing too much can cause short circuits. p. 49
Questions this manual answers
What is the difference between the DRT1-ID16 and the DRT1-ID16-1?
Both are 16-point transistor remote input terminals; the DRT1-ID16 is NPN and the DRT1-ID16-1 is PNP. p. 60
How do I set the node address on an Omron DRT1-ID16?
With pins 1 to 6 of the DIP switch, from 0 to 63; the default is 0. No other node may use the same address. p. 55
What baud rates does the DRT1-ID16 support?
125 kbps (default), 250 kbps or 500 kbps, set with DIP pins 7 and 8. Every node on the network must use the same rate. p. 55
Why is the MS indicator flashing red on a DeviceNet slave?
Check that the baud rate setting is 125, 250 or 500 kbps and restart the unit; if it still flashes red, replace the unit. p. 328
What power supply does the DRT1-ID16 need?
11 to 25 V DC communications power through the communications connector, and 20.4 to 26.4 V DC (24 V DC) internal and I/O power. p. 48
Contents
Chapters and sections
Each line opens the PDF at its page.
- W347-E1-06.pdf1
- C200HW-DRT21 CQM1-DRT21 DRT1 Series2
- DeviceNet Slaves2
- About this Manual:8
- PRECAUTIONS10
- SECTION 1 Features and System Configuration16
- SECTION 2 Example System Setup28
- SECTION 3 Common Slave Specifications42
- SECTION 4 General-purpose Slaves46
- SECTION 5 Environment-resistive and Waterproof Slaves190
- SECTION 6 Special I/O Slave Units Specifications244
- SECTION 7 Communications Timing314
- SECTION 8 Troubleshooting and Maintenance326
- Appendix A Node Address Settings Table336
- Appendix B Using Another Company’s Master Unit338
- Appendix C Connectable Devices and Device Current Consumptions358
- Appendix D Precautions when Connecting Two-wire DC Sensors368
- Glossary370
- Index372
- Revision History374
- Insertion(6182)_add.pdf379
The whole text · 39 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- W347-E1-06.pdf, pages 1 to 101-10
- W347-E1-06.pdf, pages 11 to 2011-20
- W347-E1-06.pdf, pages 21 to 3021-30
- W347-E1-06.pdf, pages 31 to 4031-40
- W347-E1-06.pdf, pages 41 to 5041-50
- W347-E1-06.pdf, pages 51 to 6051-60
- W347-E1-06.pdf, pages 61 to 7061-70
- W347-E1-06.pdf, pages 71 to 8071-80
- W347-E1-06.pdf, pages 81 to 9081-90
- W347-E1-06.pdf, pages 91 to 10091-100
- W347-E1-06.pdf, pages 101 to 110101-110
- W347-E1-06.pdf, pages 111 to 120111-120
- W347-E1-06.pdf, pages 121 to 130121-130
- W347-E1-06.pdf, pages 131 to 140131-140
- W347-E1-06.pdf, pages 141 to 150141-150
- W347-E1-06.pdf, pages 151 to 160151-160
- W347-E1-06.pdf, pages 161 to 170161-170
- W347-E1-06.pdf, pages 171 to 180171-180
- W347-E1-06.pdf, pages 181 to 190181-190
- W347-E1-06.pdf, pages 191 to 200191-200
- W347-E1-06.pdf, pages 201 to 210201-210
- W347-E1-06.pdf, pages 211 to 220211-220
- W347-E1-06.pdf, pages 221 to 230221-230
- W347-E1-06.pdf, pages 231 to 240231-240
- W347-E1-06.pdf, pages 241 to 250241-250
- W347-E1-06.pdf, pages 251 to 260251-260
- W347-E1-06.pdf, pages 261 to 270261-270
- W347-E1-06.pdf, pages 271 to 280271-280
- W347-E1-06.pdf, pages 281 to 290281-290
- W347-E1-06.pdf, pages 291 to 300291-300
- W347-E1-06.pdf, pages 301 to 310301-310
- W347-E1-06.pdf, pages 311 to 320311-320
- W347-E1-06.pdf, pages 321 to 330321-330
- W347-E1-06.pdf, pages 331 to 340331-340
- W347-E1-06.pdf, pages 341 to 350341-350
- W347-E1-06.pdf, pages 351 to 360351-360
- W347-E1-06.pdf, pages 361 to 370361-370
- W347-E1-06.pdf, pages 371 to 378371-378
- Insertion(6182)_add.pdf379-381