Page 141

Section 4-7

Sensor Terminals Components DeviceNet Indicators (Refer to page 312.) Power supply terminals

I/O indicators Indicate the status of each contact. (Lit when the input or output is ON.)

Word address Indicates the word which the sensor uses.

I/O connectors Connect the special connectors from the sensors here. (The special connectors are attached to the sensor's cable.) DIN track mounting hooks

Communications connector

DIP switch (Refer to page 40.) Pins 1 to 6: Node address setting Pins 7 and 8: Baud rate setting Pin 9 and 10: Reserved (Always OFF.)

126

Page 142

Section 4-7

Sensor Terminals Internal Circuits

The following diagram shows the internal circuits for the DRT1-HD16S Sensor Terminal. V G

V+ CAN H DRAIN

V–

SOURCE 24 V DC + SOURCE 24 V DC –

Non-isolated power supply

IN-A Internal circuitry

CAN L

IN-B V

Terminals for one sensor

G Isolated power supply

Wiring Terminal Arrangement and Wiring for the Sensor Terminal’s Connector Pin

Function

1

IN-A (inputs)

2 3

IN-B (inputs) VCC (V) (external sensor power supply, +terminal)

4

GND (G) (external sensor power supply, –terminal)

The bit in the DeviceNet I/O area depends on the word address where the sensor is connected, as shown in the following table. Word address 0

0

IN-A bit 8

IN-B bit

1 2

1 2

9 10

3 4

3 4

11 12

5 6

5 6

13 14

7

7

15

127

Page 143

Section 4-7

Sensor Terminals Wiring Example SOURCE 24 V DC +

–

+

–

Sensor Sensor 3-wire sensor 3-wire sensor (with (without self-diagnostic self-diagnostic output function) output function)

Blue (black)

Brown (white)

Blue (black)

Orange (orange)

Brown (red)

Black (white)

Blue (black)

Black (white)

Brown (red)

Internal circuits power supply

Sensor 2-wire sensor (without self-diagnostic output function)

Note In accordance with the changes in the standards for photoelectric sensors and proximity sensors, wire colors have been changed. Colors in parentheses are the old wire colors.

Dimensions The following diagram shows the dimensions for the DRT1-HD16S Input Sensor Terminal. All dimensions are in mm. Approx. 73

12

50 max.

(With connector attached)

150 max.

40 ± 0.3

Mounting holes Two, 4.2 dia. or M4

140± 0.3

128

40 max.

Page 144

Section 4-7

Sensor Terminals

4-7-3

Transistor I/O Sensor Terminals with 8 Inputs and 8 Outputs: DRT1-ND16S

Specifications Input Specifications Item Input points ON voltage

Specification

OFF current

8 NPN points 12 V DC min. (between each input terminal and VCC, the external sensor power supply) 4 V DC max. (between each input terminal and VCC, the external sensor power supply) 1.0 mA max.

Input current ON delay time

10 mA max./point 1.0 ms max.

OFF delay time

1.5 ms max.

OFF voltage

Output Specifications Item

Specification

Output points Rated output current

8 NPN points 20 mA max.

Residual voltage Leakage current

1 V max. 0.1 mA max.

129

Page 145

Section 4-7

Sensor Terminals Components DeviceNet Indicators (Refer to page 312.) Power supply terminals

I/O indicators Indicate the status of each contact. (Lit when the input or output is ON.)

Word address Indicates the word which the sensor uses.

I/O connectors Connect the special connectors from the sensors here. (The special connectors are attached to the sensor's cable.) DIN track mounting hooks

Communications connector

DIP switch (Refer to page 40.) Pins address setting setting Pins 1 to 6: Node address Pins rate setting setting Pins 7 and 8: Baud rate Pin (Always OFF.) OFF.) Pin 9: Reserved (Always Pin tp ts for forcommunications comm nicationserror error Pin 10: Hold/clear outputs

Internal Circuits

The following diagram shows the internal circuits for the DRT1-ND16S Sensor Terminal. V G

V+ CAN H DRAIN

V–

SOURCE 24 V DC + SOURCE 24 V DC –

130

Non-isolated power supply

IN Internal circuitry

CAN L

OUT V G

Isolated power supply

Terminals for one sensor

Page 146

Section 4-7

Sensor Terminals Wiring

Terminal Arrangement and Wiring for the Sensor Terminal’s Connector Pin

Function

1 2

IN (inputs) OUT (outputs)

3

VCC (V) (external sensor power supply, +terminal)

4

GND (G) (external sensor power supply, –terminal)

The bit in the DeviceNet I/O area depends on the word address where the sensor is connected, as shown in the following table. Word address 0

0

IN-A bit 8

IN-B bit

1 2

1 2

9 10

3 4

3 4

11 12

5 6

5 6

13 14

7

7

15

Wiring Example SOURCE 24 V DC +

–

+

–

Sensor

Sensor with teaching function, Sensor with external diagnostic function

Blue

Purple

Black

Brown

Pink (gray)

Blue (black)

Brown (red)

Black (white)

Internal circuits power supply

Sensor

Sensor with bank switching function

Note In accordance with the changes in the standards for photoelectric sensors and proximity sensors, wire colors have been changed. Colors in parentheses are the old wire colors.

131

Page 147

Section 4-7

Sensor Terminals Dimensions

The following diagram shows the dimensions for the DRT1-ND16S Sensor Terminal. All dimensions are in mm. Approx. 73

12

50 max.

(With connector attached)

150 max.

40 max.

40± 0.3

Mounting holes Two, 4.2 dia. or M4

140 ± 0.3

4-7-4

Mounting in Control Panels Either of the following methods can be used to mount an Sensor Terminal in a control panel.

Using Screws

Open mounting holes in the control panel according to the dimensions provided for mounting holes in the dimensions diagrams and then secure the Sensor Terminal with M4 screws. The appropriate tightening torque is 0.6 to 0.98 N⋅m.

Using DIN Track

Mount the back of the Remote Adapter to a 35-mm DIN Track. To mount the Adapter, pull down on the mounting hook on the back of the Terminal with a screwdriver, insert the DIN Track on the back of the Terminal, and then secure the Terminal to the DIN Track. When finished, secure all Slaves on both ends of the DIN Track with End Plates.

132

Page 148

Section 4-7

Sensor Terminals Connecting End Plates

Hook the bottom of the End Plate onto the DIN Track, as shown at (1) in the following diagram, then hook the top of the End Plate as shown at (2). 2

1

End Plate

Note Always attach End Plate to both ends of Slaves connected to DIN Track. Unless specific restrictions are given for the Slave, it can be mounted in any direction. Any of the following directions are okay. 7

7

7

6

6

6

5

5

5

4

4

4

3

3

3

2 1

2 1

0

2 1

0

IN No.

0

7 7 7

IN-B

6 6 6

IN-A

5 5 5

DRT1-HD16S

4 4 4

NS

3 3 3

MS

2 2

7

7

7

6

6

6

5

5

5

4

4

4

3

3

3

2

2

2

1

1

1

0

0

0

IN-B

IN-A

Vertical

No.

SENSOR TERMINAL

2

1 1

IN

1

7

0

7

6

0

7

6

5

0

6

5

4

IN-B

5

4

3

IN-A

4

3

2

DRT1-HD16S

3

2

1

NS

2

1

0

DRT1-HD16S

1

0

NS

0

IN-B

MS

No.

IN-A

NS

MS

MS

SENSOR TERMINAL

DRT1-HD16S SENSOR TERMINAL

SENSOR TERMINAL

No.

IN

Mounting Direction

IN

4-7-5

Wiring Internal Power Supplies, I/O Power Supplies, and I/O Lines

Wiring the I/O Power Supply

The internal circuit power supplies, I/O power supplies, and I/O lines are all wired to M3 screw terminals. Connect M3 crimp terminals and then connect them to the terminal block. Tighten the screws fixing the crimp terminals to a torque of 0.3 to 0.5 N⋅m. 6.0 mm max.

6.0 mm max.

133

Page 149

Section 4-7

Sensor Terminals

Refer to the wiring details for each Slave for information on the terminal arrangement at the terminal block. The following example shows the internal power supply for a DRT1-HD16S Remote I/O Terminal. DRT1-HD16S

No.

SENSOR TERMINAL

IN-A

0

1

2

3

4

5

6

7

IN-B

0

1

2

3

4

5

6

7

DRT1-HD NODE ADDRESS ON

1

2

4

8

16

DR 32

0

1

NC NC

0

1

2

5

4

3

6

7

SOURCE SOURCE 24VDC 24VDC + -

-

+

Wiring the I/O Power Supply and I/O Terminals

The I/O power supply and I/O wiring are connected through the cables of the sensors and other external devices with cable connectors. Assembling Cable Connectors Use the following information to connect the Cable Connectors to the cables on the sensors or other external devices. • Cable Connectors Cover

Plug connector

Confirming the Cable Connector and Cable Core Wire Size There are two models of Cable Connector that vary in the applicable cable core wire size. Model XS8A-0441

XS8-1

Marking

0.3 to 0.5 mm2

Applicable core wire size

XS8A-0442

XS8-2

0.14 to 0.2 mm2

Confirm that the Cable Connector is the correct one for the core wire of the sensor or other external device. Set the same baud rate on all of the nodes The plug connector of the Connector Cable is marked to identify it.

mark XS8-1

Preparing the Sensor or External Device Cable The cable from the sensor or external device (with a connector output transistor) is normally either stripped or semi-stripped. Semi-stripped

134

Stripped

Page 150

Section 4-7

Sensor Terminals

The wires cannot be connected in this condition. Cut the stripped portion of wire off and then remove the sheath as shown in the following illustration. Do not strip the core wires. 20 mm min.

Inserting Core Wires in the Cable Connector When connecting the sensor, align the senor wires by color with the terminal numbers printed on the cover according to the following tables. • DRT1-HD16S Terminal number

3-wire sensor (without selfdiagnosis output)

2-wire sensor (without selfdiagnosis output)

3-wire sensor (without selfdiagnosis output)

1 2

Black (white) ---

Brown (white) ---

Black (white) Orange (orange)

3 4

Brown (red) Blue (black)

--Blue (black)

Brown (red) Blue (black)

• DRT1-ND16S Terminal number 1

Sensor with teaching function Sensor with bank switching or with self-diagnosis output function Black (white) Black

2 3

Pink (gray) Brown (red)

Purple Brown

4

Blue (black)

Blue

Note Wire colors in parentheses are the previous JIS colors for photoelectric and proximity sensors. Insert the core wires completely to the back of the cover holes. Assembling the Cable Connectors 1,2,3...

1. Confirm that the core wires and terminal number are aligned properly using the wire colors. Also be sure that the wires are inserted completely to the back of the cover. (The Cover is transparent so that the wires can be easily seen.) 2. As shown in the following diagram, press the covers with the cable wires inserted into it into the plug connector using your hands to temporarily attach it.

3. As shown in the following diagram, use pliers or a similar tool to press the cover completely into the plug connector. Press on the center of the cover

135